Bosch WGES24-75WR, WGES24-75WW, WGEC24-75WW, WGEC24-75WR Specsheet

Bosch WGES24-75WR, WGES24-75WW, WGEC24-75WW, WGEC24-75WR Specsheet

Fire Alarm Systems | WGE Weatherproof Strobes and Horn Strobes

WGE Weatherproof Strobes and Horn

Strobes

www.boschsecurity.com

The Gentex WGE family of weatherproof strobes and horn strobes offer dependable visible and audible alarms. The horns have a synchronizable (using the AVSM Synchronization Module) chime and whoop tones. You can select high or low volume and choose a 2400 Hz (remote signaling) tone or a low frequency (1500 Hz to 3000 Hz) mechanical sounding tone where doors could prevent hearing the other tone. They are easily field changeable from temporal Code 3 to a continuous tone. They are shipped from the factory on the temporal lower frequency mode, and come standard with a rugged die cast metal mounting plate. The strobes have a low operating current and a minimum flash rate of 1 Hz regardless of the input voltage.

These devices are equipped with the SuperSlide feature to test supervision and the Instant Voltage Verification feature for measuring voltage drop draw. The GOE Outdoor Enclosure is included with each unit. The unit and GOE enclosure must be used together to meet the UL outdoor listing.

uWide voltage range, 16 to 33 VDC or FWR

u75 cd strobe meets ADA 4.28.3 requirements

uListed for outdoor use when used with the GOE outdoor enclosure

uJumper selection for high or low frequency and for temporal Code 3 or continuous tone patterns

uSeparate horn and strobe functions; silences horn while strobes remain flashing

Certifications and approvals

Gentex Corporation holds these Listings and Approvals:

Region

Certification

 

 

 

USA

UL

ULSZ: Audible-signal Appliances

 

 

(ANSI/UL 464), ULSZ7: Audible-signal

 

 

Appliances Certified for Canada (CAN/

 

 

ULC-S525), UVAV: Visual-signal Appli-

 

 

ances for Fire-protective Signaling Sys-

 

 

tems (ANSI/UL 1638), and UEES7: Visu-

 

 

al-signal Appliances Certified for Canada

 

 

[CAN/ULC-S526 (1987)]

 

CSFM

see our website

 

 

 

Installation/configuration notes

Compatible Products

The following products are compatible with these strobes and horn strobes:

Control Panels:

Active1: FPA-1000 family and FPD-7024 family

2 | WGE Weatherproof Strobes and Horn Strobes

Legacy1: D10024A, D9412, D8024, D70242, and D70223

Synchronization Modules:

AVSM R and AVSM W

1 For synchronization, use the AVSM R or AVSM W Synchronization Modules with these control panels.

2 When used with a D7039 Multiplex Expansion Module, the D7024 becomes an addressable fire alarm control panel (FACP).

3 The D7022 must be set for 24 VDC operation and requires the AVSM R or AVSM W Synchronization Modules for synchronization.

Mounting Considerations

For an outdoor application or a severe environment (NEMA 3R) application, the WGES Strobes and WGEC Horn Strobes must be surface mounted on a flat wall in a GOE Outdoor Enclosure. The enclosure is supplied. Knockout holes are sized for 3/4 inch conduit and matching connector. Use a watertight conduit fitting.

Wiring

Notice

Do not use these units in coded or pulsed signaling circuits.

The input terminals accept wires with diameters between 18 AWG and 12 AWG (ISO 0.75 mm2 and 4 mm2).

Parts included

Quant. Component

1Strobe or horn strobe with finish plate

1Die cast mounting plate

1GOE outdoor enclosure

1Plastic test card

1Hardware pack

1Literature pack

Technical specifications

Electrical

Strobe Current (maximum)

180 mA RMS; 245 mA FWR

 

 

Voltage (Input):

 

 

 

 

nominal

24 VDC or FWR

 

 

 

range

16 VDC or FWR to 33 VDC or FWR

 

 

Environmental

 

 

 

Temperature (Operating):

 

 

 

 

Indoor

+32°F to +120°F (0°C to +49°C)

 

 

 

Outdoor

-31°F to +150°F (-35°C to +66°C)

 

 

 

Mechanical

Candela Rating

75 cd

 

 

Dimensions (HxWxD):

 

 

 

 

without GOE

5 in. x 4.5 in. x 2.5 in. (12.7 cm x

 

enclosure

11.4 cm x 6.4 cm)

 

 

 

with GOE enclosure

5.75 in. x 4.75 in. x 4.2 in. (14.6 cm x

 

 

12.1 cm x 10.6 cm)

 

 

 

Alarm Ratings

Notice

The sound output for the temporal (Code 3) tone is rated lower because the time the horn is off is averaged into the sound output rating. When the horn is producing a tone in the temporal mode its sound pressure is the same as the continuous mode.

Horn (Continuous, 2400 Hz)

Audible Device Current

 

28 mA RMS; 48 mA FWR

(maximum)

 

 

 

 

 

Sound output at 10 ft (3 m) at

 

High output: 86 dBA; Low output:

24 VDC

 

78 dBA

 

 

 

 

 

Horn (Continuous, Mechanical)

 

Audible Device Current

 

25 mA RMS; 44 mA FWR

(maximum)

 

 

 

 

 

Sound output at 10 ft (3 m) at

 

High output: 84 dBA; Low output:

24 VDC

 

76 dBA

 

 

 

 

 

Horn (Temporal Code 3, 2400 Hz)

 

Audible Device Current

 

28 mA RMS; 48 mA FWR

(maximum)

 

 

 

 

 

Sound output at 10 ft (3 m) at

 

High output: 83 dBA; Low output:

24 VDC

 

75 dBA

 

 

 

 

 

Horn (Temporal Code 3, Mechanical)

 

Audible Device Current

 

25 mA RMS; 44 mA FWR

(maximum)

 

 

 

 

 

Sound output at 10 ft (3 m) at

 

High output: 81 dBA; Low output:

24 VDC

 

73 dBA*

 

 

 

* If you operate the horn in this mode at this voltage, it does not meet the UL reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high output setting for public mode application.

Loading...