BQT BT900-WG, bqt miP9, CSN9, BT900-D, BT900 BT900-BM Installation Manual

Drilling template
20mm (0.79”) diameter hole for wire entry
2 x 4 mm (0.16”) diameter ho les for mounting screws
Inner reader di mension is 88mm x 88 mm (3.47 " x 3.47")
Assemble reader outer dimension is 90mm x 90mm (3.54” x 3.5 4”)
Reader corne r radius is 4mm (0.16”)
Output protocols
Wiegand 26-199 bit, RS485 or custom confi guration (Model dependent)
BT815-WG/ MiP5/CSN5
BT815-D/D2
BT815
BT815-BM
Power requirement
12V DC
6-18V DC
7-16V DC
Current consumption
103mA (Avg)
145mA (Peak)
157mA (Avg)
174mA (Peak)
38mA (Avg)
80mA (Peak)
45mA (Avg)
135mA (Peak)
Read range
20-40mm (0.8”-1.6”) at 12V DC de pends on the type of card used
Operating temperature
-25’C to +65’C (-13’F to 149’F)
Relative humidity
90% max, operating non-c ondensing
Reader dimensions
Standard: 90mm(L) x 90mm(W) x 27mm(D) (3.54”x3.54”x1.06”) Slim Line: 90mm(L) x 90mm(W) x 20mm(D) (3. 54”x3.54”x0.79”)
Status LED
Green & Red
Audible tone
Internal and external buzzer control
Colour finish
Charcoal & Ivory
IP rating
IP65
Information o btained in this docume nt is subject to change w ithout notice.
For further technical inf ormation, visit our webs ite at www.bqtsolutions.com or email
techsupport@ bqtsolutions.com.
Alternatively contact us at one of our global locations
AUSTRALIA & PACIFIC
BQT Solutions (Australia) Pty Limited Level 1, 82 Waterloo Road Macquarie Park, NSW 2113, Australia Phone: +61 (0)2 8817 2800 Fax: +61 (0)2 8817 2811 Email: sales@bqtsolutions.com
EUROPE AND MIDD LE EAST
BQT Solutions (UK) Limited Regal House, 70 London Road Twickenham, TW1 3QS United Kingdom Phone: +44 (0)20 8622 4428 Fax: +44 (0)20 8622 4401 Email: salesuk@bqtsolutions.com
GREATER ASIA
BQT Solutions Singapore Office Mediapolis 71 Ayer Rajah Crescent #03-03 Singapore 139951 Phone: +65 6220 7970 Fax: +65 6220 7656 Email: salesasia@bqtsolutions.com
Copyright © 2012 BQT S olutions Limi ted. BQT Solutio ns and the BQ T solutions l ogo are register ed trademarks of BQT Solutions (Australia) Pty Ltd.
Wiring diagram
Note:
A shielded cable is recommended to be used. The shield is connected to controller 0V reference
Maximum wieg and data cable length: 150 meters (500 feet)
Buzzer and LED are activated when buzzer and LED line go below 2.5V.
RS485 lines and Relay lines are only for optional use.
Some models have additional wires/connectors which are not specified in the diagram above. These wires are for other
requirements. DO NOT connect them unless specified from BQT Solutions or a BQT authorized distributor. Any damage caused by incorrect connection will void the warranty
Terminate or insulate all un-used wires
Regulatory Information
C-Tick: This device is C-Tick complied. CE: The device has passed all relevant tests and obtained CE approval. FCC: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device
may not cause harmful interference and 2) this device must accept any interference received, including interference that may cause undesired operation of the device. Warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and use d in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressively approved by BQT Solutions could void the user’s authority to operate this equipment.
5
Series
INSTALLATION GUIDE
Version4.1
Installation
Remove the cover by holding the unit by the rim and pushing the reader out with your thumbs.
Note: DO NOT use a screw driver or other implement to remove cover
If necessary, drill holes in the wall for the mounting screws or mounting box on which the reader unit will be placed. (Use the Drilling Template provided overleaf).
1. Place the controller and power supply cable through the grommet hole.
2. Drill the holes as indicated in the template.
Note: Make sure that you don't drill through the cable.
Wire connection Note:
Power to the unit is provided from the listed control unit or from a separately UL listed 12V DC power-limited, access control power source. DO NOT supply power during installation.
Wiring methods shall be in accordance with the Electrical wiring regulation in your country / region.
Check your circuit diagram for the colour coding of the circuit wiring. The reader can be damaged beyond repair if the wiring is connected incorrectly. This will void the warranty.
1. Connect the 0V wire to the power 0V line;
Note: The 0V line of all power supplies must be connected to a common 0V reference
point.
2. Connect the Wiegand data wires;
3. Connect the Buzzer and LED wires;
4. Connect 12V DC wire;
5. Place reader on the wall (Make sure the wires are not crushed. This
will void the warranty if damage occurs)
6. Insert and hand tighten the screws;
7. Check that the reader is level before tightening the screws;
Note: Excessive tightening of screws may deform the casing, resulting in a damaged
unit. This will void the warranty.
8. Turn on the 12V DC power to power up reader.
9. Allow 5 – 10 seconds for reader to finish initialization (depends on the
application). Make sure reader is functioning correctly according to the application specification.
External Use
Make sure the wire bundle to the reader has an IP rating of at least IP65
Handling
Handle the reader with care. DO NOT damage or drop unit before
installation. This will void the warranty.
If the case is damaged, the reader may not be to the specified IP rating.
Replace the reader if the case is damaged.
Maintenance
Once installed the reader requires no maintenance.
Troubleshooting
Problem
Troubleshoo ting steps
Power on rea der – reader does
not start up
1. Check connections
2. Check the voltage a t the reader
3. Check the current capability of the power
supply
Power on rea der – reader keeps
beeping
1. Check buzzer line
2. Check the voltage a t the reader
3. Check the current capability of the power
supply
Power on rea der – LED stays green
1. Check LED line
Present a card to reader – a beep
is heard but reade r does not output any data
1. Check whether the card has data encoded
2. Check the wiegand connection to controlle r
3. Check the voltage level on wiegand data li nes
Present a card to reader – no
response from reader
1. Try a known working card
2. Check if the reader requires to be configured
with a confi guration car d
If the proble m still pers ists, please contact your distributor for technical support.
Warranty
Unless specified otherwise, the Company warrants to the Customer that’ BQT Solutions Branded Products’ (excluding third party products and software) are covered by a return to base warranty on defects in materials and workmanship affecting normal use for a period of the Warranty offered under the Standard Terms and Conditions of Sale from BQT invoice date (‘Standard Warranty’)
This standard warranty does not cover damage, fault, failure or malfunction due to external causes including; accident, misuse, problems with electrical power, servicing not authorised by the Company, usage and/or storage and/or installation not in accordance with Product instructions, failure to perform required preventative maintenance, normal wear and tear, act of God, fire, flood, war, any violent or similar occurrence; any attempt by any person other than Company personnel or any person authorised by the Company to repair or support the Products and problems caused by use of parts and components not supplied by the Company. The standard warranty does not cover any items that are in one or more of the following categories: software; external devices; accessories or parts added to the product after the product has been shipped from BQT Solutions.
During the warranty, period beginning on the invoice date, the Company will repair or replace faulty products (at its absolute discretion) returned to its’ factory. The Customer must prepay shipping and transportation costs and insure the shipment or accept the risk of loss or damage during such transportation.
The Customer shall be solely responsible for determining suitability for use and the Company will, in no event, be liable in this respect. This standard warranty is given in place of all warranties, conditions, terms, undertakings and obligations implied by statute, common law, trade usage, and course of dealing or otherwise including warranties or conditions of merchantability, fitness for purpose, satisfactory quality and / or compliance with description, all of which are hereby excluded to the fullest extent permitted by law.
Drilling template
20mm (0.79”) diameter hole for wire entry
2 x 4 mm (0.16”) diameter ho les for mounting screws
Minimum reade r dimensions are 140mm x 45 mm (5.51" x 1.77")
Output protocols
Wiegand 26-199 bit, RS485 or custom confi guration (Model dependent)
BT900-WG/ miP9 / CSN9
BT900-D
BT900
BT900-BM
Power requirement
12V DC
6-18V DC
7-16V DC
Current consumption
103mA (Avg)
145mA (Peak)
135mA (Avg)
155mA (Peak)
38mA (Avg)
80mA (Peak)
45mA (Avg)
135mA (Peak)
Read range
20-40mm (0.8”-1.6”) at 12V DC de pends on the type of card used
Operating temperature
-25’C to +65’C (-13’F to 149’F)
Relative humidity
90% max, operating non-c ondensing
Reader dimensions
140mm(L) x 45mm(W) x 32mm(D) (5.51”x1.77”x1.26”)
Status LED
Green & Red
Audible tone
Internal and external buzzer control
Colour finish
Two toned – Silver & Charcoal
IP rating
IP65
Information o btained in this docume nt is subject to change w ithout not ice.
For further technical inf ormation, visit our webs ite at www.bqtsolutions.com or email
techsupport@ bqtsolutions.com
.
Alternatively contact us at one of our global locations
AUSTRALIA & PACIFIC
BQT Solutions (Australia) Pty Limited Level 1, 82 Waterloo Road Macquarie Park, NSW 2113, Australia Phone: +61 (0)2 8817 2800 Fax: +61 (0)2 8817 2811 Email: sales@bqtsolutions.com
EUROPE AND MIDD LE EAST
BQT Solutions (UK) Limited Regal House, 70 London Road Twickenham, TW1 3QS United Kingdom Phone: +44 (0)20 8622 4428 Fax: +44 (0)20 8622 4401 Email: salesuk@bqtsolutions.com
GREATER ASIA
BQT Solutions Singapore Office Mediapolis 71 Ayer Rajah Crescent #03-03 Singapore 139951 Phone: +65 6220 7970 Fax: +65 6220 7656 Email: salesasia@bqtsolutions.com
Copyright © 2012 BQT S olutions Limi ted. BQT Solutio ns and the BQ T solutions l ogo are register ed trademarks of BQT Solutions (Australia) Pty Ltd.
Wiring diagram
Note:
A shielded cable is recommended to be used. The shield is connected to controller 0V reference
Maximum wie gand data cable length: 150 meters (500 feet)
Buzzer and LED are activated when buzzer and LED line go below 2.5V.
• RS485 lines and Relay lines are only for optional use
Some models have additional wires/connectors which are not specified in the diagram above. These wires are for other
requirements. DO NOT connect them unless specified from BQT Solutions or a BQT authorized distributor. Any damage caused by incorrect connection will void the warranty
Terminate or insulate all un-used wires
Regulatory Information
C-Tick: This device is C-Tick complied. CE: The device has passed all relevant tests and obtained CE approval. FCC: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device
may not cause harmful interference and 2) this device must accept any interference received, including interference that may cause undesired operation of the device. Warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressively approved by BQT Solutions could void the user’s authority to operate this equipment.
9
Series
INSTALLATION GUIDE
Version4.1
Installation
Remove the cover by holding the unit as shown and pulling the cover from the top as illustrated
Note: DO NOT use a screw driver or other implement to remove cover
If necessary, drill holes in the wall for the mounting screws or mounting box on which the reader unit will be placed. (Use the Drilling Template provided overleaf).
1. Place the controller and power supply cable through the grommet hole.
2. Drill the holes as indicated by the arrows.
Note: Make sure that you don't drill through the cable.
Wire connection Note:
Power to the unit is provided from the listed control unit or from a separately UL listed 12V DC power-limited, access control power source. DO NOT supply power during installation.
Wiring methods shall be in accordance with the Electrical wiring regulation in your country / region.
Check your circuit diagram for the colour coding of the circuit wiring. The reader can be damaged beyond repair if the wiring is connected incorrectly. This will void the warranty.
1. Connect the 0V wire to the power 0V line;
Note: The 0V line of all power supplies must be connected to a common 0V reference
point.
2. Connect the Wiegand data wires;
3. Connect the Buzzer and LED wires;
4. Connect 12V DC wire;
5. Place reader on the wall (Make sure the wires are not crushed. This
will void the warranty if damage occurs)
6. Insert and hand tighten the screws;
7. Check that the reader is level before tightening the screws;
Note: Excessive tightening of screws may deform the casing, resulting in a damaged
unit. This will void the warranty.
8. Turn on the 12V DC power to power up reader.
9. Allow 5 – 10 seconds for reader to finish initialization (depends on the
application). Make sure reader is functioning correctly according to the application specification.
External Use
• Make sure the wire bundle to the reader has an IP rating of at least IP65
Handling
Handle the reader with care. DO NOT damage or drop unit before
installation. This will void the warranty.
If the case is damaged, the reader may not be to the specified IP rating.
Replace the reader if the case is damaged.
Maintenance
• Once installed the reader requires no maintenance.
Troubleshooting
Problem
Troubleshoo ting steps
Power on rea der – reader does
not start up
1. Check connections
2. Check the voltage a t the reader
3. Check the current capability of the power
supply
Power on rea der – reader keeps
beeping
1. Check buzzer line
2. Check the voltage a t the reader
3. Check the current capability of the power
supply
Power on rea der – LED stays green
1. Check LED line
Present a card to reader – a beep
is heard but reade r does not output any data
1. Check whether the card has data encoded
2. Check the wiegand connection to controlle r
3. Check the voltage level on wiegand data lines
Present a card to reader – no
response from reader
1. Try a known working card
2. Check if the reader requires to be configured
with a confi guration car d
If the proble m still pers ists, please contact your distributor for technical support.
Warranty
Unless specified otherwise, the Company warrants to the Customer that’ BQT Solutions Branded Products’ (excluding third party products and software) are covered by a return to base warranty on defects in materials and workmanship affecting normal use for a period of the Warranty offered under the Standard Terms and Conditions of Sale from BQT invoice date (‘Standard Warranty’)
This standard warranty does not cover damage, fault, failure or malfunction due to external causes including; accident, misuse, problems with electrical power, servicing not authorised by the Company, usage and/or storage and/or installation not in accordance with Product instructions, failure to perform required preventative maintenance, normal wear and tear, act of God, fire, flood, war, any violent or similar occurrence; any attempt by any person other than Company personnel or any person authorised by the Company to repair or support the Products and problems caused by use of parts and components not supplied by the Company. The standard warranty does not cover any items that are in one or more of the following categories: software; external devices; accessories or parts added to the product after the product has been shipped from BQT Solutions.
During the warranty, period beginning on the invoice date, the Company will repair or replace faulty products (at its absolute discretion) returned to its’ factory. The Customer must prepay shipping and transportation costs and insure the shipment or accept the risk of loss or damage during such transportation.
The Customer shall be solely responsible for determining suitability for use and the Company will, in no event, be liable in this respect. This standard warranty is given in place of all warranties, conditions, terms, undertakings and obligations implied by statute, common law, trade usage, and course of dealing or otherwise including warranties or conditions of merchantability, fitness for purpose, satisfactory quality and / or compliance with description, all of which are hereby excluded to the fullest extent permitted by law.
Loading...