BOURNS 7032 Service Manual

Features
Six 7032 Models designed to accept all
Bourns station protectors
Accepts all other manufacturers’
protection of similar design
Optional sealed switching jacks with
U
Listed per UL 497 (File: E53117)
L
®
7032 Series – Network Interface Device
The Model 7032 NID is designed to allow service providers the capacity to terminate and add protected service pairs as needed. The 7032 NID is available in pair counts of 1 through 100. Enclosures are manufactured of high-impact resistant, ultra­violet-desensitized, flame retardant UL Listed plastic (50 and 100 pair models are 18 gauge rust resistant zinc-coated steel, with twenty-five pair available in both plastic and steel). This 7032 is completely subscriber lockable with Telco override and subscriber friendly termination posts for safe and secure operation.
How To Order
7032 - XX - X X X - X XX
Model Number Designator
Number of Lines
06, 12, 25, 50, 100
Station Protector Options
D1 = 455HS-MSP (2377-45-HS) Broadband Voice/Data Services
1
Z
= 455HS-BC (2377-45-BC) Balance-Sensitive DSL Systems E = 155HS-MSP (2378-35-HS) Broadband Voice/Data Services Y = 155HS-BC (2378-35-BC) Balance-Sensitive DSL Systems
B = 125EW (2374-01) Dual Gas Tube (UL, cUL, Telcordia) C = 125EW-R (2375-01) Dual Gas Tube (UL, cUL, RUS) L = 356M (2377-01) Balanced Gas Tube (UL, cUL, RUS) M = J130S (2380-27-01) Solid State Protector (UL, cUL) T = Tii355M O = No Station Protectors (Not available with DSL configurations)
Note 1 = Digi. Guard
Enclosure Size and Construction (see table for dimensions)
A = 6 Pair Capacity (Plastic) B = 12 Pair Capacity (Plastic) C = 25 Pair Capacity (Steel)
E = 100 Pair Capacity (Steel) P = 1/2 inch Plywood-no enclosure V = 25 Pair Capacity (Plastic)
D = 50 Pair Capacity (Steel)
Special Options
S = Sealed Switching Jack w/IDC (85122-T-IDC)
I = Expansion Bridge w/IDC (85122-IDC)
F = Sealed Switching Jack 4-Post (85122-T4) X = Dual Ground Plate J = Modular Jacks (85122) O = No options
B = Expansion Bridge w/Binding Posts (85122-B)
DSL Options
A = One 3610A, ADSL POTS Splitter P = One 3610A2, ADSL 2+ POTS Splitter V = One 3630A, VDSL POTS Splitter
Number of DSL Lines
03, 06, 12, 25, 50
To add lines, use station protector + upgrade kit 85003 (old style) or:
85122 Standard Jack (Not available with DSL configurations) 85122-T4 Sealed Switching Jack, 4-post 85122-T-IDC Sealed Switching Jack w/IDC
*DSL Configuration Note: 3610A or 3630A must be ordered with option D, Z, E or Y Station Protectors.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
REV. G 05/06
7032 Series – Network Interface Device
Product Dimensions
Enclosure Pair DSL
Dimensions
Size (Max.) (Max.) High Wide Deep
A0603
B1206
C2512
D5025
E 100 50
V2512
RJ11 Subscriber Bridges
279.4 279.4 101.6 (11.0) (11.0) (4.0)
444.5 279.4 127 (17.5) (11.0) (5.0)
431.8 406.4 76.2 (17.0) (16.0) (3.0)
914.4 482.6 114.3 (36.0) (19.0) (4.5)
914.4 508 177.8 (36.0) (20.0) (7.0)
469.9 444.5 139.7 (18.5) (17.5) (5.5)
Expansion Bridges
85122-IDC
85122
Standard Loop
85122-T4*
Internal Switch - 4 Lugs
Insulation Displacement
Connectors
T R
T R
12
T R T R
34
DIMENSIONS:
Binding Post
MM
(INCHES)
85122-B
85122-T-IDC*
Sealed Switch Jack w/IDC
*Includes environmental sealant and closed-cell foam gasket.
Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications.