Bradford White D-80T-250-3NA, D-38T-155-3N+, D-100L-270-3NA, D-75T-160-3N, D-100L-250-3NA User Manual

...
Commercial Flue Damper Electronic Ignition
Gas Water Heater
FEATURING:
Photo is of
D-75T-125-3N
The Commercial Flue Damper Models feature:
ICON HD
Intelligent proven design combines temperature control,
diagnostic codes, and system ignition functions into a single control board with a digital LCD display. Control panel cover tilts down for ease of wiring and service.
Operation Mode—Two different digitally displayed operation modes have
the capability of adjusting the temperature setting up to 180°F (82°C), and adjusting the degree setting (ºF to ºC, or ºC to ºF).
Service Mode—Eight different digitally displayed service modes can be
easily cycled through by pressing the select button. There is the capability of adjusting the temperature setting up to 180°F (82°C), adjusting the degree setting (ºF to ºC, or ºC to ºF), locking the maximum temperature setting that can be adjusted in operation mode, displaying the average water temperature (if water heater has two sensors), displaying the upper temperature sensor, displaying the lower temperature sensor, displaying the flame current of the pilot flame, and displaying diagnostic codes.
Electronic Ignition—High voltage, low current electricity is sent to the pilot
electrode initiating a spark to ignite the pilot gas. This results in savings of pilot gas during stand-by periods because the pilot flame only operates when there’s a call for heat.
Automatic Flue Damper—Reduces stand-by loss, saving gas consumption
and improving overall efficiency.
Factory Installed Hydrojet
®
Sediment Reduction System—Cold water
inlet sediment reducing device helps prevent sediment build up in the tank.
Vitraglas
superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglas
®
Lining—An exclusively engineered enamel formula that provides
®
) is fused to the steel surface by firing at a temperature of
over 1600°F (871°C).
Insulation System—Non-CFC foam covers the sides and top of the tank,
reducing heat loss. This results in less energy consumption, improved efficiencies, and jacket rigidity.
Water Connections—1
1
⁄2" (38mm) NPT factory-installed true dielectric fittings
extend water heater life and simplify water line connections.
Hand Hole Cleanout—Allows inspection of tank interior and facilitates the
removal of sediment deposits.
E.C.O.—An automatic reset Energy Cut Out (E.C.O.) shuts off all gas in event
of an overheat condition. This automatically resets when operation conditions are back to normal.
Protective Magnesium Anode Rods—Provide added protection against
corrosion for long-term, trouble-free service.
Sanitizing Capability—Temperature setting up to 180°F (82°C).
ASME Code Available on all Models Above 200,000 BTU/Hr.
NSF Construction Available.
Low NOx Construction Available.
North Carolina Code Compliant.
T&P Relief Valve—Installed.
Low Restrictive Brass Drain Valve—Durable tamper proof design.
Design certified by CSA International.
3 or 5-Year Limited Tank Warranties / 1-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada, and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Vitraglas
and Hydrojet® are registered trademarks of Bradford White® Corporation.
735-C-0819
3
/
4
3
/
4
3
/
4
3
/
4
3
/
4
1
3
/
4
1 1 1 1 1 1
3
/
4
1
3
/
4
1 1 1 1 1 1
Relief Valve Open.
in.
C/L
Water Conn.
in.
4 4 4 4 4 4 4
4 10 10 10 10 10
4
4
4
4
4
4 10 10 10
C/L
Water Conn.
mm.
4
4
4
4
4
4
4
4 10 10 10 10 10
4
4
4
4
4
4 10 10 10
Commercial Flue Damper Electronic Ignition Gas Water Heater
Electronic Ignition Models
NATURAL GAS AND LIQUID PROPANE GAS
Model
Number
D-38T-155-3N+ D-65T-370-3N(A) D-65T-399-3N(A)** D-75T-125-3N D-75T-160-3N D-75T-300-3N(A) D-80T-180-3N D-80T-199-3N D-80T-250-3N(A) D-80T-425-3N(A) D-80T-505-3N(A) D-100L-199-3N D-100S-199-3N D-100T-199-3N D-100L-250-3N(A) D-100S-250-3N(A) D-100T-250-3N(A) D-100L-270-3N(A)** D-100L-300-3N(A)
Model
Number
D-38T-155-3N+ D-65T-370-3N(A) D-65T-399-3N(A)** D-75T-125-3N D-75T-160-3N D-75T-300-3N(A) D-80T-180-3N D-80T-199-3N D-80T-250-3N(A) D-80T-425-3N(A) D-80T-505-3N(A) D-100L-199-3N D-100S-199-3N D-100T-199-3N D-100L-250-3N(A) D-100S-250-3N(A) D-100T-250-3N(A) D-100L-270-3N(A)** D-100L-300-3N(A)
(A) = ASME Code Available (F) = Front Water Connection (T) = Top Water Connection ** = Available in Natural Gas Only + = Fiberglass Insulation For Propane (LP) Gas models change
suffix “N” to “X”. 220V/50Hz Available - Consult factory.
Nominal
Gal.
Capacity
U.S. Gal.
38 65 65 75 75 75 80 80 80 80
80 100 100
98 100 100
98 100 100
Nominal
Liter
Capacity
144 246 246 284 284 284 303 303 303 303 303 379 379 371 379 379 371 379 379
Imp. Gal.
31 54 54 62 62 62 67 67 67 67 67 83 83 82 83 83 82 83 83
LP
BTU/Hr.
BTU/Hr.
Input 40°F 100°F 140°F
Input
155,000
155,000
370,000
370,000 399,999 125,000 160,000 300,000 180,000 199,999 250,000 425,000 505,000 199,999 199,999 199,999 250,000 250,000 250,000 270,000 300,000
Input
108.4
117.2
124.5
148.0
– 125,000 155,000 300,000 180,000 199,999 235,000 425,000 505,000 199,999 199,999 199,999 250,000 250,000 235,000
– 300,000
LP kW
kW
Input 22°C 56°C 78°C
45.4
45.4
108.4 –
36.6
36.6
45.4
46.8
87.9
87.9
52.7
52.7
58.6
58.6
68.9
73.2
124.5
148.0
58.6
58.6
58.6
58.6
58.6
58.6
73.2
73.2
73.2
73.2
68.9
73.2 –
79.0
87.9
87.9
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
GPH Recovery
at Degree Rise*
150
376
359
897
388
970
121
303
155
389
291
727
175
436
194
485
242
606
412
1030
489
1178
194
485
194
485
194
485
242
606
242
606
242
606
262
655
291
727
LPH Recovery
at Degree Rise*
556
1391
1359
3395
1469
3671
458
1147
572
1431
1101
2752
662
1650
734
1836
916
2294
1559
3899
1783
4459
734
1836
734
1836
734
1836
916
2294
916
2294
916
2294
992
2479
1101
2752
107 256 277
86 111 208 124 139 173 294 337 139 139 139 173 173 173 187 208
397 969
1048
326 409 787 469 526 655
1113 1276
526 526 526 655 655 655 708 787
A
Floor
to
Vent
Conn.
in.
1
55
5
77
/
5
77
/
3
76
/
3
76
/
7
79
/
3
76
3
76
3
76
5
88
/
5
88
/
15
77
1
75
/
15
88
15
77
1
75
/
15
88
15
77
15
77
A
Floor
to
Vent
Conn.
mm.
1400 1964 1964 1935 1935 2018 1940 1940 1940 2243 2243 1980 1918 2259 1980 1918 2259 1980 1980
C
D
B
Vent
Jacket
Size
Dia.
in.
in.
1
/
8
28
/
4
6
1
28
/
1
28
/
1
28
/
1
28
/
1
28
/
1
28
/
1
28
/
1
28
/
1
28
/
1
28
/
1
30
/
1
28
/
1
28
/
1
/
30
1
28
/
1
28
/
1
/
30
1
/
30
B
Jacket
Dia.
mm.
718 718 718 718 718 718 718 718 718 718 718 768 718 718 768 718 718 768 768
8
4
8
4
5
4
6
4
7
4
6
4
6
4
6
4
10
4
10
4
6
4
6
4
6
4
6
4
6
4
6
4
6
4
7
4
C Vent Size
mm.
152 203 203 127 152 178 152 152 152 254 254 152 152 152 152 152 152 152 178
16
16
16
16
16
/
8
/
8
/
8
16
16
/
16
2
/
16
/
16
2
/
16
/
16
/
16
Floor
to
T&P
Conn.
in.
3
38
1
58
1
58
5
58
5
58
1
58
15
59
15
59
15
59
3
68
3
68
3
60
3
64
15
70
3
60
3
64
15
70
3
60
3
60
D
Floor
to
T&P
Conn.
mm.
984 1476 1476 1481 1481 1476 1522 1522 1522 1732 1732 1535 1635 1802 1535 1635 1802 1535 1535
E
Floor
to
Gas
Conn.
in.
11
/
4
8
/
16
1
/
8
6
/
4
1
/
8
6
/
4
11
/
16
8
/
16
11
/
16
8
/
16
11
/
8
8
/
16
11
/
16
8
/
16
11
/
16
8
/
16
11
/
16
8
/
16
1
/
16
6
/
4
1
/
16
6
/
4
11
/
8
8
/
16
11
/
8
8
/
16
11
/
16
8
/
16
11
/
8
/
16
8
11
/
8
8
/
16
11
/
16
8
/
16
11
/
8
/
16
8
11
/
8
/
16
8
E
Floor
to
Gas
Conn.
mm.
221 159 159 221 221 221 221 221 221 159 159 221 221 221 221 221 221 221 221
F
Floor
to Top
of
Heater
in.
1
47
/
16
5
68
/
16
5
68
/
16
1
69
/
16
1
69
/
16
13
69
/
5
68
/
16
5
68
/
16
5
68
/
16
5
79
/
16
5
79
/
16
15
68
/
5
68
/
16
5
79
/
16
5
/
16
68
5
68
/
16
5
79
/
16
5
/
16
68
5
/
16
68
F
Floor
to Top
of
Heater
mm.
1195 1760 1760 1754 1754 1773 1735 1735 1735 2015 2015 1751 1735 2015 1735 1735 2015 1735 1735
G
Floor
Floor to
to Top
Water
Water
Conn.
Conn.
in.
23
– – –
70
37
70
37
16
70 70 70
– –
1
70
16
/
2
81
1
81
/
2
1
/
2
70
81
1
81
/
2
70 70
G
Floor
Floor to
to Top
Water
Water
Conn.
Conn.
mm.
– –
– 1778 1778
– 1778 1778 1778
– 1791 2057 2070 1791 2057 2070 1778 1778
K
Cold
in.
32 32
15
15
32 23 23 23 32 32 27 24 23 27 24 23 27 27
K
Cold
mm.
592 962 962 964 964 962 597 597 597 962 962 695 629 597 695 629 597 695 695
L
Floor to
Water Conn.
Hot
in.
3
5
38
/
4
/
16
1
7
58
/
8
/
8
1
7
58
/
8
/
8
5
58
/
16
/
16
5
58
/
16
/
16
1
7
58
/
8
/
8
15
1
59
/
16
/
2
15
1
59
/
16
/
2
15
1
59
/
16
/
2
3
7
68
/
16
/
8
3
7
68
/
16
/
8
3
3
60
/
8
/
8
3
3
64
/
8
/
4
15
1
70
/
16
/
2
3
3
/
8
/
8
60
3
3
64
/
8
/
4
15
1
70
/
16
/
2
3
3
/
8
/
8
60
3
3
/
8
/
8
60
L
Floor to
Water Conn.
Hot
mm.
984 1476 1476 1481 1481 1476 1522 1522 1522 1732 1732 1534 1635 1802 1534 1635 1802 1534 1534
C/L
of Water Conn.
in.
1
14
/
1
14
/
19 19 19
23 21 19 23 21 19 23 23
C/L
of Water Conn.
mm.
368 368
483 483 483
584 533 483 584 533 483 584 584
Water Conn.
Conn.
NPT
in.
1
1
/
2 (F)
1
1
/
2 (F)
3/4 (LP
1
1
/
2 (F)
1
2
1
/
2 (T&F)
1
2
1
/
2 (T&F)
1
1
/
2 (F)
1
1
/
2 (T&F)
1
1
/
2 (T&F)
1
1
/
2 (T&F)
1
1
/
2 (F)
3/4 (LP
1
1
/
2 (F)
3/4 (LP
1
1
/
2 (T&F)
1
1
/
2 (T&F)
1
1
/
2 (T&F)
1
/
2 (T&F)
1
1
1
/
2 (T&F)
1
1
/
2 (T&F)
1
/
2
1
(T&F)
1
/
2 (T&F)
1
Water Conn.
Conn.
NPT
Size
mm.
mm.
38
(F)
25(N
38 (F)
19 (LP
38 (F) 38 (T&F) 38 (T&F)
38 (F) 38 (T&F) 38 (T&F) 38 (T&F)
25(N
38 (F)
19 (LP
25(N
38 (F)
19 (LP
38 (T&F) 38 (T&F) 38 (T&F)
38 (F) 38 (T&F) 38 (T&F)
38 (F)
38 (F)
Depth
in. Std. ASME
1
32
/
2
3
33
/
8
3
33
/
8
1
32
/
2
3
32
/
8
3
33
/
8
1
32
/
2
1
32
/
2
1
32
/
2
1
34
/
2
1
34
/
2
1
34
/
2
1
32
/
2
1
32
/
2
1
/
2
34
1
32
/
2
1
32
/
2
1
/
2
34
1
/
2
34
Depth
mm. Std. ASME
826 845 845 826 822 845 826 826 826 876 876 876 826 826 876 826 826 876 876
* Recoveries are based on Natural Gas Input and 80% Thermal Efficiency. Low NOx models are not available for inputs over 399,999 BTU/Hr.
For Low NOx compliance, place an “E” following the BTU input identifier of the model number.
Example: D-75T-125E-3N Amperage Draw = .5 for damper models/less than 4 for induced draft models. Power Vent Kits – available for inputs from 125,000 to 505,000 BTU/Hr. For 5 year models change suffix from “3” to “5”.
Gas
Size
in.
3
1(N
1(N)
3
3
3
3
3
3
1(N
1(N
3
3
3
3
3
3
3
3
Gas
19
25 19 19 19 19 19 19
19 19 19 19 19 19 19 19
Approx.
Shipping
Weight
(lbs.)
)
)
)
438 665 665 520 520 590 540 540 540 750 750 725 667 610 725 667 610 725 725
Approx.
Shipping
Weight
(kg.)
199 302 302 236 236 268 245 245 245 340 340 329 302 277 329 302 277 329 329
720 720
645
590 800 800
765 702 690 765 765
327 327
393
268 363 363
347 318 313 347 347
– –
– –
– – –
– –
– –
– – –
/
4
)
/
4
/
4
/
4
/
4
/
4
/
4
)
)
/
4
/
4
/
4
/
4
/
4
/
4
/
4
/
4
)
)
) )
) )
Loading...
+ 2 hidden pages