*RoHS Directive 2002/95/EC Jan 27 2003 including Annex
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
2026 Series - 3-Pole Gas Discharge Tube
Features
■ Balanced TRIGARD
®
■ Approximately 8 mm diameter, 11 mm long
■ UL recognized
■ Custom configurations available
■ High surge current rating
■ Stable breakdown throughout life
■ RoHS compliant* version available
Applications
■ Telecommunications
■ Industrial electronics
■ Commercial electronics
■ Consumer electronics
■ Automotive, aircraft, military electronics
Impulse Transverse Delay ......................................1000 V/µs.....................................................................< 75 ns
Insulation Resistance.............................................100 V (50 V for Model 2026–07 & 2026-09).................> 10
10
Ω
Glow Voltage..........................................................10 mA...........................................................................~ 70 V
Arc Voltage.............................................................1A.................................................................................~ 10 V
Glow-Arc Transition Current........................................................................................................................< 0.5 A
Capacitance...........................................................1 MHz...........................................................................< 2 pF
DC Holdover Voltage
2
...........................................>135 V, (52 V for Model 2026-07 & 2026-09,...............< 150 ms
80 V for Model 2026-15)
Impulse Discharge Current ....................................40000 A, 8/20 µs
3
......................................................... 1 operation minimum
20000 A, 8/20 µs..........................................................> 10 operations
1000 A, 10/1000 µs .....................................................> 400 operations
Alternating Discharge Current................................130 Arms, 11 cycles
3
................................................... 1 operation minimum
20 Arms, 1 s.................................................................> 10 operations
Operation and Storage Temperature, Climatic Category (IEC 60068-1) 40/ 90/ 21.................................... -40 to +90 °C
Optional Switch-Grade Fail-short device available.
Notes:
• UL recognized component, UL File E153537.
• Model number marking on tube: 26-xxx V.
• The rated discharge current for TRIGARD
¤
Gas Discharge Tubes is the total current equally divided between each line to ground.
• Sparkover limits after life ±25 %, IR >10
8
Ω (-25 %,+30 % for Model 2026-07, 2026-09 and 2026-60).
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859
1
Tube meets BT requirement Type 14 A/1 (210-310 V).
2
Network applied.
3
DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
Characteristics
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31, RUS PE-80, Telcordia GR 1361