Bradford White C-DW2-504T10FBN, C-DW2-75T10BN User Manual

Residential Atmospheric Vent Combi2
Photo is of
FEATURING:
Gas Water Heater System
The Combi2® FVIR Defender Safety System® Model Features (C-DW2-504T10FBN
model only):
Advanced ScreenLok
designed to prevent ignition of flammable vapor outside of the water heater.
Resettable Thermal Switch—Proven and reliable bimetallic switch prevents burner
and pilot operation in case of ongoing flammable vapors burning inside of the combustion chamber or restricted air flow.
Maintenance Free—Regular cleaning of air inlet openings or flame arrestor is not
required under normal conditions.
Sight Window—Offers a view into the combustion chamber to observe the operation
of the pilot and burner.
All Combi2® Models Feature:
Bradford White ICON System
technology and built-in piezo igniter. A standard, off-the-shelf thermopile converts heat energy from the pilot flame into electrical energy to operate the gas valve and microprocessor. No need for external electricity.
-- Enhanced Performance—Proprietary algorithms provide enhanced First Hour Rating and tighter temperature differential.
-- Advanced Temperature Control System—Microprocessor controls burner operation for consistent and accurate water temperature levels up to 180°F (82°C).
-- Intelligent Diagnostics—Exclusive multicolor LED light indicates operation status/ service required.
Internal Double Wall Heat Exchanger—Double wall 1
(Vitraglas
®
) steel coil ensures separation of potable water and heating fluid.
-- 3/4" (19mm) NPT Front Supply and Return Connections.
-- Low Heat Exchanger Head Loss—Up to 8 GPM (30 LPM) flow, with less than 6 ft.
(1.8m) of head loss. Greatly reduces the required pump size for heat exchange.
Factory Installed Hydrojet
that also increases first hour rating of hot water while minimizing temperature build-up in tank.
Vitraglas
®
Lining—An exclusively engineered enamel formula that provides superior
tank protection from the highly corrosive effects of hot water. This formula (Vitraglas fused to the steel surface by firing at a temperature of over 1600°F (871°C).
Insulation System—2" (51mm) Non-CFC foam insulation covers the sides and top
of the tank, reducing heat loss. This results in less energy consumption, improved efficiencies, and jacket rigidity.
Pedestal Base.
Water Connections—3⁄4" (19mm) NPT factory installed true dielectric fittings.
Two Protective Anode Rods.
T&P Relief Valve—Installed.
Low Restrictive Brass Drain Valve—Durable tamper proof design.
Thermostatic Mixing Valve (ASSE Approved)—Included.
®
Technology Flame Arrestor Design—Flame arrestor is
®
Intelligent gas control with proven millivolt powered
1
2" (38mm) O.D. glass coated
®
Total Performance System—ediment reducing device
®
®
) is
10-Year Limited Tank and Heat Exchanger Warranties / 6-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Combi2
®
, Defender Safety System®, Vitraglas®, Hydrojet® and ScreenLok® are registered trademarks of Bradford White® Corporation.
545-B-0119
Residential Atmospheric Vent Combi2® Gas Water Heater System
K
B
PLUG TYPE ANODE
Combi2® Models
NATURAL GAS AND LIQUID PROPANE GAS
Model
Number
C-DW2-504T10FBN C-DW2-75T10BN
Model
Number
C-DW2-504T10FBN C-DW2-75T10BN
Capacity
U.S. Gal.
45 72
Capacity
Liters
170 272
Nat.
BTU/Hr.
Imp.
Input
Gal.
386165,000
76,000
Nat.
kW
Input
19.1
22.3
LP
BTU/Hr.
Input
61,000 76,000
LP kW
Input
17.9
22.3
Nat. U.S.
GPH
70 81
Liters/
Recovery
90°F Rise*
Nat. Imp.
GPH
59 70
Recovery
50°C Rise*
Nat.
Hour
265 317
LP
U.S. GPH
66 81
LP
Liters/
Hour
250 317
LP
Imp. GPH
55 70
A
Floor to
Flue
Conn.
in.
1
59 621/4
A
Floor to
Flue
Conn.
mm.
1505 1581
C
B
Vent
Jacket
Size
Dia.
in.
in.
22 26
B
Dia.
mm.
559 660
Vent Size
mm.
102 102
4 4
C
/4
Jacket
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed 80% Recovery Efficiency
F
E
D
Floor to
T&P
Conn.
in.
50
3
51
D
Floor to
T&P
Conn.
mm.
1270 1314
Floor
Floor
Conn.
/4
Floor
Conn.
mm.
Gas
in.
13
13
Gas
330 352
to
7
E
to
Exchanger
/8
Exchanger
to
Inlet
in.
27 295/8
F
Floor
to
Inlet mm.
780 752
7
/8
G
Floor
to
Exchanger
Outlet
in.
50
3
/4
51
G
Floor
to
Exchanger
Outlet
mm.
1270 1314
H
Floor
to
Top of
Heater
in.
563/8
59
H
Floor
to
Top of
Heater
mm.
1432 1499
Propane model features a Titanium Stainless Steel propane burner. For Propane (LP) models change “BN” to “SX”. * Based on manufacturers rated recovery efficiency.
PLUG TYPE ANODE
C
K
B
Heat Exchanger Values*
Supply Temperature
A
D & G
J
H
Return Temperature Differential Flow Rate Net Output
140°F 120°F
20°F
2.3 GPM
20,000 BTU/Hr.
3.4 GPM
29,000 BTU/Hr.
* These values were obtained using 180°F stored tank
F
E
temperature. Net Output is the space heating capacity based on
normal piping and pickup allowance of 15%. Actual values may vary based on circulator flow rate,
number of zones, water and space heating demands. Numbers subject to change.
120°F 100°F
20°F
Floor
Water Conn.
in.
60
Floor
Water Conn.
mm.
1534 1600
J
K
Depth
to
in.
3
/8
241/2
63
303/8
J
K
Depth
to
mm.
622 772
Heat Exchanger
Head Loss
GPM
2 5
8 10 12
4.4 GPM
38,000 BTU/Hr.
Ft. of
Hd. Loss
0.15
0.94
2.40
3.75
5.40
100°F
80°F 20°F
Approx.
Shipping
Weight
lbs.
238 302
Approx.
Shipping
Weight
kg.
108 136
General Meets NAECA Requirements.
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All potable water and heat exchanger connections are 3⁄4" NPT (19mm) on 11" (203mm) centers. All gas connections 1⁄2" (13mm). All models design certified by CSA International (formerly AGA/CGA), ANSI Z21.10.1 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into the potable water side. The potable side of this unit may NEVER be connected to any existing heating system or component(s) previously used with a non­potable water heating appliance. The heat exchanger side of the unit may be used in space heating applications.
For field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931 n Fax 215-641-1612
n
n
Email techserv@bradfordwhite.com
Email warranty@bradfordwhite.com
Printed in U.S.A.545-B-0119
Ambler, PA
Technical Support 800-334-3393 Warranty 800-531-2111 International: Telephone 1-215-641-9400 n Email international@bradfordwhite.com / www.bradfordwhite.com
©2019, Bradford White Corporation. All rights reserved.
Loading...