Bosh MIC IP ultra 7100i, MIC IP starlight 7100i User Manual

Page 1
MIC IP ultra 7100i │ MIC IP starlight 7100i
en
User Manual
Page 2
Page 3
MIC IP ultra 7100i │ MIC IP starlight 7100i Table of contents | en 3

Table of contents

1
Introduction 6
System overview 8
General 10
Web Interface 16
Camera 19
Recording 41
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 4
4 en | Table of contents MIC IP ultra 7100i │ MIC IP starlight 7100i
6.3 Recording Profiles 42
6.4 Maximum Retention Time 43
6.5 Recording Scheduler 44
6.6 Recording Status 45
6.7 Recording Statistics 45
6.8 Image Posting 45 7
Alarm 46
7.1 Alarm Connections 46
7.2 Video Content Analysis (VCA) 48
7.3 Audio Alarm 49
7.4 Alarm E-Mail 50
7.5 Alarm Task Editor 51
7.6 Alarm Rules 51 8
Network 53
8.1 Network Services 53
8.2 Network Access 53
8.3 DynDNS 55
8.4 Advanced 56
8.5 Network Management 57
8.5.1 UPnP 57
8.5.2 Quality of Service 57
8.6 Multicast 57
8.7 Accounts 58
8.8 IPv4 Filter 59 9
Service 60
9.1 Maintenance 60
9.2 Licenses 60
9.3 Certificates 61
9.4 Logging 61
9.5 Diagnostics 61
9.6 System Overview 61 10
Operation via the browser 62
10.1 Live page 62
10.1.1 Connection 62
10.1.2 PTZ 62
10.1.3 Pre-positions 62
10.1.4 AUX Control 63
10.1.5 Special Functions 63
10.1.6 Recording status 64
10.1.7 Saving snapshots 64
10.1.8 Recording live video 64
10.1.9 Full-screen display 64
10.1.10 Audio communication 64
10.1.11 Storage, CPU and network status 64
10.1.12 Status icons 65
10.1.13 Date and Time 65
10.1.14 Video Security App 65
10.2 Playback 66
10.2.1 Selecting the recording stream 66
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 5
MIC IP ultra 7100i │ MIC IP starlight 7100i Table of contents | en 5
Using your MIC Camera 68
13
14
15
Troubleshooting 72
Status Codes 75
AUX Commands 80
Support 82
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 6
6 en | Introduction MIC IP ultra 7100i │ MIC IP starlight 7100i

1 Introduction

1.1 Systems requirements

Computer with Intel Skylake processor or better – Intel HD530 graphic card with performance that matches or is better than the resolution
of the camera – Windows7 (or newer) operating system – Network access – Web browser:
Internet Explorer version 11 (or newer)
Mozilla Firefox
Application software, for example, VideoSecurityClient, BoschVideoClient, BVMS, or
Project Assistant app. – DirectX 11 – MPEG-ActiveX 6.34 (or newer) [required to see, in your browser, live images from the
camera] – Configuration Manager 7.0 (or newer)

1.2 Establishing the connection

The unit must have a valid IP address to operate on your network and a compatible subnet mask. By default, DHCP is pre-set at the factory to On and so your DHCP server assigns an IP address. With no DHCP server the default address is 192.168.0.1
1. Start the Web browser.
2. Enter the IP address of the unit as the URL.
3. During initial installation, confirm any security questions that appear.
Note:
If you cannot connect, the unit may have reached its maximum number of connections. Depending on the device and network configuration, each unit can have up to 50 web browser connections, or up to 100 connections via BoschVideoClient or Bosch Video Management System.

1.3 Configuration with Project Assistant app

You can also use the Project Assistant app to complete the initial configuration of the camera. In order to use this device with the Project Assistant app by Bosch, you must download the app from the Bosch Download Store, from Google Play, or from the Apple Store. You can access the app in several ways: – Scan the QR code from the QIG. – From www.boschsecurity.com, select Support > Apps and Tools > Online Apps - Video >
Bosch Project Assistant app. Select the appropriate operating system, and then click the
appropriate button to download and install the app. – From Google Play Store (play.google.com), search for Bosch Project Assistant. Select the
app from the list. Click the Install button. – From Apple Store (itunes.apple.com), search for Bosch Project Assistant. Select the app
from the list. Click the appropriate button to download and install the app.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 7
MIC IP ultra 7100i │ MIC IP starlight 7100i Introduction | en 7

1.4 Password protection in camera

The device is password-protected. The first time that any user accesses the device, the device will prompt the user to set a password at the service level. The camera requires a strong password. Follow the prompts in the dialog box, which specifies what is required. The system measures the strength of the password that you enter. When you use Configuration Manager to access your device for the first time, you must set the initial password of the device in Configuration Manager. The Users section (General > Unit Access > Users) displays the message, "Before you can use this device you have to secure it with an initial password."
Note: After you set the initial password, a "lock" icon appears next to the device name in the Devices list in Configuration Manager.
You can also launch the device webpage directly. In the device webpage, an initial password page appears, displaying input fields and a password strength gauge. Enter the user name (“service”) and a password in the appropriate fields. Refer to the section User Management for more information. After a service-level password is set for the device, the device displays a dialog box that prompts users to enter the user name (“service”) and the service-level password every time that they access the device.
1. Fill in the fields User name and Password.
2. Click OK. If the password is correct, the desired page appears.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 8
8 en | System overview MIC IP ultra 7100i │ MIC IP starlight 7100i

2 System overview

When a connection is established, the Live page is initially displayed. The application bar displays the following icons:
Live Click this icon to view the live video stream.
Playback Click this icon to play back recorded sequences.
This link is only visible if a storage medium has been configured for recording. (With VRM recording, this option is not active.)
Configuration Click this icon to configure the device.
Dashboard Click this icon to see detailed system information.
Links Click this icon to navigate to the Bosch download store.

2.1 Live page

The Live page is used to display the live video stream and control the unit.

2.2 Playback

The Playback page is used for playing back recorded sequences.

2.3 Configuration

The Configuration page is used to configure the unit and the application interface.
Making Changes
Each configuration screen shows the current settings. You can change the settings by entering new values or by selecting a predefined value from a list field. Not every page has a Set button. Changes to pages without a Set button are set immediately. If a page does show a Set button, you must click the Set button for a change to take effect.
Notice!
Save each change with the associated Set button. Clicking the Set button saves the settings only in the current field. Changes in any other fields are ignored.
Click this icon to get context-sensitive help for the page you are browsing.
Some changes only take effect after the unit is rebooted. In this case, the Set button changes to Set and Reboot.
1. Make the desired changes.
2. Click the Set and Reboot button. The camera reboots and the changed settings are
activated.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 9
MIC IP ultra 7100i │ MIC IP starlight 7100i System overview | en 9

2.4 Dashboard

The Dashboard page is used to display detailed information about the device. The Dashboard is only visible in the application bar if the Show 'Dashboard' option is enabled by a service-level user in the Configuration -> Web Interface -> Appearance page.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 10
10 en | General MIC IP ultra 7100i │ MIC IP starlight 7100i

3 General

3.1 Identification

Device name
Enter a unique, unambiguous name for the device (for example, the installation location of the device). This name should be easy to identify in a list of devices in your system. The device name is used for the remote identification of a unit, such as in the event of an alarm. Do not use any special characters, for example &, in the name. Special characters are not supported by the system's internal management.
Device ID
Enter a unique identifier for the device. This ID is additional identification for the device.
Video 1
Enter a name or description for the Video 1 stream (for example, “Visible image”).
Host naming
Enter a host name.
Initiator extension
Add text to an initiator name to make identification easier in large iSCSI systems. This text is added to the initiator name, separated from it by a full stop. (You can see the initiator name in the System Overview page.)

3.2 User Management

The section Allowed authentication modes provides information about the authentication modes set in the camera. A checkmark appears in the checkbox to the left of the mode if the mode is set. If the mode is not set, the phrase, “No certificate installed” appears to the right of the mode name.
Password
This field indicates if a password is set for the camera.
Certificate
A check mark in this check box indicates that at least one certificate is loaded onto the camera. If no certificates are loaded, then “No certificate installed” appears to the right of the text. The Escrypt certificate is a root certificate for Bosch Security Systems that proves that the device meets the following criteria: – It originates from a Bosch factory that is a secure environment. – It has not been tampered with. Escrypt is a Bosch company and Certificate Authority (CA).
Active directory server (ADFS)
A check mark in this check box indicates that the camera uses an active directory server. If the camera does not use ADFS, then “No certificate installed” appears to the right of the text.
Password management
A password prevents unauthorized access to the device. You can use different authorization levels to limit access. Proper password protection is only guaranteed when all higher authorization levels are also protected with a password. Therefore, you must always start from the highest authorization level when assigning passwords. You can define and change a password for each authorization level if you are logged into the “service” user account.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 11
MIC IP ultra 7100i │ MIC IP starlight 7100i General | en 11
The device has three authorization levels: service, user, and live. – service is the highest authorization level. Entering the correct password gives access to
all the functions and allows all configuration settings to be changed.
user is the middle authorization level. At this level you can operate the device, play back
recordings, and also control camera, for example, but you cannot change the configuration.
live is the lowest authorization level. At this level you can only view the live video image
and switch between the different live image displays.
To edit a password To edit a password, click the pencil icon to the right of the column Type for the appropriate User name.
To create a new user
To create a new user, click Add. In the box User, fill in the fields. For Group, select the appropriate authorization level. For Type, select either Password (for a new password) or Certificate (for a certificate that the new user is authorized to use).
Note: Use a maximum of 19 characters. Do no use special characters.
Confirm password
In each case, enter the new password a second time to eliminate typing mistakes.
Notice! A new password is only saved when you click the Set button. You should therefore click the Set button immediately after entering and confirming a password.

3.3 Date/Time

Date format
Select the required date format from the dropdown menu.
Device date/Device time
Notice!
Make sure that recording is stopped before synching to the PC.
If there are multiple devices operating in your system or network, it is important to synchronize their internal clocks. For example, it is only possible to identify and correctly evaluate simultaneous recordings when all units are operating on the same time.
1. Enter the current date. Since the unit time is controlled by the internal clock, there is no need to enter the day of the week - it is added automatically.
2. Enter the current time or click the Sync to PC button to copy your computer's system time to the camera.
Note: It is important that the date/time is correct for recording. An incorrect date/time setting could prevent correct recording.
Device time zone
Select the time zone in which the system is located.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 12
12 en | General MIC IP ultra 7100i │ MIC IP starlight 7100i
Daylight saving time
The internal clock can switch automatically between normal and daylight saving time (DST). The unit already contains the data for DST switch-overs for many years in advance. If the date, time and zone have been set up correctly, a DST table is automatically created. If you decide to create alternative daylight saving time dates by editing the table, note that values occur in linked pairs (DST start and end dates).
First, check the time zone setting. If it is not correct, select the appropriate time zone and click Set.
1. Click Details to edit the DST table.
2. Select the region or the city which is closest to the system's location from the list box below the table.
3. Click Generate to fill the table with the preset values from the unit.
4. Click one of the entries in the table to make changes. The entry is highlighted.
5. Click Delete to remove the entry from the table.
6. Choose other values from the list boxes under the table, to change the selected entry. Changes are immediate.
7. If there are empty lines at the bottom of the table, for example after deletions, add new data by marking the row and selecting values from the list boxes.
8. When finished, click OK to save and activate the table.
Time server address
The camera can receive the time signal from time server using various time server protocols, and then use it to set the internal clock. The unit polls the time signal automatically once every minute. Enter the IP address of a time server here. You can choose to have the DHCP server give a time server date by selecting the Overwrite by
DHCP option.
Time server type
Select the protocol that is supported by the selected time server. – Select Time protocol if the server uses the protocol RFC868. – The SNTP protocol supports a high level of accuracy and is required for special
applications and subsequent function extensions.
Select TLS protocol if the server uses the RFC 5246 protocol. – Select Off to disable the time server. Click Set to apply the changes.

3.4 Display Stamping

Various overlays or “stamps” in the video image provide important supplementary information. These overlays can be enabled individually and are arranged on the image in a clear manner.
Camera name stamping This field sets the position of the camera name overlay. It can be displayed at the Top, at the Bottom or at a position of your choice that you can then specify using the Custom option. Or
it can be set to Off for no overlay information.
1. Select the desired option from the list.
2. If you select the Custom option, additional fields are displayed where you can specify the exact position (Position (XY)).
3. In the Position (XY) fields, enter the values for the desired position.
Optionally, tick the Underlay with full-width black bar box to place a black bar beneath the time stamp.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 13
MIC IP ultra 7100i │ MIC IP starlight 7100i General | en 13
Logo
To place a logo on the image, select and upload an uncompressed .bmp file with a maximum size of 128x128 pixels and 256 colors to the camera. Its position on the image can then be selected.
Logo position Select the position for the logo on the OSD: To the left of the name, To the right of the name, or Logo only. Select Off (the default value) to disable logo positioning.
Time stamping
This field sets the position of the time overlay. It can be displayed at the Top, at the Bottom or at a position of your choice that you can then specify using the Custom option. Or it can be set to Off for no overlay information.
1. Select the desired option from the list.
2. If you select the Custom option, additional fields are displayed where you can specify the exact position (Position (XY)).
3. In the Position (XY) fields, enter the values for the desired position.
Display milliseconds
If necessary, you can also display milliseconds. This information can be useful for recorded video images; however, it does increase the processor's computing time. Select Off if you do not need to display milliseconds.
Live video indicator
Select On to display the Live video indicator, an icon that pulses on the OSD to show that the video stream is live. Select Off to hide the Live video indicator.
Alarm mode stamping
Select On to display a text message overlay in the image in the event of an alarm. It can be displayed at a position of your choice that you can then specify using the Custom option. Or it can be set to Off for no overlay information.
1. Select the desired option from the list.
2. If you select the Custom option, additional fields are displayed where you can specify the exact position (Position (XY)).
3. In the Position (XY) fields, enter the values for the desired position.
Alarm message
Enter the message to be displayed in the image in the event of an alarm. The maximum text length is 31 characters.
Title OSD
OSD titles can be displayed at a position of your choice. Select On to display sector or pre-position title overlays continuously in the image. Select Momentary to display sector or pre-position title overlays for a few seconds.
1. Select the desired option from the list.
2. Specify the exact position (Position (XY)).
3. In the Position (XY) fields, enter the values for the desired position.
Select Off to deactivate the display of overlay information.
Camera OSD
Select On to momentarily display camera response information, such as Digital Zoom, Iris open/close, and Focus near/far overlays in the image. Select Off to display no information.
1. Select the desired option from the list.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 14
14 en | General MIC IP ultra 7100i │ MIC IP starlight 7100i
2. Specify the exact position (Position (XY)).
3. In the Position (XY) fields, enter the values for the desired position.
Title region
Select On to set or to edit the position of the title region on the OSD. The fields Position (XY) and (0...255) appear.
1. In the field Position (XY), specify the exact position. (The default is 10.)
2. In the field (0...255), enter the position range. (The default is 176). Select Off to hide the region from view.
Telemetry region
Select On to set or to edit the position of the telemetry information (azimuth and elevation (pan/tilt position)) and the zoom factor on the OSD. Refer to the section ”
34
“ to set the pan and tilt limits.
PTZ Settings, page
The fields Position (XY) and (0...255) appear.
1. In the field Position (XY), specify the exact position. (The default is 10.)
2. In the field (0...255), enter the position range. (The default is 176). Select Off to hide the region from view.
Feedback region
Select On to set or to edit the position of system feedback messages (including message for camera settings such as focus, iris, and zoom level) on the OSD. Refer to the section “Lens Settings” to configure these settings. The fields Position (XY) and (0...255) appear.
1. In the field Position (XY), specify the exact position. (The default is 10.)
2. In the field (0...255), enter the position range. (The default is 176). Select Off to hide the region from view.
Transparent background
Check this box to make transparent the stamp background on the image.
Text color
Select the color for the alarm message to be displayed in.
Background color
Select the background color for the alarm message to be displayed in. If you have enabled the Transparent background option, the background color is not displayed in the OSD.
Stamping size Select the desired font size of the overlays on the OSD: Normal or Large.
Video authentication
Select from the Video authentication drop-down box a method for verifying the integrity of the video. If you select Watermarking, all images are marked with an icon. The icon indicates if the sequence (live or saved) has been manipulated. If you want to add a digital signature to the transmitted video images to ensure their integrity, select one of the cryptographic algorithms for this signature.
Signature interval [s]
For certain Video authentication modes, enter the interval (in seconds) between insertions of the digital signature.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 15
MIC IP ultra 7100i │ MIC IP starlight 7100i General | en 15

3.5 GB/T 28181

This page allows you to set the parameters for conformance to the GB/T28181 national standard “Security and protection video monitoring network system for information transport, switch and control”. This standard is specifically for China.
Enable
Select this checkbox to enable the system to use the other parameters on this page in accordance with the GB/T 28181 national standard.
H.264 elementary stream
Select this checkbox to select or to enable the H.264 elementary stream.
Registration timeout
Enter a value (in milliseconds) for the registration timeout. The default is 3600.
Heartbeat timeout
Enter the value (in seconds) for the heartbeat timeout. The default is 15.
Server ID
Enter the ID of the server.
Server IP address
Enter the server IP address.
Server port
Enter the number of the server port. The default is 0.
Device ID
Enter the ID of the device.
Device port
Enter the number of the device port. The default is 5060.
Password
Enter the appropriate password.
Alarm device ID
Enter the ID of the alarm device.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 16
16 en | Web Interface MIC IP ultra 7100i │ MIC IP starlight 7100i

4 Web Interface

4.1 Appearance

You can adapt the appearance of the web interface and change the website language to meet your requirements. GIF or JPEG images can be used to replace the company and device logos. The image can be stored on a web server (for example, http://www.myhostname.com/images/logo.gif). Ensure that a connection to the web server is always available to display the image. The image files are not stored on the unit. To restore the original graphics, delete the entries in the Company logo and Device logo fields.
Website language
Select the language for the user interface. The default language is English. After selecting a different language, click the Set button. The page refreshes automatically. The GUI now displays field names and options as well as OSD messages in the selected language.
Company logo
To replace the company's logo in the top-right part of the window, enter the path to a suitable image in this field. The image file must be stored on a web server.
Device logo
To replace the device name in the top-left part of the window, enter the path to a suitable image in this field. The image file must be stored on a web server.
Notice! If you want to use the original image again, delete the entries in the fields Company logo and Device logo.
Show VCA metadata
When video content analysis (VCA) is activated, additional information is displayed in the live video stream. With the MOTION+ analysis type, for example, the sensor fields in which motion is recorded are marked with yellow rectangles. Using EssentialVideoAnalytics or IntelligentVideoAnalytics, the outlines of detected objects are displayed in following colors: – Red: Objects that generate an alarm event under the current settings appear on the
camera image inside a red outline.
Orange: An object that has triggered one alarm event but does not generate another
appears inside an orange outline (example: object has crossed a line). During forensic search, an object that triggers an alarm event has an orange outline from the beginning.
Yellow: Objects that are detected as moving but do not generate an alarm event under
the current settings appear inside a yellow outline.
Show VCA trajectories
The trajectories (motion lines of objects) from the video content analysis are displayed in the live video image if a corresponding analysis type is activated. The trajectory is shown as a green line following the object base point.
Show overlay icons
Select this check box to show overlay icons on the live video image.
Show VCA items
Shows alarm fields, lines and routes configured for the video analytics in the following colors:
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 17
MIC IP ultra 7100i │ MIC IP starlight 7100i Web Interface | en 17
Green: Fields, lines and routes used in a task are displayed in green. They can be edited
but not deleted.
Red: Fields, lines and routes currently in alarm mode are displayed in red.
Show 'Dashboard' Select this checkbox to enable the Dashboard in the application bar.
Secure cookies
Select this checkbox to secure the cookies sent through the camera.
Notice!
If cookies are secured, authentication forwarding to MPEG ActiveX and the Video Security App is prohibited.
Latency mode
Select the required latency mode: – Low delay: Default mode. Provides marginal buffering to display fluent video under
normal network conditions.
Smooth video: Allows the buffer to automatically adjust to cover network jitter, inducing
higher latency.
No buffering: Shows video as it is received by the decoder with minimum latency. Allows
the video to jerk if there is network jitter.
Video buffer The value shown is calculated from the Latency mode setting. It cannot be changed.
JPEG resolution You can specify the size of the JPEG image on the Live page. Options are Small, Medium, Large, 720p, 1080p, and “Best possible” (default).
JPEG interval
You can specify the interval at which the individual images should be generated for the M­JPEG image on the Live page.
JPEG quality You can specify the quality at which the JPEG images appear on the Live page.

4.2 LIVE Functions

On this page you can adapt the functions on the LIVE page to your requirements. You can choose from a variety of different options for displaying information and controls.
1. Check the box for the items that are to be made available on the LIVE page. The selected items are indicated by a check mark.
2. Check whether the required functions are available on the LIVE page.
Transmit audio
You can only select this option if audio transmission is actually switched on (see Audio).The audio signals are sent in a separate data stream parallel to the video data, and so increase the network load. The audio data are encoded according to G.711 and require an additional bandwidth of approx. 80 kbps per connection in each direction.
Auto logout time [min]
Set a time frame (in minutes) for the automatic logout. Default value is 0 (no automatic logout).
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 18
18 en | Web Interface MIC IP ultra 7100i │ MIC IP starlight 7100i
Show alarm inputs Select this checkbox if you want the alarm inputs to appear in the Digital I/O section of the Live page.
Show alarm outputs Select this checkbox if you want the alarm outputs to appear in the Digital I/O section of the Live page.
Allow snapshots
Here you can specify whether the icon for saving individual images (snapshots) should be displayed below the live image. Individual images can only be saved if this icon is visible.
Allow local recording
Here you can specify whether the icon for saving (recording) video sequences on the local memory should be displayed below the live image. Video sequences can only be saved if this icon is visible.
I-frames only stream Here you can specify whether the LIVE page displays a viewing tab for an I-frame only stream.
Show 'Pre-positions'
Here you can specify whether the section Pre-positions of the Live page displays a drop-down box with the list of scenes set in the section Camera > Pre-positions and Tours of the
Configuration page.
Show 'AUX Control'
Here you can specify whether the Live page displays the section Show 'AUX Control'. Here you can specify whether the Live page displays the section Special Functions.
Video file format
Select a file format for the live page display. The MP4 format does not include metadata.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 19
MIC IP ultra 7100i │ MIC IP starlight 7100i Camera | en 19
!

5 Camera

5.1 Installer Menu

Application variant
If you are connecting to MIC-ALM-WAS-24, select “[camera name] - IO“ to allow the
camera to recognize additional inputs and outputs from this device and to allow control of an external washer unit.
Otherwise, select “[camera name].”
Sensor mode
The sensor mode specifies the base resolution and frame rates for the image quality settings. Fast moving scenes use more frame rates (50 fps or 60 fps) for better image quality than slow moving scenes. Adjust this setting as necessary. This higher resolution (HD 1080p) gives maximum detail in these scenes, but can result in motion artifacts for fast-moving objects because of the lower frame rates. Some types of light can show flickering in the image when the frame rate is not synchronized with the mains power frequency. To avoid this, the sensor mode frame rate should be in line with the power frequency: – 50Hz: 25 or 50 fps – 60Hz: 30 or 60 fps Select On to output a mirror image of the camera picture.
Note: Privacy masks are not supported in mirror image mode.
Coding standard
Select the encoding mode: – H.264 – H.265 – H.265 (no B-frames) H.265 (no B-frames) is a restrictive mode for the encoder where it only supports I and P frames. This decreases calculation power so that there can be a higher frame rate (for example, 30 fps for a camera that might be restricted to 25 fps).
Orientation The orientation of the camera. Options: Normal, Inverted, Canted.
SC settings
Click the Default button to restore all camera settings to their original defaults.
Reboot device
Click the Reboot button to reboot the camera. There is a ten (10) second pause before the camera starts its homing phase. During the homing phase, the camera will complete finding the upper and lower tilt limits.
Factory defaults
Click Defaults to restore the factory defaults for the camera. A confirmation screen appears. Allow several seconds for the camera to optimize the picture after a reset. Note: Clicking this button also clears the service-level password. Operators must reset the password before doing anything else.
Caution!
Do not remove power to the unit during a factory default or a firmware update. Wait at least two minutes for the default process to complete. If the unit appears to be "frozen" after two minutes, then reboot the unit. Refer to
Bosch Security Systems User Manual 2020-08 | 1.3 |
Troubleshooting, page 72
for more details.
Page 20
20 en | Camera MIC IP ultra 7100i │ MIC IP starlight 7100i

5.1.1 Positioning

The Positioning feature describes the location of the camera and the perspective in the camera’s field of view. Perspective information is essential to Video Analytics, as it enables the system to compensate for the illusory smallness of distant objects. Only through use of perspective information is it possible to distinguish objects such as persons, bicycles, cars and trucks, and accurately compute their real size and speeds as they move through 3D space. However, to calculate perspective information accurately, the camera must be directed at a single, flat horizontal plane. Multiple and inclined planes, hills, stairs can falsify perspective information and produce incorrect object information such as size and speed.
Mounting position
The mounting position describes the perspective information that is also often called calibration. This parameter is important for Intelligent Tracking. If using Intelligent Tracking, select
Standard.
Standard
VCA Profile
The MIC camera provides the tilt angle and the focal length automatically to complete the global calibration for every potential field of view of the camera.
Height [m]
The height describes the vertical distance from the camera to the ground plane of the captured image. Typically the elevation of the mounted camera above the ground. Enter the height in meters of the position of the camera.
Sketch
The Sketch functionality offers an additional, half-automatic calibration method. This calibration method allows you to describe the perspective in the camera’s field of view by drawing vertical lines, ground lines, and ground angles in the camera image and entering the correct size and angle. Use the Sketch functionality if the result of the automatic calibration is not sufficient. You can also combine this manual calibration with the values for roll angle, tilt angle, height and focal length calculated by the camera or entered manually. Click to improve the automatic calibration. The Sketch Calibration window is displayed.
VCA Profile
Select the appropriate profile.
Global
Select the Global check box to use the global, overall calibration for all AUTODOME and MIC cameras. Alternatively, clear the Global check box to obtain a local calibration and overwrite the global calibration for the selected profile. To do this, select the VCA profile before.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 21
MIC IP ultra 7100i │ MIC IP starlight 7100i Camera | en 21
Notice!
The Sketch functionality is only available for configured and assigned pre-positions. For AUTODOME and MIC cameras, configure the pre-positions of the camera and assign the pre-positions to one of the available 16 VCA profiles before calibration with Sketch. Applications are pre-positions of cameras directed towards different ground planes, an optimized calibration for inclined ground planes or large focal lengths. A local pre-position calibration does not change the global calibration. It is also possible to calibrate pre-positions without entering a global calibration.
Calculate
Select the Calculate check box to obtain the roll angle, tilt angle, height and focal length from the sketched calibration elements - vertical lines, ground lines and angles - you have placed in the camera. Clear the Calculate check box to enter a value manually or to refresh to the values provided by the camera itself.
Tilt angle [°] / Roll angle [°]
Enter the angle manually, or click the refresh icon to obtain values that are provided by any sensors that the camera may have. As an alternative, select the Calculate check box to get values based on the calibration elements that are marked on the image.
Height [m]
Enter the height manually, or click the refresh icon to obtain values that are provided by any sensors that the camera may have. As an alternative, select the Calculate check box to obtain values based on the calibration elements that are marked on the image.
Focal length
Enter the focal length manually, or click the refresh icon to obtain values that are provided by any sensors that the camera may have. As an alternative, select the Calculate check box to obtain values based on the calibration elements that are marked on the image.
Calibrating cameras using the Sketch Calibration window
To determine non-automatically set values:
1. Enter the value for tilt angle, roll angle, height and focal length if the value is known, for example, by measuring the height of the camera above the ground, or reading the focal length from the lens.
2. For each value that is still unknown, select the Calculate check box, then place a calibration element on the camera image. Use these calibration elements to trace individual outlines of the displayed environment in the camera image and define the position and size of these lines and angles.
Click  to place a vertical line across the image.
A vertical line corresponds to a line that is perpendicular to the ground plane, such as a door frame, edge of a building or a lamp post.
Click  to place a line across the ground in the image.
A line on ground corresponds to a line that is on the ground plane, such as a road marking.
Click  to place an angle on the ground in the image.
The angle on ground represents an angle lying on the horizontal ground plane, such as the corner of a carpet or parking bay markings.
3. Adjust the calibration elements to the situation:
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 22
22 en | Camera MIC IP ultra 7100i │ MIC IP starlight 7100i
Enter the real size of a line or angle. To do this, select the line or angle, then enter
the size in the corresponding box. Example: You have placed a line on ground across the lower side of an automobile. You know that the automobile is 4m long. Enter 4m as the length of the line.
Adjust the position or length of a line or angle. To do this, drag the line or angle or
move the end points to the desired position in the camera image.
Remove a line or angle. To do this, select the line or angle, then click the trash can
icon.
Note: Blue lines indicate calibration elements added by you. White lines represent the element as it should be positioned on the camera image based
on the current calibration results or the determined calibration data.
Horizon
If the values correspond, areas on the camera image have a colored background. blue: This area corresponds to the sky. The bottom line of the blue area represents the horizon. Objects that are detected in the blue area cannot be filtered correctly by size or speed. If the camera is installed at a relatively low height in a building, for example, this display is not required, because the entire area covered by the camera is below the horizon.
Notice!
If the distance to the camera (geolocation) is not relevant, it is enough to determine height and focal length in relation to each other. This allows a simple calibration by marking 2-3 persons ‑ each with a vertical line ‑ and setting their size. 1,80m (71 in.) for all is sufficient. Use at least one person in the front and one person in the background of the image for best results.
Coordinate system
The Coordinate system feature describes the position of the camera in a local Cartesian or the global WGS 84 coordinate system. The camera and the objects tracked by the video analytics are displayed on a map. Select the coordinate system and enter the appropriate values in the additional input fields that appear depending on the coordinate system selected.
Cartesian
The Cartesian coordinate system describes each point in the space by a combination of the position on three orthogonal axes X, Y and Z. A right-handed coordinate system is used, where X and Y span the ground plane and Z describes the elevation of the ground plane.
X [m]
The location of the camera on the ground on the X-axis.
Y [m]
The location of the camera on the ground on the Y-axis.
Z [m]
The elevation of the ground plane. To determine the elevation of the camera, add the Z [m] value and the Height [m] value of the camera.
Azimuth [°]
The orientation of the camera in a counter-clockwise angle starting with 0° in the east (WGS
84) or on the X-axis (Cartesian). If the camera is directed towards the north (WGS 84) or the Y-axis (Cartesian), the azimuth is 90°.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 23
MIC IP ultra 7100i │ MIC IP starlight 7100i Camera | en 23
WGS 84
The WGS 84 coordinate system is a spherical coordinate system description of the world and used in many standards including GPS.
Latitude
Latitude is the north-south position of the camera in the spherical coordinate system WGS 84.
Longitude
Longitude is the east-west position of the camera in the spherical coordinate system WGS 84.
Ground level [m]
The elevation of the ground above sea level. To determine the elevation of the camera, add the
Ground level [m] value and the Height [m] value of the camera.
Azimuth [°]
The orientation of the camera in a counter-clockwise angle starting with 0° in the east (WGS
84) or on the X-axis (Cartesian). If the camera is directed towards the north (WGS 84) or the
Y-axis (Cartesian), the azimuth is 90°.

5.2 Scene Mode

A scene mode is a collection of image parameters that are set in the camera when that particular mode is selected (installer menu settings are excluded). Several pre-defined modes are available for typical scenarios. After a mode has been selected, additional changes can be made through the user interface. Customize the mode, if necessary, for the specific requirements of the site by selecting different values for the fields below.
Current mode
Select the mode you wish to use from the drop-down menu. – Standard This mode is optimized for most standard scenes both indoor and outdoor. – Sensitivity boost This mode provides maximum sensitivity in low light scenes by using longer exposure times, resulting in bright images even in extreme low light. – Fast movement This mode is used for monitoring fast moving objects like cars in traffic scenes. Motion artifacts are minimized and the image is optimized for a sharp and detailed picture in color and monochrome. – Vibrant This mode provides a more vivid image with increased contrast, sharpness, and saturation. – Color Only (Traffic) In this mode, the camera does not switch to monochrome mode at low light levels. The mode is optimized to minimize motion artifacts and to capture the color of vehicles/pedestrians and traffic lights, even at night, for scenarios such as city surveillance and traffic monitoring. – Illuminator This mode gives optimized performance when using the MIC illuminator accessory. – Custom mode #1 If necessary, select a custom mode. – Custom mode #2 If necessary, select a second custom mode.
Mode ID
The name of the selected mode is displayed.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 24
24 en | Camera MIC IP ultra 7100i │ MIC IP starlight 7100i
Copy mode to
Select the mode from the drop-down menu to which you wish to copy the active mode.
Note: To restore the default setting of all scene modes, you must click the SC setting.
Restore mode defaults Click Restore Mode Defaults to restore the factory default modes. Confirm you decision.

5.2.1 Picture Settings

Color
White Balance
Adjusts the color settings to maintain the quality of the white areas of the image. – ATW: allows the camera to adjust color reproduction continuously. – AWB hold: places the ATW on hold and saves the color settings. – Extended ATW (default): allows the camera to adjust constantly for optimal color
reproduction. – Manual: Red and Blue gain can be set manually to a desired position. – Sodium lamp auto: Automatically adjusts for sodium vapor light to restore objects to
their original color.
Red Gain
The red gain adjustment offsets the factory white point alignment (reducing red introduces more cyan).
Blue Gain
The blue gain adjustment offsets the factory white point alignment (reducing blue introduces more yellow). It is only necessary to change the white point offset for special scene conditions.
Sodium red level
Adjust the level of red for sodium vapor lighting with the slider from 0 to 255.
Sodium blue level
Adjust the level of blue for sodium vapor lighting with the slider from 0 to 255. Note: The fields Sodium red level and Sodium blue level appear only when the value in the field White balance is “Sodium lamp auto” or “Sodium lamp.”
Saturation
Select the percentage of light or color in the video image. The range of options is from 60% to 200%; the default is 100%.
Color hue
Select the degree of color in the video image. The range of options is from -14° to 14°; the default is 0°.
Exposure and gain control
Gain control
Adjusts the automatic gain control (AGC). – AGC (default): Automatically adjusts the gain to the lowest possible value needed to
maintain a good picture. – Fixed: no enhancement. This setting disables the Max. Gain Level option.
Fixed Gain
Use the slide to select the desired number for fixed gain. The default is 2.
Maximum gain level
To set the Maximum gain level, select Low, Medium or High from the drop-down box.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 25
MIC IP ultra 7100i │ MIC IP starlight 7100i Camera | en 25
AE-response speed
Select the speed of the response of auto exposure. Options are Super slow, Slow, Medium (default), Fast.
Shutter Mode
Fixed: The shutter mode is fixed to a selectable shutter speed. – Automatic exposure: increases camera sensitivity by increasing the integration time on
the camera. This is accomplished by integrating the signal from a number of consecutive video frames to reduce signal noise. If you select this option, the camera disables Shutter automatically.
Shutter
Adjusts the electronic shutter speed (AES). Controls the time period for which light is gathered by the collecting device. The default setting is 1x (60 Hz: 1/30, 50 Hz: 1/25)
Maximum automatic exposure
Use this field to limit the integration time when Frame Integration is active. The range of options is from 1/4 to 1/30 (default).
Default shutter limit
The camera tries to hold this shutter value as long as sufficient ambient light is available in the scene. The range of options is from 1/60 to 1/10000. The default value is 1/120 for all modes except
Motion (default 1/500).
Backlight compensation
The function will ignore small areas of high illumination directly into the camera. The function increases the brightness of the overall screen to make sure that subjects and the larger portion of the scene remain bright. Select Off to stop Backlight compensation. (Default) Select On to start Backlight compensation. Note: You cannot use High dynamic range and Backlight compensation at the same time. (When High dynamic range is On, Backlight compensation is Off.) ※ Backlight compensation does not work in Fixed shutter mode.
Day/night
Night mode
Selects night mode (B/W) to enhance lighting in low light scenes. Select from the following options: – Monochrome: Forces the camera to stay in Nigh Mode and transmit monochrome images. – Color: The camera does not switch to Night Mode regardless of ambient light conditions. – Auto (default): The camera switches out of Night Mode after the ambient light level
reaches a pre-defined threshold.
Night mode threshold
Adjusts the level of light at which the camera automatically switches out of night mode (B/W) operation. Select a value between 10 and 55 (in increments of 5; default 40). The lower the value, the earlier the camera will switch to color mode.
Night mode priority
Select the option to which the camera should give priority while in night mode: – Motion – Color (default)
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 26
26 en | Camera MIC IP ultra 7100i │ MIC IP starlight 7100i
Night mode shutter
Controls the time period for which light is gathered by the collecting device while in night mode. Values are ¼, 1/8, 1/15, and 1/30; the default is 1/15.

5.2.2 Enhance

All settings on this page except for Intelligent Noise Reduction are scene-mode specific. This means that sharpness/noise suppression/HDR can be adjusted on each scene mode.
High dynamic range
The High dynamic range mode uses an electronic shutter to capture multiple images with different exposure times and to reproduce a high-contrast frame. The output frame combines the bright area captured by the high-speed shutter image and the dark area captured by the low-speed shutter image. The result is that you can view details in both the bright areas (highlights) and the dark areas (shadows) of a scene at the same time. Select On to start High dynamic range. (Default) Select Off to stop High dynamic range. Note: You cannot use High dynamic range and Backlight compensation at the same time. (When High dynamic range is On, Backlight compensation is Off.) ※ High dynamic range does not work in Fixed shutter mode.
Stabilization
Stabilization reduces camera shake in both the vertical and horizontal axis. The camera compensates for the movement of the image by up to 2% of the image size. This feature is ideal for cameras mounted on a pole or mast, or on another location that shakes frequently. – On - Stabilization is always on. – Off - Stabilization is disabled. – Auto - Stabilization activates automatically when the camera detects vibration greater
than the set threshold.
Sharpness mode Select the appropriate sharpness mode. Options are Manual and Auto.
Sharpness level
This field is active when Sharpness mode is set to Manual. Adjust the level of sharpness of the video image (from 1 to 15) using the slider. Adjustments to the Sharpness level appear on the OSD.
Gamma correction
This function lets you adjust the image contrast in the original scene, to make it lighter or darker. Contrast lets you get more detail in a dark area, or get video with more contrast. Use the slider to adjust the Gamma correction value. The higher the number, the better the image contrast.
Fine edge mode
This function makes video sharper for scenes with related colors and not much contrast. Examples of scenes for which to use this function are scenes with a forest or a lawn.
Black line enhancement
This function increases the sharpness of objects in an image by adding a black line around the objects. This effect makes more of a distinction between one element and another in a scene. The default value is Auto.
Intelligent Defog
With the Intelligent Defog mode feature, visibility can be improved significantly when viewing foggy or other low-contrast scenes. Select Auto to activate the Intelligent Defog feature automatically as needed.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 27
MIC IP ultra 7100i │ MIC IP starlight 7100i Camera | en 27
!
Select Off to disable the feature. Select Extreme to activate the feature for viewing images of very low contrast.
Intelligent Defog intensity
Select the amount of intensity for the defog feature.
Note: This field appears only when the option in Intelligent Defog is "On" or "Auto."
Noise reduction
By default, this option is On. Noise reduction On enables temporal noise reduction, which reduces random video noise in the picture by averaging pixels across time if the difference between them is below a threshold. Off disables temporal noise reduction.
2D noise reduction level
This field operates in conjunction with the field Noise reduction to reduce the noise introduced by the brightness of the image. When Noise reduction is set to “On,” then the 2D noise reduction level field is active. Select the appropriate level of noise reduction, from 1 to 5 (2 is the default).
3D noise reduction level
This field operates in conjunction with the field Noise reduction to reduce the noise introduced by movements in the scene. When Noise reduction is set to “On,” then the 3D noise reduction level field is active. Select the appropriate level of noise reduction, from 1 to 5 (2 is the default).
Intelligent Dynamic Noise Reduction
Select On to activate intelligent Dynamic Noise Reduction (DNR) which reduces noise based on motion and light levels.

5.2.3 Scene Mode Scheduler

The scene mode scheduler is used to determine which scene mode should be used during the day and which scene mode should be used during the night.
1. Select the mode you wish to use during the day from Marked range drop-down box.
2. Select the mode you wish to use during the night from Unmarked range drop-down box.
3. Use the two slider buttons to set the Time ranges.

5.3 Encoder Profile

For the video signal encoding, you can select a code algorithm and you can change the presets for the profiles. You can adapt the video data transmission to the operating environment (for example network structure, bandwidth, data load). To this end, the camera simultaneously generates two data streams (Dual Streaming), which compression settings you can select individually, for example one setting for transmissions to the Internet and one for LAN connections. Pre-programmed profiles are available, each giving priority to different perspectives. You can change individual parameter values of a profile and you can also change the name. You can switch between profiles by clicking the appropriate tabs.
Caution!
The profiles are rather complex. They include a large number of parameters that interact with one another, so it is generally best to use the default profiles. Change the profiles only once you are fully familiar with all the configuration options.
Note: In the default setting, Stream 1 is transmitted for alarm connections and automatic connections.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 28
28 en | Camera MIC IP ultra 7100i │ MIC IP starlight 7100i
Notice!
All parameters combine to make up a profile and are dependent on one another. If you enter a setting that is outside the permitted range for a particular parameter, the nearest permitted value will be substituted when the settings are saved.
Profile name
Profile number Default Profile name Description
Profile 1 HD Image Optimized For an HD image, the video bit rate and frame
quality are adjusted to ensure that the picture quality is the priority.
Profile 2 HD Balanced For an HD image, the video bit rate and frame
quality are adjusted to a median profile for everyday use.
Profile 3 HD Bit Rate
Optimized
For an HD image, the video bit rate and frame quality are adjusted to ensure that the bit rate is the priority.
Profile 4 SD Image Optimized For an SD image, the video bit rate and frame
quality are adjusted to ensure that the picture quality is the priority.
Profile 5 SD Balanced For an SD image, the video bit rate and frame
quality are adjusted to a median profile for everyday use.
Profile 6 SD Bit Rate
Optimized
For an SD image, the video bit rate and frame quality are adjusted to ensure that the bit rate is the priority.
Profile 7 DSL Optimized Ideal for encoding on a DSL uplink where bit rate
limitations are critical.
Profile 8 3G Optimized Ideal for encoding on a 3G uplink where bit rate
limitations are critical.
If required, enter a new name for the profile.
Bit rate optimization
The bit rate optimization defines the optimization strength. These must be combined with the appropriate scene mode. The Bit rate optimization and Maximum bit rate work in a quality­driven mode. The encoder generates a bit rate up to the maximum setting if the scene requires it. For maximum image quality, apply minimum bit rate reduction (Maximum quality). This will also greatly increase the file size. If maximum bit rate reduction is applied, the image will have less quality, but the file size decreases significantly (Minimum bit rate). Select the necessary bit rate optimization setting: – Off: bit rate optimization is disabled – Maximum quality High quality Medium Low bit rate Minimum bit rate
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 29
MIC IP ultra 7100i │ MIC IP starlight 7100i Camera | en 29
Maximum bit rate
This maximum bit rate is not exceeded under any circumstances. Depending on the video quality settings for the I- and P-frames, this fact can result in individual images being skipped. The value entered here must be at least 10% higher than the value entered in the Target bit
rate field. If the value entered here is too low, it will be adjusted automatically.
Averaging period
Select the appropriate averaging period as a means of stabilizing the long term bit rate.
Target bit rate
To optimize use of the bandwidth in the network, limit the data rate for the device. The target data rate should be set according to the desired picture quality for typical scenes with no excessive motion. For complex images or frequent changes of image content due to frequent movements, this limit can temporarily be exceeded up to the value entered in the Maximum bit rate field.
Note: You can change the value in this field only if you select a duration in the field Averaging period. If you do not select an Averaging period, then the field Target bit rate is greyed out.
Encoding interval
The Encoding interval slider determines the interval at which images are encoded and transmitted. This can be particularly advantageous with low bandwidths. The image rate is displayed next to the slider.
Video resolution
Select the desired resolution for the video image.
Note: The value in this field adjusts the resolution for SD streams only.
Expert settings
If necessary, use the expert settings to adapt the I-frame quality and the P-frame quality to specific requirements. The setting is based on the H.264 quantization parameter (QP).
I-frame distance
Use the slider to set the distance between I-frames to Auto or to between 3 and 255. An entry of 3 means that every third image is an I-frame. The lower the number, the more I-frames are generated. Note that the values supported depend on the GOP structure setting. For example, only even values are supported with IBP; if you have selected IBBP, only 3 or multiples of 3 are supported.
Allow enhanced prediction
This function allows for multiple references in H.264 and H.265 streams, which can reduce bitrate. Some decoders do not support this feature and therefore can be disabled.
Min. P-frame QP
This parameter allows you to adjust the image quality of the P-frame and to define the lower limit for the quantization of the P-frames, and thus the maximum achievable quality of the P­frames. In the H.264-protocol, the Quantization Parameter (QP) specifies the degree of compression and thus the image quality for every frame. The lower the quantization of the P­frame (QP value), the higher the encoding quality (and thus the best image quality) and the lower the frame refresh rate depending on the settings for the maximum data rate under network settings. A higher quantization value results in low image quality and lower network load. Typical QP values are between 18 and 30. The basic setting Auto automatically adjusts the quality to the settings for the P-frame video quality.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 30
30 en | Camera MIC IP ultra 7100i │ MIC IP starlight 7100i
I/P-frame delta QP
This parameter sets the ratio of the I-frame quantization (QP) to the P-frame quantization (QP). For example, you can set a lower value for I-frames by moving the slide control to a negative value. Thus, the quality of the I-frames relative to the P-frames is improved. The total data load will increase, but only by the portion of I-frames. The basic setting Auto automatically adjusts to the optimum combination of movement and image definition (focus). To obtain the highest quality at the lowest bandwidth, even in the case of increased movement in the picture, configure the quality settings as follows:
1. Observe the coverage area during normal movement in the preview images.
2. Set the value for Min. P-frame QP to the highest value at which the image quality still
meets your needs.
3. Set the value for I/P-frame delta QP to the lowest possible value. This is how to save
bandwidth and memory in normal scenes. The image quality is retained even in the case
of increased movement since the bandwidth is then filled up to the value that is entered
under Maximum bit rate.
Background delta QP
Select the appropriate encoding quality level for a background region defined in Encoder Regions. The lower the QP value, the higher the encoding quality.
Object delta QP
Select the appropriate encoding quality level for an object region defined in Encoder Regions. The lower the QP value, the higher the encoding quality.
Default Click Default to return the profile to the factory default values.

5.4 Encoder Streams

Note: If you access this menu while the camera is recording, the following message appears at the top of the page: Recording is currently active. Therefore, for ‘Current profile’ the respective stream profile selected for recording is displayed for information.
Stream prioritization
Select the stream that should not drop any frame. For each stream, select the appropriate options in the fields that follow.
Coding standard
Select the coding standard (H.264 or H.265) for the stream.
VCA overlays
Select the video stream into which to embed VCA overlays.
Non-recording profile
Select one of the following profiles for each stream:
Profile number Default Profile name Description
Profile 1 HD Image Optimized For an HD image, the video bit rate and frame
quality are adjusted to ensure that the picture quality is the priority.
Profile 2 HD Balanced For an HD image, the video bit rate and frame
quality are adjusted to a median profile for everyday use.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 31
MIC IP ultra 7100i │ MIC IP starlight 7100i Camera | en 31
Profile number Default Profile name Description
Profile 3 HD Bit Rate
Optimized
Profile 4 SD Image Optimized For an SD image, the video bit rate and frame
Profile 5 SD Balanced For an SD image, the video bit rate and frame
Profile 6 SD Bit Rate
Optimized
Profile 7 DSL Optimized Ideal for encoding on a DSL uplink where bit rate
Profile 8 3G Optimized Ideal for encoding on a 3G uplink where bit rate
Note: Non-recording profiles (streams) are I-frame only. Note: Each stream can have its own independent profile which does not need to be shared
with other streams.
Active profile Each stream shows its active profile. When you click the name, the Encoder Profile (stream (number), profile (number)) window appears. Refer to the chapter
for details.
Video resolution
Select the desired resolution for the video image.
Note: Each stream can have its full resolution. Encoding interval
The Encoding interval slider determines the interval at which images are encoded and transmitted. This can be particularly advantageous with low bandwidths. The frame rate is displayed next to the slider. Click Test to see when and if a specific stream will drop frames.
For an HD image, the video bit rate and frame quality are adjusted to ensure that the bit rate is the priority.
quality are adjusted to ensure that the picture quality is the priority.
quality are adjusted to a median profile for everyday use.
For an SD image, the video bit rate and frame quality are adjusted to ensure that the bit rate is the priority.
limitations are critical.
limitations are critical.
Encoder Profile, page 27

5.5 Encoder Statistics

Stream
Identifies the current stream (1, 2, or JPEG).
Zoom
Identifies the current zoom factor of the camera (1x, 2x, 4x, or 8x).
Averaging period
Select the appropriate averaging period as a means of stabilizing the long term bit rate.

5.6 Privacy Masks

Note: The sequence of fields in the GUI may not match the sequence of the fields in this
section of the User Manual. In this section of the User Manual, fields appear in a more logical functional sequence, identifying the sequence to create a new privacy mask, and then to update a privacy mask.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 32
32 en | Camera MIC IP ultra 7100i │ MIC IP starlight 7100i
Privacy Masks block specific areas of a scene from being seen in the camera's field of view.
This can be useful when public spaces are in the coverage area or monitoring will be limited to a particular zone. The areas covered are indicated by a colored pattern (Black, White, or Gray) in the video image. The activated masked areas are filled with the selected pattern in live view. You can define a total of thirty-two (32) privacy masks in the camera. A total of eight (8) masks can be in view at the same time.
Privacy mask
Select the number of the Privacy mask. A colored rectangle appears in the unlabeled video preview window above the Set button. Use the mouse to define the area for each privacy mask. Privacy Masks can have multiple corners (which are blue in the preview window) and can form any convex shape. The default mask template has four corners. You can add or delete corners as needed: – To add a corner, double-click the side of the mask where you want to add the corner. – To delete a corner, double-click the corner to remove. – To amend the shape of a zone, place the cursor over the edge of the zone, hold down the
mouse button and drag the edge of the zone to the required position. – To reposition a zone, place the cursor over the zone, hold down the mouse button and
drag into position.
Notice!
Draw the mask at 50% optical zoom or less for improved masking performance. Draw the mask 10% larger than the object to ensure that the mask completely covers the object as the camera zooms in and out.
Notice!
When MIC is canted, Privacy Masks should not be created for scene objects less than 2 m (6 feet) distance from camera.
Pattern
Select the color of the mask as it will appear in live video: Black, White, or Gray. If you select the PatternAuto,” the camera adjusts to the brightness or darkness of the background scene of the video. In other words, the color of the Privacy mask is the most prevalent of the three (Black, White, or Gray) in the background scene that the Privacy mask covers.
Enabled
Select this check box to draw the mask for the corresponding Privacy mask zone. Clear this check box to erase the mask for an individual Privacy mask zone. – To hide all privacy masks, click the check box Disable masks.
Note: You can disable masks individually by deselecting the check box Disable masks.
Mask enlargement
Select this check box to enlarge all masks automatically while the camera is in motion.
Zoom threshold
Click this check box to select the current zoom position at which the mask will appear as the camera zooms in or be hidden as the camera zooms out.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 33
MIC IP ultra 7100i │ MIC IP starlight 7100i Camera | en 33

5.7 Lens Settings

Focus
Autofocus
Continuously adjusts the lens automatically to the correct focus for the sharpest picture. – One Push (default; commonly called “Spot Focus”): activates the Auto Focus feature after
the camera stops moving. Once focused, Auto Focus is inactive until the camera is moved
again. – Auto Focus: Auto Focus is always active. – Manual: Auto Focus is inactive.
Focus speed
Use the slider (from 1 to 8) to control how fast the Auto focus will readjust when the focus becomes blurred.
IR focus correction
Optimizes the focus for IR lighting. Options are: On, Off (default).
Day near limit [m]
Select the distance (in meters), from 0.1 to 20 m, for the minimum distance of the zoom focus during the day.
Night near limit [m]
Select the distance (in meters), from 0.1 to 20 m, for the minimum distance of the zoom focus during the night.
Iris
Auto iris
Automatically adjusts the lens to allow the correct illumination of the camera sensor. This type of lens is recommended for use where there are low light or changing light conditions. – Constant (default): camera constantly adjusts to varying light conditions (default).
If you select this option, the camera makes the following changes automatically:
Gain Control: switches to AGC.
Shutter Speed: switches to default. – Manual: camera must be manually adjusted to compensate for varying light conditions.
Auto iris level
Increases or decreases brightness according to the amount of light. Type a value between 1 and 15.
Zoom
Maximum zoom speed
Controls the zoom speed.
Zoom limit
Select the appropriate limit for zooming the camera: 20x, 30x.
Digital zoom
Digital zoom is a method of decreasing (narrowing) the apparent angle of view of a digital video image. It is accomplished electronically, without any adjustment of the camera's optics, and no optical resolution is gained in the process. Select On to enable this feature. Select Off to disable this feature. Super resolution zoom is always on when digital zoom is <1.5X. This feature is not available at higher zoom values.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 34
34 en | Camera MIC IP ultra 7100i │ MIC IP starlight 7100i

5.8 PTZ Settings

Auto pan speed
Continuously pans the camera at a speed between right and left limit settings. Type a value between 1 and 60 (expressed in degrees), inclusive. The default setting is 30.
Inactivity
Selects the time period the dome must be not controlled until the inactivity event will be executed. – Off (default): camera remains on a current scene indefinitely. – Pre-position 1: camera returns to Pre-position 1. – Previous AUX: camera returns to the previous AUX activity.
Inactivity period
Determines the behavior of the camera when the control for the camera is inactive. Select a time period from the pull-down list (3 s - 24 h). The default setting is 2 minutes.
Number of sectors
Select the appropriate number of sectors (for example, 4, 6, 12, or 16). Note: The number that you select in this field determines the number of sectors that appear in the Sectors page (below).
Auto pivot
The Auto pivot tilts the camera through the vertical position as the camera is rotated to maintain the correct orientation of the image. Set the Auto Pivot to On (default) to automatically rotate the camera 180º when following a subject traveling directly beneath the camera. To disable this feature, click Off.
Freeze frame
Select On to freeze the image while the camera moves to a predetermined scene position.
Azimuth
Select On to display azimuth/elevation readings. Select Off to hide azimuth/elevation readings.
Maximum pan speed [%]
Select the maximum pan speed (in percent). Settings range from 1 to 100. The default is 100. Note: If you would like to pan/tilt manually, or to use recording Tour A / Tour B, while using the “IVA while moving” feature, then you must set the value in this field to <5.
Maximum tilt speed [%]
Select the maximum tilt speed (in percent). Settings range from 1 to 100. The default is 100. Note: If you would like to pan/tilt manually, or to use recording Tour A / Tour B, while using the “IVA while moving” feature, then you must set the value in this field to <5.
Tracking zoom-out limit [%]
This parameter defines the zoom ratio percentage to which the camera zooms out after Tracking idel time [s] stops tracking, or if Intelligent Tracking loses visibility of an object being tracked. This allows the camera to re-acquire the target in a new, wider FoV. Settings range from 0 to 100. The default is 50.
Tracking idle time [s]
This parameter allows the camera to stop tracking motion of certain objects, such as a tree or a flag swaying in the wind, in a confined area after the specified number of seconds. Settings range from 5 to 120. The default is 30.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 35
MIC IP ultra 7100i │ MIC IP starlight 7100i Camera | en 35
Auto pan left limit
Sets the left Auto Pan limit of the camera. Use the preview window to move the camera to the left pan limit and click the button. The camera will not move past this limit when in Auto Pan Between Limits mode (AUX 2 ON).
Auto pan right limit
Sets the right Auto Pan limit of the camera. Use the preview window to move the camera to the right pan limit and click the button. The camera will not move past this limit when in Auto Pan Between Limits mode (AUX 2 ON).
Notice!
Possible unintended camera operation When setting hard pan limits, ensure that you set the left limit and the right limit at least 10° apart. Pan limits of less than 10° apart could prevent the camera from operating properly.
Tilt up limit
Sets the upper tilt limit of the camera. Use the preview window to move the camera to the tilt limit and click the button.
Pan limit left
Set the appropriate pan limit on the left.
Pan limit right
Set the appropriate pan limit on the right.
Tour A / Tour B
Starts and stops the recording of a recorded (guard) tour. The camera can make up to two (2) recorded tours. A recorded tour saves all manual camera movements made during the recording, including its rate of pan, tilt and zoom speeds, and other lens setting changes. The tour does not capture camera video during the recording of the tour. Note 1: You can save a total of 15 minutes of recorded actions between the two tours. To record a tour:
1. Click the Start Recording button. The system prompts you to overwrite the existing tour.
2. Click Yes to overwrite the existing tour movements.
3. Click the View Control link, under the image cameo, to access the directional and zoom
controls.
4. Use the View Control dialog box to make the necessary camera movements.
5. Click the Stop Recording button to save all actions.
Note: Tour B is now intended for use with the 'IVA while moving' functions.
Compass
The camera allows a user to display the compass heading of the camera in the lower-right corner of the image display. The camera displays the cardinal or intercardinal (N, NE, E, SE, S, SW, W, NW) heading in which the camera is pointing. You must first calibrate the camera to North before the camera displays accurate compass headings. The camera uses this calibration, usually set to magnetic North, as the zero degree pan position and as the North compass heading. The camera then displays the compass heading based on the number of degrees from the North calibration point. To set the North calibration point:
1. Determine the North compass heading, then move the camera to that position.
2. Select the radio button On for the parameter Compass.
3. Click the button next to North point to set the calibration point.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 36
36 en | Camera MIC IP ultra 7100i │ MIC IP starlight 7100i
North point
Click the Set button to overwrite the existing North point. A dialog box appears with the
message, “Overwrite North point?” To confirm, click OK. To cancel, click Cancel.
Click the Clear button to reset the North point to factory defaults. A dialog box appears
with the message, “Reset North point to factory defaults?” To confirm, click OK. To cancel, click Cancel.
Alternative home position
Click Set to set the alternative home position for the camera. Click Clear to clear the alternative home position.

5.9 Pre-positions and Tours

The camera can store up to 256 preset scenes. You can define the individual scenes that comprise a Pre-position Tour. You define individual pre-position scenes, then use these scenes to define the Pre-position Tour. The tour starts from the lowest scene number in the tour and progresses sequentially to the highest scene number in the tour. The tour displays each scene for a specified dwell time before advancing to the next scene. By default, all scenes are part of the Pre-position Tour unless removed.
To define a Pre-position Tour:
1. Create the individual pre-positions. By default, all scenes in the list Pre-positions are in the Pre-position Tour.
2. To remove a pre-position from the tour, select the pre-position in the list and uncheck the box Include in standard tour (marked with *).
3. Select a dwell time from the drop-down list Standard pre-position tour.
4. To start the Pre-position Tour: Return to the Live page. Click AUX Control. Type 8 in the input box and click AUX on.
5. To stop the tour, type 8 and click AUX off.
To define a Custom tour
1. Create the individual pre-positions.
2. To add a pre-position into the custom tour, select the pre-position from the general list and click the triangle button to copy it to the custom tour list.
3. Adjust the custom tour sequence by moving preposition up or down.
4. Select a dwell time from the drop-down list Custom tour .
5. To start the Custom tour: Return to the Live page. Select Special Functions. Click AUX Control. Type 7 in the input box and click AUX on.
6. To stop the tour, type 7 and click AUX off.
Sequence settings
White light (marked with #)
Select this checkbox to include white light in the scene.
Include in standard tour (marked with *)
Select this checkbox to include the pre-position in the standard tour.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 37
MIC IP ultra 7100i │ MIC IP starlight 7100i Camera | en 37
Upload
Click the button to upload the tour configuration to the camera.
Dwell times
Standard pre-position tour Select the dwell time in seconds or minutes for the Standard pre-position tour.
Custom pre-position tour Select the dwell time in seconds or minutes for the Custom pre-position tour.

5.10 Pre-position settings

Pre-position
Select the number of the pre-position for which to save specific settings.
Name Change the name of the pre-position if needed. Click Set to save the new name.
Automatic exposure
Select the automatic exposure mode. Options are Full-screen or Defined
Full-screen (Default)
The camera computes the lighting condition of the entire scene. Then the camera determines the optimum level of iris, gain, and shutter speed.
Defined
Move and adjust the size of the green box to cover an interesting area. The camera computes the lighting condition to the center spot of the specified area. Then the camera determines the optimum level of iris, gain, and shutter speed to get an image.
Note: the size shape of the specified area does not matter.
Day near limit [m]
Select the distance (in meters), from 0.1 to 20 m, for the minimum distance of the zoom focus during the day.
Night near limit [m]
Select the distance (in meters), from 0.1 to 20 m, for the minimum distance of the zoom focus during the night.
White light illuminators
Select On to turn on the White light illuminators. Select Off to turn off the White light illuminators.
White light intensity
Select the degree of intensity of the White light.

5.11 Pre-position mapping

Pre-position mapping allows you to map a function to a pre-position action. This feature works for Bosch protocols and for non-Bosch protocols.
Action
Select the appropriate action: Show or Set.
Pre-position
Enter the number of the pre-position to map.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 38
38 en | Camera MIC IP ultra 7100i │ MIC IP starlight 7100i
Function
Select the appropriate function from the drop-down list.
Start auto pan Gamma mode off
Start auto pan with limit Gamma mode smart 1
Stop auto pan Gamma mode smart 2
Start custom tour Gamma mode smart 3
Stop custom tour IR focus correction on
Start tour IR focus correction off
Stop tour OSD feedback on
Start playback A OSD feedback off
Stop playback A IR mode on
Start playback B IR mode off
Stop playback B IR mode auto
Compass on Visible light on
Compass off Visible light off
Azimuth on Visible light inhibit on
Azimuth off Visible light inhibit off
Stabilization auto Auto tracker on
Stabilization on Auto tracker off
Stabilization off Privacy mask on
WDR auto Privacy mask off
WDR on Acknowledge alarms
WDR off Wiper continuous
Night mode auto Wiper intermittent
Night mode on Wiper on shot
Night mode off Wiper off
Gamma mode on

5.12 Sectors

Sector The camera’s pan capability is divided into equal sectors (2, 4, 8, 16), as defined in PTZ Settings > Number of sectors, for a total of 360°.
To define a title for sectors:
1. Place the cursor in the input box to the right of the sector number.
2. Type a title for the sector, up to 20 characters long.
3. To blank the sector, click the check box to the right of the sector title.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 39
MIC IP ultra 7100i │ MIC IP starlight 7100i Camera | en 39
No white light
Specifically for MIC cameras using the IR/White light illuminator: Select this check box to prevent activation of the White light illuminator in the corresponding sectors, such as those which include highways / roads where White light might create a hazardous situation such as blinding a driver. When this check box is selected, no White lights will activate for Presets stored in the corresponding sector.

5.13 Miscellaneous

Fast address
This parameter allows the appropriate camera to be operated via the numerical address in the control system. Enter a number between 0000 and 9999, inclusive, to identify the camera.

5.14 Illuminator

Notice!
The illuminator fields are available only when an illuminator is attached to a MIC camera.
The default intensity for illumination (both IR and White light) is 33%.
IR mode
Select the appropriate IR mode to control the IR illuminators: – Off - This mode turns off the illuminators. – Auto - This mode activates the 850 nm IR array in low-light scenes (for example, at night),
and deactivates the IR array in scenes with bright light (for example, during a sunny day).
Auto (covert only) - This mode activates the 940 nm IR array, and functions as Auto does.
IR operation range
Select the appropriate range of operation for the IR illuminator: – 1x to 30x (default) – 5x to 30x – 10x to 30x – 20x to 30x
Maximum IR intensity
Select the percentage of maximum intensity of the infrared (IR) light, from 0 to 100.
No white light Select On to disable the field White light illuminators. The options in the field White light illuminators are disabled. Select Off to enable field White light illuminators.
White light illuminators
Select On to turn on the White light illuminators. Select Off to turn off the White light illuminators.
White light intensity
Select the degree of intensity of the White light.
Note: This field is active only if the White light illuminator is On.
White light timeout
Select On to enable a timeout for the White light feature. Select Off to disable the timeout.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 40
40 en | Camera MIC IP ultra 7100i │ MIC IP starlight 7100i
The timeout turns OFF the White light, after the light has been ON but idle for some time, to help to retain the life of the LEDs.
White light timeout [min]
Select the number of minutes (from 1 to 30) after which the White light will turn off after activation.
Wiper
Controls the wiper of the MIC cameras. Options are: – Off: Turns off the wiper. – On: Wiper wipes continuously until deactivated manually, or until it has been on for five
minutes (after which the camera will stop the wiper automatically).
Intermittent: Wipes twice, then stops. Every 15 seconds, this cycle repeats until users
select another option in this field.
One shot: Wipes five times, then turns off.
Wiper/washer
Click Start to start the wiper/washer. Click Stop to stop the wiper/washer.

5.15 Audio

Audio
You can set the gain of the audio signals to suit your specific requirements. The live video image is shown in the window to help you check the audio source. Your changes are effective immediately. If you connect via Web browser, you must activate the audio transmission on the 'Live' functions page. For other connections, the transmission depends on the audio settings of the respective system. The audio signals are sent in a separate data stream parallel to the video data, and so increase the network load. The audio data is encoded according to the selected format and requires additional bandwidth. If you do not want any audio data to be transmitted, select Off.
Input volume
Set the input volume using the slide. Values range from 0 to 119.
Line Out
Set the line output gain using the slider. Values range from 0 to 115.
Recording format Select a format for audio recording. The default value is AAC 48 kbps. You can select AAC 80 kbps, G.711 or L16 depending on the required audio quality or sampling rate.
AAC audio technology is licensed by Fraunhofer IIS. (http://www.iis.fraunhofer.de/amm/)

5.16 Pixel Counter

The number of horizontal and vertical pixels covered by the highlighted area is displayed below the picture. With these values you can check whether the requirements for specific functions, for example, identification tasks, are fulfilled.
1. Click Freeze to freeze the camera image if the object that you want to measure is moving.
2. To reposition a zone, place the cursor over the zone, hold down the mouse button and drag into position.
3. To change the shape of a zone, place the cursor over the edge of the zone, hold down the mouse button and drag the edge of the zone to the required position.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 41
MIC IP ultra 7100i │ MIC IP starlight 7100i Recording | en 41

6 Recording

6.1 Introduction to recording

Images can be recorded to an appropriately configured iSCSI system or, for devices with an SD slot, locally to an SD card.
SD cards are the ideal solution for shorter storage times and temporary recordings. They can be used for local alarm recording or to improve the overall reliability of video recording. For long-term authoritative images use an appropriately sized iSCSI system.
Two recording tracks are available (Recording 1 and Recording 2). The encoder streams and profiles can be selected for each of these tracks for both standard and alarm recordings. Ten recording profiles are available where these recording tracks can be defined differently. These profiles are then used for building schedules.
A Video Recording Manager (VRM) can control all recording when accessing an iSCSI system. The VRM is an external program for configuring recording tasks for video servers.

6.2 Storage Management

6.2.1 Device manager

An external Video Recording Manager (VRM) system for the unit is configured via the Configuration Manager. The Managed by Video Recording Manager software box is only an indicator; it cannot be changed here. If the Managed by Video Recording Manager software box is checked, you are not able to configure any further recording settings on this page.

6.2.2 Recording media

Select a media tab to connect to the available storage media.
iSCSI Media
To use an iSCSI system as the storage medium, a connection to the desired iSCSI system is required to set the configuration parameters. The storage system selected must be available on the network and completely set up. It must have an IP address and be divided into logical drives (LUNs).
1. Enter the IP address of the required iSCSI destination in the iSCSI IP address field.
2. If the iSCSI destination is password protected, enter the password into the Password field.
3. Click Read. – The connection to the IP address is established.
The Storage overview field displays the logical drives.

6.2.3 Activating and configuring storage media

Available media or iSCSI drives must be transferred to the Managed storage media list, activated, and configured for storage.
Note:
A iSCSI target storage device can only be associated with one user. If a target is being used by another user, ensure that the current user no longer needs the target before decoupling that user.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 42
42 en | Recording MIC IP ultra 7100i │ MIC IP starlight 7100i
1. In the Storage overview section, double-click a storage medium, an iSCSI LUN or one of the other available drives. – The medium is added as a target in the Managed storage media list. – Newly added media is shown as Not active in the Status column.
2. Click Set to activate all media in the Managed storage media list. – The Status column shows all media as Online.
3. Check the box in the Rec. 1 or Rec. 2 column to specify the recording tracks to be recorded on the target selected.

6.2.4 Formatting storage media

All recordings on a storage medium can be deleted at any time. Check the recordings before deleting and back-up important sequences on the computer's hard drive.
1. Click a storage medium in the Managed storage media list to select it.
2. Click Edit below the list.
3. Click Format in the new window to delete all recordings in the storage medium.
4. Click OK to close the window.

6.2.5 Deactivating storage media

A storage medium in the Managed storage media list can be deactivated. It is then no longer used for recordings.
1. Click a storage medium in the Managed storage media list to select it.
2. Click Remove below the list. The storage medium is deactivated and removed from the list.

6.3 Recording Profiles

A recording profile contains the characteristics of the tracks that are used for recording. These characteristics can be defined for ten different profiles. The profiles can then be assigned to days or times of day on the Recording Scheduler page. Each profile is color-coded. The names of the profiles can be changed on the Recording Scheduler page. To configure a profile, click its tab to open its settings page. – To copy the currently visible settings to other profiles, click Copy Settings. A window
opens to select the target profiles for the copied settings.
If you change a profile’s settings, click Set to save. – If necessary, click Default to return all settings to their factory defaults.
Stream profile settings
Select the encoder profile setting that is to be used with stream 1 and 2 when recording. This selection is independent of the selection for live stream transmission. (The properties of the encoder profiles are defined on the Encoder Profile page.)
Pre-position
Select the appropriate pre-position to record. Options are Tour A, Tour B, Custom Tour, and configured pre-positions.
Settings for selected recordings
Recording includes
You can specify whether, in addition to video data and metadata (for example alarms, VCA data and serial data) should also be recorded. Including metadata could make subsequent searches of recordings easier but it requires additional memory capacity.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 43
MIC IP ultra 7100i │ MIC IP starlight 7100i Recording | en 43
!
Caution!
Without metadata, it is not possible to include video content analysis in recordings.
Select what is to be included in the recordings: – Audio: If audio is not enabled, Off is shown. Click on Off and the page is redirected to
the Audio section.
Metadata.
Standard recording
Select the mode for standard recordings: – Continuous: the recording proceeds continuously. If the maximum recording capacity is
reached, older recordings are overwritten automatically.
Pre-alarm: recording takes place in the pre-alarm time, during the alarm and during the
post-alarm time only.
Off: no automatic recording takes place.
Stream
Select the stream to be used for standard recordings: – Stream 1 Stream 2 I-frames only
Alarm recording
Select a period for the Pre-alarm time from the list box. Select a period for the Post-alarm time from the list box.
Alarm stream
Select the stream to be used for alarm recordings: – Stream 1 Stream 2 I-frames only
Check the encoding interval and bit rates from profile: box and select an encoder profile to set the associated encoding interval for alarm recording.
Check the Export to account box to send standard H.264 or H.265 files to the target whose address is displayed. If the target has not yet been defined, click Configure accounts to jump to the Accounts page where the server information can be entered.
Alarm triggers *
Select the alarm type that is to trigger an alarm recording: – Alarm input Analysis alarm Video loss Select the Virtual alarm sensors that are to trigger a recording, via RCP+ commands or alarm scripts, for example.

6.4 Maximum Retention Time

Recordings are overwritten when the retention time entered here has expired. 4 Enter the required retention time in days for each recording track.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 44
44 en | Recording MIC IP ultra 7100i │ MIC IP starlight 7100i
Make sure that the retention time does not exceed the available recording capacity.

6.5 Recording Scheduler

The recording scheduler allows you to link the created recording profiles with the days and times at which the camera's images are to be recorded in the event of an alarm. You can link any number of 15-minute intervals with the recording profiles for each day of the week. Moving the mouse cursor over the table displays the time below it. This aids orientation. In addition to the normal weekdays, you can define holidays that are not in the standard weekly schedule on which recordings are to apply. This allows you to apply a schedule for Sundays to other days with dates that fall on varying weekdays.
Weekdays
Assign as many time periods (in 15-minute intervals) as needed for any day of the week. Move the mouse cursor over the table - the time is displayed.
1. Click the profile to be assigned in the Time periods box.
2. Click a field in the table and, while holding down the left mouse button, drag the cursor across all of the fields to be assigned to the selected profile.
3. Click the No recordings profile in the Time periods box to deselect the intervals.
4. Click Select All to select all of the intervals to be assigned to the selected profile.
5. Click Clear All to deselect all of the intervals.
6. When finished, click Set to save the settings to the device.
Holidays
You can define holidays that are not in the standard weekly schedule on which recordings are to apply. This allows you to apply a schedule for Sundays to other days with dates that fall on varying weekdays.
1. Click the Holidays tab. Any days that have already been selected will be shown in the table.
2. Click the Add button. A new window will open.
3. Select the desired date from the calendar. You can select several consecutive calendar days by holding down the mouse button. These will later be displayed as a single entry in the table.
4. Click OK to accept the selection. The window will close.
5. Assign the individual holidays to the recording profiles, as described above.
Deleting Holidays
You can delete holidays you have defined yourself at any time.
1. Click the Delete button. A new window will open.
2. Click the date you wish to delete.
3. Click OK. The item will be deleted from the table and the window will close.
4. The process must be repeated for deleting additional days.
Time periods
You can change the names of the recording profiles.
1. Click a profile and then the Rename button.
2. Enter your chosen name and then click the Rename button again.
Activating the Recording
After completing configuration you must activate the recording scheduler and start the recording. Once recording is underway, the Recording Profiles and Recording Scheduler pages are deactivated and the configuration cannot be modified. You can stop the recording activity at any time and modify the settings.
1. Click the Start button to activate the recording scheduler.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 45
MIC IP ultra 7100i │ MIC IP starlight 7100i Recording | en 45
2. Click the Stop button to deactivate the recording scheduler. Running recordings are interrupted and the configuration can be changed.
Recording status
The graphic indicates the recording activity of the camera. You will see an animated graphic while recording is taking place.

6.6 Recording Status

Details of the recording status are displayed here for information. These settings cannot be changed.

6.7 Recording Statistics

Recording
Identifies the current recording profile (1 or 2).
Zoom
Identifies the current zoom factor of the camera (1x, 2x, 4x, or 8x).
Averaging period
Select the appropriate averaging period as a means of stabilizing the long term bit rate.

6.8 Image Posting

JPEG
Image size
Select the size of the JPEG images that are to be sent from the camera. JPEG resolution corresponds to the highest setting from the two data streams.
File name
Select how file names are created for the individual images that are transmitted. – Overwrite: The same file name is always used and any existing file will be overwritten by
the current file.
Increment: A number from 000 to 255 is added to the file name and automatically
incremented by 1. When it reaches 255, it starts again from 000.
Date/time suffix: The date and time are automatically added to the file name. When
setting this parameter, ensure that the date and time of the device are always set correctly. For eample, the file snap011005_114530.jpg was stored on October 1, 2005 at
11.45 and 30 seconds.
VCA overlays
To include VCA overlays in the email, select this check box.
Posting interval
Enter the interval in seconds at which the images are sent to an FTP server. Enter zero for no images to be sent. The following field may or may not appear, depending on your camera:
Target
Select the target account for JPEG posting.
Face detection
When face recognition is available, selected images of the face can be sent to a target account.
Target
Select the target account for JPEG posting.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 46
46 en | Alarm MIC IP ultra 7100i │ MIC IP starlight 7100i
!

7 Alarm

7.1 Alarm Connections

You can select how the camera responds to an alarm. In the event of an alarm, the unit can automatically connect to a pre-defined IP address. You can enter up to ten IP addresses to which the camera will connect in sequence in the event of an alarm, until a connection is made.
Connect on alarm
Select On so that the camera automatically connects to a predefined IP address in the event of an alarm. By setting Follows input 1*, the unit maintains the connection that has been automatically established for as long as an alarm exists on alarm input 1.
Notice!
In the default setting, Stream 2 is transmitted for alarm connections. Consider this when assigning the profile (see Encoder Profile).
Number of destination IP address
Specify the numbers of the IP addresses to be contacted in the event of an alarm. The unit contacts the remote stations one after the other in the numbered sequence until a connection is made.
Destination IP address
For each number, enter the corresponding IP address for the desired remote station.
Destination password
If the remote station is password protected, enter the password here. Only ten passwords can be defined here. Define a general password if more than ten connections are required. The unit connects to all remote stations protected by the same general password. To define a general password:
1. Select 10 in the Number of destination IP address list box.
2. Enter 0.0.0.0 in the Destination IP address field.
3. Enter the password in the Destination password field.
4. Set the user password of all the remote stations to be accessed using this password. Setting destination 10 to the IP-address 0.0.0.0 overrides its function as the tenth address to try.
Video transmission
If the unit is operated behind a firewall, select TCP(HTTP port) as the transfer protocol. For use in a local network, select UDP.
Caution!
Please note that in some circumstances, a larger bandwidth must be available on the network for additional video images in the event of an alarm, in case Multicast operation is not possible. To enable Multicast operation, select the UDP option for the Video transmission parameter here and on Network Access.
Stream
Select the number of the stream from the drop-down list.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 47
MIC IP ultra 7100i │ MIC IP starlight 7100i Alarm | en 47
Remote port
Depending on the network configuration, select a browser port here. The ports for HTTPS connections will be available only if the On option is selected in the SSL encryption parameter.
Video output
If you know which unit is being used as the receiver, you can select the analog video output to which the signal should be switched. If the destination unit is unknown, it is advisable to select the First available option. In this case, the image is placed on the first free video output. This is an output on which there is no signal. The connected monitor only displays images when an alarm is triggered. If you select a particular video output and a split image is set for this output on the receiver, you can also select from Decoder the decoder in the receiver that is to be used to display the alarm image.
Notice!
Refer to the destination unit documentation concerning image display options and available video outputs.
Decoder
If a split image is set for the selected video output, select a decoder to display the alarm image. The decoder selected determines the position in the split image.
SSL encryption
SSL encryption protects data used for establishing a connection, such as the password. By selecting On, only encrypted ports are available for the Remote port parameter. SSL encryption must be activated and configured on both sides of a connection. The appropriate certificates must also have been uploaded. (Certificates can be uploaded on the Maintenance page.) Configure and activate encryption for media data (such as video, metadata or audio when available) on the Encryption page (encryption is only available if the appropriate license is installed).
Auto-connect
Select the On option to automatically re-establish a connection to one of the previously specified IP addresses after each reboot, after a connection breakdown or after a network failure.
Notice!
In the default setting, Stream 2 is transmitted for automatic connections. Bear this fact in mind when assigning the profile (see Encoder Profile).
The following field may or may not appear, depending on your camera:
Audio
Select On to activate audio alarms. The following field may or may not appear, depending on your camera:
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 48
48 en | Alarm MIC IP ultra 7100i │ MIC IP starlight 7100i

7.2 Video Content Analysis (VCA)

Note: This section of the manual provides an overview of the fields and the options for each
field on the page VCA. This section is not a complete tutorial of setting up VCA. For more information, refer to the separate manual Video Content Analysis (VCA), available on the product page for Intelligent Video Analytics. Access the product page on the online product catalog from http://www.boschsecurity.com/corporate/product-catalog/index.html.
VCA configuration
Select one of the profiles here to activate it or edit it. You can rename the profile.
1. To rename the file, click the icon to the right of the list field and enter the new profile name in the field.
2. Click the icon again. The new profile name is saved.
Do not use any special characters, for example &, in the name. Special characters are not supported by the system's internal management. If you select the option Silent VCA, then the system creates metadata to facilitate searches of recordings but no alarm is triggered. You cannot change any parameters for this configuration. If you want to turn off VCA, then select Off. If necessary, click the button Default to return all settings to their default values. A dialog box appears with the message, “Configuration of the video content analysis (VCA) will be reset to factory defaults. The changes will be lost. Click 'OK' to continue.” Click OK to acknowledge the message, or click Cancel.
Scenario
Scenarios are applications with pre-defined settings that are adapted to specific use cases. All relevant settings, from tasks to metadata, are set automatically by the system. The following scenarios are available: – Intrusion (one field) – Intrusion (two fields) – People counting – Traffic incidents – Traffic wrong way
Notice!
A camera calibration is required for all scenarios. Using the scenarios will reset the VCA configuration to the scenario defaults. All values (Metadata Generation and Tasks) can be edited after activating the scenario defaults. Delete tasks that do not fit your use cases.
Analysis type
Select the appropriate option for VideoContentAnalysis: MOTION+, Intelligent Video Analytics, or Intelligent Video Analytics Flow. Note: When you select another analysis type, a dialog box appears with the message, “Changing the analysis type resets motion and tamper parameters.” Click OK to acknowledge the message (and to switch analysis types), or click Cancel.
Alarm status
The alarm status is displayed here for information purposes. This means you can check the effects of your settings immediately.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 49
MIC IP ultra 7100i │ MIC IP starlight 7100i Alarm | en 49
Tamper detection
Detect tampering of cameras and video cables by means of various options. Run a series of tests at different times of the day and night to ensure that the video sensor is operating as intended.
Sensitivity and Trigger delay [s] can only be changed if Reference check is selected.
Reference check
Save a reference image that can be continuously compared with the current video image. If the current video image in the marked areas differs from the reference image, an alarm is triggered. This detects tampering that would otherwise not be detected, for example, if the camera is turned.
1. Click Reference to save the currently visible video image as a reference.
2. Click Add mask and select the areas in the reference image that are to be ignored. Click Set to apply.
3. Check the box Reference check to activate the on-going check. The stored reference image is displayed in black and white below the current video image.
4. Select the Disappearing edges or Appearing edges option to specify the reference check once again.
Trigger delay [s]
Set delayed alarm triggering here. The alarm is only triggered after a set time interval in seconds has elapsed and then only if the triggering condition still exists. If the original condition has been restored before this time interval elapses, the alarm is not triggered. This avoids false alarms triggered by short-term changes, for example, cleaning activities in the direct field of vision of the camera.
Global change
You can set how large the global change in the video image must be for an alarm to be triggered. This setting is independent of the sensor fields selected under Select Area. Set a high value if fewer sensor fields need to change to trigger an alarm. With a low value, it is necessary for changes to occur simultaneously in a large number of sensor fields to trigger an alarm. This option allows you to detect, independently of motion alarms, manipulation of the orientation or location of a camera resulting from turning the camera mount bracket, for instance.
Global change
Activate this function if the global change, as set with the Global change slide control, should trigger an alarm.

7.3 Audio Alarm

The camera can create alarms on the basis of audio signals. You can configure signal strengths and frequency ranges in such a way that false alarms, for example due to machine noise or background noise, are avoided.
Notice!
First set up normal audio transmission before you configure the audio alarm here (see Audio).
Audio alarm
Select On if you want the device to generate audio alarms.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 50
50 en | Alarm MIC IP ultra 7100i │ MIC IP starlight 7100i
!
Do not use any special characters, for example &, in the name. Special characters are not supported by the system's internal management.
Signal Ranges
You can exclude particular signal ranges in order to avoid false alarms. For this reason the total signal is divided into 13 tonal ranges (mel scale). Check or uncheck the boxes below the graphic to include or exclude individual ranges.
Threshold
Set up the threshold on the basis of the signal visible in the graphic. You can set the threshold using the slide control or, alternately, you can move the white line directly in the graphic using the mouse.
Sensitivity
You can use this setting to adapt the sensitivity to the sound environment. You can effectively suppress individual signal peaks. A high value represents a high level of sensitivity.

7.4 Alarm E-Mail

As an alternative to automatic connecting, alarm states can also be documented by e-mail. In this way it is possible to notify a recipient who does not have a video receiver. In this case, the camera automatically sends an e-mail to a previously defined e-mail address.
Send alarm e-mail Select On if you want the unit to automatically send an alarm e-mail in the event of an alarm.
Mail server IP address
Enter the IP address of a mail server that operates on the SMTP standard (Simple Mail Transfer Protocol). Outgoing e-mails are sent to the mail server via the address you entered. Otherwise leave the box blank (0.0.0.0).
SMTP port
Select the appropriate SMTP port.
SMTP user name
Enter a registered user name for the chosen mailserver here.
SMTP password
Enter the required password for the registered user name here.
Format
You can select the data format of the alarm message. – Standard (with JPEG) E-mail with attached JPEG image file. – SMS E-mail in SMS format to an e-mail-to-SMS gateway (for example to send an alarm by
cellphone) without an image attachment.
Caution!
When a cellphone is used as the receiver, make sure to activate the e-mail or SMS function, depending on the format, so that these messages can be received. You can obtain information on operating your cellphone from your cellphone provider.
Image size Select the appropriate image size: Small, Medium, Large, 720p, 1080p, Best possible.
Attach JPEG from camera
Click the checkbox to specify that JPEG images are sent from the camera. An enabled video input is indicated by a check mark.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 51
MIC IP ultra 7100i │ MIC IP starlight 7100i Alarm | en 51
VCA overlays
Select the VCA overlays check box, to place the outline of the object that triggered an alarm into the camera image sent as snapshot via e-mail.
Destination address
Enter the e-mail address for alarm e-mails here. The maximum address length is 49 characters.
Sender address
Enter a unique name for the e-mail sender, for example the location of the device. This will make it easier to identify the origin of the e-mail. Note: The name must include at least two character groups separated by a blank (for example, Parking Garage) in order for the system to generate an email from that name, as in “From Parking Garage”. Text with only one group of characters (for example, Lobby) will not generate an email.
Test e-mail
You can test the e-mail function by clicking the Send Now button. An alarm e-mail is immediately created and sent.

7.5 Alarm Task Editor

Editing scripts on this page overwrites all settings and entries on the other alarm pages. This procedure cannot be reversed. To edit this page, you should have programming knowledge and be familiar with the information in the Alarm Task Script Language document and the English language.
As an alternative to the alarm settings on the various alarm pages, enter the desired alarm functions in script form here. This will overwrite all settings and entries on the other alarm pages.
1. Click Examples under the Alarm Task Editor field to see some script examples. A new window opens.
2. Enter new scripts in the Alarm Task Editor field or change existing scripts in line with your requirements.
3. When finished, click Set to transmit the scripts to the device. If the transfer was successful, the message Script successfully parsed. is displayed over the text field. If it was not successful, an error message is displayed with further information.

7.6 Alarm Rules

An alarm rule can define which input(s) activate which output(s). Basically, an alarm rule allows you to customize the camera to respond automatically to different alarm inputs. To configure an alarm rule, specify one input from a physical connection, from a motion detection trigger, or from a connection to the camera’s LIVE page. The physical input connection can be activated by dry contact devices such as pressure pads, door contacts, and similar devices. Next, specify up to two (2) rule outputs, or the camera’s response to the input. Outputs include a physical alarm output, an AUX command, or a preposition scene. Select the appropriate option in the field Input (a physical alarm connection): – Video analytics/MOTION+: If you select this option, then an alarm will begin when IVA or
motion detection is activated.
Connection: If you select this option, then an alarm will begin when an attempt is made
to access the camera’s IP address.
Time: If you select this option, then an input field appears to the right. In this field, enter
the time for the activation of the alarm in hours and minutes. (The default value is 00:00.)
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 52
52 en | Alarm MIC IP ultra 7100i │ MIC IP starlight 7100i
Time range: If you select this option, then two input fields appear to the right. In these
fields, enter the time range for the activation of the alarm in hours and minutes. (The
default values are 00:00 and 00:00.) Select one of the following output commands for both Output 1 and Output 2 settings: Note: Not all options are available for all cameras. – None: no defined command. – AUX on: defines a standard or custom keyboard ON command. – AUX off: defines a standard or custom keyboard OFF command. – Pre-position: defines a pre-position from shot 1-256. (Note: This option is not available
for the input Time range.) – Alarm output
Note for MIC IP cameras only: Alarm output is available only when the field Application variant in the
page 19
is set to [camera name] - IO“ (for a camera connected to MIC-ALM-WAS-24)
Application variant,
Click the checkbox Enabled to activate the alarm. Click Set to save. The camera’s system activates the alarm rules.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 53
MIC IP ultra 7100i │ MIC IP starlight 7100i Network | en 53

8 Network

8.1 Network Services

This page shows an overview of all available network services. Use the checkbox to activate or deactivate a network service. Click on the settings symbol next to the network service to go to the settings page for this network service.

8.2 Network Access

The settings on this page are used to integrate the camera into an existing network.
Automatic IPv4 assignment
If the network has a DHCP server for the dynamic assignment of IP addresses, select On to accept automatically the DHCP-assigned IP address. For certain applications, the DHCP server must support the fixed assignment between IP address and MAC address, and must be set up appropriately so that, once an IP address is assigned, it is retained each time the system is rebooted.
Ethernet
The Ethernet options are defined in this section.
IP V4 address
IP address
Enter the desired IP address for the camera in this field. The IP address must be valid for the network.
Subnet mask
Enter the appropriate subnet mask for the selected IP address here.
Gateway address
If you want the unit to establish a connection to a remote location in a different subnet, enter the IP address of the gateway here. Otherwise leave the box blank (0.0.0.0).
IP V6 address
IP address
Enter the desired IP address for the camera in this field. The IP address must be valid for the network. A typical IPv6 address may resemble the following example: 2001:db8: :52:1:1 Consult the network administrator for valid IPv6 address construction.
Prefix length
A typical IPv6 node address consists of a prefix and an interface identifier (total 128 bits). The prefix is the part of the address where the bits have fixed values or are the bits that define a subnet.
Gateway address
If you want the unit to establish a connection to a remote location in a different subnet, enter the IP address of the gateway here. Otherwise leave the box blank (0.0.0.0).
DNS server address 1 / DNS server address 2
The camera is easier to access if the unit is listed on a DNS server. If you wish, for example, to establish an Internet connection to the camera, it is sufficient to enter the name given to the unit on the DNS server as a URL in the browser. Enter the IP address of the DNS server here. Servers are supported for secure and dynamic DNS.
Video transmission
If the unit is operated behind a firewall, select TCP(HTTP port) as the transfer protocol. For use in a local network, select UDP.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 54
54 en | Network MIC IP ultra 7100i │ MIC IP starlight 7100i
Notice!
Multicast operation is only possible with the UDP protocol. The TCP protocol does not support multicast connections. The MTU value in UDP mode is 1,514 bytes.
UDP encryption
Enable this option to encrypt the User Datagram Protocol (UDP) connection. UDP with encryption can also be used in multicast networks.
HTTP browser port
Select a different HTTP browser port from the list if required. The default HTTP port is 80. If you want to allow only secure connections via HTTPS, you must deactivate the HTTP port. In this case, select Off.
HTTPS browser port
If you wish to allow browser access on the network via a secure connection, select an HTTPS browser port from the list if necessary. The default HTTPS port is 443. Select the Off option to deactivate HTTPS ports; only unsecured connections will now be possible. The camera uses the TLS 1.0 encryption protocol. You may have to activate this protocol via your browser configuration. You must also activate the protocol for the Java applications (via the Java control panel in the Windows control panel).
Notice!
If you want to allow only secure connections with SSL encryption, you must select the Off option for each of the parameters HTTP browser port, RCP+ port1756 and Telnet support. This deactivates all unsecured connections. Connections will then only be possible via the HTTPS port.
You can activate and configure encryption of the media data (video and metadata) on the
Encryption page (see Encryption).
Minimum TLS version
Select the version for minimum Transport Layer Security (TLS).
Allow HTTP basic authentication
Select On if you want to allow HTTP basic authentication. This is a less secure authentication option where passwords are transmitted in clear text. This option should only be used if the network and system are otherwise secured.
HSTS
Select this option to use the web security policy HTTP Strict Transport Security (HSTS) to provide secure connections.
RCP+ port 1756
To exchange connection data, you can activate the unsecured RCP+ port1756. If you want connection data to be transmitted only when encrypted, select the Off option to deactivate the port.
Discovery port
Enter the number of the port that you want to discover. To deactivate the port, enter 0.
Interface mode ETH
Select the Ethernet link type for the ETH interface. Options are: – Auto
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 55
MIC IP ultra 7100i │ MIC IP starlight 7100i Network | en 55
10 Mbps HD (half duplex) – 10 Mbps FD (full duplex) – 100 Mbps HD (half duplex) – 100 Mbps FD (full duplex)
Network MSS (Byte)
You can set the maximum segment size for the IP packet's user data. This gives you the option to adjust the size of the data packets to the network environment and to optimize data transmission. Please comply with the MTU value of 1,514bytes in UDP mode.
iSCSI MSS (Byte)
You can specify a higher MSS value for a connection to the iSCSI system than for the other data traffic via the network. The potential value depends on the network structure. A higher value is only useful if the iSCSI system is located in the same subnet as the camera.
Network MTU [Byte]
Specify a maximum value in bytes for the package size (including IP header) to optimize data transmission.

8.3 DynDNS

Enable DynDNS
DynDNS.org is a DNS hosting service that stores IP addresses in a database ready for use. It allows you to select the camera via the Internet using a host name, without having to know the current IP address of the unit. You can enable this service here. To do this, you must have an account with DynDNS.org and you must have registered the required host name for the unit on that site.
Notice!
Information about the service, registration process and available host names can be found at DynDNS.org.
Provider
The value in this field defaults to dyndns.org. Select another option as necessary.
Host name
Enter the host name registered on DynDNS.org for the camera here.
User name
Enter the user name you registered at DynDNS.org here.
Password
Enter the password you registered at DynDNS.org here.
Force registration now
You can force the registration by transferring the IP address to the DynDNS server. Entries that change frequently are not provided in the Domain Name System. It is a good idea to force the registration when you are setting up the device for the first time. Only use this function when necessary and no more than once a day, to avoid the possibility of being blocked by the service provider. To transfer the IP address of the camera, click the Register button.
Status
The status of the DynDNS function is displayed here for information purposes. You cannot change any of these settings.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 56
56 en | Network MIC IP ultra 7100i │ MIC IP starlight 7100i

8.4 Advanced

The settings on this page are used to implement advanced settings for the network.
Cloud-based services
Operation
The operation mode determines how the camera communicates with the Bosch Remote Portal. – Select On to poll the server constantly. – Select Off to block polling.
Cloud state
This field identifies any cloud-based services with which the camera communicates. – If you have registered the device on a cloud-based service such as Bosch Remote Portal,
then this field identifies this fact (“Registered on Bosch Remote Portal”).
Note: The button (Connect to Bosch Remote Portal) to connect to the device with that
service is active. – If you have not registered the device, then the message, “Not running. (Automatic IP
assignment not active)“ appears.
Note: The button (Connect to Bosch Remote Portal) to connect to the device with that
service is not active.
RTSP port
If necessary, select a different port for the exchange of the Real Time Streaming Protocol (RTSP) data from the list. The standard RTSP port is 554. Select Off to deactivate the RTSP function.
Authentication
If a RADIUS server is employed in the network for managing access rights, authentication must be activated here to allow communication with the unit. The RADIUS server must also contain the corresponding data. To configure the unit, you must connect the camera directly to a computer using a network cable. This is because communication via the network is not enabled until the Identity and
Password parameters have been set and successfully authenticated.
Identity
Enter the name that the RADIUS server is to use for identifying the camera.
Password
Enter the password that is stored in the RADIUS server.
NTCIP
Specifies a set of rules and protocols for organizing, describing and exchanging transportation management information between transportation management applications and transportation equipment such that they interoperate with each other. Select a port for NTCIP as well as the Address from the appropriate drop-down lists.
Note: The NTCIP section appears only for cameras with an NTCIP license.
TCP metadata input
TCP port
The device can receive data from an external TCP sender, for example an ATM or POS device, and store it as metadata. Select the port for TCP communication. Select Off to deactivate the TCP metadata function.
Sender IP address
Enter the IP address of the TCP metadata sender here.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 57
MIC IP ultra 7100i │ MIC IP starlight 7100i Network | en 57
Syslog
Server IP address
Enter the appropriate IP address of the server.
Server port (0 = Off)
Enter the number of the server port.
Protocol Select the appropriate protocol: UDP, TCP, or TLS.
LLDP power configuration
Requested for camera
The value in this field identifies the number of watts requested for the camera.
Additional Power
Enter the number of additional watts that you want the camera to use.
Requested total The value in this field is the total number of watts from the fields Requested for camera and Additional Power.
Allocated power
The value in this field is the number of watts of allocated power to the camera.

8.5 Network Management

8.5.1 UPnP

Select On to activate UPnP communication. Select Off to deactivate it. When the Universal Plug-and-Play (UPnP) function is activated, the unit responds to requests from the network and is automatically registered on the requesting computers as a new network device. This function should not be used in large installations due to the large number of registration notifications.
Note:
To use the UPnP function on a Windows computer, both the Universal Plug-and-Play Device Host and the SSDP Discovery Service must be activated.

8.5.2 Quality of Service

The priority of the different data channels can be set by defining the DiffServ Code Point (DSCP). Enter a number between 0 and 252 as a multiple of four. For alarm video you can set a higher priority than for regular video and you can define a Post Alarm Time over which this priority is maintained.

8.6 Multicast

The camera can enable multiple receivers to receive the video signal simultaneously. The stream is either duplicated and then distributed to multiple receivers (Multi-unicast), or it is sent as a single stream to the network, where it is simultaneously distributed to multiple receivers in a defined group (Multicast).
Multicast operation requires a multicast-enabled network that uses UDP and the Internet Group Management protocol (IGMPV2). The network must support group IP addresses. Other group management protocols are not supported. The TCP protocol does not support multicast connections.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 58
58 en | Network MIC IP ultra 7100i │ MIC IP starlight 7100i
A special IP address from 225.0.0.0 to 239.255.255.255 (classD address) must be configured for multicast operation in a multicast-enabled network. The multicast address can be the same for multiple streams, however, it is necessary to use a different port in each case.
The settings must be made individually for each stream. Enter a dedicated multicast address and port for each stream. Switch between the streams by clicking the appropriate tabs.
Enable
Enable simultaneous data reception on receivers that need to activate the multicast function. To do this, check the box and enter the multicast address.
Multicast Address
Enter a valid multicast address to be operated in multicast mode (duplication of the data stream in the network).
With a 0.0.0.0 setting, the encoder for the stream operates in multi-unicast mode (copying of data stream in device). The camera supports multi-unicast connections for up to five simultaneously connected receivers.
Duplication of data places a heavy demand on the CPU and can lead to impairment of the image quality under certain circumstances.
Port
Enter the port address for the stream here.
Streaming
Click the checkbox to activate multicast streaming mode. An activated stream is marked with a check. (Streaming is typically not required for standard multicast operation.)
Multicast packet TTL
You can enter a value to specify how long the multicast data packets are active on the network. This value must be greater than one if multicast is to be run via a router.
IGMP version
You can define the multicast IGMP version to comply with the device. Click Set to apply the changes.

8.7 Accounts

Four separate accounts can be defined for posting and recording export.
Type
Select either FTP or Dropbox for the account type. Before using a Dropbox account ensure that the time settings of the device have been correctly synchronized.
Account name
Enter an account name to be shown as the target name.
IP address
Enter the IP address of the server on which you wish to save the JPEG images.
Login
Enter the login ID for the server.
Password
Enter the password that gives you access to the server. To verify the password, click the Check button to the right.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 59
MIC IP ultra 7100i │ MIC IP starlight 7100i Network | en 59
Path
Enter the exact path on which you wish to post the images on the server. To browse for the correct path, click the Browse button to the right.
Maximum bit rate
Enter the maximum bit rate for the JPEG images (in kbps).
Encryption
Tick the box to use a secure FTP over TLS connection.

8.8 IPv4 Filter

Use this setting to configure a filter that allows or blocks network traffic that matches a specified address or protocol.
IP Address 1 / 2
Enter the IPv4 address that you want to allow or block
Mask 1 / 2
Enter the subnet mask for the appropriate IPv4 address.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 60
60 en | Service MIC IP ultra 7100i │ MIC IP starlight 7100i
!

9 Service

9.1 Maintenance

Update server
The address of the update server appears in the address box.
1. Click Check to make a connection to this server.
2. Select the appropriate version for your camera to download the firmware from the server.
Firmware
The camera functions and parameters can be updated by uploading new firmware. To do this, the latest firmware package is transferred to the device via the network. The firmware is installed there automatically. Thus, a camera can be serviced and updated remotely without requiring a technician to make changes to the device on site. The latest firmware can be obtained from your customer service center or from the download area.
Notice!
Before starting a firmware update, make sure to select the correct upload file. Do not interrupt the firmware installation. Even changing to another page or closing the browser window leads to interruption. Uploading the wrong files or interrupting the upload can result in the device no longer being addressable, requiring it to be replaced.
Caution!
Do not remove power to the unit during a factory default or a firmware update. Wait at least two minutes for the default process to complete. If the unit appears to be "frozen" after two minutes, then reboot the unit. Refer to
Progress
The progress bar displays the progress of the firmware upload. Note: Once the progress bar reaches 100%, a reset page may appear. If this page appears, allow the reset page to complete its action.
Upload history Click Show to view the firmware upload history.
Configuration Click Browse... to navigate to the required firmware file (*.fw). Note: Ensure that the file to be loaded comes from the same unit type as the unit that you
want to configure. Click Upload to begin transferring the file to the unit. Click OK to the warning message to continue the firmware upload, or Cancel to stop the upload. Click Download to save the camera settings to a file to upload to the same camera or to a similar camera in the future.
Maintenance log
You can download an internal maintenance log from the unit to send it to Customer Service for support purposes. Click Download and select a storage location for the file.
Troubleshooting, page 72
for more details.

9.2 Licenses

This window is for the activation of additional functions by entering activation codes. An overview of installed licenses is shown. The installation code of the unit is also displayed here.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 61
MIC IP ultra 7100i │ MIC IP starlight 7100i Service | en 61

9.3 Certificates

Add a certificate/file to the file list
Click Add. In the Add certificate window choose either: – Upload certificate to select a file that is already available:
Click Browse to navigate to the required file. – Click Upload.
Generate signing request for a signing authority to create a new certificate:
Fill in all the required fields and click Generate.
Generate certificate to create a new self-signed certificate:
Fill in all the required fields and click Generate.
Delete a certificate from the file list
Click the trashcan icon to the right of the certificate. The Delete file window appears. To confirm deletion, click OK. To cancel deletion, click Cancel. Note: You can only delete certificates that you have added; you cannot delete the default certificate.

9.4 Logging

Current log level
Select the level of event for which to display log entries or to log.
Number of displayed entries
Select the number of entries to display.
Enable software sealing
Select this check box to enable software protection that prevents users from adjusting camera settings. This function also protects the camera from unauthorized access.

9.5 Diagnostics

Accesses the Built-in Self Test (BIST). The BIST displays a Pass or Fail status on the most recent homing event, not a counter. For the other items, a counter is maintained. Click the Start Self test button to display the number of times the camera: – performed a homing event. – failed to home properly. – restarted. – lost video.
Logs
This section updates automatically with the history of the camera and maintains a log of all events such as those listed below. Click the REFRESH button to reload log data.

9.6 System Overview

This window is for information only and cannot be modified. Keep this information at hand when seeking technical support. Select the text on this page with a mouse and copy it so that it can be pasted into an e-mail if required.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 62
62 en | Operation via the browser MIC IP ultra 7100i │ MIC IP starlight 7100i

10 Operation via the browser

10.1 Live page

10.1.1 Connection

Stream 1
Select this option to display stream 1 of the camera.
Stream 2
Select this option to display stream 2 of the camera.
M-JPEG
Select this option to display the M-JPEG stream of the camera.

10.1.2 PTZ

Pan and tilt controls
To tilt the camera up: Click and hold the up arrow. – To tilt the camera down: Click and hold the down arrow. – To pan the camera left: Click and hold the left arrow. – To pan the camera right: Click and hold the right arrow. – To pan and tilt the camera at the same time (variable pan/tilt): Click and drag the center
area (that resembles a point stick or a trackball on a computer keyboard) around the PTZ
control in the direction that you want to move the camera.
Zoom
Click the + button to zoom in. Click the - button to zoom out. A "snap to area" or "snap to zoom" function allows you to select a different area of the video image to which to zoom the camera. Hold the Ctrl key and use your mouse to draw a box/rectangle over the video to define the area to which to zoom. When you release the Ctrl key, the camera zooms to the defined position.
Iris
Click (Iris close) to close the iris.
Click (Iris open) to open the iris.
Focus
Click to focus near.
Click to focus far.

10.1.3 Pre-positions

The camera displays Pre-position 1 through Pre-position 6. Select the appropriate pre­position to view the video image for that pre-position/scene. In the lower left of the video image, the OSD displays the Camera number (title), the Pre-position number, and the Pre­position number stored. Below the list of pre-positions/scenes is a drop-down list showing the stored pre-positions/ scenes.
Select the appropriate pre-position (1 through 6). Click to store the pre-position.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 63
MIC IP ultra 7100i │ MIC IP starlight 7100i Operation via the browser | en 63
Note: If the pre-position is already stored, a dialog box displays the message, “Overwrite current pre-position?” Click OK to overwrite, or click Cancel to cancel the operation.
Click to display the selected pre-position in the video image.

10.1.4 AUX Control

With the tab AUX Control you can enter pre-programmed keyboard control commands. These commands are composed of a command number plus the appropriate function key (Show pre- position, Set pre-position, AUX on, or AUX off). A valid combination either issues a command to the device or displays an on-screen menu.
Show pre-position
Click this button to display a pre-position.
Set pre-position
Click this button to set a pre-position.
AUX on
Click this button to activate an AUX command.
AUX off
Click this button to deactivate an AUX command.

10.1.5 Special Functions

Scan 360°
Click this button to start a continuous 360° pan. To stop the continuous pan, click a directional control in the View Control tab.
Autopan
Click this button to pan the camera between user-defined limits.
Tour A / Tour B
Click one of these buttons to start the continuous playback of a recorded (guard) tour. A recorded tour saves all manual camera movements made during the recording, including its rate of pan, tilt and zoom speeds, and other lens setting changes. To stop a tour, click a directional control in the View Control tab.
Focus
Click this button to activate the Auto Focus One Push mode on the camera. The OSD displays the message, “Auto Focus: ONE PUSH.”
IR light
Click this button to turn on the infrared (IR) light of the illuminator accessory (if available on your camera). Click this button again to turn off the IR light.
White light
Click this button to turn on the White light of the illuminator accessory (if available on your camera). Click this button again to turn off the White light.
Custom tour
Click this button to view (in continuous playback) a custom tour that was previously configured.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 64
64 en | Operation via the browser MIC IP ultra 7100i │ MIC IP starlight 7100i

10.1.6 Recording status

The hard drive icon below the live camera image changes during an automatic recording. The icon lights up and displays a moving graphic to indicate a running recording. If no recording is taking place, a static icon is displayed.

10.1.7 Saving snapshots

Individual images from the displayed live video stream can be saved locally in JPEG format on the computer's hard drive. The storage location depends on the configuration of the camera.
Click the photo camera icon to save a single image.

10.1.8 Recording live video

Video sequences from the displayed live video stream can be saved locally on the computer's hard drive. The sequences are recorded at the resolution specified in the encoder configuration. The storage location depends on the configuration of the camera.
1. Click the recording icon to record video sequences.
Saving begins immediately. The red dot on the icon indicates that a recording is in
progress.
2. Click the recording icon again to stop recording.

10.1.9 Full-screen display

Click the full-screen icon to view the selected stream in full-screen mode; press Esc on the keyboard to return to the normal viewing window.

10.1.10 Audio communication

Audio can be sent and received via the Live page if the unit and the computer support audio.
1. Press and hold the F12 key on the keyboard to send an audio signal to the unit.
2. Release the key to stop sending audio. All connected users receive audio signals sent from the unit but only the user who first pressed the F12 key can send audio signals; others must wait for the first user to release the key.

10.1.11 Storage, CPU and network status

When you access the unit with a browser, the icons in the list that follows are at the top right corner of the window:
CPU load icon – Network load icon The information from the icons can help with solving problems with the unit or with fine­tuning the unit.
Hover over the CPU load icon to see the CPU load. If the CPU load is too high, change the VCA settings. Hover over the Network load icon to see the network load. If the network load is too high, change the encoder profile to reduce the bitrate.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 65
MIC IP ultra 7100i │ MIC IP starlight 7100i Operation via the browser | en 65

10.1.12 Status icons

Various overlays in the video image provide important status information. The overlays provide the following information:
Decoding error
The frame might show artifacts due to decoding errors.
Alarm flag
Indicates that an alarm has occurred.
Communication error
A communication error, such as a connection failure to the storage medium, a protocol violation or a timeout, is indicated by this icon.
Gap
Indicates a gap in the recorded video.
Watermark valid The watermark set on the media item is valid. The color of the check mark changes according to the video authentication method that has been selected.
Watermark invalid
Indicates that the watermark is not valid.
Motion alarm
Indicates that a motion alarm has occurred.
Storage discovery
Indicates that recorded video is being retrieved.

10.1.13 Date and Time

Date/Time (unlabeled)
The unlabeled date and time ticker appears above the row of icons (including
) that is below the lower-left corner of the live video image.

10.1.14 Video Security App

Start Video Security app
To start the Video Security app, click .
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 66
66 en | Operation via the browser MIC IP ultra 7100i │ MIC IP starlight 7100i

10.2 Playback

10.2.1 Selecting the recording stream

On the left side of the browser, expand the Connection group if necessary. To view a recording stream:
1. Click the Recording drop-down arrow to see the options.
2. Select recording stream 1 or 2.

10.2.2 Searching for recorded video

On the left side of the browser, expand the Search group if necessary.
1. To limit the search to a particular time range, enter the date and times for the start and stop points.
2. Select an option from the drop-down box to define a search parameter.
3. Click Search.
4. The results are shown.
5. Click a result to play it back.
6. Click Back to define a new search.

10.2.3 Exporting recorded video

On the left side of the browser, expand the Export group if necessary.
1. Select a track in the track list or in the search results.
2. The start and stop date and time are filled-in for the selected track. If required, change the times.
3. In the Time lapse drop-down box, select the original or a condensed speed.
4. In the Location drop-down box, select a target.
5. Click Export to save the video track.
Note: The target server address is set on the Network / Accounts page.

10.2.4 Controlling playback

The time bar below the video image allows quick orientation. The time interval associated with the sequence is displayed in the bar in gray. Arrows indicate the position of the image currently being played back within the sequence. The time bar offers various options for navigation in and between sequences. – If required, click in the bar at the point in time at which the playback should begin. – Change the time interval displayed by clicking the plus or minus icons or use the mouse
scroll wheel. The display can span a range from six months to one minute.
Click the alarm jump buttons to go from one alarm event to the next or to the previous
one. Red bars indicate the points in time where alarms were triggered.
Controls
Control playback by means of the buttons below the video image. The buttons have the following functions: – Start/Pause playback – Select the playback (forward or backward) speed using the speed regulator – Step forward or backward frame-by-frame when paused (small arrows)

10.3 Dashboard

The Dashboard page shows information on 4 topics: – Device status Recording status
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 67
MIC IP ultra 7100i │ MIC IP starlight 7100i Operation via the browser | en 67
Connection Status Services
You can also download a .JSON file with information about the device:
1. At the bottom of the page, locate the Export button
2. Click the Export button
3. Select a location in your hard drive to store the file
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 68
68 en | Using your MIC Camera MIC IP ultra 7100i │ MIC IP starlight 7100i

11 Using your MIC Camera

11.1 Recommended Use of Your MIC Camera

Bosch recommends that you consider the following in order to optimize the life of your Bosch camera.
1. Guard Tours and Preset Tours
With your camera, you can cover a full 360° view using continuous Guard Tours or Preset Tours. Depending on the type of camera tour selected, your camera might be either in continuous motion (pan, tilt, or both) or moving between selected preset positions.
Continuous Guard Tours
Guard Tours are a very effective way of monitoring the entire scene; however, if not configured properly, continuous Guard Tours can reduce the service life of your camera considerably. Continuous Guard Tours should be used in applications where the tours are required to run for a fixed duration during the day (not more than twelve hours/day). Additionally, for best results, the continuous guard tour should be used in scenes with sufficient illumination levels (50 lux or better), should be at least 60 seconds in duration, and should have a smooth pan/ tilt path (without erratic stops and starts), with the lens set at a wide angle (infinity focus). The tour should also include at least 10° of tilt movement.
Note: Tour B is now intended for use with the 'IVA while moving' functions.
Preset Tours
For scenarios that require the camera to be in continuous motion for most of the day, Bosch recommends that you set the camera in Preset Tour mode, moving between a desired set of presets. For best results, always ensure that each preset has a dwell time of at least 5 seconds.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 69
MIC IP ultra 7100i │ MIC IP starlight 7100i Using your MIC Camera | en 69

11.2 Uploading a User Logo

Customers have the option to upload custom logos that display on the web browser of the device. All user logo images must comply with the following requirements: – The file format must be a bitmap (.bmp). – Height and width must not exceed 128 pixels. – Color depth must be 8 bit (256 color bitmap).
Upload the Logo File
1. If necessary, open the browser. Click Configuration.
2. Click General. Select Display Stamping.
3. Select the field Camera name stamping. Select the position of the logo: Bottom, Top, or Custom. Note: If you select Custom, then additional fields (Position (XY)) appear where you can specify the exact position of the logo. In the fields Position (XY), enter the values for the desired position (0 - 255).
4. Click Logo Browse to open a file-search dialog. Select the image file (.bmp).
5. Click Upload to transfer the file to the camera. The message “Upload successful” should appear. The new logo, if applicable, replaces the previous one.
6. Select the field Logo position. Select the position of the logo on either side of the camera name: Left, Right, or Logo only. (The default value is Off.)
7. Click Set to save.
Set Logo Transparency (Optional)
1. Click the check box Transparent background.
2. Click Set to save.
3. Note that the color of the entire first line of the logo is the color that will be changed to transparent in the remainder of the logo. For example, if the first line is white, then all of the identical white colors of the logo image will become transparent.
Change the Camera Title
1. Click General. Select Identification.
2. Delete all of the text in the field Camera name.
3. Rename the camera if desired.
4. Click Set to save.

11.3 Two-line and Three-line Camera Titles

There are two options to display camera titles, but these should not be used together. Choose one of the following modes. – Mode 1: Azimuth/Elevation/Compass/Zoom Options – Mode 2: Camera Title combined with Compass
Mode 1: Azimuth/Elevation/Compass/Zoom Options
Select one of the following options: – Display Azimuth/Elevation and ZOOM value (Optical/Digital) at the bottom of the screen.
Use the command AUX ON-95-ENTER.
Display Azimuth/Elevation/Compass at the bottom of the screen. Use the command AUX
ON-96-ENTER.
Mode 2: Camera Title combined with Compass
Select one of the following options. Users can toggle between the two options. – Display two (2) lines of text at the top of the video. Use the command AUX ON-75-ENTER.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 70
70 en | Using your MIC Camera MIC IP ultra 7100i │ MIC IP starlight 7100i
Display three (3) lines of text at the top of the video. Use the command AUX ON-76-
ENTER.
About Fonts for Camera Titles
The default font style is white text with a clear background. The font size cannot be
changed.
Using the command AUX ON-77-ENTER, users can change the font color manually when
the camera is in Day Mode. Toggle the text colors in the following sequence: White­>Yellow->Violet->Red->Cyan->Green->Blue->White.
Using the command AUX OFF-77-ENTER, users can set the color again to the default
white. – The font color changes automatically to white when the camera enters Night Mode. – When the camera returns to Day Mode, the camera will use the selected font color
automatically.
Available Character Set
Characters permitted: – A-Z (upper case only) – 0-9 – Miscellaneous characters such as - [SPACE]! " $ & ' , . / : ? Characters not permitted: – Lower case characters (a-z) – Underscores (_) – Save these settings so that, in case of a power failure, the system will recover and then
restore the user values.
Two-line Camera Title
At the top of the video, there are two lines of text. Line 1 displays the first 20 characters of the Camera Name/ID. Users can edit this text to enter a highway name, camera location, etc. Line 2 displays the text, “LOOKING: X” or “LOOKING: XX” (without quotation marks), where “X” or “XX” is the compass direction. This line cannot be edited by the end user. – LOOKING will always appear in English and will be at a fixed location on the OSD. – The X or XX designates the compass direction that updates automatically as the camera
pans. A identifies “North,” “South,” “East,” or West.” AA identifies “Northeast,”
“Northwest,” “Southeast,” or “Southwest.”
Three-line Camera Title
Lines 1 and 2 display the first 20 characters of both lines of the Camera Name/ID. Users can edit both of these lines to enter a highway name, camera location, etc. Line 3 displays the text, “LOOKING: X” or “LOOKING: XX” (without quotation marks), where “X” or “XX” is the compass direction. This line cannot be edited by the end user. – LOOKING will always appear in English and will be at a fixed location on the OSD. – The X or XX designates the compass direction that updates automatically as the camera
pans. A identifies “North,” “South,” “East,” or West.” AA identifies “Northeast,”
“Northwest,” “Southeast,” or “Southwest.”
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 71
MIC IP ultra 7100i │ MIC IP starlight 7100i Using your MIC Camera | en 71

11.4 Azimuth, Elevation, and Compass Directions

The camera can display the following data in the lower-right corner of the image display: – Azimuth - The pan angle from zero to 359 degrees in one-degree increments. An azimuth
of zero degrees corresponds to North.
Elevation - The tilt position from zero (horizon) to -90 degrees (camera pointing straight
down) in one-degree increments.
Compass - The cardinal or intercardinal (N, NE, E, SE, S, SW, W, NW) heading in which
the camera is pointing. The camera allows users to display only the azimuth/elevation readings or only the compass reading, or both readings at the same time. The camera displays the azimuth/ elevation readings and the compass heading in a format such as “180 / -45 S,” where: – 180 is the Azimuth or the pan location in degrees. – -45 is the Elevation or the tilt location in degrees. – S is the compass direction (cardinal or intercardinal). The camera uses the azimuth to determine the compass direction. The following table shows the azimuth range and its corresponding compass heading:
Azimuth Range Compass Direction
21° to 65° NE (Northeast) 66° to 110° E (East)
111° to 155° SE (Southeast) 156° to 200° S (South)
201° to 245° SW (Southwest) 246° to 290° W (West)
291° to 335° NW (Northwest) 336° to 20° N (North)
21° to 65° NE (Northeast) 66° to 110° E (East)
111° to 155° SE (Southeast) 156° to 200° S (South)
201° to 245° SW (Southwest) 246° to 290° W (West)
291° to 335° NW (Northwest) 336° to 20° N (North)
The camera uses the Azimuth Zero point, usually set to magnetic North, as the zero degree pan position and as the North compass heading. The camera then displays the azimuth reading and the compass heading based on the number of degrees from the Azimuth Zero point.
Notice!
Bosch recommends that only the installer calibrate the Azimuth Zero point. A recalibration to the Azimuth Zero point may cause inaccurate compass headings.
Set the Azimuth Zero point:
1. Determine the North compass heading, then move the camera to that position.
2. Use the command AUX OFF-90-ENTER to turn off the command lock (if active).
3. Use the command AUX ON-94-ENTER to set the Azimuth Zero point.
Display/hide the azimuth/elevation reading:
Use the command AUX ON-95-ENTER to display the azimuth/elevation reading. – Use the command AUX OFF-95-ENTER to hide the azimuth/elevation reading.
Display/hide the compass heading:
Use the command AUX ON-96-ENTER to display the compass heading. – Use the command AUX OFF-96-ENTER to hide the compass heading.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 72
72 en | Troubleshooting MIC IP ultra 7100i │ MIC IP starlight 7100i

12 Troubleshooting

Table of Troubleshooting Issues
The table below identifies issues that could occur with the camera, and how to resolve them. Note: Refer to the Error Codes section of the manual for descriptions of the error codes that appear on the OSD. The section also lists recommended actions to resolve the error codes.
Problem Questions to Ask/Actions to Resolve the Problem
No camera control. – Ensure that the LAN cable has good connection and
is secured. – Refresh the browser and ensure that video is updated. – Cycle the camera's power off and on.
Video is rolling, noisy, or distorted. – Check the integrity of all connectors and splices of
the Ethernet cable. If O.K., then: – Contact Bosch Technical Support.
Camera moves when attempting to move other cameras.
No Network Connection. – Check all network connections.
Camera does not operate at all, or does not operate as expected, after being subjected to extreme low temperatures (below -40 ° (-40 °F)).
Camera reboots frequently or intermittently
– Check that the camera’s IP address is properly set. If camera’s IP address is not set, then: – Use Configuration Manager to confirm that two cameras do not have the same IP address. If they do, change the address of one of the cameras.
– Ensure that the maximum distance between any two Ethernet connections is 100 m (328 ft) or less. If O.K., then: – If you are behind a firewall, ensure that the Video Transmission mode is set to UDP.
- Allow the camera to warm up. The camera requires a 60-minute warm-up prior to PTZ operations.
- If camera does not operate after this warm-up period, then reset the camera. In the URL line of your web browser, type “/reset” at the end of the IP address of the camera.
Your camera has an improper network connection. Test your camera with another power supply. Check the Bosch website for a software update that might address the issue.
Nothing appears on the screen. Are the power cord and line connection between the
camera and monitor made properly?
The image on the screen is dim. Is the lens dirty? If so, clean the lens with a soft,
clean cloth.
The contrast on the screen is too weak.
2020-08 | 1.3 | User Manual Bosch Security Systems
Adjust the contrast feature of the monitor. Is the camera exposed to strong light? If so, change the camera position.
Page 73
MIC IP ultra 7100i │ MIC IP starlight 7100i Troubleshooting | en 73
The image on the screen flickers. Does the camera face directly into the sun or
fluorescent lighting? If so, reposition camera.
The image on the screen is distorted. Is the power frequency set properly in sync? If the
power frequency is not set correctly, the line lock synchronization mode cannot be used. Set the synchronization mode to INT. (NTSC Model power frequency in LL mode: 60 Hz.)
No video. – Check that the mains power to the power supply is
on. – For IP-enabled cameras: Check to see if you have a web page. If you do, then try cycling the camera’s power off and on. If you do not, then you may have the wrong IP address. Use Configuration Manager to identify the correct IP address. If O.K., then: – Check that there is 24 V output from the transformer. If O.K., then: – Check the integrity of all wires and mating connectors to the camera.
Picture is dark. – Check that the Gain Control is set to High.
If O.K., then: – Check that the Auto Iris Level is set to the appropriate level. If O.K., then: – Check that the maximum Ethernet cable distance has not been exceeded. If O.K., then: – Restore all camera settings.
Background is too bright to see
Turn on backlight compensation.
subject.
“High Shock Event” appears in English in the middle of the OSD until the camera is reset.
The camera experienced a high shock event. – Check the integrity of the mechanical parts and
the screws (especially on the yoke arms).
If there is obvious and severe damage, stop using
the camera and contact your Bosch Service Center for assistance.
If no damage is evident, complete one of the
following steps: a) Cycle the power on the camera. b) Send command AUX OFF 65 to remove the OSD message.
If IVA is configured on your camera, the OSD
message may interfere with IVA operation.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 74
74 en | Troubleshooting MIC IP ultra 7100i │ MIC IP starlight 7100i
Configuration or video management software identifies the unit as
The model ID may be corrupt. Complete the steps in the section Rebooting the unit.
“Videojet Generic”.
Support
Access our support services at https://www.boschsecurity.com/xc/en/support/.
Bosch Security and Safety Systems offers support in these areas: – Apps & Tools Building Information Modeling Commissioning Warranty Troubleshooting Repair & Exchange Product Security
Bosch Building Technologies Academy Visit the Bosch Building Technologies Academy website and have access to training courses, video tutorials and documents: https://www.boschsecurity.com/xc/en/support/training/
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 75
MIC IP ultra 7100i │ MIC IP starlight 7100i Status Codes | en 75

13 Status Codes

For certain conditions, MIC cameras will display status codes on the video image. The table below identifies the status codes, their descriptions, and the recommended action to resolve the condition. Most status codes appear on the OSD until you acknowledge them. The codes identified with asterisks (**) appear for approximately 10 seconds, then disappear automatically. To clear the status code in the OSD, send the appropriate acknowledge command. If necessary, refer to the operation instructions in the Video Management System software for issuing acknowledge commands, or to the appropriate section in the User Manual for your MIC camera for details on issuing the “AUX OFF 65” command.
Status Code
2 Capacity of external PoE device is
3 Capacity of external PoE device is
4 Capacity of the external PoE device
5 When operating using redundant
Description Recommended action
insufficient to support operation of the camera's window defroster. Note: MIC IP fusion 9000i only.
insufficient to support operation of the camera's internal heater.
is insufficient to support operation of the camera's window defroster. Note: MIC IP fusion 9000i only.
power sources, the camerais detecting insufficient voltage being provided by the external High PoE power source.
(to be completed by a qualified Service Technician)
An incorrect type of PoE (such as one based on IEEE 802.3af) with insufficient power output may be connected to the camera.*
An incorrect type of PoE+ or PoE++ (such as one based on IEEE 802.3af or IEEE 802.3at) with insufficient power output may be connected to the camera.*
An incorrect type of PoE+ or PoE++ (such as one based on IEEE 802.3af or IEEE 802.3at) with insufficient power output may be connected to the camera.*
1. Verify that the High PoE power source (midspan or switch) can provide 95 W of output power.
2. Verify that the network cable is not longer than 100 m maximum.
3. If using the 95W High PoE Midspan (NPD-9501A), verify that both LEDs are green. If not, refer to the “Troubleshooting” section of the installation manual of the midspan.
6 When operating using redundant
power sources, the camera is detecting insufficient voltage being provided by the external 24 VAC power source.
7 Camera may be operating in an
environment where ambient temperature is below the specification of the camera.
Bosch Security Systems User Manual 2020-08 | 1.3 |
1. Verify that the 24 VAC power source can provide at least 4.0 A to the camera.
2. Verify that the wire gage of the power cable is sufficient for the distance between the power source and the camera and that the voltage getting to the user cable of the camera is between 21 VAC and 30 VAC.
1. Verify that the ambient temperature is not below -40 °C (-40 °F).
Page 76
76 en | Status Codes MIC IP ultra 7100i │ MIC IP starlight 7100i
Status
Description Recommended action
Code
8 Camera may be operating in an
environment where ambient temperature is above specification of the camera.
9 Camera has been subjected to high
shock. Mechanical damage to the camera may exist.
(to be completed by a qualified Service Technician)
2. Review the diagnostic log of the camera (accessible from the Service menu) for errors related to the operation of the internal heaters. Note: Motorized zoom and focus functions of the visible camera lens will be disabled until the camera operates within the specified temperature range.
1. Verify that the ambient temperature is not above +65 °C (+149 °F).
2. Review the diagnostic log of the camera (accessible from the Service menu) for errors related to the operation of the internal fan.
3. Add the optional sunshield accessory to reduce internal heating caused by sun loading.
1. Verify the integrity of the mechanical parts such as the arms and the pan body.
2. Verify the integrity/tightness of the external fasteners. Tighten where necessary.
3. If obvious damage is present, stop using the camera and contact the nearest Bosch Security Systems Service Center.
4. If no damage is evident, power the camera off and then on, and then evaluate operational performance. If the camera does not operate as expected, contact the nearest Bosch Security Systems Service Center.
10 Camera is detecting high humidity
level inside housing. The integrity of the housing seal may be compromised.
1. Inspect the window for any cracks or obvious damage around the edge of the window.
2. Verify the integrity/tightness of the external fasteners. Tighten where necessary.
3. Verify the integrity of the mechanical seals around the tilt head, pan body, and arm joints.
4. If damage to the seals is obvious, contact the nearest Bosch Security Systems Service Center.
5. If no obvious damage is found, power the camera off and then on. If the status code reappears, contact the nearest Bosch Security Systems Service Center.
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 77
MIC IP ultra 7100i │ MIC IP starlight 7100i Status Codes | en 77
Status
Description Recommended action
Code
11 Wiper operation has been halted
because of an obstruction.
12 Left and Right Pan Limits have been
set too close to each other.
(to be completed by a qualified Service Technician)
1. Remove any obvious materials that are obstructing operation of the wiper.
2. If the obstruction is from ice buildup, review the diagnostic log of the camera (accessible from the Service menu) for errors related to operation of the internal heaters (and the window defrosters, for MIC IP fusion 9000i). If possible, tilt the camera so that the front faceplate is pointed straight up. (In this position, heat generated by the camera will help to melt ice buildup from its front faceplate area.)
3. If the obstruction is from extreme ice buildup, temporarily avoid operating the wiper until internal heaters, combined with a rise in ambient temperature, melt the ice buildup.
Re-configure one camera stop limit or the other to increase the distance between limit stops to at least 10° apart.
13** Autofocus has been turned off
because of excessive focus activity.
14** Washer operation was attempted
without washer pre-position being stored.
15 Attempt was made to move to a pre-
position that is mapped to an alternate function, so it is no longer associated with a location.
16** Motorized zoom function is
programmed to operate at a high usage level in the Playback Tour. This high rate of usage could result in premature wear of the zoom motor.
1. If practical, increase lighting in the scene so that the focus function stops “hunting.”
2. Use focus in manual mode or One-Push mode.
Configure the washer pre-position. If necessary, refer to the subchapter “Using the Wiper/Washer (Bosch AUX/Pre-position Commands)” in the User Manual for details on configuring washer functions.
1. Select/configure a different pre-position number for the desired location.
2. Re-configure the pre-position assignment so that this number is no longer associated with an alternate function. Refer to the subchapter “Pre-position mapping” in the User Manual for details on re-mapping pre­positions.
Re-configure the camera to decrease the zoom activity to less than 30% during recording.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 78
78 en | Status Codes MIC IP ultra 7100i │ MIC IP starlight 7100i
Status
Description Recommended action
Code
17 Motor operation has been halted
due to an obstruction.
18** When operating using redundant
power sources, the camera has detected a loss of power from the external High PoE power source.
(to be completed by a qualified Service Technician)
1. Remove any obvious materials that are obstructing operation of the camera pan/tilt function.
2. If the obstruction is from ice buildup, review the diagnostic log of the camera (accessible from the Service menu) for errors related to the operation of the internal heaters (and the window defrosters, for MIC IP fusion 9000i). If the log notes heater or defroster failure, contact the nearest Bosch Security Systems Service Center.
3. If operation is obstructed because of excessive ice buildup, temporarily avoid operating the pan/tilt functions of the camera until internal heaters, combined with a rise in ambient temperature, melt the ice buildup.
1. Verify the operating status of the external High PoE power source.
2. Verify the integrity of the electrical connections between the power source and the camera.
19** When operating using redundant
power sources, the camera has detected a loss of power from the external 24 VAC power source.
1. Verify the operating status of the external 24 VAC power source.
2. Verify the integrity of the electrical connections between the power source and the camera.
20 Camera is configured to use the
“Hard Pan Limits” (HPL) feature, and it has been powered-up with pan position in the forbidden zone.
Temporarily remove one of the hard pan limits (as described in
34
), pan the camera out of the forbidden zone, and then restore the hard pan limit. Reboot the camera by powering the camera off and then on, or by clicking the button Reboot in the camera’s web browser (Configuration > Camera > Installer Menu >Reboot device). Note: If pan movement is blocked only in one direction, but possible in the other direction (as when the camera is near the HPL), then no status code appears.
The Hard Pan Limits feature is for MIC cameras only. Washer and wiper apply to MIC cameras only.
PTZ Settings, page
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 79
MIC IP ultra 7100i │ MIC IP starlight 7100i Status Codes | en 79
!
21 Illuminator error: IR Reboot the camera by powering the camera
off and then on, or by clicking the button Reboot in the camera’s web browser (Configuration > Camera > Installer Menu >Reboot device). If this action does not resolve the problem, contact the nearest Bosch Security Systems Service Center. The Service Center may request information from the diagnostics log of the camera (accessible from the Service menu).
23 An internal error has occurred.
(The optical video screen becomes blue for 1 or 2 seconds during the camera’s recovery procedure.)
Caution!
If you choose not to use a switch or midspan with the appropriate Power Sourcing Equipment (PSE) chip, then the camera will not recognize the PoE as compliant, and the camera firmware may disable some or all functionality.
If this problem begins to occur on a regular basis:
1. Verify that the power source to the camera is not experiencing brown-out conditions.
2. Verify that the camera’s earth ground connection is attached per earlier instructions. If these actions do not resolve this problem, contact the nearest Bosch Security Systems Service Center.
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 80
80 en | AUX Commands MIC IP ultra 7100i │ MIC IP starlight 7100i

14 AUX Commands

AUX Function Command Description
1 On/Off Auto Pan without limits
(Continuous)
2 On/Off Auto Pan between limits
7 On/Off Run Custom Pre-Position Tour
8 On/Off Run Pre-Position Tour
18 On/Off AutoPivot Enable
20 On/Off Backlight Compensation (BLC)
24 On/Off Video Stabilization
40 On/Off Restore camera settings [to
factory defaults]
43 On/Off Auto Gain Control (AGC)
50 On/Off Playback A, continuous
51 On/Off Playback A, single
52 On/Off Playback B, continuous
53 On/Off Playback B, single
57 On/Off Night mode IR Filter In/Out
60 On/Off On-Screen Display (OSD)
61 On/Off Preset & Sector Titles Camera
Block Overlay VDSK not required
65 Off Alarm Acknowledge Acknowledges alarm events/rules or
deactivates physical outputs.
67 On/Off IR Focus Correction
78 On/Off Intelligent Tracking
80 On/Off Digital Zoom lock
86 On/Off Sector Blanking
87 On/Off Privacy Masking
88 On/Off Proportional Speed
94 On/- Recalibrate Azimuth Compass
95 On/Off Azimuth/Elevation Display
96 On/Off Compass Points Display
100 On/Off Record Tour A
101 On/Off Record Tour B
102 On/Off Wiper On/Off (Continuous)
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 81
MIC IP ultra 7100i │ MIC IP starlight 7100i AUX Commands | en 81
AUX Function Command Description
103 On/Off Wiper On/Off (Intermittent)
104 On/Off Wiper On/Off (One shot)
105 On/Off Wash/Wipe On/Off
121 On/Off Left Hard Pan Limit
122 On/Off Right Hard Pan Limit
123 On/Off Clear Hard Pan Limits
606 On/Off Power Mode
700 On/Off Proportional speed control
adjustment
Aux On, entered repeatedly, cycles through increasing speeds Super Slow, Slow, Medium, and Fast. Aux Off, decreases speeds through the same settings.
804 On/Off Mask Calibration Procedure
908 Increase Privacy Mask Size while
moving
1-256 Set/- Pre-position Programming
1-256 -/Shot Pre-position Recall
The following commands are specific to MIC7000 models, including MIC IP starlight 7000i.
AUX Function Command Description
54 On/Off IR mode AUX ON sets IR to Auto.
AUX OFF sets IR to OFF. Available for only.
57 On/Off Night mode IR Filter In/Out
68 On/Off White light illumination
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 82
82 en | Support MIC IP ultra 7100i │ MIC IP starlight 7100i

15 Support

Support
Access our support services at https://www.boschsecurity.com/xc/en/support/.
Bosch Security and Safety Systems offers support in these areas: – Apps & Tools Building Information Modeling Commissioning Warranty Troubleshooting Repair & Exchange Product Security
Bosch Building Technologies Academy Visit the Bosch Building Technologies Academy website and have access to training courses, video tutorials and documents: https://www.boschsecurity.com/xc/en/support/training/
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 83
MIC IP ultra 7100i │ MIC IP starlight 7100i Support | 83
Bosch Security Systems User Manual 2020-08 | 1.3 |
Page 84
84 | Support MIC IP ultra 7100i │ MIC IP starlight 7100i
2020-08 | 1.3 | User Manual Bosch Security Systems
Page 85
Page 86
Bosch Security Systems B.V.
Torenallee 49 5617 BA Eindhoven Netherlands
www.boschsecurity.com
© Bosch Security Systems B.V., 2020