Make sure that all water supply lines have been flushed and then completely turned off before beginning
installation. Debris in supply lines can cause valves to malfunction.
Turn OFF electrical power to the electrical outlets, then unplug all electrical units prior to installation. Electrical
power MUST remain off until installation is complete. After installation is complete, turn on the water supply
first, then turn on the electrical power.
Installer's hardware must be appropriate for wall construction. Wall anchors must have a minimum pull-out
rating of 1,000 pounds.
NOTICE
Overtightening fasteners can damage the Terreon material. Use caution when tightening bowl and sprayhead
fasteners.
IMPORTANT
Read this entire installation manual to ensure proper installation. When finished with the installation, file this
manual with the owner or maintenance department. Compliance and conformity to local codes and ordinances
is the responsibility of the installer.
Separate parts from packaging and make sure all parts are accounted for before discarding any packaging
material. If any parts are missing, do not begin installation until you obtain the missing parts.
Product warranties may be found under “Products” on our website at www.bradleycorp.com.
A3/8" Wall Anchors with a minimum pull-out force of 1,000 lbs. for Bowl2
B3/8" Wall Anchors with a minimum pull-out force of 1,000 lbs. for Mainframe4
C3/8" Wall Anchors for Base Frame, Standard Frame option only, minimum pull-out force not required2
D11/2" nominal copper tubing for Cold Supply, stub-out 2" from wall1
D21/2" nominal copper tubing for Hot or Tempered Supply, stub-out 2" from wall1
E1-1/2" NPT Drain, stub-out 2" from wall2
On the bowl back, measure the distance between the 3/4" bowl mounting holes. Divide this
F
measurement in half. Measure and mark this dimension on the wall to the left and the right of the
centerline. Install two 3/8" wall anchors with a minimum pull-out rating of 1,000 lbs (supplied by
Using a T20 torx key, remove the
fasteners securing the access panel to
A
the main frame, and remove the panel.
B
Scuff Base Frame
Standard Height
Frame Only
Anchoring the frame to a wall that is
not flat may cause the frame to bend,
making it difficult to reinstall the access
panels. If necessary, use shims to
compensate for wall distortion.
Once you have positioned the frame
such that it is level and flat against the
wall or shimmed, mount the frame to
the wall at four places using 3/8" bolts
and 1" min. O.D. washers.
When mounting the standard height
frame, mount the scuff base to the wall
at the same time using two additional
3/8" bolts and washers.
Install the Bowl
3
The sprayhead body has slotted holes for adjusting the fit-up with the
bowl and wall. The tailpiece on the waste tee has been rotated upward
for shipping purposes. Turn the tailpiece down to its proper position
before installing the bowl.
Attach the bowl to the frame using the
1/4-20 x 1/2" pan-head screws and
A
washers. Do not tighten screws.
Tighten the pan-head
screws. Do not overtighten.
C
Secure the
bowl to the wall
anchors with 3/8"
bolts and 1" min.
WARNING! The SS-3N/BIR3 Express must be connected to the 6 VDC battery. Connection to 110 VAC can
cause personal injury and will result in damage to the electronics. Connection of leads other
than shown may cause permanent damage to the sensor.
NOTICE! To avoid activating the sprayhead valve, make sure to connect the sensor cable plugs to the circuit board
before inserting the batteries into the battery holder. If the cable is connected or disconnected while the
batteries are installed, the station will activate and continue running for 75 seconds.
Loosen the compression nuts.
Push the sprayhead supply tubes firmly into
the tube connectors until they are fully seated
D
Tighten the compression nuts by hand.
Insert the batteries into
the battery holders.
B
Green Supply Tubing
Red Supply Tubing
Snap the sensor cable
Snap the battery cable
plugs into the female
This valve is NOT factory preset. Upon installation, the temperature of this
valve must be checked and adjusted to ensure delivery of a safe water
temperature. Water in excess of 110°F (43°C) may cause scalding.
Loosen the cap screw about 1/4"
(4–6 turns) and lift up the cover
A
(do not remove).
Using the cover, turn the
cartridge gently until desired
water temperature is reached. Do
B
not turn past stops as this may
damage the unit. Push the cover
down and tighten the screw.
Reinstall the valve bracket. Turn on the water supply to the Express and check for
leaks. Push the operating buttons of each station until all the air is purged from
C
the lines and water is flowing smoothly. Reinstall the access panel.
Material Description: Terreon is a densified solid surface material composed of bio based resin and is resistant to chemicals,
stains, burns and impact. Surface can be easily repaired with everyday cleansers or fine grit abrasives. Because Terreon is a
unique cast material, its aggregate flow and distribution, and shades of color can vary from product to product creating natural
characteristics.
Routine Cleaning: For regular cleaning, use mild neutral base cleaners.
Stubborn Stains: Remove tough stains with Soft-Scrub® and a green Scotch-Brite® pad or lightly sand in a circular motion with
240 grit wet/dry sandpaper. The finish can then be renewed with a maroon Scotch-Brite pad.
Scratches: Remove scratches with a green Scotch-Brite pad. The finish can then be renewed with a maroon Scotch-Brite pad.
Hard Water Deposits: Remove hard water deposits with a mild solution of vinegar and water. Always rinse the unit thoroughly
after cleaning.
Restoring the surface:
colors may require additional care and maintenance. For complete instructions on this additional maintenance, visit bradleycorp.com.
Repair Kits: Terreon repair kits are available. Contact your Bradley representative or distributor for part numbers and pricing.
Repair kits are made to order and have a shelf life of 30 days.
Use Hope’s® Perfect Countertop to refresh and protect the Terreon Solid Surface material. Dark Terreon
®
NOTICE! Do not use strong acid or alkaline chemicals and cleaners to clean Terreon. If these chemicals come in
contact with the surface, wipe them off immediately and rinse with soapy water. Avoid contact with harsh
chemicals such as paint remover, bleach, acetone, etc. Avoid contact with hot pans and objects.
Cleaning and Maintenance for Stainless Steel
Material Description: Stainless steel is extremely durable, and maintenance is simple and inexpensive. Proper care, particularly
under corrosive conditions, is essential. Always start with the simplest solution and work your way toward the more complicated.
Routine cleaning: Daily or as often as needed use a solution of warm water and soap, detergent, or ammonia. Apply the
cleaning solution per the manufacturer's instructions and always use a soft cloth or sponge to avoid damaging the finish.
Stubborn Stains: To remove stains from stainless steel use a stainless steel cleaner and polish such as Ball® stainless steel
cleaner or a soft abrasive. Always follow the manufacturer's instructions and apply in the same direction as the polish lines.
NOTICE! Never use ordinary steel wool or steel brushes on stainless steel. Always use stainless steel wool or
stainless steel brushes.
Fingerprints and Smears: To remove fingerprints or smears use a high quality stainless steel cleaner and polish in accordance
with the manufacturer's instructions. Many of these products leave a protective coating that helps prevent future smears and
fingerprints.
Grease and Oil: To remove grease and oil use a quality commercial detergent or caustic cleaner. Apply in accordance to the
manufacturer's instructions and in the direction of the polish lines.
Precautions: Avoid prolonged contact with chlorides (bleaches, salts), bromides (sanitizing agents), thiocyanates (pesticides,
photography chemicals, and some foods), and iodides on stainless steel equipment, especially if acid conditions exist.
NOTICE! Do not permit salty solutions to evaporate and dry on stainless steel.
The appearance of rust streaks on stainless steel leads to the belief that the stainless steel is rusting. Look for the actual source
of the rust in some iron or steel particles which may be touching, but not actually a part of the stainless steel structure.
NOTICE! Strongly acidic or caustic cleaners may attack the steel causing a reddish film to appear. The use of these
cleaners should be avoided.
Brand Names
Use of brand names is intended only to indicate a type of cleaner. This does not constitute an endorsement, nor does the
omission of any brand name cleaner imply inadequacy. Many products named are regional in distribution, and can be found in
local supermarkets, department and hardware stores, or through your cleaning service. It is emphasized that all products should
be used in strict accordance with package instructions.
WARNING Turn off water supplies to the unit before troubleshooting.
ProblemCauseSolution
An individual
operating
station fails
to shut off
and drips.
An individual
operating
station fails
to turn on or
off.
OPEN
VALV E
Debris is trapped between the
diaphragm and the valve seat.
A dead or faulty battery.Test the station to determine the cause and replace battery if required.
Faulty sensor eyes.Test the station to determine the cause and replace sensor eyes if required.
Faulty solenoid valve.Test the station to determine the cause and replace solenoid valve if required.
CLOSED
VALV E
Remove debris between diaphragm and the valve seat.
1. Disconnect the plug from the battery to the circuit board of the problem
valve.
2. Remove the three #8 Phillips-head screws that hold the solenoid valve
assembly together. Be careful not to lose the armature or spring.
3. Remove the diaphragm. Remove any particles that have been trapped
between the diaphragm and the valve seat. Rinse off the diaphragm and
inspect for damage. Make sure the center orifice and both small side orifices
are open.
4. Reassemble in reverse order (do not overtighten the Phillips-head screws
or the plastic valve body may crack). Tighten until the armature plate makes
contact with the plastic body.
5. Reconnect the battery plug. Turn on water supplies to the unit.
1. Disconnect the sensor cable from the circuit board of the problem valve.
Disconnect the sensor cable from the circuit board of an adjacent working
valve.
2. Connect the battery plug from the adjacent working valve to the problem
valve. Wait for ten seconds. Activate the problem station’s sensor ten times.
The station should turn on.
If the adjacent station turns on, and cycles normally, replace the battery.
1. Disconnect the plug from the battery to the circuit board of the problem
valve. Disconnect the plug from the battery to the circuit board of an
adjacent valve.
2. Connect the sensor cable from the adjacent working valve to the problem
valve. Activate the problem station’s sensor. The station should turn on.
If the adjacent station turns on, and cycles normally, replace the sensor eyes.
1. Remove the screw, circuit board and standoff from the problem valve.
Remove the battery holder.
2. With a good working battery, briefly contact the solenoid valve directly
with the battery. The contact should cause the valve to open. With the
battery holder removed, briefly contact the solenoid valve with the battery
in the position shown. This should cause the valve to close. If the valve
does not operate when directly contacted with a good battery, and the
solenoid valve has already been cleaned as outlined at the beginning of this
troubleshooting section, replace the solenoid valve.
If problems persist:
Pass your hand in front of the problem station, while at the same time looking to
see if the indicator light on the circuit board flashes (the indicator light is located
near the hole in the circuit board where the standoff is mounted). If it does not
flash, and the battery and sensor eyes have already been tested as outlined above,
the problem may be with the circuit board. Make a note of the numbers printed on
the circuit board, then contact your Bradley representative for assistance.
Before attempting to troubleshoot the valve or disassemble the components, check for the following conditions:
• If stop valves are used, make sure that they are fully open.
• Make sure that the hot and cold inlet pipes are connected properly, and that there are no cross-connections or
leaking stop valves.
• Check the hot water heater output to make sure that it is at least 10° F above the set temperature.
Be sure to close the appropriate shut-off valves prior to disassembly of the valve and reopen the valves after inspection
and repair is complete.
ProblemCauseSolution
External leaks.Damaged cartridge or O-rings.Replace cartridge with part number 269-1927
Improper water
Hot water supply is not 10° above desired set point.Increase hot water supply temperature
temperature or
temperature
fluctuation.
Valve temperature is not properly set.Adjust the temperature as shown on page 10, step 7.
Limited water flow. Dirt and debris have built up in the valve or strainer.1. Check to make sure both hot and cold supplies are
connected to the Navigator mixing valve and that
they have water flow.
2. Remove cover and U-clip. Remove the cartridge
and clean the strainer. It is not required to grease
cartridge, however if desired, use silicone grease
only. Do not use grease on check valves.
The soap valve will dispense vegetable/coconut oil liquid soaps, synthetic detergents, viscous lotion soaps, and
antiseptic solutions. A 10-15% con cen tra tion is rec om mend ed for veg e ta ble or co co nut oil liquid soaps. Before
filling, rinse out each soap tank with hot water to remove packing dust. Shake water out thor ough ly and allow to
dry. Do not over fill!
Leaf Spring will engage
Soap tank kit S65-291B (coal) includes:
• Coal Tank w/ Valve (S11-220B
• Leaf Spring (S39-350)
• Screw (160-385)
Soap Valve Repair Kit (S65-258) includes:
• Nut
• Spring
• Washer
• Plunger
Filler
Hole
when soap tank is
pushed into place.
Soap Blank
Coal (133-143B)
#10 Screw
Clean Soap Dispenser
NOTICE! Do not use abrasive cleansers to clean the soap tank. Abrasive cleaners can damage the surface.
Regular cleaning of the soap dispenser is recommended to ensure optimum performance and maximum service life. Cleaning the
soap dispenser monthly to remove soap residue, dirt, and other accumulations should become a regular part of your washroom
cleaning routine and general maintenance program.
Clean exterior: Use warm water and soap to clean the exterior of the soap dispenser. Dry with a soft cloth.
Clean interior: Inspect the interior of the tank for residue or coagulation of soap. If necessary, clean the tank according to the
following procedure:
1. Pour out any remaining soap in the tank.
2. Full the tank half-full of hot water and shake the tank to dislodge the soap residue.
3. Empty the water from the container and repeat steps 1 and 2 until the soap container is clean.
If rinsing alone does not remove the soap residue, place a small chain (24 inches long) into the tank with hot water and shake the
container until the chain dislodges the residue. Then remove the chain and rinse out the tank.
Clean internal components: Pump hot water through the soap dispenser until a clean flow of water comes out of the valve.
To change soap, pour out all of the soap from the dispenser and rinse with hot water several times until all residue is removed.
Pump the valve until clean water appears. Rinse the dispenser with ethyl alcohol; air dry before refilling.