Bradley Terreon Quadra-Fount Washfountain MF2944/TT Installation Instructions Manual

Bradley Multi-Fount™ Series
MF2944/TT
Terreon® Quadra-Fount
®
Washfountain with Touch Time® Control
*Standard Height is ADA Compliant
Installation Instructions
Table of Contents
Pre-Installation Information . . . . . . . . . . . . . . . . . . .2
Washfountain Components List . . . . . . . . . . . . . . . .3
Installation Instructions . . . . . . . . . . . . . . . . . . .4-10
Cleaning and Maintenance . . . . . . . . . . . . . . . .11-12
Solenoid Valve Troubleshooting . . . . . . . . . . .13-14
Thermostatic Mixing Valve Troubleshooting . .15-16
215-1539 Rev. A; EN 03-063 © 2003 Bradley Corporation Page 1 of 16 12-18-2003
P.O. Box 309, Menomonee Falls, WI 53052-0309 TEL. 1-800-BRADLEY FAX 262-251-5817 http://www.bradleycorp.com
IMPORTANT
Read through this installation manual to ensure proper installation.
Make sure that water supply is completely off before installation is begun.
When drilling into tile, masonry, or other hard materials to install wall and floor anchors, be sure to wear safety goggles to prevent eye injuries.
Wall anchors used must have a minimum pull-out rating of 1,000 lbs.
The Quadra-Fount® requires a water flowing pressure of at least 20 psi, but no greater than 80 psi.
File these instructions with the owner or maintenance department.
Terreon® Quadra-Fount® Washfountain with Touch Time® Control MF2944/TT Installation Instructions
Bradley Corporation • 215-1539 Rev. A; EN 03-063
2 12-18-2003
Pre-Installation Information
Terreon®material
The Quadra-Fount® features Terreon®, a durable solid surface material used on the bowl and pedestal. Terreon
®
resists stains, burns and impact, and is repairable with everyday cleaners or fine-
grit abrasives.
Touch Time and solenoid valve
Each Touch Time pushbutton activates a flow of water. Each nozzle is controlled by a separate solenoid valve, allowing each user to activate a flow of tempered water from one spray nozzle with a pushbutton for 15 seconds. Each valve uses less than half the maximum amount of hot water allowed by the ANSI/ASHRAE/IES 90A-1980 Standard.
Solenoid valve: An electronically controlled solenoid valve serves as the metering mechanism. Few moving parts provide reliable metering performance and the solenoid is unaffected by chemicals and minerals often present in municipal water supplies.
Barrier-free and ADA compliant
The Terreon® Quadra-Fount® with Touch Time is designed to comply with all ADA guidelines on reaches, clearances and operation when mounted at standard height dimensions by the installer (see page 4 of this instruction manual for rough-in and mounting dimensions).
Terreon® Quadra-Fount® Washfountain Warranty Information
Bradley Corporation warrants to commercial and institutional purchasers only each unit free from defects in material and workmanship under normal use and service upon the following terms and conditions.
1. This warranty is limited to replacing or repairing, at our option, transportation charges prepaid by the purchaser, any Bradley unit or part thereof which our inspection shall show to have been defective within the limitations of this warranty.
2. The period during which Terreon
®
Quadra-Fount® components are warranted is as follows:
• Terreon
®
side panels, bowl, and top cover warranted for 5 years.
• All other Quadra-Fount® components warranted for 1 year.
3. This warranty does not cover installation or any other labor charges and does not apply to any units which have been damaged by accident, abuse, improper installation or improper maintenance.
4. The replacement or repair of defective units as stated in this warranty shall constitute the sole remedy of the purchaser and the sole liability of Bradley Corporation under this warranty. Bradley Corporation shall not otherwise be liable under any indirect damages caused by defects in the repair or replacement thereof.
5. This warranty extends only to commercial and institutional purchaser and does not extend to any others, including consumer customers of commercial institutional purchasers.
6. This warranty is in lieu of all other warranties, expressed or implied, including any implied warranty of merchants ability or fitness for a particular purpose or otherwise.
Terreon® Quadra-Fount® Washfountain with Touch Time® Control
Installation Instructions MF2944/TT
3
Bradley Corporation • 215-1539 Rev. A; EN 03-063
12-18-2003
Parts Included with the Quadra-Fount®
Separate all parts from packaging materials and ensure you have all the parts required for assembly. If any parts are missing, do not attempt to assemble the Quadra-Fount® until you obtain all parts.
Supplies required:
• (6) 3/8" diameter bolts with washers and (6) wall anchors appropriate for your installation
• (2) 3/8" diameter bolts with washers and (2) floor anchors appropriate for your installation
• 1/2" NPT Hot and cold water supply lines
• Drain trap and waste connection
• Pipe sealant and plumber’s putty
• 110 VAC power source for 110/24 VAC plug-in transformer supplied
• OPTIONAL: Bradley recommends installing an electrical cut-off switch to the unit. This feature prevents accidental water delivery during regular maintenance and service.
TEMPERED LINE
S45-2081 (OPTIONAL)
Stop/Check
Solenoid Assembly with
Two Mounting Screws
Hose
VALVE PREPACK S45-2082
Stop/Check
Hose
Terreon® Quadra-Fount® Washfountain with Touch Time® Control MF2944/TT Installation Instructions
Bradley Corporation • 215-1539 Rev. A; EN 03-063
4 12-18-2003
Installation Instructions
Step 1: Install the 24 VAC transformer
CAUTION: The Quadra-Fount® must be connected with a 24 VAC Class II plug-in
transformer. Connection with 110 VAC will result in damage to the electronics and could result in personal injury.
IMPORTANT: Consult local electrical codes for the mounting location of the 110/24
VAC Class II plug-in transformer.
IMPORTANT: Compliance and conformity to local codes and ordinances is the
responsibility of the installer.
Step 2: Rough-in piping and install wall anchors
NOTE: See Figure 1 for piping rough-in dimensions and wall anchor locations.
IMPORTANT: Make sure that the water is completely shut off before beginning
installation.
1. Rough-in hot and cold supply lines through the wall or floor.
2. Rough-in a drain waste connection through the wall or floor.
IMPORTANT: Wall anchors need to withstand 1000 lb. pull force.
P
Figure 1
* Subtract 4" from this dimension for juvenile height model.
11"
7"
(178)
7-1/2"
(191)
(279)
7"
(178)
21-3/4"
(552)
(2) APPROPRIATE ANCHORS AND 3/8" BOLTS (SUPPLIED BY INSTALLER TO MOUNT BOWL TO WALL
1-1/2 NPT WASTE CONNECTION FOR USE WITH 1-1/2" TUBULAR P-TRA STUB OUT MIN. 1-1/2"
8"
(203)
5-1/8" *
(130)
1/2 NPT SUPPLIES - 5" FROM WALL STUB OUT MIN. 1-1/2" FROM FLOOR
1-1/2" NPT WASTE CONNECTION THROUGH FLOOR - 3" FROM WALL
110V GFI ELECTRICAL
OUTLET RECOMMENDED
LOCATION (REFER TO LOCAL
CODES BEFORE ROUGH-IN)
FINISHED FLOOR
28" *
(711)
24" *
(610)
17-1/2" *
(445)
11"
(279)
(51)
2"
1/2 NPT SUPPLIES STUB OUT MIN. 1-1/2" FROM WALL
Terreon® Quadra-Fount® Washfountain with Touch Time® Control
Installation Instructions MF2944/TT
5
Bradley Corporation • 215-1539 Rev. A; EN 03-063
12-18-2003
Installation Instructions continued . . .
Step 3: Assemble pedestal
NOTE: Washers are not utilized on back of mounting panel. Refer to Figure 2 when assembling pedestal.
1. Fasten the mounting panel to the pedestal with four pan head 1/4"- 20 x 1/2" screws supplied.
2. Install the upper bracket to the pedestal panels with two pan head 1/4"- 20 x 1/2" screws and 5/16" I.D washers supplied.
3. Install the lower bracket to the pedestal panels with two pan head 1/4"- 20 x 1/2" screws and 5/16" I.D. washers supplied.
Figure 2