Bradley SS-3/AZ/WH97TAS Installation Instructions Manual

IMPORTANT
Read this entire installation manual to ensure proper installation, then file the manual with the owner or maintenance department.
Flush all the water supply lines before making connections.
Wall anchors used must have a minimum pull-out rating of 1,000 lbs.
Product warranties may be found under "Product Information" on our web site at www.bradleycorp.com.
P.O. Box 309, Menomonee Falls, WI 53052-0309 TEL. 1-800-BRADLEY FAX 262-251-5817 http://www.bradleycorp.com
Table of Contents
Pre-Installation Information . . . . . . . . . . . . . . . .2
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Installation Instructions . . . . . . . . . . . . . . . . 5-10
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . .10
Cleaning and Maintenance . . . . . . . . . . . . . . . .11
Soap Dispenser Maintenance . . . . . . . . . . . .2-13
Assembly of Components . . . . . . . . . . . . . . .3-14
Check Valve Troublshooting . . . . . . . . . . . . . .15
Solenoid Valve Troubleshooting . . . . . . . . . .5-16
Vernatherm™ Mixing Valve . . . . . . . . . . . . . . .17
SS-3/AZ/WH97TAS Express® Lavatory
System SS-Series
Complies with Texas Accessibility Standards (TAS) for Juvenile Height applications.
215-1175 Rev. H; EN 08-805 © 2008 Bradley Corporation Page 1 of 17 4/24/08
Installation Instructions
OBSOLETE
Express® Lavatory System SS-Series SS-3/AZ/WH97TAS Installation - Obsolete
2 4/24/08 Bradley Corporation • 215-1175 Rev. H; EN 08-805
Pre-Installation Information
Texas Accessibility Standards compliant:
The SS-3/AZ/WH97TAS Express® Lavatory System meets Texas Accessibility (TAS) requirements for barrier-free clearances, reaches and controls. Always check local codes and ordinances for compliance.
Infrared sensor and solenoid
Each sprayhead is controlled by a separate sensor and solenoid valve, enabling each user to activate a single flow of water. Each valve uses less than half the maximum of hot water allowed by the ANSI/ASHRAE/IES 90A-1980 Standard.
Supplies required for installation:
• (10) 3/8" wall anchors, bolts and washers to mount frame and bowl to wall (minimum pull-out rating of 1,000 lbs.)
• 1/2" NPT tempered supply piping
• 1-1/2" NPT drain piping
• 110 volt electrical outlet for 110/24 VAC plug-in transformer (supplied)
Express® Lavatory System SS-Series
Installation - Obsolete SS-3/AZ/WH97TAS
3Bradley Corporation • 215-1175 Rev. H; EN 08-805 4/24/08
SS-3/AZ/WH97TAS Express® Lavatory System Dimensions
Express® Lavatory System SS-Series SS-3/AZ/WH97TAS Installation - Obsolete
4 4/24/08 Bradley Corporation • 215-1175 Rev. H; EN 08-805
Dimensions continued . . .
Juvenile Height
SS-3/AZ/WH97TAS
Grades 6 thru 8 or 9
Juvenile Height
SS-3/AZ/WH97TAS
Grades Pre-K thru 5 or 6
Express® Lavatory System SS-Series
Installation - Obsolete SS-3/AZ/WH97TAS
5Bradley Corporation • 215-1175 Rev. H; EN 08-805 4/24/08
Installation Instructions
Step 1: Rough in
Note: See Figure 1 (below), and Figures 1A and 2 (on page 6) when roughing in the Express®.
IMPORTANT: Flush the supply lines before making connections. Debris in suppl y
lines will cause the valves to malfunction.
IMPORTANT: Dimensions shown in Figure 1 are for Juvenile Height (grades Pre-K
thru 5 or 6) and in Figure 1A for Juvenile Height (grades 6 thru 8 or 9)
IMPORTANT: Turn OFF electrical power to the outlet when installing the Express®.
1. Rough in 1/2" NPT hot and cold supply lines through wall at dimensions shown below.
2. Rough in 1-1/2" NPT drain waste connection through wall at dimensions shown below.
3. Install the 110 volt GFCI electrical outlet per local code at the location shown in Figure 2 on page 6.
4. Install (10) 3/8" wall anchors with a minimum pull-out rating of 1,000 lbs. (supplied by installer) at the locations shown in Figure 1 and 1a on pages 5- 6.
NOTE: The anchors will be used to mount the Express® bowl and frame to the wall.
Step 1: Rough-in continues...
Figure 1
Juvenile Height SS-3/AZ/WH97TAS Express® Lavatory System
(grades Pre-K thru 5 or 6)
Express® Lavatory System SS-Series SS-3/AZ/WH97TAS Installation - Obsolete
6 4/24/08 Bradley Corporation • 215-1175 Rev. H; EN 08-805
Figure 2
Figure 1a
Juvenile Height SS-3/AZ/WH97TAS Express® Lavatory System
(grades 6 thru 8 or 9)
Loading...