Bradford-White 105-B User Manual

STANDARD
9001
1
EFFICIENCY R
ATING
CERTIFIED
Residential Energy Saver
High Input Direct Vent Water Heater
Features:
Bradford White is ISO registered to the 9001 standard.
All residential storage models meet or exceed efficiency requirements of the Department of Energy. ASHRAE Standard 90.1 b (current standard) and the National Appliance Energy Conservation Act of 1987 recent amendment effective January 20, 2004 which supercedes all state and local efficiency requirements.
Closed combustion—all air for combustion is taken directly from the outside. The co-axial vent pipe (pipe inside a pipe) draws combustion air in through the outer pipe (6"), and exhausts the products of combustion through the inner pipe (4").
Co-axial—rotational venting at top of unit.
Heat Traps—factory installed, minimizes heat loss through piping.
Water Connections—3/4" NPT factory installed true dielectric fittings.
Extends water heater life and eases installation.
No electrical power necessary.
Piezo igniter—for ease of lighting the pilot.
Vitraglas®lined tank—Bradford White water heater tanks are
protected from the corrosive effects of hot water by an exclusive ceramic porcelain-like coating. The Bradford White high silica Vitraglas lining provides a tough interior surface for our water heater tanks.
Factory installed Hydrojet®Total Performance System—cold inlet sediment reducing device. Helps prevent sediment build up in tank. Increases first hour delivery of hot water while minimizing temperature build up at top of tank.
Protective magnesium anode rod—provides added protection against corrosion for long trouble-free service.
Brass drain valve.
T&P relief valve—included.
Side Tappings—for space heating purposes.
Fully automatic controls—automatic temperature selection at your
fingertips. Built-in energy cut-off switch prevents abnormally high water temperature for extra safety. Built-in gas pressure regulation. Fast­acting thermostat starts heat recovery cycle sooner.
Optional vent kits—allow for up to 8 foot max vertical and 8 foot max horizontal (2.4 meters). All DH-1 models must be terminated horizontally
Six or ten year limited warranty on steel tank—heavy gauge steel automatically formed, rolled and welded to assure a continuous seam for glass lining.
Six year limited warranty on parts.
Design certified by CSA International. (formerly AGA and CGA)
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 7,063,133 B2; 5,954,492; 5,954,492; 5,761,379; 5,943,984; 5,081,696; 5,988,117; 6,142,216; 5,199,385; 5,574,822; 5,372,185; 5,485,879; 5,277,171; (B1)5,341,770; 5,660,165; 5,596,952; 5,682,666; 4,904,428; 5,023,031; 5,000,893; 4,669,448; 4,829,983; 4,808,356; 5,115,767; 5,092,519; 5,052,346; 4,416,222; 4,628,184; 4,861,968; 4,672,919; Re. 34,534. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105.5.
®
Sales/800-523-2931
Fax/215-641-1670
Technical Support/ 800-334-3393
Fax/269-795-1089
Warranty/800-531-2111
Fax/269-795-1089
International:
Telephone/215-641-9400
Telefax/215-641-9750
Ambler, PA
888-538-7833
Fax on Demand:
bradfordwhite.comwww.
For U.S. and Canada field service,
contact your professional installer or
local Bradford White sales representative.
Sales/Technical Support
866-690-0961 905-238-0100
Fax/905-238-0105
Mississauga, ON
www.bradfordwhitecanada.com
C
E & F
D
1
/2” GAS
CONNECTION
SIDE WATER OUTLET
DRAIN VALV E
SIDE WATER INLET
G
A
B
6.5 inch (16.5 cm) Min. Diameter Hole in Wall
Y
1
1 9/16
X
11 1/2
7 3/16”
Boot Extension
H
Horizontal "X"
16 1/4 18 25 1/4 37 3/4 61 5/16
17 3/16 20 11/16 35 3/16 57 7/8 107 5/16
order order
no add'l order
order
11 9/16
kit F kit G
kit req'd kit H
kit I
16 5/16 *order order
order order
order
17 1/4 kit F (2) kit G & F
kit F kit H & F
kit F & I
18 1/16 order order
order order
order
20 3/4 kit F & G kit G (2)
kit G kit G & H
kit G & I
25 5/16
order order order order order
35 1/4
k
it F kit G kit H kit H (2) kit I
38 1/16
o
rder order order order order
57 15/16
kit H & F kit H & G kit H (2) kit H (3) kit H & I
61 3/8 order order
order order
order
Vertical "Y"
107 3/8 kit I & F kit I & G
kit I kit I & H
kit I (2)
The standard vent kit (239-42979-00) is ordered and shipped separately. The components are as follows: 4" vent tube*, 6" Air Intake Tube, Vent Terminal, Inner Wall
erm Mounting Flange, Outer Wall Term. Mounting Flange, Vent Terminal Hardware,
T RTV Silicone Sealant, 4" Vent Elbow and a 6" Air Intake Elbow. The vent tube and air
ntake tube telescopes from 13 3/4" to 23 11/16".
i
Horizontal Installation Only
ptional Kits
O
art Number Description
P
43-42516-00
2
43-42517-00
2
43-42514-00
2
43-42512-00
2
Energy Saver Direct Vent Models
:
(2) = Order two of the kits referenced.
*
it F – Telescopes from 4
K
it G – Telescopes from 6
K
it H – Telescopes from 13
K
it I – Telescopes from 49
K
1
3
1
to 5
4"
16"
1
3
to 9
2"
16"
3
11
to 23
4"
16"
to 95
16"
13
16"
13
* (3) = Order three of the kits referenced. The bold text above show what kit(s) are needed in addition to the standard vent and air
ntake tubes. If the standard vent and air intake tubes are not used in the venting system
i (those that do not have bold text) they can be discarded or saved.
or vent distances not found in the selection chart above, please contact the Product
F
anagement Department for sizing recommendations.
M
EC listed. 78% Recovery Efficiency for all models.
C
NATURAL GAS
Model Number
DH1-504T6BN DH1-65T6BN DH1-75S6BN
(LP)
(LP)
For 10 year models, change suffix from “6” to “10”. All propane gas heaters are equipped with Cast Iron Burner.
Change suffix “BN” to “CX”.
Suitable for Water (Potable) Heating and Space Heating
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.
General
All gas water heaters are certified at 300 PSI (2068 kPa) test pressure and 150 PSI (1034 kPa) working pressure. All water connections are 3⁄4" (19mm) NPT on 11" (703mm) centers on top of unit, all gas connections 1⁄2" (13mm). All models design certified by CSA International (formerly AGA and CGA). Recovery based on rated efficiency.
Meets NAECA requirements. All natural gas models meet SCAQMD requirements. Dimensions and specifications subject to change without notice
in accordance with our policy of continuous product improvement.
6-Year Limited Warranty on Component Parts
BRADFORD WHITE CORPORATION has a 6-year warranty on replaceable parts– thermostat, burner, dip tube, drain valve and piezo igniter. These quality components are manufactured for us by industry leaders and will be replaced in the event of failure during the parts warranty period (exclusive of shipping and re-installation cost).§
§ Some states do not allow limitations on warranties. See complete copy of the
Vitraglas®and Hydrojet®are registered trademarks of Bradford White®Corporation. ©2006, Bradford White Corporation. All rights reserved.
105-B-HIDV-1106-A Printed in U.S.A.
warranty included with this product. Indicated warranties apply to USA, Canada and Puerto Rico installations.
U.S.
Imp.
Gal.
Gal.
Cap.
Cap.
48
40
65
54
75
62
Input
Liters
BTU
182
50,000
246
55,000
284
60,000
GPH Rec.
KW
14.7
16.1
17.6
50˚C/90˚F Rise
Imp.
Gal.USGPH
43
53
47
58
51
63
LPH
201 220 238
Ht. to
Center Line
of Vent
in. mm.
751⁄4
1911
781⁄4
1988
751⁄2
1918
6 or 10-Year Limited Tank Warranties
BRADFORD WHITE CORPORATION LIMITED WARRANTY: Protects your
A
investment in a quality glass-lined heater. If the tank leaks for reasons of faulty materials, workmanship, or corrosion within the warranty period, the heater will be replaced with a compara­ble heater of our manufacture (exclusive of shipping and re-installation cost).§
B
Jacket
Dia.
in. mm.
20
508 559
22
1
622
24
2
C
Ht. to
Top of
Heater
in. mm.
3
58
1492
4
1557
62
1499
59
D
Ht.to
Gas
Conn.
in. mm.
151⁄4 151⁄4 151⁄4
E
Ht. to
T&P
Conn.
in. mm.
1
1327
4
52
387 387 387
LP)
(
1422
56
1321
52
Propane Gas Inputs
DH1-504T6CX 48,000 BTU/H 14.1 KW 41 50 189
F
Space
Htg.
Outlet
in. mm.
1327
521⁄4
56
1422
52
1321
G
400 400 419
Vent Dia.
in. mm.
102/152
4/6
102/152
4/6
102/152
4/6
Space
Htg. Inlet
in. mm.
153⁄4 153⁄4 161⁄2
Recovery at
50°C Rise and 90°F Rise
Imp. U.S. Liters/ GPH GPH Hr.
DH1-75S6CX 57,000 BTU/H 16.7 KW 48 60 227
Approx.
Shpg.
Wt.
Lbs. Kg.
197/89.4
243/110 281/127
Loading...