Bradley EXPRESS SS-3/AST/JUV, Express SS-3/AST/STD, Express SS-3/AST/WH97, Express SS Series Installation Instructions Manual

IMPORTANT
Read this entire installation manual to ensure proper installation, then file these instructions with the owner or maintenance department.
Flush all the water supply lines before making connections.
Wall anchors used must have a minimum pull-out rating of 1,000 lbs.
Product warranties may be found under "Product Information" on our web site at www.bradleycorp.com.
SS-3/AST/STD SS-3/AST/JUV
Express® Lavatory System SS-Series
(Standard and Juvenile Height)
Express® Lavatory Systems are ADA compliant.
Table of Contents
Pre-Installation Information . . . . . . . . . . . . . . . .2
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Installation Instructions . . . . . . . . . . . . . . . . 5-11
Cleaning and Maintenance . . . . . . . . . . . . . . . .12
Soap Dispenser Maintenance . . . . . . . . . . .13-14
Check Valve Troubleshooting . . . . . . . . . . . . . .14
Assembly of Components . . . . . . . . . . . . . .15-16
Metering Air Valve Maintenance . . . . . . . . . . .17
Metering Air Valve Troubleshooting . . . . . .17-18
Vernatherm™ Thermostatic Mixing Valve . . . .19
P.O. Box 309, Menomonee Falls, WI 53052-0309 TEL. 1-800-BRADLEY FAX 262-251-5817 http://www.bradleycorp.com
215-1238 Rev. C; EN 03-813 © 2004 Bradley Corporation Page 1 of 19 5/11/04
Installation Instructions
For Service Only
Express® Lavatory System SS-Series SS-3/AST/STD, SS-3/AST/JUV Installation Instructions - For Service Only
2
5/11/04 Bradley Corporation • 215-1238 Rev. C; EN 03-813
Pre-Installation Information
Barrier-free and ADA compliant - standard height mounting
The SS-3/AST/STD Express® Lavatory System must have a rim height of 34" above finished floor to be compliant with Americans with Disabilities Act (ADA). When mounted at 34" rim height, the Express® meets ADA, ANSI and UFAS requirements for barrier-free clearances, reaches and controls. Always check local codes and ordinances for compliance.
Barrier-free and ADA compliant - juvenile height mounting
The SS-3/AST/JUV Express® Lavatory System is compliant with Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities: Building Elements Designed for Children's Use; Final Rule.
Pushbutton and air valve
Each sprayhead is controlled by a pushbutton air valve, enabling each user to activate a single flow of water. Air valves use 0.5 gpm for a ten-second duration, meeting the ANSI/ASHRAE/IES 90A-1980 Standard.
Supplies required for installation:
• (8) 3/8" wall anchors, bolts and washers to mount frame and bowl to wall (minimum pull-out rating of 1,000 lbs.)
• 1/2" NPT hot and cold supply piping
• 1-1/2" NPT drain piping
Express® Lavatory System SS-Series
Installation Instructions - For Service Only SS-3/AST/STD, SS-3/AST/JUV
3Bradley Corporation • 215-1238 Rev. C; EN 03-813 5/11/04
8"
(203)
52" (1321)
64" (1626)
6"
(152)
80" (2032)
8" (203)
Radius
30"
(762)
8.5"
(216)
21"
(533)
30"
(762)
10" (254)
Radius
SS-3/AST/STD and SS-3/AST/JUV Express® Lavatory System Dimensions
Dimensions
continue . . .
68-1/4" (1732)
Express® Lavatory System SS-Series SS-3/AST/STD, SS-3/AST/JUV Installation Instructions - For Service Only
4
5/11/04 Bradley Corporation • 215-1238 Rev. C; EN 03-813
38"
(965)
34"
(864)
29"
(737)
11"
(279)
9"
(229)
6"
(152)
4"
(102)
30"
(762)
25"
(635)
11"
(279)
9"
(229)
6"
(152)
4"
(102)
34"
(864)
Standard Height
SS-3/AST/STD
Juvenile Height
SS-3/AST/JUV
SS-3/AST/STD and SS-3/AST/JUV Express® Lavatory System Dimensions
continued . . .
Express® Lavatory System SS-Series
Installation Instructions - For Service Only SS-3/AST/STD, SS-3/AST/JUV
5Bradley Corporation • 215-1238 Rev. C; EN 03-813 5/11/04
Installation Instructions
Step 1: Rough in
Note: See Figure 1a below (for Standard Height) and Figure 1b on page 6 (for Juvenile Height) when roughing in the Express®.
IMPORTANT: Flush the supply lines before making connections. Debris in supply
lines will cause the valves to malfunction.
IMPORTANT: Dimensions shown in Figure 1a are for Standard Height and in
Figure 1b for Juvenile Height.
1. Rough in 1/2" NPT hot and cold supply lines through wall at dimensions shown.
2. Rough in 1-1/2" NPT drain waste connection through wall at dimensions shown.
3. Install (8) 3/8" wall anchors with a minimum pull-out rating of 1,000 lbs. (supplied by installer) at the locations shown in Figures 1a and 1b.
(MM)
32"
(813)
28-5/8"
(727)
23-1/2"
(597)
11-3/8"
(289)
(8) 3/8" WALL ANCHORS WITH MINIMUM PULLOUT RATING OF 1,000 LBS.
38-1/2"
(978)
24-3/8"
(619)
2-3/4"
(70)
17-7/16"
(443)
38-1/2"
(978)
24-3/8"
(619)
4-3/8"
(111)
1/2" NPT HOT AND COLD SUPPLIES OR TEMPERED SUPPLY - STUB OUT 2" (50) FROM WALL
Finished Floor
CENTERLINE
15-1/4"
(387)
1-1/2" NPT DRAIN ­STUB OUT 3-1/2" (89) FROM WALL
Figure 1a
SS-3/AST/STD Express® Lavatory System (Standard Height)
Installation Instructions
continue . . .
Express® Lavatory System SS-Series SS-3/AST/STD, SS-3/AST/JUV Installation Instructions - For Service Only
6
5/11/04 Bradley Corporation • 215-1238 Rev. C; EN 03-813
(MM)
28"
(711)
24-5/8"
(625)
19-1/2"
(495)
11-3/8"
(289)
(8) 3/8" WALL ANCHORS WITH MINIMUM PULLOUT RATING OF 1,000 LBS.
38-1/2"
(978)
24-3/8"
(619)
2-3/4"
(70)
17-7/16"
(443)
38-1/2"
(978)
24-3/8"
(619)
4-3/8"
(111)
1/2" NPT HOT AND COLD SUPPLIES, OR TEMPERED SUPPLY
- STUB OUT 2" (50)
FROM WALL
FINISHED FLOOR
CENTERLINE
15-1/4"
(387)
1-1/2" NPT DRAIN ­STUB OUT 3-1/2" (89) FROM WALL
Figure 1b
SS-3/AST/JUV Express® Lavatory System (Juvenile Height)