Bradley CRS Series, Express Crescent CRS-2/IR/LSD, Express Crescent CRS-3/IRS/LSD Installation Manual

CRS-3/IR/LSD
Installation
CRS-2/IR, CRS-3/IR
Express® Crescent® Lavatory System
CRS-Series
Complies with Texas Accessibility Standards (TAS) for Juvenile Height applications.
Table of Contents
Dimensions ........................................................................ 2
Rough-Ins .......................................................................3-4
Supplies Required .............................................................5
Mount Bowl to Wall ............................................................ 5
Install Drain Spud ..............................................................5
Connect Supply .................................................................6
Electrical and Supply Connections .................................... 6
Adjust the temperature ......................................................7
Install Top Cover ................................................................7
Cleaning and Maintenance ................................................ 8
Solenoid Valve Troubleshooting and Repair Parts .............9
Navigator
®
Valve Troubleshooting and Repair Parts ........ 10
CRS-2/IR/LSD
3-station unit is shown throughout. 2-station is similar.
For soap system installation, refer to installation manual 215-1583.
WARNING
Flush all the water supply lines before making con nec tions. Debris in supply lines will cause the valves to malfunction.
Hardware supplied by installer must be appropriate for wall construction. Wall anchors used must have a minimum pull-out rating of 1,000 lbs.
IMPORTANT
Read this entire installation manual to ensure proper installation, then file these instructions with the owner or maintenance department.
Product warranties may be found under “Products” on our web site at www.bradleycorp.com.
215-1330 Rev. N; ECN 16-08-022 © 2016 Bradley Page 1 of 10 11/3/2016
Menomonee Falls, WI 53052 USA
800 BRADLEY (800 272 3539)
P.O. Box 309
+1 262 251 6000
bradleycorp.com
CRS-2/IR, CRS-3/IR Installation
Express® Crescent® Lavatory System Dimensions
14"
(356)
26"
(660)
48"
(1219)
48"
(1219)
33⁄8"
(86)
(mm)
173⁄8"
(441)
*34"
(864)
26"
(660)
8-1/2"
(216)
*20"
(508)
*37-3⁄8"
(949)
*Adjustments to Vertical Dimensions
for Various Rim Heights
Rim Height Application Adjustment
34" Adult Height ADA,
TAS Adult Height
32" TAS Ages 11 thru 14
or 15, Grades 6
thru 8 or 9
30" TAS Ages 4 thru 10 or
11, Grades Pre-K thru
5 or 6 & Proposed
Juvenile Height ADA
24" Preschool (required
by some local codes)
None, as
shown
Subtract 2"
Subtract 4"
Subtract 10"
2 11/3/2016 Bradley • 215-1330 Rev. N; ECN 16-08-022
Installation CRS-2/IR, CRS-3/IR
Rough-ins
WARNING Flush all the water supply lines before making connections. Debris in
supply lines will cause valves to malfunction.
Standard Height Mounting
Rim
Height
34"
(864)*
25-5/8"
(651)*
Trap Cover
(Optional)
1/2" NPT Drain
Stub Out 2" (51)
Centerline
of Fixture
(mm)
2"
(51)
6-1/2"
(165)
23-3/4"
(603)*
1/2" Nominal Copper
Tubing Hot and Cold
Supplies Stub Out 2" (51)
Floor
*Adjustments to Vertical Dimensions for Various Rim Heights
Rim Height Application Adjustment
34" Adult Height ADA, TAS Adult Height None, as shown
32" TAS Ages 11 thru 14 or 15, Grades 6 thru 8 or 9 Subtract 2"
30" TAS Ages 4 thru 10 or 11, Grades Pre-K thru 5 or 6 & Proposed Juvenile Height ADA Subtract 4"
24" Preschool (required by some local codes) Subtract 10"
Bradley • 215-1330 Rev. N; ECN 16-08-022 11/3/2016 3