Bradford-White Corp 238-46411-00A User Manual

Light Duty Commercial Electric
Voltage and Wattage Conversion Instructions
Conversion to be performed by a Qualified Service Person only.
Underwriters Laboratories Inc. recognizes this procedure as herein presented and no deviation from these
instructions are allowed.
LD-20L LD-50L LD-30L LD-50S LD-30R LD-65R LD-40L LD-80R LD-40S LD-120R
LDWH-6U LDWH-12U LDWH-20L LDWH-30L
LD-6U LD-15U LD-10U LD-20U LD-12U LD-30U LD-12UT
Page 1 of 5
The conversion procedure outlined in the instruction manual is to be executed only by Qualified Service
V
Personnel. Read these instructions first before proceeding with the conversion. The purpose of this instruction manual is to instruct about the changing of wattage and voltage for Light
Duty Commercial Electric water heaters manufactured by Bradford White Corporation. Underwriters Laboratories Inc. recognizes this procedure as herein presented and no deviation from these instructions are allowed.
Special factory prepared kits must be used for these conversions. Below is a list of the kits that have been prepared for the various wattages and voltages.
These instructions do not allow for the modification that adds or deletes the number of heating elements originally supplied with the water heater; therefore such a modification must not be attempted.
Voltage and Wattage conversion kit part numbers:
Element
Wattage
1500 1500 3000 265-46409-01 265-46409-0 5 265-46409-13 265-46409-16 2000 2000 4000 265-46409- 02* 265-46409-0 6 265-46409-05 265-46409-17 2500 2500 5000 265-46409- 03* 265-46409-0 7 265-46409-06 265-46409-18 3000 3000 6000 265-46409- 04* 265-46409-0 8 265-46409-14 265-46409-19 3500 3500 7000 N/A 265-46409-0 9 265-46409-07 N/A 4000 4000 8000 N/A 265-46409-1 0 265-46409-08 265-46409-20 4500 4500 9000 N/A 265-46409-1 1 265-46409-09 265-46409-21 5000 5000 10000 N/A 265-46409-1 2 265-46409-15 265-46409-22 5500 5500 11000 N/A 265-46409-46* 265-46409-10 265-46409-40 6000 6000 12000 N/A 265-46409-47* 265-46409-48 * 265-46409-23
* These k i ts c ontain onl y one (1) elem ent. These are non-simultaneous k i t s onl y.
Element Wattage
1500 1500 3000 265-46409-24 265-46409-4 1 265-46409-32 2000 2000 4000 265-46409-43 265-46409-2 4 265-46409-33 2500 2500 5000 265-46409-25 265-46409-4 3 265-46409-34 3000 3000 6000 265-46409-26 265-46409-2 5 265-46409-35 3500 3500 7000 265-46409-27 265-46409-2 6 N /A 4000 4000 8000 265-46409-29 265-46409-2 7 265-46409-36 4500 4500 9000 265-46409-30 265-46409-2 8 265-46409-37 5000 5000 10000 265-46409-31 265-46409-29 265-46409-38 5500 5500 11000 265-46409-44 265-46409-30 265-46409-42 6000 6000 12000 265-46409-45 265-46409-31 265-46409-39
Non-Simultaneous
Max W atta g e
Non-Simultaneous
Max W atta g e
Simultaneous
Max Wattage
Simultaneous
Max Wattage
120 208 240 277
Voltage
380 415 48 0
oltage
Tools required for conversion:
1. 1 ½" deep-well socket or wrench.
2. Phillips head screwdriver.
3. ¼" nut-driver or socket.
4. Thread lubricant.
!
WARNING
High voltage potential exposure. To avoid personal injury, be sure water heater is disconnected from power source prior to performing the procedure.
Page 2 of 5
Element(s) Removal:
1. Turn off electrical power to water heater, DISCONNECT FROM POWER SOURCE.
2. Drain water heater.
3. Remove element access cover(s).
Element
access cover
4. Remove Insulation.
Remove
screw
5. Remove thermostat(s) protector.
Remove
insulation
Remove
thermostat
protector
Page 3 of 5
6. Disconnect wire leads from element(s) terminal block.
Element
terminal block
Disconnect wire
leads from
element terminal
block
7. Remove element(s) from tank using 1½" deep well socket or wrench. Unscrew element(s) counter-clockwise to remove from tank.
Unscrew element(s)
counter-clockwise to
remove from tank
Element(s) Installation:
8. Check element terminal block for proper electrical rating.
Note: Some elements have a dual rating, so be sure to check all surfaces on element terminal block.
Check rating(s)
on element
Page 4 of 5
9. Apply new gasket(s) to new element(s) from conversion kit.
Note: Make sure gasket is seated flat against element flange without rolls or gaps.
Gasket
10. Thread new element(s) clockwise into tank. Tighten element(s) with a 1 ½" deep well socket or wrench. Do not over tighten. Over-tightening may damage gasket.
Note: Clean any debris from element(s) fitting to tank. Lubricate element(s) threads as needed with thread lubricant.
Element
flange
11. Be sure tank is filled with water and check for leaks.
12. Reconnect wire leads to element(s) terminal block.
13. Replace thermostat(s) protector and insulation.
14. Replace access cover(s).
15. Restore electrical power.
16. Place appropriate label (supplied with kit) so it covers electrical information on water heater rating plate.
Note: Be certain not to cover model number, serial number and capacity information.
Cover electrical information only
with appropriate overlay
Reconnect wires
leads to element(s)
terminal block
Thread
element(s)
clockwise
into tank
Water heater rating plate
Page 5 of 5
Loading...