C-SW2-TW50T10FBN
FEATURING:
Residential Power Vent Combi1™ TTW
Gas Water Heater System
The Combi1™ TTW® FVIR Defender Safety System® Models Feature
Photo is of
(50T model, only):
■ Advanced ScreenLok
is designed to prevent ignition of flammable vapor outside of the water heater.
■ Flammable Vapor Sensor—Electronic sensor prevents burner operation if
flammable vapors are detected. The sensor will also prevent operation if there is
ongoing flammable vapors burning inside the combustion chamber.
■ Maintenance Free—Regular cleaning of air inlet openings or flame arrestor is
not required under normal conditions.
■ Sight Window—Offers a view of the pilot and burner operation.
All Combi1
™
TTW® Models Feature
■ Internal Single Wall Heat Exchanger—1
steel coil.
-- 1" (25mm) NPT Solar Collector Supply and Return Connections.
■ Low Heat Exchanger Head Loss—Up to 10 GPM (38L) flow, with less than 5ft.
(1.5m) of head loss. Greatly reduces the required pump size for heat exchange.
■ Honeywell Self Diagnostic Electronic Gas Control —Intelligent gas control
with spark to pilot ignition system eliminates the constant burning pilot. This
results in savings of pilot gas during stand by periods (120 VAC).
-- Enhanced Performance—Proprietary algorithms provide enhanced First Hour
Rating and tighter temperature differential.
-- Advanced Temperature Control System—Microprocessor constantly monitors
and controls burner operation to maintain accurate water temperature levels.
-- Intelligent Diagnostics—An exclusive green LED light prompts the installer
during start-up and provides ten different diagnostic codes to assist in
troubleshooting.
■ Factory-Installed Hydrojet
device that also increases first hour rating of hot water while minimizing
temperature build-up in tank.
■ Vitraglas
®
Lining—An exclusively engineered enamel formula that provides
superior tank protection from the highly corrosive effects of hot water. This
formula (Vitraglas
1600°F (871°C).
■ Horizontal and Vertical Venting—With 3" (76mm) or 4" (102mm) PVC, ABS or
CPVC (Maximum equivalent vent lengths on reverse side).
■ Insulation System—2" (51mm) Non-CFC foam insulation covers the sides and
top of the tank, reducing heat loss. This results in less energy consumption,
improved efficiencies, and jacket rigidity.
■ Pedestal Base.
■ Water Connections—3⁄4" (19mm) NPT factory-installed true dielectric fittings
extend water heater life and simplify water line connections.
■ Two Protective Anode Rods.
■ T&P Relief Valve—Installed.
■ Low Restrictive Brass Drain Valve—Durable tamper proof design.
■ Thermostatic Mixing Valve (ASSE Approved)—Included.
®
Technology Flame Arrestor Design—Flame arrestor
1
⁄2" (38mm) O.D. glass coated (Vitraglas®)
®
Total Performance System—Sediment reducing
®
) is fused to the steel surface by firing at a temperature of over
®
10-Year Limited Tank and Heat Exchanger Warranties / 6-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada, and Puerto Rico. Some states do not allow limitations on warranties. See complete
copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821;
6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117;
7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186;
2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Defender Safety System
®
, ScreenLok®, TTW®, Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation.
542-B-0917-A
Residential Power Vent Combi1™ TTW® Gas Water Heater System
Combi1™ TTW® Models
NATURAL GAS AND LIQUID PROPANE GAS
Model
Number
C-SW2-TW50T10FBN
C-SW2-TW75T10BN
Model
Number
C-SW2-TW50T10FBN
C-SW2-TW75T10BN
Capacity
U.S.
Gal.
45
72 76,000 68 26 3 313341⁄2 601⁄453 641⁄4 311553
Capacity
Nat.
BTU/Hr.
Imp.
Input
Gal.
38 67,000 60,000 65 22
61
Nat.
Liters
170 246 1673 559 1273 298 786 1270 1432 1543 679 1107617.519.6 272
272 22.3 306
kW
Input
LP
BTU/Hr.
Input
75,500
LP
kW
Input
22.1
Nat.
U.S.
GPH
82
Liters/
Recovery
90°F Rise*
Nat.
Imp.
GPH
60
69
Recovery
50°C Rise*
Nat.
Hour
310
LP
U.S.
GPH
65
81
LP
Liters/
Hour
A
B
Jacket
Vent
Dia.
Conn.
in.
in.
7
⁄8
3
⁄8
A
B
Jacket
Vent
Dia.
Conn.
mm.
mm.
1737 660 76 1346 389 868 1549 1530 1632 787 142
LP
Imp.
GPH
54
67
Floor to
Floor to
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
80% Recovery Efficiency
C
Vent
Size
in.
3 243563⁄850 263⁄4603⁄4113⁄4 311⁄2501⁄872
C
Vent
Size
mm.
D
Floor to
T&P
Conn.
in.
D
Floor to
T&P
Conn.
mm.
E
Floor
to
Gas
Conn.
in.
E
Floor
to
Gas
Conn.
mm.
F
Floor to
Exchanger
Inlet
in.
F
Floor to
Exchanger
Inlet
mm.
G
Floor to
Exchanger
Outlet
in.
G
Floor to
Exchanger
Outlet
mm.
H
Floor
to
Heater
Top
in.
H
Floor
to
Heater
Top
mm.
Water
Conn.
Water
Conn.
Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix “BN” to “SX”.
* Based on manufacturers rated recovery efficiency.
110 VAC Required for Power Venting / 110 VAC, 60Hz., 3.1 Amperes.
Heat Exchanger
Head Loss
GPM
C
Ft. of
Hd. Loss
2
0.03
5
0.20
8
0.51
10
0.80
12
1.15
K
C-SW2-TW50T
C-SW2-TW75T
Max. Equivalent Length
Min. Equivalent Length
Number 1
of 2
90ϒ Elbows 3
Vent Pipe4"Vent Pipe
†
Subtract 5ft. for each additional 90° elbow.
† For high altitude installations, consult the
installation instructions.
** C-SW2-TW75T maximum 3" (76mm) vent
length is 50ft. (15m).
J
Floor
to
in.
J
Floor
to
mm.
3"
60 ft.**
7 ft.
55 ft.
50 ft.
45 ft.
K
Depth
in.
K
Depth
mm.
†
180 ft.
15 ft.
175 ft.
170 ft.
165 ft.
Approx.
Shipping
Weight
lbs.
Approx.
Shipping
Weight
kg.
A
General
Meets NAECA Requirements.
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All potable water connections are 3/4"
(19mm) NPT on 11" (279mm) centers. All heat exchanger connections are 1" (25mm) NPT. All gas connections 1⁄2" (13mm). All models design certified by
CSA International (formerly AGA/CGA), ANSI Z21.10.1 and or 10.3 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into the potable water side. The potable side of this unit may NEVER
be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. The heat exchanger side of the
unit may be used in space heating applications.
B
D & G
J
H
Supply Temperature
Return Temperature
Differential
Flow Rate (50 Gal.)
Net Output (50 Gal.)
Flow Rate (75 Gal.)
Net Output (75 Gal.)
140°F
120°F
20°F
4.1 GPM
35,000 BTU/Hr.
4.1 GPM
35,000 BTU/Hr.
120°F
100°F
20°F
4.6 GPM
39,500 BTU/Hr.
5.6 GPM
47,500 BTU/Hr.
* These values were obtained using 180°F stored tank
F
E
temperature.
Net Output is the space heating capacity based on
normal piping and pickup allowance of 15%.
Actual values may vary based on circulator flow rate,
number of zones, water and space heating demands.
Numbers subject to change.
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Ambler, PA
Sales 800-523-2931 l Fax 215-641-1670 / Technical Support 800-334-3393 l Fax 269-795-1089 l Warranty 800-531-2111 l Fax 269-795-1089
International: Telephone 215-641-9400 l Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-203-0600 l Fax 905-636-0666 / www.bradfordwhite.com
100°F
80°F
20°F
4.6 GPM
39,500 BTU/Hr.
5.6 GPM
47,500 BTU/Hr.
©2017, Bradford White Corporation. All rights reserved.
Printed in U.S.A.542-B-0917-A