Bradley LavCare LC500 L/F, LavCare LC500 L/W Installation And Maintenance Instructions Manual

Bradleys LavCare 500 Series Patient Care Module
Models LC500 L/F and L/W)
Installation and Maintenance Instructions
215-857 Rev. B; EN 97-1016 Page 1 of 11
Table of Contents
Pre-Installation Information . . . . . . . . . . . . . . .2
LC500 Components and Dimensions . . . . . . . .3
LC500 L/F Rough-Ins . . . . . . . . . . . . . . . . . . .4
LC500 L/W Rough-Ins . . . . . . . . . . . . . . . . . . .5
Installation Instructions . . . . . . . . . . . . . . . .6-10
Cleaning and Maintenance . . . . . . . . . . . . . . .11
P.O. Box 309, Menomonee Falls, WI 53052-0309 Phone (262) 251-6000 Fax (262) 251-5817 http://www.bradleycorp.com
Pre-Installation Information
Overview
The Bradley LavCare module is a patient water closet and lavatory station in one unit. The unit has three access panels for ease of installation and maintenance. The LC500 countertop is made from cultured marble and the water closet is stainless steel.
Supplies required for installation:
 (6) wall anchors and bolts to secure cabinet to wall at 3/4 mounting holes  Steel angles and hardware for anchoring the water closet (if concrete is lightweight or
less than 4 thick)  4 floor/wall closet waste connection fittings  Shims (for water closet or cabinet installation, if necessary)  Supply piping to water closet and faucet or foot valve  Waste outlet piping to water closet  P-trap and drain piping  Silicone caulk
Bradley LavCare 500 Series Patient Care Module Model LC500 L/F and L/W Installation Instructions
2 Bradley Corporation  215-857 Rev. B; EN 97-1016
Bradley LavCare 500 Module Warranty Information
Bradley Corporation warrants to commercial and institutional purchasers only each unit free from defects in material and workman­ship under normal use and service upon the following terms and conditions:
1. This warranty is limited to replacing or repairing, at our option, transportation charges prepaid by the purchaser, any Bradley unit or part thereof which our inspection shall show to have been defective within the limitations of this warranty.
2. The period during which LC500 components are warranted is one (1) year, measured from the date of our invoice.
3. This warranty does not cover installation or any other labor charges and does not apply to any units which have been damaged by accident, abuse, improper installation or improper maintenance.
4. The replacement or repair of defective units as stated in this warranty shall constitute the sole remedy of the purchaser and the sole liability of Bradley Corporation under this warranty. Bradley Corporation shall not otherwise be liable under any indirect damages caused by defects in the repair or replacement thereof.
5. This warranty extends only to commercial and institutional purchaser and does not extend to any others, including consumer customers of commercial institutional purchasers.
6. This warranty is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability or fitness for a particular purpose or otherwise.
IMPORTANT
 Read this entire instruction sheet to ensure proper installation.  Flush all the water supply lines before making connections.  File these instructions with the owner or maintenance department.
Bradley LavCare 500 Series Patient Care Module
Installation Instructions Model LC500 L/F and L/W
3Bradley Corporation  215-857 Rev. B; EN 97-1016
LC500 Components and Module Dimensions
4 WRISTBLADE CENTERSET FAUCET
FLUSH ACTUATOR
RECESSED TOILET TISSUE HOLDER
15 (381) X 15 (381)
ACCESS PANEL
2
(51)
(MM)
36-1/8
(918)
29 (737)
32-7/8
(835)
CULTURED MARBLE COUNTERTOP
WATER CLOSET WITH HINGED SEAT
GRAB BAR
10 (254) X 24 (610)
ACCESS PANEL
17
(432)
13-7/8
(352)
33-1/4 (845)
Bradley LavCare 500 Series Patient Care Module Model LC500 L/F and L/W Installation Instructions
4 Bradley Corporation  215-857 Rev. B; EN 97-1016
Installation Instructions
Step 1: Rough-in supply, drain and waste piping
NOTE: Use the submittal drawing when roughing in the LC500.
IMPORTANT: Flush the supply lines before making connections. Debris in supply
lines can cause the valves to malfunction.
1. Rough in supply, drain and waste piping to the LC500 module as required for your installation.
NOTE: For modules with foot pedal option or for retrofit installations, refer to special rough-ins included with your LC500 module.
Figure 1a
LC500 L/F (floor waste)
Installation Instructions continue . . .
1/2 NPT HOT WATER INLET TO LAVATORY
1/2 NPT COLD WATER INLET TO LAVATORY
1-1/2 NPT LAVATORY DRAIN
1 NPT WATER
CLOSET INLET
(6) WALL ANCHORS AND BOLTS (SUPPLIED BY INSTALLER
(MM)