Bradford White C-DW2-TW50T10FBN, C-DW2-TW75T10BN User Manual

Residential Power Vent Combi2™TTW
®
Gas Water Heater System
The Combi2™TTW®FVIR Defender Safety System®Models Feature (50T model, only):
Advanced ScreenLok
®
Technology Flame Arrestor Design—Flame arrestor
is designed to prevent ignition of flammable vapor outside of the water heater.
Flammable Vapor Sensor—Electronic sensor prevents burner operation if
flammable vapors are detected. The sensor will also prevent operation if there is ongoing flammable vapor burn inside the combustion chamber.
Maintenance Free—Regular cleaning of air inlet openings or flame arrestor is
not required under normal conditions.
Sight Window—Offers a view of the pilot and burner operation.
All Combi2™ TTW®Models Feature
Internal Double Wall Heat Exchanger—11⁄2" O.D. glass coated (Vitraglas®) steel
coil ensures separation of potable water and heating fluid.
-- 3/4" NPT Solar Collector Supply and Return Connections.
Low Heat Exchanger Head Loss—Up to 8 GPM flow, with less than 6 ft. of
head loss. Greatly reduces the required pump size for heat exchange.
Honeywell Self Diagnostic Electronic Gas Control—Intelligent gas control with
spark to pilot ignition system that eliminates the constant burning pilot. This results in savings of pilot gas during stand-by periods (120 V.A.C.).
-- Enhanced Performance—Proprietary algorithms provide enhanced First Hour
Delivery ratings and tighter temperature differentials.
-- Advanced Temperature Control System—Microprocessor constantly monitors
and controls burner operation to maintain accurate water temperature levels.
-- Intelligent Diagnostics—An exclusive green LED light prompts the installer
during start-up and provides ten different diagnostic codes to assist in troubleshooting.
Factory installed Hydrojet
®2™
Total Performance System—Cold water inlet
sediment reducing device helps prevent sediment build up in tank. Increases first hour delivery and minimizing temperature build up in tank.
Vitraglas
®
Lining—Bradford White tanks are lined with an exclusively
engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglas
®
) is fused to the
steel surface by firing at a temperature of over 1600°F (871°C).
Horizontal and Vertical Venting—With 3" or 4" PVC, ABS OR CPVC
(Maximum equivalent vent lengths on reverse side).
2" Non-CFC Foam Insulation—Covers the sides and top of tank, reducing the
amount of heat loss. This results in less energy consumption, improved operation efficiencies and jacket rigidity.
Pedestal Base.
Water Connections—3/4" NPT factory installed true dielectric fittings.
Two Protective Anode Rods.
T&P Relief Valve—Installed.
Low Restriction Brass Drain Valve—Durable tamper proof design.
Thermostatic Mixing Valve (ASSE Approved)—Included.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Defender Safety System
®
, ScreenLok®, TTW®, Vitraglas®and Hydrojet®are registered
trademarks of Bradford White
®
Corporation.
547-B-0715-A
10-Year Limited Tank and Heat Exchanger Warranties / 6-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater.
Photo is of
C-DW2-TW50T10FBN
FEATURING:
NATURAL GAS AND LIQUID PROPANE GAS
Model
Number
Capacity
Combi2™ TTW® Models
72 76,000 68 26 3 315307⁄
8
601⁄
4
53 641⁄4311553
F
Floor to
Exchanger
Inlet
in.
G
Floor to
Exchanger
Outlet
in.
H
Floor
to
Heater
Top
in.
K
Depth
in.
J
Floor
to Water Conn.
in.
Approx.
Shipping
Weight
lbs.
E
Floor
to
Gas
Conn.
in.
A
Floor to
Vent
Conn.
in.
D
Floor to
T&P
Conn.
in.
C Vent Size
in.
B
Jacket
Dia.
in.
Gal.
U.S.
Input
Nat.
BTU/Hr.
82
Input
LP
BTU/Hr.
GPH
Nat. U.S.
Recovery
90°F Rise*
75,500
Model
Number
Capacity
Liters
272 22.3
306
F
Floor to
Exchanger
Inlet
mm.
G
Floor to
Exchanger
Outlet
mm.
H
Floor
to
Heater
Top
mm.
K
Depth
mm.
J
Floor
to Water Conn.
mm.
Approx.
Shipping
Weight
kg.
E
Floor
to
Gas
Conn.
mm.
A
Floor to
Vent
Conn.
mm.
D
Floor to
T&P
Conn.
mm.
C Vent Size
mm.
B
Jacket
Dia.
mm.
Input
Nat.
kW
22.1
Input
LP kW
Hour
Nat.
Liters/
Hour
LP
Liters/
310
Recovery
50°C Rise*
1737 660 76 1346 389
784 1549 1530 1632 787 143
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed 80% Recovery Efficiency
45
61
Gal.
Imp.
38 67,000 60,000 65 22
7
8
3
8
3 24528 563⁄
8
501⁄
8
263⁄
4
603⁄
4
113⁄
4
501⁄
8
72
81
GPH
LP
U.S.
65
69
GPH
Nat.
Imp.
60
67
GPH
LP
Imp.
54
C-DW2-TW50T10FBN C-DW2-TW75T10BN
C-DW2-TW50T10FBN C-DW2-TW75T10BN
170
246 1673 559 1273 298 711 1273 1432 1543 679 1117617.519.6 272
Residential Power Vent Gas Water Heater System
Meets NAECA Requirements General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All potable water and heat exchanger connections are 3⁄4" NPT (19mm) on 11" (203mm) centers. All gas connections 1⁄2" (13mm).
All models design certified by CSA International (formerly AGA/CGA), ANSI Z-21.10.1 and or 10.3 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into the potable water side. The potable side of this unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. The heat exchanger side of the unit may be used in space heating applications.
Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "BN" to "SX". *Based on manufacturers rated recovery efficiency. 110 V.A.C Required for Power Venting / 110 V.A.C., 60HZ, 3.1 Amperes. CAEF is .66 (TW50) and .64(TW75) CAAFUE% is 82.0
C
A
J
H
E
F
D & G
Subtract 5ft. for each additional 90° elbow. †For high altitude installations, consult the
installation instructions. **C-DW2-TW75T maximum 3" vent length is
50ft.
3"
Vent Pipe4"Vent Pipe
C-DW2-TW50T C-DW2-TW75T
60 ft.**
7 ft. 55 ft. 50 ft. 45 ft.
180 ft.
15 ft. 175 ft. 170 ft. 165 ft.
Max. Equivalent Length Min. Equivalent Length Number 1 of 2 90° Elbows 3
Heat Exchanger Values*
Supply Temperature Return Temperature Differential Flow Rate Net Output
140°F 120°F
20°F
2.3 GPM
20,000 BTU/Hr.
120°F 100°F
20°F
3.4 GPM
29,000 BTU/Hr.
100°F
80°F 20°F
4.4 GPM
38,000 BTU/Hr.
K
B
Heat Exchanger
Head Loss
GPM
2 5
8 10 12
Ft. of
Hd. Loss
0.15
0.94
2.40
3.75
5.40
Printed in U.S.A.
547-B-0715-A
©2015, Bradford White Corporation. All rights reserved.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931 ●Fax 215-641-1670 / Technical Support 800-334-3393 ●Fax 269-795-1089 ●Warranty 800-531-2111 ●Fax 269-795-1089
International: Telephone 215-641-9400
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100 ●Fax 905-238-0105 / www.bradfordwhite.com
*These values were obtained using 180°F stored tank temperature.
Net Output is the space heating capacity based on normal piping and pickup allowance of 15%.
Actual values may vary based on circulator flow rate, number of zones, water and space heating demands. Numbers subject to change.