Bradley S19-220 Installation Manual

Installation
S19-220
en pared
Table of Contents
Pre-Installation Information . . . . . . . . . . . . . . 2
Installation Instructions. . . . . . . . . . . . . . . . . . 3
Assembly of Components . . . . . . . . . . . . . . . 4
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Table des matières
Avant l’installation. . . . . . . . . . . . . . . . . . . . . . 5
Instructions d’installation . . . . . . . . . . . . . . . . 6
Assemblage des composantes . . . . . . . . . . . 7
Liste des pièces . . . . . . . . . . . . . . . . . . . . . . . 7
Contenido
Información previa a la instalación. . . . . . . . . 8
Instrucciones de instalación. . . . . . . . . . . . . . 9
Armado de los componentes . . . . . . . . . . . . 10
Lista de piezas . . . . . . . . . . . . . . . . . . . . . . . 10
215-158 Rev. W; ECN 08-503 © 2008 Bradley Corporation Page 1 of 10 2/4/08
P.O. Box 309, Menomonee Falls, WI USA 53052-0309 PHONE 1-800-BRADLEY FAX (262) 251-5817 bradleycorp.com
S19-220 Installation
IMPORTANT
Installation
R
1
5 0 3 I 5
W ,
s ll a F
e e n o
R P
m o
U
n
Z
e
H
M ,
IC
9
L
0
K
T
3
E
N E
x
E
eek an
o
H
W
C
B
H
.
Ö
h w
C
O
c
E
.
W
A
P
R I
T
E
s immed
S
A T I
D 1
Testbe
N
A
T
e(s) ea
U
Ä M R
S
O
I
alv
h im
E D
H
eglic
T
B
G
alfunction
tlic
E
S
T
E
S
H I
S
E
y m
hen
T
A
E
hrift. J
I
perate v
S
D
öc
S E
nnem
'il y
ntersc
Test-o
eport an
m
R
as. S
fonctio
Ventil(e) w
t im
durch U
e en b
Test le
rappor sign un
Date
Datum
Date
114-051
. N E F Ü
belo
d sign
. y
el
prüfen,
iat
b
g s trie törun
es he S
alv
e c es v ent d
ent. à quelqu édiatem
Signed Unterschrift
Signe
. w
ätigt est elden.
b
aine et
t m
as fait
or
a p
of
e v chaque sem se qui n ho
Date
Date
Date
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA
TEL: 1-800-BRADLEY FAX: (262-251-5817)
Read this installation manual completely to ensure proper installation, then file it with the owner or maintenance department. Compliance and conformity to drain requirements and other local codes and ordinances is the responsibility of the installer.
Separate parts from packaging and make sure all parts are accounted for before
Packing List
THIS SIDE UP
discarding any packaging material. If any parts are missing, do not begin installation
until you obtain the missing parts.
Flush the water supply lines before beginning installation and after installation is complete. Test the unit for leaks and adequate water flow. Main water supply to the eyewash should be “ON” at all times. Provisions shall be made to prevent unauthorized shutoff.
The ANSI Z358.1 standard requires an uninterruptible supply of flushing fluid at a minimum 30 PSI (0.21 MPa) flowing pressure. Flushing fluid should be tepid per ANSI Z358.1.
Signed Signed Signed
The inspection and testing results of this equipment should be recorded weekly to verify proper operation. This equipment should be inspected annually to ensure compliance with ANSI Z358.1.
Workers who may come in contact with potentially hazardous materials should be trained regarding the placement and proper operation of emergency equipment per ANSI
http://www.bradleycorp.com
Z358.1.
For questions regarding the operation or installation of this product, visit www. bradleycorp.com or call 1-800-BRADLEY.
Product warranties may also be found under ”Product Information” on our web site at www.bradleycorp.com.
2
2/4/08 Bradley Corporation • 215-158 Rev. W; ECN 08-503
Installation S19-220
Installation
Supplies Required:
• (3) 3/8” wall fasteners and bolts
• Pipe sealant
• Piping to 1/2” NPT water supply inlet on unit
• Piping to 1-1/4” NPT drain outlet for eyewash
• Sign-mounting hardware
NOTE: Local codes may require the installation of a backfl ow prevention valve to complete proper installation. Compliance with local codes is the responsibility of the installer. Valve must be tested annually to verify that it is functioning properly. Backfl ow prevention valves are not included with the fi xture and may be supplied by the contractor or purchased from Bradley Corporation.
Step 1: Install inlet drain fitting
NOTE: The top of the eyewash heads should be 33”–45” (838mm–1143mm) from the floor.
1. Position the inlet drain fitting over the 1-1/4” drain outlet pipe from wall.
2. Using the inlet drain fitting as a template, mark the bolt hole locations on wall OR install three suitable fasteners (supplied by installer) for 3/8” bolts in the wall at the marked hole locations.
3. Bolt the inlet drain fitting to the wall or wall fasteners using 3/8” bolts (supplied by
installer).
13-1/4"
(337mm)
7-3/8"
(187mm)
7-1/4"
(184mm)
2-1/4"
(57mm)
Ø 5/16"
(8mm)
Ø 10" (254mm)
15-1/2" (394mm)
4"
(102mm)
5-1/4"
(133mm)
Step 2: Assemble components
1. Assemble the remaining eyewash components as shown on page 4.
• Apply pipe sealant (supplied by installer) to
all male-threaded pipe joints.
• Use a strap wrench around pipes when
tightening to prevent pipe marring.
Step 3: Connect water supply
1. Connect the water supply piping to the 1/2” NPT inlet on the eyewash (piping supplied by installer).
2. Connect the tailpiece to the 1-1/4” NPT drain outlet on the eyewash.
3. Mount the safety sign to the wall using sign­mounting hardware (supplied by installer).
4. Open the water supply lines. Test for leaks and adequate water flow.
36" (914mm)
Suggested
Height
To Floor
30-1/2"
(775mm)
Suggested
Height
To Floor
NOTE: All dimensions assume standard thread engagement. Variations in manufacturing allow for +/- 1/8 (3mm) per threaded joint. To fi nd the tolerance of a dimension, add the number of thread joints in between a dimension and multiply it by 1/8 (3mm).
4-1/2"
(114mm)
8-1/4"
(210mm)
Wall
Bradley Corporation • 215-158 Rev. W; ECN 08-503 2/4/08