Bradford White ES-3000-2-S-10, ES-3500-1-S-10, ES-3000-1-S-10, ES-3000-5-S-10, ES-3500-4-S-10 Installation Manual And Owner's Manual

...
ELECTRIC INSTANTANEOUS TANKLESS WATER HEATER
INSTALLATION GUIDE AND OWNERS MANUAL
ELEMENT CARTRIDGE
HEATER MODEL/ORDER REF. CARTRIDGE REF #
RELAY
PART#EX250B-
EX254B
FLOW RESTRICTOR
PART # EX0061-0.5-AER
CONTROL BOARD
EX0183DL-30A for
120V, 277V,
240V, 208V
REPLACEMENT PARTS FOR Single Point MODELS
CALL TECHNICAL SERVICE
@ 1-800-334-3393
COMPRESSION
SLEEVE 3/8
PART # EX68C
COMPRESSION
NUT 3/8
PART #EX68B
WARNING
BEFORE ATTEMPTING INSTALLATION OF THIS UNIT OR MAKING ANY
ADJUSTMENTS TO T HE UNIT, BE SURE CIRCUIT BREAKER IS OFF
TO PREVENT DANGER OF SERIOUS ELECTRIC SHOCK.
FAILURE TO GROUND THE SYSTEM MAY RESULT IN SERIOUS INJURY OR DEATH
INSTALLER/ CONSUMER RESPONSIBILITIES
READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO INSTALL OR OPERATE THIS WATER HEATING UNIT. IF THE SAFETY RULES ARE NOT
FOLLOWED, THE UNIT WILL NOT OPERATE PROPERLY AND COULD CAUSE
DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE. WARRANTY
OF THIS UNIT WILL DEPEND ON PROPER INSTALLATION AND OPERATION.
THE WARRANTY WILL BE VOID IF THE DESIGN HAS BEEN ALTERED IN ANY WAY
WHATSOEVER. THE MANUFACTURER OF THIS UNIT WILL NOT BE LIABLE
FOR ANY DAMAGES BECAUSE OF FAILURE TO COMPLY WITH THE INSTALLATION
AND OPERATING INSTRUCTIONS OUTLINED ON THE FOLLOWING PAGES.
THE INSTALLATION MUST CONFORM WITH THE INSTRUCTIONS IN THIS
MANUAL AND THE LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES,
WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE. THE
NATINOAL ELECTRICAL CODE IS AVAILABLE FROM WRITING
UNDERWRITERS LABORATORIES, 333 PFINGSTEN RD.,
NORTHBROOK, IL. 60062
IF ASSTANCE IS REQUIRED OR ANY QUESTIONS RELATING
TO THE INSTALLATION OR PERFORMANCE OF THIS UNIT ARISE,
PLEASE CONTACT
TECHNICAL SERVICE TOLL FREE:1-800-334-3393.
HAVE THE INFORMATION LISTED BELOW BEFORE CALLING:
MODEL NO.___________SERIAL NO.___________INSTALLATION DATE_____
SINGLE POINT
MODELS COVERED:
ES-2400-1-S-10 ES-3000-1-S-10 ES-3000-2-S-10 ES-3000-5-S-10 ES-3500-1-S-10 ES-3500-4-S-10 ES-4100-2-S-10 ES-4100-5-S-10 ES-5500-4-S-10
ES-2400-1-S-10 120V EX610SP ES-3000-1--S-10 120V EX480SP ES-3500-1-S-10 120V EX410SP ES-3000-2-S-10 120V EX1440SP ES-4100-2-S-10 208V EX1050SP ES-3500-5-S-10 240V EX1650SP ES-4100-5-S-10 277V EX1870SP ES-3000-5-S-10 277V EX2500SP ES-5500-4-S-10 240V EX1050SP
INSTALL
THIS WAY UP
ONLY !
UP
relay
PLUMBING CONNECTIONS
1) The unit is supplied with 3/8’’ compression fittings. USE THESE: DO NOT USE THREADED PIPE FITTINGS. DO NOT USE PIPE DOPE OR TEFLON TAPE ON THIS INSTALLATION. Ensure the inlet filter supplied with this unit is in place.
2) Ensure that the pipes are correctly aligned with the inlet and outlet bosses to avoid excessive stress on the heater body molding of the unit.
NOTE: Run water through the supply pipe to remove all debris from the pipe before connecting to the unit. Failure to do so could damage the flow switch.
3) Install isolating valves (shut-off type),or equivalent on both inlet and outlet pipes. This allows the unit to be isolated for maintenance purposes. (Fig. 2)
4) When all plumbing is complete, inspect the system for water leaks at all plumbing connections. If a water leak is present take corrective action. If a water leak is at the compression fitting, slowly tighten compression nut until the water leaks ceases. Fully open both inlet and outlet shut-off valves. Run all hot water outlets fed by this heater one at a time until the water flow is continuous and free from gulping and all visible air pockets.
NOTE:
ALL PLUMBING AND MOUNTING MUST BE COMPLETED
BEFORE PROCEEDING WITH THE
ELECTRICAL HOOK-UP.
TEST THE INSTALLATION FOR LEAKS BEFORE
CONNECTING THE ELECTRICAL SUPPLY.
.
Inlet filter
Loading...