Page 1
CDI series
Model SM
Residential Geothermal Heat Pump
Overview and Certifi cations
Engineering
Submittal
Sheet
Standard Features and Field Installed Accessories
Standard Features
White Pre-Painted Sheet Metal Cabinets
— Appliance White for a Clean - Durable Look
— Door Handles - for Easy Removal for Service
— LCD Display - for Easy View of Unit Operation
High Efficiency
— Up to 4.7 COP @ PL GLHP
— Up to 4.0 COP @ FL GLHP
— Up to 32.0 EER @ PL GLHP
— Up to 22.0 EER @ FL GLHP
Electronically Commutated Motors
— Constant CFM Variable Speed High Effi ciency ECM
Closed Cell (Fiber Free) Insulation
— Improved Indoor Air Quality
— Floating Base Pan
1 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
BTC 760108306 H | 12.2018
Reliability - Durability - Serviceability
— Evaporator Coil - Tin-plated copper tubing hair
pins with high-tech polymer coated aluminum fi ns
(DuoGuard™)*
— Alert Communicating Electronic Circuit Board
Electronic Circuit Board
— Low Pressure Switch Protection
— High Pressure Switch Protection
— Alarm Output
— Condensate overflow protection
— Anti-Short Cycling
— Low Pressure Bypass at Start Up
— Random Start of Unit
— Brown Out Protection
— Evaporator Freeze Protection
— Water Coil/Coaxial Coil/Condenser Freeze
Protection
— Connections for a communicating thermostat
and unit external status LCD for easy view of unit
operation
* Available only for Vertical models. For Horizontal models, tin-plated
copper tubing hair pins only is available.
Bosch Thermotechnology Corp.
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 2
SM Series -
Residential Geothermal Heat Pumps
Standard Features and Field Installed Accessories continued..
Engineering Submittal Sheet
Standard Warranty
— 10 Year All Parts Limited Warranty
— 10 Year Labor Limited Warranty
Domestic Hot Water Heat Recovery Package (Desuperheater):
— Utilizes the compressor's superheated discharge gas
to preheat domestic hot water, reducing the amount of
electricity or fossil fuels otherwise used for hot water.
Cupro-nickel Coils:
— Cupro-Nickel coils are recommended for applications
where the water is of lower quality. Only coils are
cupro-nickel. All fi ttings and straight lengths of pipe will
be copper.
Field Installed Accessories
Thermostats:
— Bosch thermostats are fully customized to meet
your individual needs. Bosch offers communicating
thermostats that can display alert messages without
having to go to the unit.
— Passive dehumidification can be achieved via ECM fan
controls paired with optional Bosch thermostat with
humidity control
Internally Mounted Electric Heat Kits:
— A field installed option for back up heat. Available
in 5, 10, 15, or 20 kW depending on the size of the
geothermal heat pump.
Stainless Steel Hose Kits:
— Available in various lengths and diameters depending
on the need for your application.
SmartStart Assist Kit:
— An option which provides a means of reducing inrush
currents at compressor startup. Light flickering is
eliminated, and a smooth start is achieved.
2 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
BTC 760108306 H | 12.2018
Horizontal Discharge Air Conversion Kit:
— The horizontal conversion kit allows end blow to
straight through conversion of discharge air, as the
straight through configuration for horizontal is no
longer available.
Pump/Valve Relay Kit:
— This relay is used to energize a supply pump or
solenoid valve when there is a call for compressor
operation. This relay can be used to switch either
high or low voltage power.
Externally Mounted Duct Heater Kits
Flow Center Kits
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 3
SM Series -
Residential Geothermal Heat Pumps
Model Nomenclature
SM 48 - 1 VT C - F L T A T X - X H G X X X X X D 7 X X X X 4 X X X X S B
1-2 3-5 6 7 8-9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
MODEL:
SM
NOMINAL
CAPACITY:
024
036
048
060
070
ELECTRICAL
CONFIGURATION:
- 208-230/60/1
1
CABINET CONFIGURATION:
- Horizontal
HZ
VT
- Vertical
COAX OPTIONS:
- Copper
C
- Cupro-nickel*
N
*Only coils are cupro-nickel.
WATER CONNECTIONS:
F
- Front
RETURN AIR CONFIGURATION:
- Left
L
- Right
R
DISCHARGE AIR LOCATION:
- Top (VT only)
T
- End (HZ only)E
FAN/MOTOR OPTION:
- Constant CFM ECM Motor
A
AIR COIL:
- DuoGuard(
D
- Tin-Plated (HZ Only)
T
REVISION LEVEL:
- Rev A (HZ Only)
AA
- Rev B (VT Only)
B
) / SS Drain Pan (VT Only)
™
Engineering Submittal Sheet
CODE STRING LEVEL:
- Revision
A
CHANNEL:
B
- Bosch
STANDARD/SPECIAL:
- Standard
S
AGENCY OPTIONS:
- ETL (UL 1995)
X
NOT USED:
- None
X
DRIVE SPEED (MC ONLY):
- N/A
X
MOTOR HP/QTY (BELT DRIVE ONLY)
- N/A
X
AIR FILTRATION:
- MERV8 - 2" w/ 4-Sided
4
Filter Rack (VT only)
5 - MERV13 - 2" w/ 4-Sided
Filter Rack (HZ only)
NOT USED:
- None
X
ECONOMIZER:
- None
X
WATER FLOW CONTROL OPTIONS:
X
- None
CONTROLS:
- Standard
X
TRANSFORMER:
- 75VA
7
REFRIGERATION:
- Heat Recovery Package
D
ELECTRIC HEAT:
X
- None
CABINET CONSTRUCTION:
H
- Painted Steel / 1/2" Closed Cell
Foam (HZ only)
- Painted Steel / 1/2" Closed Cell
M
Foam, Extra Quiet (to include
compressor blanket as standard)
(VT only)
3 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
BTC 760108306 H | 12.2018
ELECTRICAL OPTIONS:
- As default for non-used electrical
X
codes
APPLICATION:
- EXTENDED RANGE (Geothermal)
G
Bosch Thermotechnology Corp.
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 4
SM Series -
Engineering Submittal Sheet
Residential Geothermal Heat Pumps
Physical Data
Description Unit
Compressor Type (Qty 1) — Scroll Scroll Scroll Scroll Scroll
Refrigeration Charge VT Oz. 45 73 75 98 94
Refrigeration Charge HZ only Oz. 58 85 77 100 114
Max Water Working Pressure PSIG/kPa 450/3100 450/3100 450/3100 450/3100 450/3100
Max Water Working Pressure w/ Swivel
fi ttings
Fan Motor and Blower
Fan Motor Type/Speeds —
Fan Motor (HP) HP 0.33 0.75 0.75 1.00 1.00
Blower Wheel Size VT Inch (Dia. x W) 9 X 7 11 X 11 11 X 11 11 X 11 11 X 11
Blower Wheel Size HZ only Inch (Dia. x W) 10 X 8 11 X 9 11 X 9 11 X 11 11 X 11
Water Connection Size
FPT VT
(Factory brazed non-swivel type)
FPT HZ only (Factory brazed swivel) Inch 1.0 1.0 1.0 1.0 1.0
Field installed Swivel fi ttings
(Shipped loose with unit)
Coaxial Coil Volume VT Gal 0.43 0.73 0.64 1.08 1.08
Coaxial Coil Volume HZ only(gal) Gal 0.33 1.18 0.62 1.07 1.12
Vertical Cabinet
Air Coil Dimensions (H x W) Inch (H x W) 24 x 21 32x28.3 32x28.3 36x28.3 36x28.3
Air Coil Fin Density Fins/Inch 14 14 14 14 14
Nominal size of Standard Filter - 2" MERV
8 (L x H)
Weight - Operating (lbs)* lbs 220 360 340 375 375
Weight - Shipping (lbs)* lbs 300 460 450 500 500
Horizontal Cabinet
Air Coil Dimensions (H x W) Inch (H x W) 18 X 31.5 20 X 42 20 X 42 20 X 49 20 X 49
Air Coil Fin Density Fins/Inch 14 14 14 14 14
Nominal size of Standard Filter - 2"
MERV13 (L x H)
Weight - Operating (lbs)* lbs 260 375 355 430 460
Weight - Shipping (lbs)* lbs
* This data refl ects standard unit weights only. Additional options may cause differences in listed weights.
PSIG/kPa 125/861 125/861 125/861 125/861 125/861
Inch 3/4 1.0 1.0 1.0 1.0
Inch 1.0 1.0 1.0 1.0 1.0
Inch (L x H) 24 X 24 16 X 30 (2) 16 X 30 (2) 20 X 30 (2) 20 X 30 (2)
Inch (L x H) 18 X 18 (2) 20 X 24 (2) 20 X 24 (2) 18 X 20 (3) 18 X 20 (3)
SM024 SM036 SM048 SM060 SM070
ECM Const Air
Flow
360 495 470 550 580
ECM Const Air
Flow
Value
ECM Const Air
Flow
ECM Const Air
Flow
ECM Const Air
Flow
4 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
BTC 760108306 H | 12.2018
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 5
SM Series -
Engineering Submittal Sheet
Residential Geothermal Heat Pumps
ASHRAE/AHRI/ISO 13256-1. English (I-P) Units
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Models
Orientation
VT 6.0 Full 26200 16.2 30300 5.6
VT 6.0 Part 19600 18.3 22800 6.5 22400 32.1 18200 5.2 21300 27.8 15500 4.4
HZ 6.0 Full 25500 17.4 29200 5.6 29000 26.5 23500 4.9 26600 19.9 18000 3.8
SM024
HZ 6.0 Part 18500 18.9 21200 6.5
VT 10.0 Full 39300 18.6 46300 6.2
VT 10.0 Part 28900 20.4 33100 7.2 32800 35.0 26000 5.5 31600 30.0 22000 4.7
HZ 9.0 Full 39000 18.2 42800 5.1 43300 26.8 35900 4.6 40800 20.7 28400 4.0
SM036
HZ 9.0 Part 29000 20.8 31000 5.6
VT 12.0 Full 50500 16.7 60300 5.6
VT 12.0 Part 37100 18.3 44200 6.2 42600 32.2 35500 5.0 40100 26.8 30600 4.5
HZ 12.0 Full 49200 15.7 56100 5.1 55300 25.2 46300 4.6 51300 19.3 36900 3.9
SM048
HZ 12.0 Part 36700 18.0 40900 5.7
VT 15.0 Full 62500 15.4 78300 5.4
VT 15.0 Part 46400 17.7 57600 6.0 53500 30.6 45900 4.9 51100 25.2 39900 4.4
HZ 15.0 Full 63800 16.1 73300 4.9 70200 24.4 60300 4.6 65100 18.9 45500 3.9
SM060
HZ 15.0 Part 47500 18.7 53600 5.8
VT 18.0 Full 69700 14.3 88900 5.0
VT 18.0 Part 52900 16.4 67700 5.5 61200 26.9 53800 4.6 58100 23.3 46100 4.1
HZ 18.0 Full 71600 14.8 84000 5.0 78700 21.2 70000 4.5 73700 16.9 55300 3.8
SM070
HZ 18.0 Part 55200 16.7 64900 5.4
Load
Fluid Flow Rate
Cooling 86 deg.F Heating 68 deg.F Cooling 59 deg.F Heating 50 deg.F
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
COP
Capacity
Btuh
29400 24.9 24700 4.9 26900 18.9 18700 4.1
21700 30.4 16700 5.1 21000 28.1 14400 4.2
44300 27.1 36700 5.4 40200 21.0 28200 4.4
32600 34.9 25200 4.7 31900 29.2 22400 4.1
56900 25.2 49200 4.9 51800 19.3 38200 4.2
42000 32.2 33700 4.8 39900 26.8 29800 4.4
71600 24.0 62400 4.7 63900 18.6 48600 4.0
53300 31.2 44300 4.8 51600 26.5 37200 4.1
78900 22.1 72600 4.4 71500 17.3 56000 3.8
60800 27.9 52900 4.7 60300 23.4 46900 4.3
EER
Btuh/W
Capacity
Btuh
COP
Cooling
Full Load 77 °F
Part Load 68 °F
Capacity
Btuh
EER
Btuh/W
Heating
Full Load 32 °F
Part Load 41 °F
Capacity
Btuh
COP
ENERGY STAR Rated Products
Electrical Data (ECM Blower Motor)
Models Voltage Code
SM024 1 208-230/1/60 197/253 1 11.7 58.3 2.8 17.4 25
SM036 1 208-230/1/60 197/253 1 15.3 83.0 6.8 25.9 40
SM048 1 208-230/1/60 197/253 1 21.2 104.0 6.8 33.3 50
SM060 1 208-230/1/60 197/253 1 27.1 152.9 9.1 43.0 70
SM070 1 208-230/1/60 197/253 1 29.7 179.2 9.1 46.2 70
Voltage/Phase/
Hz
Voltage Min/Max
QTY RLA LRA FLA
Compressor
Total Unit Variable Speed Constant CFM
High Effi ciency Motor
Min Circuit
Amps
Values shown above do not include electric heat
option.
Units with Factory Installed Electric Heat option
will have two separate data plates for each
electrical circuit.
5 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
BTC 760108306 H | 12.2018
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Max Fuse/
HACR
Page 6
SM Series -
Engineering Submittal Sheet
Residential Geothermal Heat Pumps
1st Data plate for units with EH fi eld installed kit - compressor power connection
Models Voltage Code
SM024 1 208-230/1/60 197/253 1 11.7 58.3 14.6 25
SM036 1 208-230/1/60 197/253 1 15.3 83.0 19.1 30
SM048 1 208-230/1/60 197/253 1 21.2 104.0 26.5 45
SM060 1 208-230/1/60 197/253 1 27.1 152.9 33.9 60
SM070 1 208-230/1/60 197/253 1 29.7 179.2 37.1 60
2nd data plate for units with EH fi eld installed kit - Constant Airfl ow ECM motor
Model
SM024 4.8 1 4,800 3,600 20.0 17.3 2.8 - 28.5 25.1 30 30
SM036 4.8 1 4,800 3,600 20.0 17.3 6.8 - 33.5 30.1 35 35
SM036 9.6 1 9,600 7,200 40.0 34.6 6.8 - 58.5 51.8 60 60
SM048 4.8 1 4,800 3,600 20.0 17.3 6.8 - 33.5 30.1 35 35
SM048 9.6 1 9,600 7,200 40.0 34.6 6.8 - 58.5 51.8 60 60
SM048 14.4 2 14,400 10,800 60 51.9 6.8
SM060 4.8 1 4,800 3,600 20.0 17.3 9.1 - 36.4 33.0 40 35
SM060 9.6 1 9,600 7,200 40.0 34.6 9.1 - 61.4 54.6 70 60
SM060 14.4 2 14,400 10,800 60 51.9 9.1
SM060 19.2 2 19,200 14,000 80 69.2 9.1
SM070 4.8 1 4,800 3,600 20.0 17.3 9.1 - 36.4 33.0 40 35
SM070 9.6 1 9,600 7,200 40.0 34.6 9.1 - 61.4 54.6 70 60
SM070 14.4 2 14,400 10,800 60 51.9 9.1
SM070 19.2 2 19,200 14,000 80 69.2 9.1
Electric
Heater Rated kWStage
Voltage/Phase/HzVoltage Min/
Heater
Watts
240V 208V 240V 208V Fuses 240V 208V 240V 208V
Max
QTY RLA LRA
Heater
Amps
Motor
FLA (A)
Circuit MCA MOCP
F1/F2
F3/F4
F1/F2
F3/F4
F1/F2
F3/F4
F1/F2
F3/F4
F1/F2
F3/F4
Compressor
Min Circuit
Amps
83.5 73.4 90 80
86.4 76.3 90 80
111.4 97.9 125 100
86.4 76.3 90 80
111.4 97.9 125 100
Max Fuse/
HACR
6 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
BTC 760108306 H | 12.2018
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 7
SM Series -
Residential Geothermal Heat Pumps
SM-VT Dimensions and Connections
Engineering Submittal Sheet
)
(FIELD INSTALLED
ELECTRIC HEAT KIT
7 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
BTC 760108306 H | 12.2018
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 8
SM Series -
Residential Geothermal Heat Pumps
SM-HZ End Blow Dimensions and Connections
Engineering Submittal Sheet
8 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
BTC 760108306 H | 12.2018
(FIELD INSTALLED
ELECTRIC HEAT KIT)
Bosch Thermotechnology Corp.
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 9
SM Series -
Residential Geothermal Heat Pumps
SM-HZ Straight Through Dimensions and Connections
Engineering Submittal Sheet
9 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
BTC 760108306 H | 12.2018
(FIELD INSTALLED
ELECTRIC HEAT KIT)
Bosch Thermotechnology Corp.
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 10
SM Series -
Residential Geothermal Heat Pumps
SM-HZ Hanging Bracket Dimensions and Connections
Engineering Submittal Sheet
10 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
BTC 760108306 H | 12.2018
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 11
SM Series -
Residential Geothermal Heat Pumps
SM024 Full Load Cooling Performance Data - 900 SCFM 254 Fan Watts .6 ESP
Entering
Water Temp °F
Water fl ow
GPM
3.0 2.4 1.0
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT
°F DB / °F WB
Operation Not Recom-
mended
Total
KBtu/hr.
Latent
Capacity Kbtu/hr
Engineering Submittal Sheet
SHR Power kW EER
20
30
40
50
60
70
80
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
11 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
5.0 5.9 2.5
7.0 10.6 4.5
3.0 2.4 1.0
5.0 5.7 2.4
7.0 10.4 4.4
3.0 2.1 0.9
5.0 5.4 2.3
7.0 10.1 4.3
3.0 2.1 0.9
5.0 5.4 2.3
7.0 9.9 4.2
3.0 2.1 0.9
5.0 5.2 2.2
7.0 9.4 4.0
3.0 2.1 0.9
5.0 5.2 2.2
7.0 9.4 4.0
3.0 2.1 0.9
5.0 5.2 2.2
7.0 9.4 4.0
3.0 2.1 0.9
5.0 4.9 2.1
7.0 9.2 3.9
3.0 1.9 0.8
5.0 4.9 2.1
7.0 9.0 3.8
3.0 1.9 0.8
5.0 4.7 2.0
7.0 8.7 3.7
BTC 760108306 H | 12.2018
Operation Not Recommended
75/63 28.6 19.2 0.67 1.3 21.5
80.6/66.2 30.3 23.3 0.77 1.3 22.6
85/71 35.0 21.4 0.61 1.4 25.6
75/63 29.9 19.6 0.66 1.2 25.1
80.6/66.2 31.7 23.9 0.75 1.2 26.4
85/71 36.7 21.9 0.60 1.2 29.8
75/63 30.5 19.8 0.65 1.1 27.2
80.6/66.2 32.3 24.1 0.75 1.1 28.5
85/71 37.4 22.2 0.59 1.2 32.3
75/63 27.4 18.8 0.69 1.1 24.4
80.6/66.2 29.0 22.9 0.79 1.1 25.6
85/71 33.5 21.0 0.63 1.2 28.9
75/63 28.7 19.2 0.67 1.4 19.8
80.6/66.2 30.4 23.3 0.77 1.5 20.8
85/71 35.1 21.4 0.61 1.5 23.5
75/63 29.3 19.4 0.66 1.3 22.1
80.6/66.2 31.0 23.6 0.76 1.3 23.2
85/71 35.9 21.7 0.60 1.4 26.3
75/63 26.1 18.5 0.71 1.3 20.7
80.6/66.2 27.7 22.4 0.81 1.3 21.7
85/71 32.0 20.6 0.64 1.3 24.6
75/63 26.1 18.4 0.71 1.7 15.3
80.6/66.2 27.6 22.4 0.81 1.7 16.0
85/71 32.0 20.6 0.64 1.8 18.1
75/63 26.6 18.6 0.70 1.6 16.9
80.6/66.2 28.2 22.6 0.80 1.6 17.7
85/71 32.6 20.8 0.64 1.6 20.0
75/63 24.9 18.0 0.72 1.7 14.6
80.6/66.2 26.4 21.9 0.83 1.7 15.3
85/71 30.5 20.1 0.66 1.8 17.3
75/63 26.1 18.4 0.71 1.6 16.5
80.6/66.2 27.6 22.4 0.81 1.6 17.4
85/71 32.0 20.6 0.64 1.6 19.6
75/63 26.6 18.6 0.70 1.5 17.5
80.6/66.2 28.2 22.6 0.80 1.5 18.4
85/71 32.6 20.8 0.64 1.6 20.8
75/63 23.7 17.5 0.74 1.5 15.6
80.6/66.2 25.1 21.3 0.85 1.5 16.3
85/71 29.0 19.6 0.67 1.6 18.5
75/63 24.8 18.0 0.72 1.9 13.3
80.6/66.2 26.3 21.9 0.83 1.9 14.0
85/71 30.4 20.1 0.66 1.9 15.8
75/63 25.3 18.2 0.72 1.7 14.7
80.6/66.2 26.8 22.1 0.82 1.7 15.4
85/71 31.0 20.3 0.65 1.8 17.5
75/63 22.5 17.1 0.76 1.7 13.5
80.6/66.2 23.8 20.7 0.87 1.7 14.2
85/71 27.5 19.1 0.69 1.7 16.0
75/63 23.5 17.5 0.75 2.0 11.5
80.6/66.2 24.9 21.3 0.86 2.1 12.1
85/71 28.8 19.6 0.68 2.1 13.7
75/63 24.0 17.7 0.74 1.9 12.7
80.6/66.2 25.4 21.5 0.85 1.9 13.4
85/71 29.4 19.8 0.67 1.9 15.1
75/63 21.2 16.8 0.79 1.8 11.6
80.6/66.2 22.4 20.4 0.91 1.8 12.2
85/71 25.9 18.7 0.72 1.9 13.8
75/63 22.2 17.1 0.77 2.2 10.0
80.6/66.2 23.5 20.8 0.88 2.2 10.4
85/71 27.1 19.1 0.70 2.3 11.8
75/63 22.6 17.1 0.76 2.1 10.9
80.6/66.2 24.0 20.8 0.87 2.1 11.5
85/71 27.7 19.1 0.69 2.1 13.0
75/63 20.0 16.3 0.82 2.0 10.0
80.6/66.2 21.2 19.8 0.94 2.0 10.5
85/71 24.5 18.2 0.74 2.1 11.8
75/63 20.9 16.7 0.80 2.5 8.5
80.6/66.2 22.1 20.3 0.92 2.5 8.9
85/71 25.5 18.6 0.73 2.5 10.1
75/63 21.3 16.7 0.78 2.3 9.3
80.6/66.2 22.5 20.3 0.90 2.3 9.8
85/71 26.1 18.7 0.72 2.4 11.1
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 12
SM Series -
Residential Geothermal Heat Pumps
SM024 Full Load Heating Performance Data - 900 SCFM 254 Fan Watts .6 ESP
Entering
Water Temp °F
20
30
40
50
60
70
80
Water fl ow
GPM
3.0 2.4 1.0
5.0 5.9 2.5
7.0 10.6 4.5
3.0 2.4 1.0
5.0 5.7 2.4
7.0 10.4 4.4
3.0 2.1 0.9
5.0 5.4 2.3
7.0 10.1 4.3
3.0 2.1 0.9
5.0 5.4 2.3
7.0 9.9 4.2
3.0 2.1 0.9
5.0 5.2 2.2
7.0 9.4 4.0
3.0 2.1 0.9
5.0 5.2 2.2
7.0 9.4 4.0
3.0 2.1 0.9
5.0 5.2 2.2
7.0 9.4 4.0
3.0 2.1 0.9
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT °F DB
60 15.6 10.1 1.40 3.3
68 15.9 10.8 1.49 3.1
80 16.2 11.3 1.55 3.0
60 16.5 10.7 1.41 3.4
68 16.8 11.4 1.51 3.3
80 17.0 11.9 1.57 3.2
60 16.9 11.0 1.42 3.5
68 17.2 11.7 1.52 3.3
80 17.4 12.2 1.58 3.2
60 17.8 11.8 1.44 3.6
68 18.1 12.6 1.54 3.5
80 18.4 13.1 1.60 3.4
60 18.8 12.6 1.45 3.8
68 19.2 13.5 1.56 3.6
80 19.5 14.1 1.62 3.5
60 19.3 13.1 1.46 3.9
68 19.7 14.0 1.57 3.7
80 20.0 14.5 1.63 3.6
60 20.1 13.7 1.48 4.0
68 20.5 14.7 1.58 3.8
80 20.8 15.3 1.65 3.7
60 21.4 14.8 1.51 4.2
68 21.8 15.9 1.61 4.0
80 22.1 16.5 1.68 3.9
60 22.1 15.4 1.52 4.3
68 22.4 16.4 1.62 4.0
80 22.8 17.1 1.69 3.9
60 22.6 15.8 1.53 4.3
68 22.9 16.9 1.63 4.1
80 23.3 17.6 1.70 4.0
60 24.2 17.3 1.56 4.5
68 24.6 18.5 1.67 4.3
80 25.0 19.2 1.74 4.2
60 25.0 17.9 1.58 4.6
68 25.4 19.1 1.69 4.4
80 25.8 19.9 1.76 4.3
60 25.2 18.1 1.58 4.7
68 25.6 19.4 1.69 4.4
80 26.1 20.1 1.76 4.3
60 27.0 19.6 1.62 4.9
68 27.5 21.0 1.73 4.7
80 27.9 21.8 1.80 4.5
60 28.1 20.5 1.64 5.0
68 28.5 21.9 1.75 4.8
80 29.0 22.8 1.82 4.7
60 27.9 20.4 1.64 5.0
68 28.4 21.9 1.75 4.8
80 28.9 22.7 1.82 4.6
60 30.1 22.3 1.67 5.3
68 30.7 23.9 1.78 5.0
80 31.1 24.8 1.86 4.9
60 31.4 23.5 1.69 5.5
68 31.9 25.2 1.80 5.2
80 32.4 26.2 1.88 5.1
60 30.8 23.0 1.68 5.4
68 31.4 24.6 1.79 5.1
80 31.9 25.6 1.87 5.0
60 33.3 25.2 1.72 5.7
68 33.9 26.9 1.84 5.4
80 34.4 28.0 1.91 5.3
60 34.6 26.2 1.74 5.8
68 35.2 28.1 1.86 5.5
80 35.7 29.2 1.94 5.4
Total
KBtu/hr.
Engineering Submittal Sheet
Heat of Absp
kBtu/hr
Power kW COP
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
12 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
5.0 4.9 2.1
7.0 9.2 3.9
3.0 1.9 0.8
5.0 4.9 2.1
7.0 9.0 3.8
3.0 1.9 0.8
5.0 4.7 2.0
7.0 8.7 3.7
BTC 760108306 H | 12.2018
Operation Not Recommended
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 13
SM Series -
Residential Geothermal Heat Pumps
SM024 Partial Load Cooling Performance Data - 800 SCFM 197 Fan Watts .6 ESP
Entering
Water Temp °F
Water fl ow
GPM
3.0 2.4 1.0
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT
°F DB / °F WB
Operation Not Recom-
mended
Total
KBtu/hr.
Latent
Capacity Kbtu/hr
Engineering Submittal Sheet
SHR Power kW EER
20
30
40
50
60
70
80
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
13 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
5.0 5.7 2.4
7.0 10.4 4.4
3.0 2.1 0.9
5.0 5.7 2.4
7.0 10.1 4.3
3.0 2.1 0.9
5.0 5.4 2.3
7.0 9.9 4.2
3.0 2.1 0.9
5.0 5.4 2.3
7.0 9.7 4.1
3.0 2.1 0.9
5.0 5.2 2.2
7.0 9.4 4.0
3.0 2.1 0.9
5.0 5.2 2.2
7.0 9.4 4.0
3.0 2.1 0.9
5.0 4.9 2.1
7.0 9.2 3.9
3.0 1.9 0.8
5.0 4.9 2.1
7.0 9.0 3.8
3.0 1.9 0.8
5.0 4.7 2.0
7.0 8.7 3.7
3.0 9.2 3.9
5.0 9.7 4.1
7.0 9.7 4.1
BTC 760108306 H | 12.2018
Operation Not Recommended
75/63 22.3 16.1 0.72 0.8 27.4
80.6/66.2 23.6 19.5 0.83 0.8 28.7
85/71 27.3 17.9 0.66 0.8 32.5
75/63 23.2 16.4 0.71 0.8 30.8
80.6/66.2 24.5 19.9 0.81 0.8 32.3
85/71 28.4 18.3 0.64 0.8 36.5
75/63 23.6 16.5 0.70 0.7 32.3
80.6/66.2 25.0 20.1 0.80 0.7 33.9
85/71 28.9 18.4 0.64 0.8 38.4
75/63 21.3 15.7 0.74 0.9 23.6
80.6/66.2 22.5 19.0 0.84 0.9 24.8
85/71 26.1 17.5 0.67 0.9 28.1
75/63 22.1 16.0 0.72 0.8 26.7
80.6/66.2 23.4 19.4 0.83 0.8 28.0
85/71 27.1 17.8 0.66 0.9 31.7
75/63 22.5 16.1 0.72 0.8 28.1
80.6/66.2 23.8 19.6 0.82 0.8 29.5
85/71 27.5 18.0 0.65 0.8 33.4
75/63 20.5 15.5 0.76 1.0 20.4
80.6/66.2 21.7 18.8 0.87 1.0 21.4
85/71 25.1 17.3 0.69 1.0 24.2
75/63 21.3 15.7 0.74 0.9 23.2
80.6/66.2 22.6 19.1 0.85 0.9 24.3
85/71 26.1 17.5 0.67 0.9 27.5
75/63 21.4 15.7 0.73 0.9 24.1
80.6/66.2 22.7 19.1 0.84 0.9 25.2
85/71 26.2 17.5 0.67 0.9 28.6
75/63 19.4 15.1 0.78 1.1 17.2
80.6/66.2 20.5 18.4 0.90 1.1 18.1
85/71 23.7 16.9 0.71 1.2 20.5
75/63 20.2 15.4 0.76 1.0 19.5
80.6/66.2 21.4 18.7 0.87 1.0 20.5
85/71 24.7 17.2 0.70 1.1 23.2
75/63 20.5 15.5 0.75 1.0 20.6
80.6/66.2 21.8 18.8 0.87 1.0 21.7
85/71 25.2 17.3 0.69 1.0 24.5
75/63 19.4 15.1 0.78 1.1 17.2
80.6/66.2 20.5 18.4 0.90 1.1 18.1
85/71 23.7 16.9 0.71 1.2 20.5
75/63 20.2 15.4 0.76 1.0 19.5
80.6/66.2 21.4 18.7 0.87 1.0 20.5
85/71 24.7 17.2 0.70 1.1 23.2
75/63 20.5 15.5 0.75 1.0 20.6
80.6/66.2 21.8 18.8 0.87 1.0 21.7
85/71 25.2 17.3 0.69 1.0 24.5
75/63 18.3 14.7 0.80 1.3 14.5
80.6/66.2 19.4 17.9 0.92 1.3 15.2
85/71 22.4 16.4 0.73 1.3 17.2
75/63 19.0 15.0 0.79 1.2 16.4
80.6/66.2 20.1 18.2 0.90 1.2 17.2
85/71 23.3 16.7 0.72 1.2 19.4
75/63 19.4 15.1 0.78 1.1 17.3
80.6/66.2 20.5 18.4 0.90 1.1 18.1
85/71 23.7 16.9 0.71 1.2 20.5
75/63 17.2 14.3 0.83 1.4 12.1
80.6/66.2 18.2 17.4 0.96 1.4 12.7
85/71 21.0 16.0 0.76 1.5 14.4
75/63 17.9 14.6 0.81 1.3 13.6
80.6/66.2 18.9 17.7 0.93 1.3 14.3
85/71 21.9 16.3 0.74 1.4 16.2
75/63 18.2 14.7 0.81 1.3 14.3
80.6/66.2 19.3 17.8 0.93 1.3 15.1
85/71 22.3 16.4 0.74 1.3 17.0
75/63 16.1 13.7 0.85 1.6 10.1
80.6/66.2 17.1 16.6 0.97 1.6 10.6
85/71 19.7 15.3 0.77 1.6 12.0
75/63 16.7 14.1 0.84 1.5 11.3
80.6/66.2 17.7 17.2 0.97 1.5 11.8
85/71 20.5 15.8 0.77 1.5 13.4
75/63 17.0 14.3 0.84 1.4 11.8
80.6/66.2 18.0 17.3 0.96 1.5 12.4
85/71 20.8 15.9 0.76 1.5 14.1
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 14
SM Series -
Residential Geothermal Heat Pumps
SM024 Partial Load Heating Performance Data - 800 SCFM 197 Fan Watts .6 ESP
Entering
Water Temp °F
20
30
40
50
60
70
80
Water fl ow
GPM
3.0 2.4 1.0
5.0 5.7 2.4
7.0 10.4 4.4
3.0 2.1 0.9
5.0 5.7 2.4
7.0 10.1 4.3
3.0 2.1 0.9
5.0 5.4 2.3
7.0 9.9 4.2
3.0 2.1 0.9
5.0 5.4 2.3
7.0 9.7 4.1
3.0 2.1 0.9
5.0 5.2 2.2
7.0 9.4 4.0
3.0 2.1 0.9
5.0 5.2 2.2
7.0 9.4 4.0
3.0 2.1 0.9
5.0 4.9 2.1
7.0 9.2 3.9
3.0 1.9 0.8
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT °F DB
60 11.3 7.1 1.09 3.0
68 11.5 7.6 1.17 2.9
80 11.7 7.9 1.22 2.8
60 11.9 7.5 1.10 3.2
68 12.1 8.1 1.18 3.0
80 12.3 8.4 1.22 2.9
60 12.2 7.8 1.10 3.2
68 12.4 8.3 1.18 3.1
80 12.6 8.6 1.23 3.0
60 13.3 8.8 1.11 3.5
68 13.5 9.4 1.19 3.3
80 13.7 9.8 1.24 3.2
60 14.0 9.4 1.12 3.7
68 14.2 10.1 1.20 3.5
80 14.4 10.5 1.25 3.4
60 14.3 9.7 1.12 3.7
68 14.5 10.4 1.20 3.5
80 14.8 10.8 1.25 3.5
60 15.3 10.7 1.13 4.0
68 15.6 11.4 1.21 3.8
80 15.9 11.9 1.26 3.7
60 16.3 11.4 1.13 4.2
68 16.5 12.2 1.21 4.0
80 16.8 12.6 1.26 3.9
60 16.7 11.7 1.14 4.3
68 17.0 12.6 1.22 4.1
80 17.2 13.1 1.27 4.0
60 17.5 12.6 1.14 4.5
68 17.8 13.4 1.22 4.3
80 18.0 14.0 1.27 4.2
60 18.5 13.5 1.15 4.7
68 18.8 14.4 1.23 4.5
80 19.1 15.0 1.28 4.4
60 19.1 13.9 1.15 4.9
68 19.4 14.9 1.23 4.6
80 19.7 15.5 1.28 4.5
60 19.7 14.6 1.15 5.0
68 20.0 15.6 1.23 4.8
80 20.3 16.2 1.28 4.7
60 20.9 15.7 1.15 5.3
68 21.3 16.8 1.23 5.1
80 21.6 17.5 1.28 4.9
60 21.6 16.2 1.15 5.5
68 21.9 17.3 1.23 5.2
80 22.3 18.0 1.28 5.1
60 21.9 16.6 1.15 5.6
68 22.3 17.8 1.23 5.3
80 22.6 18.5 1.29 5.2
60 23.3 17.9 1.16 5.9
68 23.7 19.2 1.24 5.6
80 24.1 20.0 1.29 5.5
60 24.1 18.5 1.16 6.1
68 24.5 19.8 1.24 5.8
80 24.9 20.6 1.29 5.7
60 24.2 18.7 1.16 6.1
68 24.6 20.0 1.24 5.8
80 25.0 20.8 1.29 5.7
60 25.8 20.2 1.16 6.5
68 26.3 21.6 1.24 6.2
80 26.7 22.5 1.29 6.1
60 26.7 20.9 1.16 6.8
68 27.2 22.3 1.24 6.4
80 27.6 23.2 1.29 6.3
Total
KBtu/hr.
Engineering Submittal Sheet
Heat of Absp
kBtu/hr
Power kW COP
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in
a change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
14 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
5.0 4.9 2.1
7.0 9.0 3.8
3.0 1.9 0.8
5.0 4.7 2.0
7.0 8.7 3.7
3.0 9.2 3.9
5.0 9.7 4.1
7.0 9.7 4.1
BTC 760108306 H | 12.2018
Operation Not Recommended
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 15
SM Series -
Residential Geothermal Heat Pumps
SM036 Full Load Cooling Performance Data - 1350 SCFM 311 Fan Watts .6 ESP
Entering
Water Temp °F
Water fl ow
GPM
5.0 8.7 3.7
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT
°F DB / °F WB
Operation Not Recom-
mended
Total
KBtu/hr.
Latent
Capacity Kbtu/hr
Engineering Submittal Sheet
SHR Power kW EER
20
30
40
50
60
70
80
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
15 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
7.5 9.0 3.8
10.0 9.2 3.9
5.0 2.8 1.2
7.5 5.9 2.5
10.0 9.7 4.1
5.0 2.8 1.2
7.5 5.7 2.4
10.0 9.7 4.1
5.0 2.8 1.2
7.5 5.7 2.4
10.0 9.4 4.0
5.0 2.6 1.1
7.5 5.4 2.3
10.0 9.2 3.9
5.0 2.6 1.1
7.5 5.4 2.3
10.0 9.0 3.8
5.0 2.6 1.1
7.5 5.2 2.2
10.0 8.7 3.7
5.0 2.6 1.1
7.5 5.2 2.2
10.0 8.7 3.7
5.0 2.4 1.0
7.5 5.2 2.2
10.0 8.5 3.6
5.0 2.4 1.0
7.5 4.9 2.1
10.0 8.2 3.5
BTC 760108306 H | 12.2018
Operation Not Recommended
75/63 44.4 29.5 0.66 1.9 23.9
80.6/66.2 47.0 35.8 0.76 1.9 25.0
85/71 54.4 32.9 0.61 1.9 28.3
75/63 45.9 30.0 0.65 1.8 25.7
80.6/66.2 48.6 36.5 0.75 1.8 26.9
85/71 56.2 33.5 0.60 1.8 30.5
75/63 46.7 30.2 0.65 1.8 26.6
80.6/66.2 49.5 36.7 0.74 1.8 27.9
85/71 57.2 33.7 0.59 1.8 31.6
75/63 42.5 28.8 0.68 1.8 24.2
80.6/66.2 45.0 35.0 0.78 1.8 25.4
85/71 52.0 32.2 0.62 1.8 28.7
75/63 44.0 29.2 0.66 2.0 22.3
80.6/66.2 46.6 35.5 0.76 2.0 23.4
85/71 53.9 32.6 0.60 2.0 26.4
75/63 44.7 29.6 0.66 1.9 23.7
80.6/66.2 47.4 35.9 0.76 1.9 24.9
85/71 54.8 33.0 0.60 1.9 28.2
75/63 40.5 28.1 0.69 1.8 22.0
80.6/66.2 42.9 34.2 0.80 1.9 23.1
85/71 49.6 31.4 0.63 1.9 26.1
75/63 42.1 28.5 0.68 2.1 19.8
80.6/66.2 44.5 34.6 0.78 2.1 20.8
85/71 51.5 31.8 0.62 2.2 23.5
75/63 42.7 28.9 0.67 2.0 21.2
80.6/66.2 45.3 35.1 0.77 2.0 22.3
85/71 52.3 32.2 0.62 2.1 25.2
75/63 37.7 28.4 0.75 2.0 19.2
80.6/66.2 39.9 34.5 0.87 2.0 20.2
85/71 46.1 31.7 0.69 2.0 22.8
75/63 39.9 28.0 0.70 2.3 17.4
80.6/66.2 42.2 34.0 0.81 2.3 18.3
85/71 48.8 31.2 0.64 2.4 20.7
75/63 40.7 28.1 0.69 2.2 18.7
80.6/66.2 43.1 34.2 0.79 2.2 19.7
85/71 49.8 31.4 0.63 2.2 22.2
75/63 36.0 27.4 0.76 2.1 17.1
80.6/66.2 38.2 33.2 0.87 2.1 17.9
85/71 44.1 30.6 0.69 2.2 20.3
75/63 38.6 26.1 0.68 2.5 15.4
80.6/66.2 40.8 31.7 0.78 2.5 16.1
85/71 47.2 29.1 0.62 2.6 18.3
75/63 38.0 28.1 0.74 2.4 16.0
80.6/66.2 40.3 34.1 0.85 2.4 16.8
85/71 46.6 31.3 0.67 2.4 19.0
75/63 34.3 26.2 0.77 2.3 14.9
80.6/66.2 36.3 31.9 0.88 2.3 15.7
85/71 41.9 29.3 0.70 2.4 17.7
75/63 36.4 25.5 0.70 2.8 13.2
80.6/66.2 38.5 31.0 0.80 2.8 13.9
85/71 44.5 28.5 0.64 2.8 15.7
75/63 36.0 27.2 0.75 2.6 13.8
80.6/66.2 38.1 33.0 0.87 2.6 14.5
85/71 44.1 30.3 0.69 2.7 16.4
75/63 32.7 25.0 0.77 2.5 13.0
80.6/66.2 34.6 30.4 0.88 2.5 13.6
85/71 40.0 27.9 0.70 2.6 15.4
75/63 33.7 25.6 0.76 3.0 11.1
80.6/66.2 35.7 31.1 0.87 3.1 11.7
85/71 41.2 28.6 0.69 3.1 13.2
75/63 34.4 25.7 0.75 2.9 12.0
80.6/66.2 36.4 31.3 0.86 2.9 12.6
85/71 42.1 28.7 0.68 3.0 14.2
75/63 30.7 24.2 0.79 2.8 11.0
80.6/66.2 32.5 29.5 0.91 2.8 11.6
85/71 37.6 27.1 0.72 2.9 13.1
75/63 31.7 24.7 0.78 3.3 9.5
80.6/66.2 33.6 30.0 0.89 3.4 10.0
85/71 38.8 27.6 0.71 3.4 11.3
75/63 32.3 24.9 0.77 3.2 10.2
80.6/66.2 34.2 30.3 0.89 3.2 10.7
85/71 39.6 27.8 0.70 3.3 12.1
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 16
SM Series -
Residential Geothermal Heat Pumps
SM036 Full Load Heating Performance Data - 1350 SCFM 311 Fan Watts .6 ESP
Entering
Water Temp °F
20
30
40
50
60
70
80
Water fl ow
GPM
5.0 8.7 3.7
7.5 9.0 3.8
10.0 9.2 3.9
5.0 2.8 1.2
7.5 5.9 2.5
10.0 9.7 4.1
5.0 2.8 1.2
7.5 5.7 2.4
10.0 9.7 4.1
5.0 2.8 1.2
7.5 5.7 2.4
10.0 9.4 4.0
5.0 2.6 1.1
7.5 5.4 2.3
10.0 9.2 3.9
5.0 2.6 1.1
7.5 5.4 2.3
10.0 9.0 3.8
5.0 2.6 1.1
7.5 5.2 2.2
10.0 8.7 3.7
5.0 2.6 1.1
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT °F DB
60 23.3 15.2 1.96 3.5
68 23.8 16.3 2.09 3.3
80 24.1 17.0 2.18 3.2
60 24.1 16.1 1.97 3.6
68 24.5 17.2 2.11 3.4
80 24.9 17.9 2.19 3.3
60 24.8 16.7 1.98 3.7
68 25.3 17.9 2.12 3.5
80 25.7 18.6 2.21 3.4
60 27.1 18.3 2.01 3.9
68 27.6 19.6 2.15 3.7
80 28.0 20.4 2.24 3.7
60 28.1 19.2 2.03 4.1
68 28.6 20.6 2.17 3.9
80 29.1 21.4 2.26 3.8
60 28.9 20.0 2.05 4.1
68 29.4 21.4 2.19 3.9
80 29.9 22.3 2.28 3.8
60 30.8 21.6 2.08 4.3
68 31.3 23.2 2.22 4.1
80 31.8 24.1 2.31 4.0
60 31.9 22.8 2.10 4.5
68 32.5 24.4 2.24 4.2
80 33.0 25.4 2.34 4.1
60 33.0 23.7 2.12 4.6
68 33.6 25.4 2.27 4.3
80 34.1 26.4 2.36 4.2
60 34.8 25.1 2.14 4.8
68 35.4 26.9 2.29 4.5
80 35.9 28.0 2.39 4.4
60 36.3 26.7 2.17 4.9
68 37.0 28.6 2.33 4.7
80 37.5 29.7 2.42 4.5
60 37.6 27.7 2.20 5.0
68 38.3 29.7 2.35 4.8
80 38.9 30.9 2.45 4.7
60 38.9 28.8 2.22 5.1
68 39.5 30.8 2.37 4.9
80 40.1 32.1 2.47 4.8
60 40.7 30.5 2.25 5.3
68 41.4 32.7 2.41 5.0
80 42.1 34.0 2.51 4.9
60 42.5 32.0 2.28 5.5
68 43.2 34.2 2.44 5.2
80 43.9 35.6 2.54 5.1
60 43.3 32.7 2.29 5.5
68 44.0 35.0 2.45 5.3
80 44.7 36.4 2.55 5.1
60 45.6 34.7 2.33 5.7
68 46.4 37.1 2.49 5.4
80 47.1 38.7 2.60 5.3
60 47.5 36.4 2.36 5.9
68 48.3 39.0 2.53 5.6
80 49.1 40.6 2.63 5.5
60 47.9 36.7 2.37 5.9
68 48.7 39.3 2.54 5.6
80 49.5 40.9 2.64 5.5
60 50.5 39.0 2.42 6.1
68 51.4 41.8 2.59 5.8
80 52.2 43.5 2.69 5.7
60 52.8 41.4 2.46 6.3
68 53.7 44.3 2.63 6.0
80 54.6 46.1 2.74 5.8
Total
KBtu/hr.
Engineering Submittal Sheet
Heat of Absp
kBtu/hr
Power kW COP
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
16 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
7.5 5.2 2.2
10.0 8.7 3.7
5.0 2.4 1.0
7.5 5.2 2.2
10.0 8.5 3.6
5.0 2.4 1.0
7.5 4.9 2.1
10.0 8.2 3.5
BTC 760108306 H | 12.2018
Operation Not Recommended
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 17
SM Series -
Residential Geothermal Heat Pumps
SM036 Partial Load Cooling Performance Data - 1223 SCFM -260 Fan Watts .6 ESP
Entering
Water Temp °F
Water fl ow
GPM
5.0 8.7 3.7
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT
°F DB / °F WB
Operation Not Recom-
mended
Total
KBtu/hr.
Capacity Kbtu/hr
Latent
Engineering Submittal Sheet
SHR Power kW EER
20
30
40
50
60
70
80
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
17 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
7.5 9.0 3.8
10.0 9.2 3.9
5.0 2.8 1.2
7.5 5.9 2.5
10.0 9.7 4.1
5.0 2.8 1.2
7.5 5.7 2.4
10.0 9.7 4.1
5.0 2.8 1.2
7.5 5.7 2.4
10.0 9.4 4.0
5.0 2.6 1.1
7.5 5.4 2.3
10.0 9.2 3.9
5.0 2.6 1.1
7.5 5.4 2.3
10.0 9.0 3.8
5.0 2.6 1.1
7.5 5.2 2.2
10.0 9.0 3.8
5.0 2.6 1.1
7.5 5.2 2.2
10.0 8.7 3.7
5.0 2.4 1.0
7.5 5.2 2.2
10.0 8.5 3.6
5.0 2.4 1.0
7.5 4.9 2.1
10.0 8.2 3.5
BTC 760108306 H | 12.2018
Operation Not Recommended
75/63 33.3 24.5 0.74 1.1 30.0
80.6/66.2 35.2 29.7 0.84 1.1 31.5
85/71 40.7 27.3 0.67 1.1 35.7
75/63 34.2 24.8 0.73 1.1 31.9
80.6/66.2 36.2 30.2 0.83 1.1 33.5
85/71 41.8 27.7 0.66 1.1 37.9
75/63 34.6 25.0 0.72 1.1 32.9
80.6/66.2 36.7 30.4 0.83 1.1 34.5
85/71 42.4 27.9 0.66 1.1 39.0
75/63 31.7 23.9 0.75 1.2 26.5
80.6/66.2 33.6 29.1 0.87 1.2 27.8
85/71 38.8 26.7 0.69 1.2 31.5
75/63 32.6 24.2 0.74 1.1 28.6
80.6/66.2 34.5 29.4 0.85 1.2 30.0
85/71 39.9 27.1 0.68 1.2 33.9
75/63 33.1 24.4 0.74 1.1 29.6
80.6/66.2 35.0 29.7 0.85 1.1 31.1
85/71 40.5 27.2 0.67 1.2 35.2
75/63 30.1 23.4 0.78 1.3 22.9
80.6/66.2 31.9 28.4 0.89 1.3 24.0
85/71 36.8 26.1 0.71 1.4 27.1
75/63 31.0 23.7 0.76 1.2 24.8
80.6/66.2 32.8 28.8 0.88 1.3 26.1
85/71 37.9 26.4 0.70 1.3 29.5
75/63 31.5 23.8 0.76 1.2 25.9
80.6/66.2 33.3 28.9 0.87 1.2 27.2
85/71 38.5 26.6 0.69 1.3 30.8
75/63 28.4 22.9 0.80 1.5 19.4
80.6/66.2 30.1 27.8 0.92 1.5 20.3
85/71 34.8 25.5 0.73 1.5 23.0
75/63 29.4 23.0 0.78 1.4 21.2
80.6/66.2 31.1 28.0 0.90 1.4 22.2
85/71 35.9 25.7 0.72 1.4 25.2
75/63 29.8 23.2 0.78 1.3 22.1
80.6/66.2 31.5 28.2 0.89 1.4 23.2
85/71 36.5 25.9 0.71 1.4 26.3
75/63 26.8 22.2 0.83 1.7 16.3
80.6/66.2 28.4 27.0 0.95 1.7 17.1
85/71 32.8 24.8 0.76 1.7 19.3
75/63 27.6 22.5 0.81 1.6 17.7
80.6/66.2 29.2 27.3 0.93 1.6 18.6
85/71 33.8 25.1 0.74 1.6 21.1
75/63 28.0 22.6 0.81 1.5 18.5
80.6/66.2 29.7 27.5 0.93 1.5 19.4
85/71 34.3 25.3 0.74 1.6 22.0
75/63 25.3 21.3 0.84 1.9 13.6
80.6/66.2 26.8 25.9 0.97 1.9 14.3
85/71 31.0 23.8 0.77 1.9 16.1
75/63 26.0 21.7 0.84 1.8 14.8
80.6/66.2 27.5 26.4 0.96 1.8 15.5
85/71 31.8 24.3 0.76 1.8 17.5
75/63 26.4 21.9 0.83 1.7 15.4
80.6/66.2 27.9 26.7 0.95 1.7 16.1
85/71 32.3 24.5 0.76 1.8 18.3
75/63 23.9 20.3 0.85 2.1 11.3
80.6/66.2 25.3 24.6 0.97 2.1 11.9
85/71 29.2 22.6 0.77 2.2 13.5
75/63 24.4 20.7 0.85 2.0 12.2
80.6/66.2 25.9 25.2 0.97 2.0 12.8
85/71 29.9 23.2 0.77 2.1 14.5
75/63 24.8 20.9 0.85 1.9 12.7
80.6/66.2 26.2 25.5 0.97 2.0 13.3
85/71 30.3 23.4 0.77 2.0 15.1
75/63 22.3 19.0 0.85 2.4 9.4
80.6/66.2 23.6 23.1 0.97 2.4 9.9
85/71 27.3 21.2 0.77 2.4 11.2
75/63 22.9 19.5 0.85 2.3 10.1
80.6/66.2 24.3 23.7 0.97 2.3 10.6
85/71 28.1 21.7 0.77 2.3 12.0
75/63 23.2 19.7 0.85 2.2 10.5
80.6/66.2 24.6 24.0 0.97 2.2 11.0
85/71 28.4 22.0 0.77 2.3 12.5
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 18
SM Series -
Residential Geothermal Heat Pumps
SM036 Partial Load Heating Performance Data - 1223 SCFM -260 Fan Watts .6 ESP
Entering
Water Temp °F
20
30
40
50
60
70
80
Water fl ow
GPM
5.0 8.7 3.7
7.5 9.0 3.8
10.0 9.2 3.9
5.0 2.8 1.2
7.5 5.9 2.5
10.0 9.7 4.1
5.0 2.8 1.2
7.5 5.7 2.4
10.0 9.7 4.1
5.0 2.8 1.2
7.5 5.7 2.4
10.0 9.4 4.0
5.0 2.6 1.1
7.5 5.4 2.3
10.0 9.2 3.9
5.0 2.6 1.1
7.5 5.4 2.3
10.0 9.0 3.8
5.0 2.6 1.1
7.5 5.2 2.2
10.0 9.0 3.8
5.0 2.6 1.1
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT °F DB
60 16.4 10.4 1.38 3.5
68 16.7 11.1 1.48 3.3
80 17.0 11.5 1.54 3.2
60 16.9 10.8 1.38 3.6
68 17.2 11.5 1.48 3.4
80 17.5 12.0 1.54 3.3
60 17.3 11.2 1.38 3.7
68 17.6 11.9 1.48 3.5
80 17.9 12.4 1.54 3.4
60 19.4 12.7 1.39 4.1
68 19.8 13.6 1.49 3.9
80 20.1 14.2 1.55 3.8
60 19.9 13.5 1.39 4.2
68 20.3 14.4 1.49 4.0
80 20.6 15.0 1.55 3.9
60 20.5 14.0 1.39 4.3
68 20.8 14.9 1.49 4.1
80 21.1 15.6 1.55 4.0
60 22.4 15.8 1.40 4.7
68 22.8 16.9 1.49 4.5
80 23.1 17.6 1.55 4.4
60 23.2 16.3 1.40 4.9
68 23.6 17.5 1.49 4.6
80 24.0 18.2 1.56 4.5
60 23.8 17.1 1.40 5.0
68 24.2 18.3 1.50 4.7
80 24.6 19.1 1.56 4.6
60 25.8 18.7 1.40 5.4
68 26.2 20.1 1.50 5.1
80 26.6 20.9 1.56 5.0
60 26.9 19.6 1.40 5.6
68 27.4 21.0 1.50 5.4
80 27.8 21.8 1.56 5.2
60 27.5 20.5 1.40 5.7
68 28.0 21.9 1.50 5.5
80 28.4 22.8 1.56 5.3
60 29.5 21.9 1.41 6.1
68 30.0 23.4 1.51 5.8
80 30.4 24.4 1.57 5.7
60 30.6 23.0 1.41 6.4
68 31.2 24.6 1.51 6.1
80 31.7 25.6 1.57 5.9
60 31.4 24.2 1.41 6.5
68 31.9 25.9 1.51 6.2
80 32.4 26.9 1.57 6.1
60 33.1 25.2 1.41 6.9
68 33.6 27.0 1.51 6.5
80 34.2 28.1 1.57 6.4
60 34.5 26.5 1.41 7.2
68 35.1 28.4 1.51 6.8
80 35.6 29.5 1.57 6.6
60 35.7 27.6 1.41 7.4
68 36.3 29.5 1.51 7.0
80 36.8 30.7 1.57 6.9
60 36.8 28.6 1.41 7.6
68 37.5 30.6 1.51 7.3
80 38.0 31.9 1.58 7.1
60 38.2 30.2 1.41 7.9
68 38.9 32.3 1.51 7.5
80 39.5 33.7 1.57 7.4
60 39.6 31.7 1.41 8.2
68 40.3 33.9 1.51 7.8
80 40.9 35.3 1.57 7.6
Total
KBtu/hr.
Engineering Submittal Sheet
Heat of Absp
kBtu/hr
Power kW COP
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
18 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
7.5 5.2 2.2
10.0 8.7 3.7
5.0 2.4 1.0
7.5 5.2 2.2
10.0 8.5 3.6
5.0 2.4 1.0
7.5 4.9 2.1
10.0 8.2 3.5
BTC 760108306 H | 12.2018
Operation Not Recommended
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 19
SM Series -
Residential Geothermal Heat Pumps
SM048 Full Load Cooling Performance Data - 1600 SCFM -445 Fan Watts .6 ESP
Entering
Water Temp °F
Water fl ow
GPM
6.0 10.6 4.5
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT
°F DB / °F WB
Operation Not Recom-
mended
Total
KBtu/hr.
Latent
Capacity Kbtu/hr
Engineering Submittal Sheet
SHR Power kW EER
20
30
40
50
60
70
80
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
19 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
9.0 10.8 4.6
12.0 11.1 4.7
6.0 3.3 1.4
9.0 7.1 3.0
12.0 11.8 5.0
6.0 3.3 1.4
9.0 6.8 2.9
12.0 11.5 4.9
6.0 3.3 1.4
9.0 6.8 2.9
12.0 11.3 4.8
6.0 3.3 1.4
9.0 6.6 2.8
12.0 11.1 4.7
6.0 3.1 1.3
9.0 6.6 2.8
12.0 10.8 4.6
6.0 3.1 1.3
9.0 6.4 2.7
12.0 10.6 4.5
6.0 3.1 1.3
9.0 6.4 2.7
12.0 10.4 4.4
6.0 3.1 1.3
9.0 6.1 2.6
12.0 10.4 4.4
6.0 2.8 1.2
9.0 6.1 2.6
12.0 10.1 4.3
BTC 760108306 H | 12.2018
Operation Not Recommended
75/63 55.8 35.8 0.64 2.5 22.5
80.6/66.2 59.1 43.4 0.74 2.5 23.6
85/71 68.4 39.9 0.58 2.6 26.7
75/63 58.0 36.5 0.63 2.3 25.3
80.6/66.2 61.4 44.4 0.72 2.3 26.6
85/71 71.0 40.8 0.57 2.4 30.1
75/63 59.0 37.0 0.63 2.2 27.0
80.6/66.2 62.5 45.0 0.72 2.2 28.3
85/71 72.3 41.3 0.57 2.3 32.1
75/63 53.6 35.0 0.65 2.7 19.8
80.6/66.2 56.7 42.5 0.75 2.7 20.7
85/71 65.6 39.0 0.60 2.8 23.5
75/63 55.6 35.7 0.64 2.5 22.2
80.6/66.2 58.9 43.4 0.74 2.5 23.3
85/71 68.1 39.9 0.59 2.6 26.3
75/63 56.6 36.1 0.64 2.4 23.6
80.6/66.2 60.0 43.9 0.73 2.4 24.7
85/71 69.3 40.3 0.58 2.5 28.0
75/63 51.1 34.3 0.67 3.0 17.3
80.6/66.2 54.1 41.7 0.77 3.0 18.1
85/71 62.5 38.3 0.61 3.0 20.5
75/63 53.2 34.9 0.66 2.7 19.4
80.6/66.2 56.3 42.4 0.75 2.8 20.4
85/71 65.1 39.0 0.60 2.8 23.0
75/63 54.2 35.3 0.65 2.6 20.6
80.6/66.2 57.4 42.9 0.75 2.7 21.6
85/71 66.4 39.4 0.59 2.7 24.4
75/63 48.7 33.4 0.69 3.2 15.1
80.6/66.2 51.6 40.6 0.79 3.3 15.8
85/71 59.7 37.3 0.62 3.3 17.9
75/63 50.7 34.0 0.67 3.0 16.9
80.6/66.2 53.7 41.3 0.77 3.0 17.7
85/71 62.1 38.0 0.61 3.1 20.0
75/63 51.8 34.3 0.66 2.9 17.9
80.6/66.2 54.9 41.7 0.76 2.9 18.8
85/71 63.4 38.3 0.60 3.0 21.3
75/63 46.4 32.4 0.70 3.6 13.1
80.6/66.2 49.1 39.4 0.80 3.6 13.7
85/71 56.8 36.2 0.64 3.7 15.5
75/63 48.3 33.0 0.68 3.3 14.6
80.6/66.2 51.1 40.1 0.79 3.3 15.3
85/71 59.1 36.9 0.62 3.4 17.3
75/63 49.2 33.5 0.68 3.2 15.5
80.6/66.2 52.1 40.7 0.78 3.2 16.2
85/71 60.2 37.4 0.62 3.3 18.3
75/63 44.4 30.4 0.68 3.9 11.3
80.6/66.2 47.1 37.0 0.79 4.0 11.9
85/71 54.4 34.0 0.62 4.1 13.4
75/63 45.6 32.2 0.71 3.6 12.5
80.6/66.2 48.3 39.1 0.81 3.7 13.1
85/71 55.9 36.0 0.64 3.8 14.9
75/63 46.6 32.6 0.70 3.5 13.2
80.6/66.2 49.3 39.7 0.80 3.5 13.9
85/71 57.0 36.5 0.64 3.6 15.7
75/63 41.9 29.6 0.71 4.3 9.6
80.6/66.2 44.3 36.0 0.81 4.4 10.1
85/71 51.3 33.1 0.65 4.5 11.4
75/63 42.3 32.4 0.77 4.0 10.5
80.6/66.2 44.8 39.4 0.88 4.1 11.0
85/71 51.7 36.2 0.70 4.2 12.4
75/63 43.9 31.7 0.72 3.9 11.2
80.6/66.2 46.5 38.5 0.83 3.9 11.8
85/71 53.8 35.4 0.66 4.0 13.3
75/63 38.7 30.0 0.77 4.8 8.0
80.6/66.2 41.0 36.5 0.89 4.9 8.4
85/71 47.4 33.5 0.71 5.0 9.5
75/63 39.8 31.2 0.78 4.5 8.8
80.6/66.2 42.2 38.0 0.90 4.6 9.3
85/71 48.8 34.9 0.71 4.7 10.5
75/63 41.7 29.6 0.71 4.4 9.5
80.6/66.2 44.2 36.0 0.82 4.4 10.0
85/71 51.1 33.1 0.65 4.5 11.3
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 20
SM Series -
Residential Geothermal Heat Pumps
SM048 Full Load Heating Performance Data - 1600 SCFM -445 Fan Watts .6 ESP
Entering
Water Temp °F
20
30
40
50
60
70
80
Water fl ow
GPM
6.0 10.6 4.5
9.0 10.8 4.6
12.0 11.1 4.7
6.0 3.3 1.4
9.0 7.1 3.0
12.0 11.8 5.0
6.0 3.3 1.4
9.0 6.8 2.9
12.0 11.5 4.9
6.0 3.3 1.4
9.0 6.8 2.9
12.0 11.3 4.8
6.0 3.3 1.4
9.0 6.6 2.8
12.0 11.1 4.7
6.0 3.1 1.3
9.0 6.6 2.8
12.0 10.8 4.6
6.0 3.1 1.3
9.0 6.4 2.7
12.0 10.6 4.5
6.0 3.1 1.3
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT °F DB
60 30.3 19.2 2.65 3.4
68 30.8 20.5 2.83 3.2
80 31.3 21.4 2.95 3.1
60 31.5 20.3 2.67 3.5
68 32.0 21.7 2.86 3.3
80 32.5 22.6 2.98 3.2
60 32.3 20.9 2.69 3.5
68 32.9 22.3 2.88 3.3
80 33.4 23.3 3.00 3.3
60 34.8 23.0 2.74 3.7
68 35.4 24.6 2.93 3.5
80 35.9 25.6 3.05 3.4
60 36.5 24.4 2.78 3.8
68 37.1 26.1 2.97 3.7
80 37.7 27.2 3.09 3.6
60 37.5 25.3 2.80 3.9
68 38.1 27.0 3.00 3.7
80 38.7 28.1 3.12 3.6
60 39.6 27.0 2.84 4.1
68 40.3 28.9 3.04 3.9
80 40.9 30.0 3.17 3.8
60 41.7 28.8 2.89 4.2
68 42.4 30.8 3.09 4.0
80 43.1 32.1 3.22 3.9
60 42.8 29.8 2.92 4.3
68 43.5 31.9 3.12 4.1
80 44.2 33.2 3.25 4.0
60 44.5 31.2 2.95 4.4
68 45.2 33.4 3.15 4.2
80 46.0 34.7 3.28 4.1
60 47.2 33.6 2.99 4.6
68 48.0 35.9 3.21 4.4
80 48.8 37.4 3.34 4.3
60 48.7 34.9 3.02 4.7
68 49.6 37.3 3.24 4.5
80 50.4 38.9 3.37 4.4
60 49.8 35.8 3.04 4.8
68 50.7 38.3 3.26 4.6
80 51.5 39.8 3.39 4.5
60 53.0 38.6 3.10 5.0
68 54.0 41.3 3.32 4.8
80 54.8 43.0 3.46 4.6
60 54.8 40.1 3.14 5.1
68 55.7 42.9 3.36 4.9
80 56.6 44.7 3.49 4.7
60 55.5 40.6 3.15 5.2
68 56.5 43.5 3.37 4.9
80 57.3 45.2 3.50 4.8
60 59.1 43.6 3.21 5.4
68 60.1 46.6 3.44 5.1
80 61.0 48.5 3.58 5.0
60 61.2 45.7 3.25 5.5
68 62.3 48.9 3.48 5.2
80 63.3 50.9 3.62 5.1
60 61.2 45.6 3.25 5.5
68 62.3 48.8 3.48 5.2
80 63.3 50.8 3.62 5.1
60 65.4 49.0 3.33 5.8
68 66.5 52.4 3.56 5.5
80 67.6 54.6 3.71 5.3
60 67.9 51.5 3.38 5.9
68 69.0 55.1 3.61 5.6
80 70.1 57.3 3.76 5.5
Total
KBtu/hr.
Engineering Submittal Sheet
Heat of Absp
kBtu/hr
Power kW COP
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
20 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
9.0 6.4 2.7
12.0 10.4 4.4
6.0 3.1 1.3
9.0 6.1 2.6
12.0 10.4 4.4
6.0 2.8 1.2
9.0 6.1 2.6
12.0 10.1 4.3
BTC 760108306 H | 12.2018
Operation Not Recommended
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 21
SM Series -
Residential Geothermal Heat Pumps
SM048 Partial Load Cooling Performance Data - 1263 SCFM -294 Fan Watts .6 ESP
Entering
Water Temp °F
Water fl ow
GPM
6.0 10.6 4.5
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT
°F DB / °F WB
Operation Not Recom-
mended
Total
KBtu/hr.
Capacity Kbtu/hr
Latent
Engineering Submittal Sheet
SHR Power kW EER
20
30
40
50
60
70
80
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
21 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
9.0 11.1 4.7
12.0 11.1 4.7
6.0 3.5 1.5
9.0 7.1 3.0
12.0 11.8 5.0
6.0 3.3 1.4
9.0 6.8 2.9
12.0 11.5 4.9
6.0 3.3 1.4
9.0 6.8 2.9
12.0 11.3 4.8
6.0 3.3 1.4
9.0 6.6 2.8
12.0 11.1 4.7
6.0 3.1 1.3
9.0 6.6 2.8
12.0 10.8 4.6
6.0 3.1 1.3
9.0 6.4 2.7
12.0 10.6 4.5
6.0 3.1 1.3
9.0 6.4 2.7
12.0 10.6 4.5
6.0 3.1 1.3
9.0 6.1 2.6
12.0 10.4 4.4
6.0 2.8 1.2
9.0 6.1 2.6
12.0 10.1 4.3
BTC 760108306 H | 12.2018
Operation Not Recommended
75/63 43.8 28.6 0.65 1.4 32.4
80.6/66.2 46.3 34.7 0.75 1.4 34.0
85/71 53.6 31.9 0.60 1.4 38.4
75/63 45.3 29.1 0.64 1.2 37.0
80.6/66.2 48.0 35.4 0.74 1.2 38.8
85/71 55.5 32.5 0.59 1.3 44.0
75/63 46.2 29.4 0.64 1.2 39.8
80.6/66.2 48.9 35.7 0.73 1.2 41.8
85/71 56.5 32.8 0.58 1.2 47.3
75/63 41.5 27.9 0.67 1.5 26.8
80.6/66.2 43.9 33.9 0.77 1.6 28.2
85/71 50.8 31.2 0.61 1.6 31.9
75/63 43.0 28.4 0.66 1.4 30.4
80.6/66.2 45.5 34.5 0.76 1.4 32.0
85/71 52.6 31.7 0.60 1.5 36.2
75/63 43.8 28.6 0.65 1.3 32.6
80.6/66.2 46.4 34.7 0.75 1.4 34.2
85/71 53.7 31.9 0.59 1.4 38.7
75/63 39.2 27.1 0.69 1.8 22.3
80.6/66.2 41.5 33.0 0.79 1.8 23.4
85/71 48.0 30.3 0.63 1.8 26.5
75/63 40.7 27.5 0.68 1.6 25.1
80.6/66.2 43.1 33.5 0.78 1.6 26.3
85/71 49.8 30.8 0.62 1.7 29.8
75/63 41.4 27.9 0.67 1.5 26.7
80.6/66.2 43.8 33.9 0.77 1.6 28.0
85/71 50.7 31.2 0.61 1.6 31.7
75/63 36.8 26.4 0.72 2.0 18.5
80.6/66.2 39.0 32.0 0.82 2.0 19.4
85/71 45.1 29.4 0.65 2.1 21.9
75/63 38.2 26.8 0.70 1.8 20.7
80.6/66.2 40.5 32.5 0.80 1.9 21.7
85/71 46.8 29.9 0.64 1.9 24.5
75/63 39.0 27.1 0.69 1.8 22.0
80.6/66.2 41.3 32.9 0.80 1.8 23.1
85/71 47.7 30.2 0.63 1.8 26.1
75/63 34.5 25.6 0.74 2.3 15.3
80.6/66.2 36.5 31.1 0.85 2.3 16.0
85/71 42.2 28.6 0.68 2.3 18.1
75/63 35.7 26.0 0.73 2.1 17.0
80.6/66.2 37.8 31.6 0.84 2.1 17.8
85/71 43.7 29.1 0.66 2.2 20.1
75/63 36.7 25.9 0.71 2.0 18.1
80.6/66.2 38.9 31.5 0.81 2.0 19.0
85/71 44.9 28.9 0.64 2.1 21.5
75/63 32.2 24.7 0.77 2.5 12.7
80.6/66.2 34.1 30.0 0.88 2.6 13.3
85/71 39.4 27.6 0.70 2.6 15.0
75/63 33.4 25.2 0.76 2.4 14.0
80.6/66.2 35.3 30.6 0.87 2.4 14.7
85/71 40.9 28.2 0.69 2.5 16.6
75/63 34.0 25.4 0.75 2.3 14.7
80.6/66.2 36.0 30.9 0.86 2.3 15.4
85/71 41.6 28.4 0.68 2.4 17.5
75/63 30.0 24.0 0.80 2.8 10.5
80.6/66.2 31.8 29.2 0.92 2.9 11.1
85/71 36.7 26.8 0.73 2.9 12.5
75/63 31.1 24.3 0.78 2.7 11.5
80.6/66.2 32.9 29.5 0.90 2.7 12.1
85/71 38.1 27.1 0.71 2.8 13.7
75/63 31.7 24.4 0.77 2.6 12.1
80.6/66.2 33.5 29.7 0.89 2.6 12.7
85/71 38.8 27.3 0.70 2.7 14.4
75/63 27.8 23.1 0.83 3.2 8.7
80.6/66.2 29.4 28.1 0.95 3.2 9.2
85/71 34.0 25.8 0.76 3.3 10.4
75/63 28.8 23.5 0.82 3.0 9.5
80.6/66.2 30.5 28.5 0.94 3.1 10.0
85/71 35.3 26.2 0.74 3.1 11.3
75/63 29.3 23.8 0.81 3.0 9.9
80.6/66.2 31.0 28.9 0.93 3.0 10.4
85/71 35.8 26.5 0.74 3.0 11.8
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 22
SM Series -
Residential Geothermal Heat Pumps
SM048 Partial Load Heating Performance Data - 1263 SCFM -294 Fan Watts .6 ESP
Entering
Water Temp °F
20
30
40
50
60
70
80
Water fl ow
GPM
6.0 10.6 4.5
9.0 11.1 4.7
12.0 11.1 4.7
6.0 3.5 1.5
9.0 7.1 3.0
12.0 11.8 5.0
6.0 3.3 1.4
9.0 6.8 2.9
12.0 11.5 4.9
6.0 3.3 1.4
9.0 6.8 2.9
12.0 11.3 4.8
6.0 3.3 1.4
9.0 6.6 2.8
12.0 11.1 4.7
6.0 3.1 1.3
9.0 6.6 2.8
12.0 10.8 4.6
6.0 3.1 1.3
9.0 6.4 2.7
12.0 10.6 4.5
6.0 3.1 1.3
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT °F DB
60 22.5 14.2 2.06 3.2
68 22.8 15.2 2.21 3.0
80 23.2 15.9 2.30 3.0
60 23.2 14.8 2.07 3.3
68 23.6 15.9 2.21 3.1
80 24.0 16.5 2.30 3.1
60 23.6 15.1 2.07 3.3
68 24.0 16.2 2.21 3.2
80 24.4 16.8 2.31 3.1
60 25.7 17.3 2.08 3.6
68 26.2 18.5 2.23 3.4
80 26.6 19.2 2.32 3.4
60 26.7 18.1 2.09 3.7
68 27.2 19.4 2.24 3.6
80 27.6 20.2 2.33 3.5
60 27.2 18.6 2.10 3.8
68 27.7 19.9 2.24 3.6
80 28.2 20.7 2.33 3.5
60 29.4 20.5 2.11 4.1
68 29.9 22.0 2.26 3.9
80 30.3 22.9 2.35 3.8
60 30.6 21.7 2.12 4.2
68 31.1 23.2 2.27 4.0
80 31.6 24.1 2.36 3.9
60 31.3 22.3 2.12 4.3
68 31.8 23.9 2.27 4.1
80 32.3 24.9 2.37 4.0
60 33.2 24.1 2.14 4.6
68 33.8 25.7 2.29 4.3
80 34.3 26.8 2.38 4.2
60 34.7 25.5 2.15 4.7
68 35.3 27.3 2.30 4.5
80 35.9 28.4 2.39 4.4
60 35.7 26.1 2.15 4.9
68 36.3 27.9 2.30 4.6
80 36.9 29.1 2.40 4.5
60 37.3 27.8 2.16 5.1
68 37.9 29.7 2.31 4.8
80 38.5 30.9 2.41 4.7
60 39.1 29.5 2.17 5.3
68 39.8 31.6 2.32 5.0
80 40.4 32.9 2.42 4.9
60 40.3 30.3 2.17 5.4
68 41.0 32.4 2.33 5.2
80 41.7 33.8 2.42 5.0
60 41.6 31.7 2.18 5.6
68 42.3 34.0 2.33 5.3
80 43.0 35.3 2.43 5.2
60 43.8 33.8 2.19 5.9
68 44.6 36.2 2.34 5.6
80 45.3 37.7 2.44 5.4
60 45.2 34.8 2.19 6.0
68 46.0 37.2 2.35 5.7
80 46.7 38.7 2.44 5.6
60 46.1 35.9 2.20 6.1
68 46.9 38.4 2.35 5.8
80 47.6 39.9 2.45 5.7
60 48.7 38.3 2.21 6.5
68 49.5 41.0 2.37 6.1
80 50.3 42.7 2.46 6.0
60 50.2 39.6 2.22 6.6
68 51.1 42.4 2.37 6.3
80 51.9 44.1 2.47 6.2
Total
KBtu/hr.
Engineering Submittal Sheet
Heat of Absp
kBtu/hr
Power kW COP
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
22 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
9.0 6.4 2.7
12.0 10.6 4.5
6.0 3.1 1.3
9.0 6.1 2.6
12.0 10.4 4.4
6.0 2.8 1.2
9.0 6.1 2.6
12.0 10.1 4.3
BTC 760108306 H | 12.2018
Operation Not Recommended
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 23
SM Series -
Residential Geothermal Heat Pumps
SM060 Full Load Cooling Performance Data - 1950 SCFM -592 Fan Watts .6 ESP
Entering
Water Temp °F
Water fl ow
GPM
7.0 4.2 1.8
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT
°F DB / °F WB
Operation Not Recom-
mended
Total
KBtu/hr.
Latent
Capacity Kbtu/hr
Engineering Submittal Sheet
SHR Power kW EER
20
30
40
50
60
70
80
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
23 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
12.0 10.8 4.6
15.0 16.0 6.8
7.0 4.0 1.7
12.0 10.4 4.4
15.0 15.6 6.6
7.0 4.0 1.7
12.0 10.1 4.3
15.0 15.3 6.5
7.0 3.8 1.6
12.0 10.1 4.3
15.0 14.8 6.3
7.0 3.8 1.6
12.0 9.9 4.2
15.0 14.6 6.2
7.0 3.8 1.6
12.0 9.7 4.1
15.0 14.4 6.1
7.0 3.5 1.5
12.0 9.4 4.0
15.0 14.1 6.0
7.0 3.5 1.5
12.0 9.2 3.9
15.0 13.9 5.9
7.0 3.5 1.5
12.0 9.2 3.9
15.0 13.4 5.7
7.0 3.3 1.4
12.0 9.0 3.8
15.0 13.2 5.6
BTC 760108306 H | 12.2018
Operation Not Recommended
75/63 66.6 44.3 0.66 3.2 20.8
80.6/66.2 70.5 53.8 0.76 3.2 21.9
85/71 81.5 49.4 0.61 3.3 24.7
75/63 69.4 45.3 0.65 3.0 23.4
80.6/66.2 73.5 55.1 0.75 3.0 24.6
85/71 85.0 50.6 0.60 3.1 27.8
75/63 70.2 45.6 0.65 2.9 24.2
80.6/66.2 74.3 55.4 0.75 2.9 25.4
85/71 85.9 50.9 0.59 3.0 28.8
75/63 64.1 43.3 0.68 2.9 22.1
80.6/66.2 67.8 52.7 0.78 2.9 23.2
85/71 78.5 48.4 0.62 3.0 26.2
75/63 66.8 44.4 0.66 3.4 19.5
80.6/66.2 70.8 53.9 0.76 3.5 20.4
85/71 81.8 49.6 0.61 3.5 23.1
75/63 67.6 44.7 0.66 3.2 21.3
80.6/66.2 71.6 54.3 0.76 3.2 22.4
85/71 82.8 49.9 0.60 3.3 25.3
75/63 61.5 42.4 0.69 3.1 19.8
80.6/66.2 65.1 51.5 0.79 3.1 20.8
85/71 75.3 47.3 0.63 3.2 23.5
75/63 64.2 43.3 0.68 3.7 17.3
80.6/66.2 68.0 52.7 0.77 3.7 18.1
85/71 78.6 48.4 0.62 3.8 20.5
75/63 65.0 43.6 0.67 3.4 19.0
80.6/66.2 68.8 53.0 0.77 3.5 19.9
85/71 79.5 48.7 0.61 3.5 22.5
75/63 59.0 41.1 0.70 3.3 17.6
80.6/66.2 62.4 50.0 0.80 3.4 18.5
85/71 72.2 45.9 0.64 3.5 20.9
75/63 61.5 42.2 0.69 4.0 15.2
80.6/66.2 65.2 51.3 0.79 4.1 16.0
85/71 75.4 47.1 0.63 4.2 18.1
75/63 62.3 42.5 0.68 3.7 16.8
80.6/66.2 65.9 51.6 0.78 3.8 17.6
85/71 76.2 47.4 0.62 3.8 19.9
75/63 56.1 40.4 0.72 3.6 15.4
80.6/66.2 59.4 49.1 0.83 3.7 16.2
85/71 68.7 45.1 0.66 3.7 18.3
75/63 58.8 41.1 0.70 4.4 13.3
80.6/66.2 62.2 49.9 0.80 4.4 14.0
85/71 71.9 45.9 0.64 4.5 15.8
75/63 59.4 41.3 0.70 4.1 14.6
80.6/66.2 62.9 50.2 0.80 4.1 15.4
85/71 72.8 46.2 0.63 4.2 17.4
75/63 53.5 39.2 0.73 4.0 13.5
80.6/66.2 56.6 47.6 0.84 4.0 14.1
85/71 65.5 43.7 0.67 4.1 16.0
75/63 55.9 40.0 0.72 4.8 11.6
80.6/66.2 59.2 48.6 0.82 4.9 12.1
85/71 68.4 44.7 0.65 5.0 13.7
75/63 56.5 40.2 0.71 4.5 12.7
80.6/66.2 59.8 48.9 0.82 4.5 13.3
85/71 69.2 44.9 0.65 4.6 15.0
75/63 50.5 38.4 0.76 4.4 11.6
80.6/66.2 53.5 46.7 0.87 4.4 12.1
85/71 61.9 42.9 0.69 4.5 13.7
75/63 52.9 39.0 0.74 5.3 10.0
80.6/66.2 56.0 47.4 0.85 5.4 10.5
85/71 64.8 43.5 0.67 5.5 11.8
75/63 53.5 39.1 0.73 4.9 10.9
80.6/66.2 56.6 47.6 0.84 5.0 11.4
85/71 65.5 43.7 0.67 5.1 12.9
75/63 47.7 37.5 0.79 4.8 9.9
80.6/66.2 50.5 45.5 0.90 4.9 10.4
85/71 58.4 41.8 0.72 5.0 11.7
75/63 49.7 38.1 0.77 5.8 8.5
80.6/66.2 52.6 46.3 0.88 5.9 8.9
85/71 60.8 42.6 0.70 6.0 10.1
75/63 50.3 38.3 0.76 5.5 9.2
80.6/66.2 53.2 46.5 0.87 5.5 9.7
85/71 61.5 42.7 0.69 5.6 10.9
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 24
SM Series -
Residential Geothermal Heat Pumps
SM060 Full Load Heating Performance Data - 1950 SCFM -592 Fan Watts .6 ESP
Entering
Water Temp °F
20
30
40
50
60
70
80
Water fl ow
GPM
7.0 4.2 1.8
12.0 10.8 4.6
15.0 16.0 6.8
7.0 4.0 1.7
12.0 10.4 4.4
15.0 15.6 6.6
7.0 4.0 1.7
12.0 10.1 4.3
15.0 15.3 6.5
7.0 3.8 1.6
12.0 10.1 4.3
15.0 14.8 6.3
7.0 3.8 1.6
12.0 9.9 4.2
15.0 14.6 6.2
7.0 3.8 1.6
12.0 9.7 4.1
15.0 14.4 6.1
7.0 3.5 1.5
12.0 9.4 4.0
15.0 14.1 6.0
7.0 3.5 1.5
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT °F DB
60 39.6 25.0 3.34 3.5
68 40.3 26.8 3.57 3.3
80 40.9 27.9 3.72 3.2
60 41.8 26.9 3.38 3.6
68 42.6 28.7 3.62 3.4
80 43.2 29.9 3.77 3.4
60 42.6 27.3 3.40 3.7
68 43.3 29.2 3.64 3.5
80 44.0 30.4 3.78 3.4
60 44.8 29.3 3.45 3.8
68 45.6 31.4 3.69 3.6
80 46.3 32.7 3.84 3.5
60 47.6 31.7 3.51 4.0
68 48.5 34.0 3.75 3.8
80 49.2 35.3 3.91 3.7
60 48.6 32.5 3.53 4.0
68 49.4 34.8 3.78 3.8
80 50.2 36.2 3.93 3.7
60 50.4 34.0 3.57 4.1
68 51.3 36.4 3.82 3.9
80 52.1 37.9 3.98 3.8
60 54.0 37.1 3.64 4.4
68 55.0 39.7 3.90 4.1
80 55.8 41.4 4.05 4.0
60 55.3 38.0 3.66 4.4
68 56.3 40.6 3.92 4.2
80 57.2 42.3 4.08 4.1
60 56.7 39.3 3.69 4.5
68 57.6 42.0 3.95 4.3
80 58.6 43.8 4.11 4.2
60 61.4 42.9 3.78 4.8
68 62.4 45.9 4.04 4.5
80 63.4 47.8 4.21 4.4
60 62.4 44.3 3.81 4.8
68 63.5 47.4 4.07 4.6
80 64.5 49.3 4.24 4.5
60 63.4 45.0 3.82 4.9
68 64.5 48.1 4.09 4.6
80 65.5 50.1 4.26 4.5
60 68.4 49.1 3.93 5.1
68 69.6 52.5 4.20 4.9
80 70.7 54.7 4.38 4.7
60 70.2 50.5 3.96 5.2
68 71.4 54.0 4.24 4.9
80 72.5 56.2 4.42 4.8
60 70.5 50.9 3.97 5.2
68 71.7 54.4 4.25 4.9
80 72.8 56.7 4.42 4.8
60 76.5 56.0 4.10 5.5
68 77.8 59.9 4.39 5.2
80 79.0 62.3 4.57 5.1
60 78.4 57.6 4.14 5.5
68 79.8 61.7 4.43 5.3
80 81.0 64.2 4.62 5.1
60 77.7 57.0 4.13 5.5
68 79.1 61.0 4.42 5.2
80 80.3 63.5 4.60 5.1
60 84.7 62.8 4.28 5.8
68 86.1 67.2 4.59 5.5
80 87.5 70.0 4.77 5.4
60 86.9 64.7 4.34 5.9
68 88.4 69.2 4.64 5.6
80 89.8 72.1 4.83 5.4
Total
KBtu/hr.
Engineering Submittal Sheet
Heat of Absp
kBtu/hr
Power kW COP
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
24 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
12.0 9.2 3.9
15.0 13.9 5.9
7.0 3.5 1.5
12.0 9.2 3.9
15.0 13.4 5.7
7.0 3.3 1.4
12.0 9.0 3.8
15.0 13.2 5.6
BTC 760108306 H | 12.2018
Operation Not Recommended
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 25
SM Series -
Residential Geothermal Heat Pumps
SM060 Partial Load Cooling Performance Data - 1571 SCFM -395 Fan Watts .6 ESP
Entering
Water Temp °F
Water fl ow
GPM
7.0 4.2 1.8
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT
°F DB / °F WB
Operation Not Recom-
mended
Total
KBtu/hr.
Capacity Kbtu/hr
Latent
Engineering Submittal Sheet
SHR Power kW EER
20
30
40
50
60
70
80
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
25 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
12.0 10.8 4.6
15.0 16.0 6.8
7.0 4.0 1.7
12.0 10.4 4.4
15.0 15.6 6.6
7.0 4.0 1.7
12.0 10.4 4.4
15.0 15.3 6.5
7.0 3.8 1.6
12.0 10.1 4.3
15.0 15.1 6.4
7.0 3.8 1.6
12.0 9.7 4.1
15.0 14.4 6.1
7.0 3.5 1.5
12.0 9.4 4.0
15.0 14.1 6.0
7.0 3.5 1.5
12.0 9.2 3.9
15.0 13.9 5.9
7.0 3.5 1.5
12.0 9.2 3.9
15.0 13.7 5.8
7.0 3.3 1.4
12.0 9.0 3.8
15.0 13.2 5.6
7.0 3.3 1.4
12.0 9.0 3.8
15.0 13.2 5.6
BTC 760108306 H | 12.2018
Operation Not Recommended
75/63 51.9 35.7 0.69 1.8 29.6
80.6/66.2 55.0 43.4 0.79 1.8 31.0
85/71 63.6 39.9 0.63 1.8 35.1
75/63 54.2 36.5 0.67 1.6 34.1
80.6/66.2 57.4 44.4 0.77 1.6 35.8
85/71 66.3 40.8 0.61 1.6 40.5
75/63 54.8 36.7 0.67 1.5 35.6
80.6/66.2 58.0 44.6 0.77 1.6 37.3
85/71 67.1 41.0 0.61 1.6 42.2
75/63 49.4 34.7 0.70 2.0 25.0
80.6/66.2 52.3 42.2 0.81 2.0 26.2
85/71 60.4 38.8 0.64 2.0 29.7
75/63 51.6 35.4 0.69 1.8 28.8
80.6/66.2 54.6 43.0 0.79 1.8 30.2
85/71 63.1 39.6 0.63 1.8 34.2
75/63 52.2 35.7 0.68 1.7 30.0
80.6/66.2 55.3 43.3 0.78 1.8 31.5
85/71 63.9 39.8 0.62 1.8 35.7
75/63 46.8 33.6 0.72 2.2 21.1
80.6/66.2 49.5 40.9 0.83 2.2 22.1
85/71 57.3 37.6 0.66 2.3 25.0
75/63 48.8 33.5 0.69 2.0 24.1
80.6/66.2 51.7 40.8 0.79 2.0 25.3
85/71 59.8 37.5 0.63 2.1 28.7
75/63 49.4 33.7 0.68 2.0 25.1
80.6/66.2 52.3 41.0 0.78 2.0 26.4
85/71 60.5 37.7 0.62 2.0 29.8
75/63 44.1 31.9 0.72 2.5 17.6
80.6/66.2 46.7 38.8 0.83 2.5 18.5
85/71 54.0 35.6 0.66 2.6 20.9
75/63 46.0 32.5 0.71 2.3 20.1
80.6/66.2 48.7 39.5 0.81 2.3 21.1
85/71 56.4 36.3 0.64 2.4 23.9
75/63 46.6 32.7 0.70 2.2 20.9
80.6/66.2 49.3 39.7 0.81 2.3 21.9
85/71 57.1 36.5 0.64 2.3 24.8
75/63 41.3 30.7 0.74 2.8 14.7
80.6/66.2 43.7 37.3 0.85 2.8 15.4
85/71 50.5 34.3 0.68 2.9 17.4
75/63 43.2 31.5 0.73 2.6 16.6
80.6/66.2 45.7 38.3 0.84 2.6 17.5
85/71 52.9 35.2 0.67 2.7 19.8
75/63 43.7 31.7 0.73 2.5 17.3
80.6/66.2 46.3 38.5 0.83 2.6 18.1
85/71 53.5 35.4 0.66 2.6 20.5
75/63 38.6 29.9 0.78 3.2 12.2
80.6/66.2 40.9 36.4 0.89 3.2 12.8
85/71 47.3 33.4 0.71 3.3 14.5
75/63 40.3 30.5 0.76 2.9 13.7
80.6/66.2 42.6 37.0 0.87 3.0 14.4
85/71 49.3 34.0 0.69 3.0 16.3
75/63 40.8 30.6 0.75 2.9 14.2
80.6/66.2 43.2 37.2 0.86 2.9 14.9
85/71 49.9 34.2 0.69 3.0 16.8
75/63 35.9 29.0 0.81 3.5 10.1
80.6/66.2 38.0 35.2 0.93 3.6 10.6
85/71 43.9 32.3 0.74 3.7 12.0
75/63 37.4 29.5 0.79 3.3 11.3
80.6/66.2 39.6 35.8 0.90 3.4 11.8
85/71 45.8 32.9 0.72 3.4 13.4
75/63 37.9 29.6 0.78 3.3 11.6
80.6/66.2 40.1 36.0 0.90 3.3 12.2
85/71 46.4 33.1 0.71 3.4 13.8
75/63 47.7 37.5 0.79 4.8 9.9
80.6/66.2 50.5 45.5 0.90 4.9 10.4
85/71 58.4 41.8 0.72 5.0 11.7
75/63 49.7 38.1 0.77 5.8 8.5
80.6/66.2 52.6 46.3 0.88 5.9 8.9
85/71 60.8 42.6 0.70 6.0 10.1
75/63 50.3 38.3 0.76 5.5 9.2
80.6/66.2 53.2 46.5 0.87 5.5 9.7
85/71 61.5 42.7 0.69 5.6 10.9
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 26
SM Series -
Residential Geothermal Heat Pumps
SM060 Partial Load Heating Performance Data - 1571 SCFM -395 Fan Watts .6 ESP
Entering
Water Temp °F
20
30
40
50
60
70
80
Water fl ow
GPM
7.0 4.2 1.8
12.0 10.8 4.6
15.0 16.0 6.8
7.0 4.0 1.7
12.0 10.4 4.4
15.0 15.6 6.6
7.0 4.0 1.7
12.0 10.4 4.4
15.0 15.3 6.5
7.0 3.8 1.6
12.0 10.1 4.3
15.0 15.1 6.4
7.0 3.8 1.6
12.0 9.7 4.1
15.0 14.4 6.1
7.0 3.5 1.5
12.0 9.4 4.0
15.0 14.1 6.0
7.0 3.5 1.5
12.0 9.2 3.9
15.0 13.9 5.9
7.0 3.5 1.5
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT °F DB
60 28.3 17.7 2.46 3.4
68 28.8 19.0 2.63 3.2
80 29.3 19.7 2.74 3.1
60 29.6 18.9 2.47 3.5
68 30.2 20.2 2.64 3.3
80 30.6 21.0 2.75 3.3
60 30.1 19.2 2.47 3.6
68 30.6 20.6 2.64 3.4
80 31.1 21.4 2.75 3.3
60 32.6 21.4 2.49 3.8
68 33.2 22.9 2.67 3.6
80 33.7 23.8 2.78 3.6
60 34.1 23.0 2.51 4.0
68 34.7 24.6 2.68 3.8
80 35.3 25.6 2.79 3.7
60 34.7 23.4 2.51 4.1
68 35.3 25.0 2.69 3.9
80 35.9 26.1 2.80 3.8
60 37.3 25.5 2.53 4.3
68 38.0 27.3 2.71 4.1
80 38.5 28.4 2.82 4.0
60 39.3 27.3 2.55 4.5
68 40.0 29.2 2.73 4.3
80 40.6 30.4 2.84 4.2
60 39.9 27.8 2.56 4.6
68 40.6 29.8 2.74 4.3
80 41.3 31.0 2.85 4.2
60 42.3 30.3 2.58 4.8
68 43.0 32.4 2.77 4.6
80 43.7 33.7 2.88 4.4
60 44.7 32.1 2.61 5.0
68 45.5 34.4 2.79 4.8
80 46.2 35.8 2.90 4.7
60 45.5 32.8 2.61 5.1
68 46.3 35.1 2.80 4.9
80 47.0 36.6 2.91 4.7
60 47.5 34.6 2.63 5.3
68 48.3 37.0 2.81 5.0
80 49.1 38.5 2.92 4.9
60 50.5 37.3 2.64 5.6
68 51.4 40.0 2.83 5.3
80 52.2 41.6 2.95 5.2
60 51.5 38.2 2.65 5.7
68 52.4 40.9 2.84 5.4
80 53.2 42.6 2.95 5.3
60 53.0 39.5 2.66 5.8
68 53.9 42.3 2.84 5.5
80 54.7 44.0 2.96 5.4
60 56.5 42.8 2.68 6.2
68 57.5 45.8 2.87 5.9
80 58.4 47.7 2.98 5.7
60 57.7 43.8 2.69 6.3
68 58.7 46.9 2.87 6.0
80 59.6 48.8 2.99 5.8
60 58.6 44.6 2.69 6.4
68 59.6 47.7 2.88 6.1
80 60.5 49.7 3.00 5.9
60 62.7 48.4 2.71 6.8
68 63.8 51.8 2.90 6.4
80 64.8 53.9 3.02 6.3
60 64.0 49.6 2.72 6.9
68 65.1 53.1 2.91 6.6
80 66.2 55.2 3.03 6.4
Total
KBtu/hr.
Engineering Submittal Sheet
Heat of Absp
kBtu/hr
Power kW COP
90
100
12.0 9.2 3.9
15.0 13.7 5.8
7.0 3.3 1.4
12.0 9.0 3.8
Operation Not Recommended
15.0 13.2 5.6
7.0 3.3 1.4
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
26 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
12.0 9.0 3.8
15.0 13.2 5.6
BTC 760108306 H | 12.2018
Bosch Thermotechnology Corp.
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 27
SM Series -
Residential Geothermal Heat Pumps
SM070 Full Load Cooling Performance Data - 2230 SCFM -799 Fan Watts .6 ESP
Entering
Water Temp °F
Water fl ow
GPM
9.0 6.6 2.8
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT
°F DB / °F WB
Operation Not Recom-
mended
Total
KBtu/hr.
Latent
Capacity Kbtu/hr
Engineering Submittal Sheet
SHR Power kW EER
20
30
40
50
60
70
80
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
27 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
12.0 10.8 4.6
18.0 22.2 9.4
9.0 6.1 2.6
15.0 15.6 6.6
18.0 21.4 9.1
9.0 6.1 2.6
15.0 15.3 6.5
18.0 21.0 8.9
9.0 5.9 2.5
15.0 14.8 6.3
18.0 20.7 8.8
9.0 5.9 2.5
15.0 14.6 6.2
18.0 20.3 8.6
9.0 5.7 2.4
15.0 14.4 6.1
18.0 19.8 8.4
9.0 5.7 2.4
15.0 14.1 6.0
18.0 19.6 8.3
9.0 5.4 2.3
15.0 13.7 5.8
18.0 19.1 8.1
9.0 5.4 2.3
15.0 13.4 5.7
18.0 18.6 7.9
9.0 5.2 2.2
15.0 13.2 5.6
18.0 18.4 7.8
BTC 760108306 H | 12.2018
Operation Not Recommended
75/63 66.6 44.3 0.66 3.2 20.8
80.6/66.2 70.5 53.8 0.76 3.2 21.9
85/71 81.5 49.4 0.61 3.3 24.7
75/63 69.4 45.3 0.65 3.0 23.4
80.6/66.2 73.5 55.1 0.75 3.0 24.6
85/71 85.0 50.6 0.60 3.1 27.8
75/63 70.2 45.6 0.65 2.9 24.2
80.6/66.2 74.3 55.4 0.75 2.9 25.4
85/71 85.9 50.9 0.59 3.0 28.8
75/63 64.1 43.3 0.68 2.9 22.1
80.6/66.2 67.8 52.7 0.78 2.9 23.2
85/71 78.5 48.4 0.62 3.0 26.2
75/63 66.8 44.4 0.66 3.4 19.5
80.6/66.2 70.8 53.9 0.76 3.5 20.4
85/71 81.8 49.6 0.61 3.5 23.1
75/63 67.6 44.7 0.66 3.2 21.3
80.6/66.2 71.6 54.3 0.76 3.2 22.4
85/71 82.8 49.9 0.60 3.3 25.3
75/63 61.5 42.4 0.69 3.1 19.8
80.6/66.2 65.1 51.5 0.79 3.1 20.8
85/71 75.3 47.3 0.63 3.2 23.5
75/63 64.2 43.3 0.68 3.7 17.3
80.6/66.2 68.0 52.7 0.77 3.7 18.1
85/71 78.6 48.4 0.62 3.8 20.5
75/63 65.0 43.6 0.67 3.4 19.0
80.6/66.2 68.8 53.0 0.77 3.5 19.9
85/71 79.5 48.7 0.61 3.5 22.5
75/63 59.0 41.1 0.70 3.3 17.6
80.6/66.2 62.4 50.0 0.80 3.4 18.5
85/71 72.2 45.9 0.64 3.5 20.9
75/63 61.5 42.2 0.69 4.0 15.2
80.6/66.2 65.2 51.3 0.79 4.1 16.0
85/71 75.4 47.1 0.63 4.2 18.1
75/63 62.3 42.5 0.68 3.7 16.8
80.6/66.2 65.9 51.6 0.78 3.8 17.6
85/71 76.2 47.4 0.62 3.8 19.9
75/63 56.1 40.4 0.72 3.6 15.4
80.6/66.2 59.4 49.1 0.83 3.7 16.2
85/71 68.7 45.1 0.66 3.7 18.3
75/63 58.8 41.1 0.70 4.4 13.3
80.6/66.2 62.2 49.9 0.80 4.4 14.0
85/71 71.9 45.9 0.64 4.5 15.8
75/63 59.4 41.3 0.70 4.1 14.6
80.6/66.2 62.9 50.2 0.80 4.1 15.4
85/71 72.8 46.2 0.63 4.2 17.4
75/63 53.5 39.2 0.73 4.0 13.5
80.6/66.2 56.6 47.6 0.84 4.0 14.1
85/71 65.5 43.7 0.67 4.1 16.0
75/63 55.9 40.0 0.72 4.8 11.6
80.6/66.2 59.2 48.6 0.82 4.9 12.1
85/71 68.4 44.7 0.65 5.0 13.7
75/63 56.5 40.2 0.71 4.5 12.7
80.6/66.2 59.8 48.9 0.82 4.5 13.3
85/71 69.2 44.9 0.65 4.6 15.0
75/63 50.5 38.4 0.76 4.4 11.6
80.6/66.2 53.5 46.7 0.87 4.4 12.1
85/71 61.9 42.9 0.69 4.5 13.7
75/63 52.9 39.0 0.74 5.3 10.0
80.6/66.2 56.0 47.4 0.85 5.4 10.5
85/71 64.8 43.5 0.67 5.5 11.8
75/63 53.5 39.1 0.73 4.9 10.9
80.6/66.2 56.6 47.6 0.84 5.0 11.4
85/71 65.5 43.7 0.67 5.1 12.9
75/63 47.7 37.5 0.79 4.8 9.9
80.6/66.2 50.5 45.5 0.90 4.9 10.4
85/71 58.4 41.8 0.72 5.0 11.7
75/63 49.7 38.1 0.77 5.8 8.5
80.6/66.2 52.6 46.3 0.88 5.9 8.9
85/71 60.8 42.6 0.70 6.0 10.1
75/63 50.3 38.3 0.76 5.5 9.2
80.6/66.2 53.2 46.5 0.87 5.5 9.7
85/71 61.5 42.7 0.69 5.6 10.9
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 28
SM Series -
Residential Geothermal Heat Pumps
SM070 Full Load Heating Performance Data - 2230 SCFM -799 Fan Watts .6 ESP
Entering
Water Temp °F
20
30
40
50
60
70
80
Water fl ow
GPM
9.0 6.6 2.8
12.0 10.8 4.6
18.0 22.2 9.4
9.0 6.1 2.6
15.0 15.6 6.6
18.0 21.4 9.1
9.0 6.1 2.6
15.0 15.3 6.5
18.0 21.0 8.9
9.0 5.9 2.5
15.0 14.8 6.3
18.0 20.7 8.8
9.0 5.9 2.5
15.0 14.6 6.2
18.0 20.3 8.6
9.0 5.7 2.4
15.0 14.4 6.1
18.0 19.8 8.4
9.0 5.7 2.4
15.0 14.1 6.0
18.0 19.6 8.3
9.0 5.4 2.3
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT °F DB
60 39.6 25.0 3.34 3.5
68 40.3 26.8 3.57 3.3
80 40.9 27.9 3.72 3.2
60 41.8 26.9 3.38 3.6
68 42.6 28.7 3.62 3.4
80 43.2 29.9 3.77 3.4
60 42.6 27.3 3.40 3.7
68 43.3 29.2 3.64 3.5
80 44.0 30.4 3.78 3.4
60 44.8 29.3 3.45 3.8
68 45.6 31.4 3.69 3.6
80 46.3 32.7 3.84 3.5
60 47.6 31.7 3.51 4.0
68 48.5 34.0 3.75 3.8
80 49.2 35.3 3.91 3.7
60 48.6 32.5 3.53 4.0
68 49.4 34.8 3.78 3.8
80 50.2 36.2 3.93 3.7
60 50.4 34.0 3.57 4.1
68 51.3 36.4 3.82 3.9
80 52.1 37.9 3.98 3.8
60 54.0 37.1 3.64 4.4
68 55.0 39.7 3.90 4.1
80 55.8 41.4 4.05 4.0
60 55.3 38.0 3.66 4.4
68 56.3 40.6 3.92 4.2
80 57.2 42.3 4.08 4.1
60 56.7 39.3 3.69 4.5
68 57.6 42.0 3.95 4.3
80 58.6 43.8 4.11 4.2
60 61.4 42.9 3.78 4.8
68 62.4 45.9 4.04 4.5
80 63.4 47.8 4.21 4.4
60 62.4 44.3 3.81 4.8
68 63.5 47.4 4.07 4.6
80 64.5 49.3 4.24 4.5
60 63.4 45.0 3.82 4.9
68 64.5 48.1 4.09 4.6
80 65.5 50.1 4.26 4.5
60 68.4 49.1 3.93 5.1
68 69.6 52.5 4.20 4.9
80 70.7 54.7 4.38 4.7
60 70.2 50.5 3.96 5.2
68 71.4 54.0 4.24 4.9
80 72.5 56.2 4.42 4.8
60 70.5 50.9 3.97 5.2
68 71.7 54.4 4.25 4.9
80 72.8 56.7 4.42 4.8
60 76.5 56.0 4.10 5.5
68 77.8 59.9 4.39 5.2
80 79.0 62.3 4.57 5.1
60 78.4 57.6 4.14 5.5
68 79.8 61.7 4.43 5.3
80 81.0 64.2 4.62 5.1
60 77.7 57.0 4.13 5.5
68 79.1 61.0 4.42 5.2
80 80.3 63.5 4.60 5.1
60 84.7 62.8 4.28 5.8
68 86.1 67.2 4.59 5.5
80 87.5 70.0 4.77 5.4
60 86.9 64.7 4.34 5.9
68 88.4 69.2 4.64 5.6
80 89.8 72.1 4.83 5.4
Total
KBtu/hr.
Engineering Submittal Sheet
Heat of Absp
kBtu/hr
Power kW COP
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
28 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
15.0 13.7 5.8
18.0 19.1 8.1
9.0 5.4 2.3
15.0 13.4 5.7
18.0 18.6 7.9
9.0 5.2 2.2
15.0 13.2 5.6
18.0 18.4 7.8
BTC 760108306 H | 12.2018
Operation Not Recommended
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 29
SM Series -
Residential Geothermal Heat Pumps
SM070 Partial Load Cooling Performance Data - 1770 SCFM -516 Fan Watts .6 ESP
Entering
Water Temp °F
Water fl ow
GPM
9.0 6.6 2.8
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT
°F DB / °F WB
Operation Not Recom-
mended
Total
KBtu/hr.
Capacity Kbtu/hr
Latent
Engineering Submittal Sheet
SHR Power kW EER
20
30
40
50
60
70
80
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
29 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
12.0 10.8 4.6
18.0 22.2 9.4
9.0 6.1 2.6
15.0 15.6 6.6
18.0 21.4 9.1
9.0 6.1 2.6
15.0 15.3 6.5
18.0 21.0 8.9
9.0 5.9 2.5
15.0 14.8 6.3
18.0 20.7 8.8
9.0 5.9 2.5
15.0 14.6 6.2
18.0 20.3 8.6
9.0 5.7 2.4
15.0 14.4 6.1
18.0 19.8 8.4
9.0 5.7 2.4
15.0 14.1 6.0
18.0 19.6 8.3
9.0 5.4 2.3
15.0 13.7 5.8
18.0 19.1 8.1
9.0 5.4 2.3
15.0 13.4 5.7
18.0 18.6 7.9
9.0 5.2 2.2
15.0 13.2 5.6
18.0 18.4 7.8
BTC 760108306 H | 12.2018
Operation Not Recommended
75/63 51.9 35.7 0.69 1.8 29.6
80.6/66.2 55.0 43.4 0.79 1.8 31.0
85/71 63.6 39.9 0.63 1.8 35.1
75/63 54.2 36.5 0.67 1.6 34.1
80.6/66.2 57.4 44.4 0.77 1.6 35.8
85/71 66.3 40.8 0.61 1.6 40.5
75/63 54.8 36.7 0.67 1.5 35.6
80.6/66.2 58.0 44.6 0.77 1.6 37.3
85/71 67.1 41.0 0.61 1.6 42.2
75/63 49.4 34.7 0.70 2.0 25.0
80.6/66.2 52.3 42.2 0.81 2.0 26.2
85/71 60.4 38.8 0.64 2.0 29.7
75/63 51.6 35.4 0.69 1.8 28.8
80.6/66.2 54.6 43.0 0.79 1.8 30.2
85/71 63.1 39.6 0.63 1.8 34.2
75/63 52.2 35.7 0.68 1.7 30.0
80.6/66.2 55.3 43.3 0.78 1.8 31.5
85/71 63.9 39.8 0.62 1.8 35.7
75/63 46.8 33.6 0.72 2.2 21.1
80.6/66.2 49.5 40.9 0.83 2.2 22.1
85/71 57.3 37.6 0.66 2.3 25.0
75/63 48.8 33.5 0.69 2.0 24.1
80.6/66.2 51.7 40.8 0.79 2.0 25.3
85/71 59.8 37.5 0.63 2.1 28.7
75/63 49.4 33.7 0.68 2.0 25.1
80.6/66.2 52.3 41.0 0.78 2.0 26.4
85/71 60.5 37.7 0.62 2.0 29.8
75/63 44.1 31.9 0.72 2.5 17.6
80.6/66.2 46.7 38.8 0.83 2.5 18.5
85/71 54.0 35.6 0.66 2.6 20.9
75/63 46.0 32.5 0.71 2.3 20.1
80.6/66.2 48.7 39.5 0.81 2.3 21.1
85/71 56.4 36.3 0.64 2.4 23.9
75/63 46.6 32.7 0.70 2.2 20.9
80.6/66.2 49.3 39.7 0.81 2.3 21.9
85/71 57.1 36.5 0.64 2.3 24.8
75/63 41.3 30.7 0.74 2.8 14.7
80.6/66.2 43.7 37.3 0.85 2.8 15.4
85/71 50.5 34.3 0.68 2.9 17.4
75/63 43.2 31.5 0.73 2.6 16.6
80.6/66.2 45.7 38.3 0.84 2.6 17.5
85/71 52.9 35.2 0.67 2.7 19.8
75/63 43.7 31.7 0.73 2.5 17.3
80.6/66.2 46.3 38.5 0.83 2.6 18.1
85/71 53.5 35.4 0.66 2.6 20.5
75/63 38.6 29.9 0.78 3.2 12.2
80.6/66.2 40.9 36.4 0.89 3.2 12.8
85/71 47.3 33.4 0.71 3.3 14.5
75/63 40.3 30.5 0.76 2.9 13.7
80.6/66.2 42.6 37.0 0.87 3.0 14.4
85/71 49.3 34.0 0.69 3.0 16.3
75/63 40.8 30.6 0.75 2.9 14.2
80.6/66.2 43.2 37.2 0.86 2.9 14.9
85/71 49.9 34.2 0.69 3.0 16.8
75/63 35.9 29.0 0.81 3.5 10.1
80.6/66.2 38.0 35.2 0.93 3.6 10.6
85/71 43.9 32.3 0.74 3.7 12.0
75/63 37.4 29.5 0.79 3.3 11.3
80.6/66.2 39.6 35.8 0.90 3.4 11.8
85/71 45.8 32.9 0.72 3.4 13.4
75/63 37.9 29.6 0.78 3.3 11.6
80.6/66.2 40.1 36.0 0.90 3.3 12.2
85/71 46.4 33.1 0.71 3.4 13.8
75/63 47.7 37.5 0.79 4.8 9.9
80.6/66.2 50.5 45.5 0.90 4.9 10.4
85/71 58.4 41.8 0.72 5.0 11.7
75/63 49.7 38.1 0.77 5.8 8.5
80.6/66.2 52.6 46.3 0.88 5.9 8.9
85/71 60.8 42.6 0.70 6.0 10.1
75/63 50.3 38.3 0.76 5.5 9.2
80.6/66.2 53.2 46.5 0.87 5.5 9.7
85/71 61.5 42.7 0.69 5.6 10.9
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 30
SM Series -
Residential Geothermal Heat Pumps
SM070 Partial Load Heating Performance Data - 1770 SCFM -516 Fan Watts .6 ESP
Entering
Water Temp °F
20
30
40
50
60
70
80
Water fl ow
GPM
9.0 6.6 2.8
12.0 10.8 4.6
18.0 22.2 9.4
9.0 6.1 2.6
15.0 15.6 6.6
18.0 21.4 9.1
9.0 6.1 2.6
15.0 15.3 6.5
18.0 21.0 8.9
9.0 5.9 2.5
15.0 14.8 6.3
18.0 20.7 8.8
9.0 5.9 2.5
15.0 14.6 6.2
18.0 20.3 8.6
9.0 5.7 2.4
15.0 14.4 6.1
18.0 19.8 8.4
9.0 5.7 2.4
15.0 14.1 6.0
18.0 19.6 8.3
9.0 5.4 2.3
Pressure Drop
(FOH)
Pressure Drop
(PSI)
EAT °F DB
60 28.3 17.7 2.46 3.4
68 28.8 19.0 2.63 3.2
80 29.3 19.7 2.74 3.1
60 29.6 18.9 2.47 3.5
68 30.2 20.2 2.64 3.3
80 30.6 21.0 2.75 3.3
60 30.1 19.2 2.47 3.6
68 30.6 20.6 2.64 3.4
80 31.1 21.4 2.75 3.3
60 32.6 21.4 2.49 3.8
68 33.2 22.9 2.67 3.6
80 33.7 23.8 2.78 3.6
60 34.1 23.0 2.51 4.0
68 34.7 24.6 2.68 3.8
80 35.3 25.6 2.79 3.7
60 34.7 23.4 2.51 4.1
68 35.3 25.0 2.69 3.9
80 35.9 26.1 2.80 3.8
60 37.3 25.5 2.53 4.3
68 38.0 27.3 2.71 4.1
80 38.5 28.4 2.82 4.0
60 39.3 27.3 2.55 4.5
68 40.0 29.2 2.73 4.3
80 40.6 30.4 2.84 4.2
60 39.9 27.8 2.56 4.6
68 40.6 29.8 2.74 4.3
80 41.3 31.0 2.85 4.2
60 42.3 30.3 2.58 4.8
68 43.0 32.4 2.77 4.6
80 43.7 33.7 2.88 4.4
60 44.7 32.1 2.61 5.0
68 45.5 34.4 2.79 4.8
80 46.2 35.8 2.90 4.7
60 45.5 32.8 2.61 5.1
68 46.3 35.1 2.80 4.9
80 47.0 36.6 2.91 4.7
60 47.5 34.6 2.63 5.3
68 48.3 37.0 2.81 5.0
80 49.1 38.5 2.92 4.9
60 50.5 37.3 2.64 5.6
68 51.4 40.0 2.83 5.3
80 52.2 41.6 2.95 5.2
60 51.5 38.2 2.65 5.7
68 52.4 40.9 2.84 5.4
80 53.2 42.6 2.95 5.3
60 53.0 39.5 2.66 5.8
68 53.9 42.3 2.84 5.5
80 54.7 44.0 2.96 5.4
60 56.5 42.8 2.68 6.2
68 57.5 45.8 2.87 5.9
80 58.4 47.7 2.98 5.7
60 57.7 43.8 2.69 6.3
68 58.7 46.9 2.87 6.0
80 59.6 48.8 2.99 5.8
60 58.6 44.6 2.69 6.4
68 59.6 47.7 2.88 6.1
80 60.5 49.7 3.00 5.9
60 62.7 48.4 2.71 6.8
68 63.8 51.8 2.90 6.4
80 64.8 53.9 3.02 6.3
60 64.0 49.6 2.72 6.9
68 65.1 53.1 2.91 6.6
80 66.2 55.2 3.03 6.4
Total
KBtu/hr.
Engineering Submittal Sheet
Heat of Absp
kBtu/hr
Power kW COP
90
100
110
DISCLAIMER: The performance reported herein is based on testing by FHP. Variations in the installation and operational environment may alter performance. Bosch disclaims all warranties,
express and implied, that the performance will be as reported, including the warranty of merchantability and fi tness for purpose. In addition, continuous research and development may result in a
change to an appliances design and specifi cations at the time of order, which Bosch may change without notice. Before purchase, confi rm the design specifi cations of the appliance.
30 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
15.0 13.7 5.8
18.0 19.1 8.1
9.0 5.4 2.3
15.0 13.4 5.7
18.0 18.6 7.9
9.0 5.2 2.2
15.0 13.2 5.6
18.0 18.4 7.8
BTC 760108306 H | 12.2018
Operation Not Recommended
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.
Page 31
SM Series -
Residential Geothermal Heat Pumps
Antifreeze Correction
Antifreeze Type Antifreeze %
Total Cap. Sens. Cap Power Htg. Cap Power
Water 0 1.000 1.000 1.000 1.000 1.000 1.000
5 0.997 0.997 1.004 0.989 0.997 1.060
Propylene Glycol
Methanol
Ethanol
Ethylene Glycol
10 0.994 0.994 1.006 0.986 0.995 1.125
15 0.990 0.990 1.009 0.978 0.988 1.190
25 0.983 0.983 1.016 0.960 0.979 1.300
5 0.997 0.997 1.003 0.990 0.997 1.060
10 0.996 0.996 1.005 0.979 0.993 1.100
15 0.994 0.994 1.008 0.970 0.990 1.140
5 0.998 0.998 1.002 0.981 0.994 1.160
10 0.996 0.996 1.004 0.960 0.988 1.230
15 0.992 0.992 1.006 0.944 0.983 1.280
25 0.986 0.986 1.009 0.917 0.974 1.400
5 0.997 0.997 1.003 0.993 0.998 1.060
10 0.995 0.995 1.004 0.986 0.996 1.120
15 0.992 0.992 1.005 0.980 0.993 1.190
25 0.988 0.988 1.009 0.970 0.990 1.330
30 0.985 0.985 1.012 0.965 0.987 1.400
Engineering Submittal Sheet
Cooling Heating
EWT 90 Deg.F EWT 30 Deg. F
WPD Correction
Factor EWT 30 °F
31 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
BTC 760108306 H | 12.2018
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 32
SM Series -
Residential Geothermal Heat Pumps
SM024-1VT Octave Band Sound Power Levels dB, re 10-12 Watts
Description Load
Cooling Part 85 58 56 53 50 40 40 32 60 55
Casing
Radiated
Ducted
Discharge
Cooling Full 85 60 57 53 51 44 44 39 60 56
Heating Part 84 62 56 54 49 41 41 33 60 55
Heating Full 84 64 59 55 51 45 46 40 60 57
F A N O n l y 6 75 55 04 83 83 43 62 6 4 8 4 8
Cooling Part 82 63 51 56 54 48 43 35 60 58
Cooling Full 83 64 53 58 56 51 47 38 62 60
Heating Part 85 66 52 57 55 49 45 36 62 59
Heating Full 84 67 55 60 57 53 49 40 63 62
F A N O n l y 7 66 25 26 15 44 94 53 7 6 0 6 0
63 125 250 500 1000 2000 4000 8000 "ARI-260:2011 (50Hz-10kHz)" "ARI-260:2001 (100hz-10kHz)"
SM024-1HZ Octave Band Sound Power Levels dB, re 10-12 Watts
Description Load
Cooling Part 79 66 60 54 53 44 38 31 59 58
Casing
Radiated
Ducted
Discharge
Cooling Full 80 63 60 54 54 47 40 37 59 58
Heating Part 74 66 59 54 52 43 38 31 58 57
Heating Full 74 65 61 53 54 45 39 34 58 58
F A N O n l y 7 36 15 65 14 84 33 83 0 5 4 5 3
Cooling Part 75 67 60 67 63 59 56 49 68 63
Cooling Full 76 68 62 68 65 61 58 52 70 67
Heating Part 77 67 60 65 63 58 56 49 67 63
Heating Full 77 70 62 68 65 61 59 53 70 67
F A N O n l y 7 56 76 06 66 35 95 64 9 6 7 6 3
63 125 250 500 1000 2000 4000 8000 "ARI-260:2011 (50Hz-10kHz)" "ARI-260:2001 (100hz-10kHz)"
Center Frequency - Hz A weighted overall (dBA) A weighted overall (dBA)
Center Frequency - Hz A weighted overall (dBA) A weighted overall (dBA)
Engineering Submittal Sheet
SM036-1VT Octave Band Sound Power Levels dB, re 10-12 Watts
Description Load
Cooling Part
Cooling Full
Casing
Radiated
Heating Part
Heating Full
FAN Only
Cooling Part
Cooling Full
Ducted
Discharge
Heating Part
Heating Full
FAN Only
63 125 250 500 1000 2000 4000 8000 "ARI-260:2011 (50Hz-10kHz)" "ARI-260:2001 (100hz-10kHz)"
75 57 53 49 44 35 31 31 52 50
72 60 54 49 46 38 42 42 53 53
78 61 51 48 44 36 33 31 54 50
80 63 55 49 47 39 40 39 56 53
66 54 45 41 38 31 24 23 45 44
80 64 52 56 55 49 43 35 60 59
81 65 65 58 58 53 47 40 62 62
82 66 53 57 57 50 44 35 61 60
81 67 56 59 60 54 49 39 64 63
76 65 52 57 55 50 45 36 60 59
Center Frequency - Hz A weighted overall (dBA) A weighted overall (dBA)
32 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
BTC 760108306 H | 12.2018
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 33
SM Series -
Residential Geothermal Heat Pumps
SM036-1HZ Octave Band Sound Power Levels dB, re 10-12 Watts
Description Load
Cooling Part 75 61 53 50 45 39 34 31 53 52
Casing
Radiated
Ducted
Discharge
Cooling Full 75 65 55 52 49 43 41 40 56 55
Heating Part 74 60 52 50 44 38 33 30 53 52
Heating Full 73 66 57 51 48 42 39 36 56 55
F A N O n l y 6 65 34 84 54 23 62 92 4 4 8 4 7
Cooling Part 78 65 56 61 59 55 53 46 64 63
Cooling Full 89 71 59 63 62 59 57 51 68 67
Heating Part 79 65 56 61 59 56 53 46 64 63
Heating Full 80 68 59 63 62 59 58 52 67 67
F A N O n l y 7 96 65 66 15 95 55 34 6 6 4 6 3
63 125 250 500 1000 2000 4000 8000 "ARI-260:2011 (50Hz-10kHz)" "ARI-260:2001 (100hz-10kHz)"
SM048-1VT Octave Band Sound Power Levels dB, re 10-12 Watts
Description Load
Cooling Part 71 59 55 53 46 41 35 33 54 53
Casing
Radiated
Ducted
Discharge
Cooling Full 75 63 58 55 49 44 40 38 57 56
Heating Part 77 62 56 53 46 40 35 32 55 54
Heating Full 78 64 58 54 48 42 38 35 57 56
F A N O n l y 6 85 44 64 44 03 52 72 3 4 7 4 6
Cooling Part 78 64 53 57 57 52 46 38 61 60
Cooling Full 80 67 58 60 62 57 52 46 65 65
Heating Part 79 68 56 59 59 53 47 39 62 62
Heating Full 81 72 60 62 63 59 54 48 67 67
F A N O n l y 7 76 55 45 95 95 45 04 1 6 3 6 3
63 125 250 500 1000 2000 4000 8000 "ARI-260:2011 (50Hz-10kHz)" "ARI-260:2001 (100hz-10kHz)"
Center Frequency - Hz A weighted overall (dBA) A weighted overall (dBA)
Center Frequency - Hz A weighted overall (dBA) A weighted overall (dBA)
Engineering Submittal Sheet
SM048-1HZ Octave Band Sound Power Levels dB, re 10-12 Watts
Description Load
Cooling Part 75 69 56 52 50 43 36 32 57 57
Casing
Radiated
Ducted
Discharge
33 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
Cooling Full 77 75 60 53 53 48 40 36 62 61
Heating Part 77 69 58 52 51 43 35 31 58 57
Heating Full 76 75 69 53 53 47 39 34 63 63
F A N O n l y 6 95 65 64 94 84 33 52 7 5 3 5 2
Cooling Part 82 70 59 63 63 59 58 52 67 67
Cooling Full 88 75 64 67 66 64 62 58 72 71
Heating Part 81 69 60 64 63 60 58 53 68 67
Heating Full 83 74 64 67 66 64 63 58 71 71
F A N O n l y 8 67 06 06 36 26 05 85 2 6 8 6 7
63 125 250 500 1000 2000 4000 8000 "ARI-260:2011 (50Hz-10kHz)" "ARI-260:2001 (100hz-10kHz)"
Center Frequency - Hz A weighted overall (dBA) A weighted overall (dBA)
BTC 760108306 H | 12.2018
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 34
SM Series -
Residential Geothermal Heat Pumps
SM060-1VT Octave Band Sound Power Levels dB, re 10-12 Watts
Description Load
Cooling Part 83 60 54 53 51 48 39 36 59 56
Casing
Radiated
Ducted
Discharge
Cooling Full 85 63 57 54 54 51 42 38 62 58
Heating Part 78 63 54 52 51 47 38 36 57 55
Heating Full 84 65 58 53 54 52 43 36 61 59
F A N O n l y 6 85 64 84 84 74 43 32 4 5 1 5 1
Cooling Part 77 65 57 60 61 57 52 45 64 64
Cooling Full 80 70 62 63 65 63 59 54 69 69
Heating Part 81 68 60 61 62 59 54 46 66 66
Heating Full 82 72 65 65 67 64 60 54 71 71
F A N O n l y 7 76 75 76 36 25 95 64 8 6 7 6 7
63 125 250 500 1000 2000 4000 8000 "ARI-260:2011 (50Hz-10kHz)" "ARI-260:2001 (100hz-10kHz)"
SM060-1HZ Octave Band Sound Power Levels dB, re 10-12 Watts
Description Load
Cooling Part 82 66 58 55 51 45 42 37 59 57
Casing
Radiated
Ducted
Discharge
Cooling Full 79 72 62 58 55 49 47 42 62 61
Heating Part 76 67 62 57 52 47 47 47 60 60
Heating Full 82 74 63 58 56 49 46 42 63 62
F A N O n l y 7 16 05 75 34 94 43 92 9 5 5 5 5
Cooling Part 89 73 63 67 63 61 60 54 70 69
Cooling Full 94 79 68 70 68 66 66 61 75 74
Heating Part 88 74 63 67 64 61 60 54 70 70
Heating Full 94 79 68 70 68 66 66 61 75 74
F A N O n l y 8 77 36 36 76 46 26 05 4 7 0 7 0
63 125 250 500 1000 2000 4000 8000 "ARI-260:2011 (50Hz-10kHz)" "ARI-260:2001 (100hz-10kHz)"
Center Frequency - Hz A weighted overall (dBA) A weighted overall (dBA)
Center Frequency - Hz A weighted overall (dBA) A weighted overall (dBA)
Engineering Submittal Sheet
SM070-1VT Octave Band Sound Power Levels dB, re 10-12 Watts
Description Load
Cooling Part 77 62 57 56 55 52 45 39 60 60
Casing
Radiated
Ducted
Discharge
34 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
Cooling Full 81 65 61 58 61 58 51 43 65 64
Heating Part 79 64 60 54 52 49 42 40 59 58
Heating Full 82 67 60 56 56 55 48 41 62 61
F A N O n l y 7 05 75 25 14 94 84 02 9 5 5 5 4
Cooling Part 80 71 63 68 67 64 62 56 72 72
Cooling Full 81 76 68 73 74 70 69 64 78 78
Heating Part 82 73 63 64 66 63 58 51 70 70
Heating Full 85 78 70 72 72 68 67 61 76 76
F A N O n l y 7 87 16 26 86 76 36 25 5 7 1 7 1
63 125 250 500 1000 2000 4000 8000 "ARI-260:2011 (50Hz-10kHz)" "ARI-260:2001 (100hz-10kHz)"
Center Frequency - Hz A weighted overall (dBA) A weighted overall (dBA)
BTC 760108306 H | 12.2018
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 35
SM Series -
Residential Geothermal Heat Pumps
SM070-1HZ Octave Band Sound Power Levels dB, re 10-12 Watts
Description Load
Cooling Part 82 68 61 57 52 49 44 36 61 59
Casing
Radiated
Ducted
Discharge
Cooling Full 80 72 63 59 54 51 46 39 62 61
Heating Part 75 71 63 59 52 48 44 40 61 61
Heating Full 77 74 64 60 55 50 45 37 63 63
F A N O n l y 7 36 36 15 55 14 94 44 2 5 8 5 8
Cooling Part 92 78 67 69 68 66 64 59 74 73
Cooling Full 97 83 72 72 73 70 69 64 78 77
Heating Part 92 79 68 70 69 66 64 59 74 74
Heating Full 96 82 73 73 74 70 69 64 79 78
F A N O n l y 9 37 96 87 06 96 66 45 9 7 4 7 4
63 125 250 500 1000 2000 4000 8000 "ARI-260:2011 (50Hz-10kHz)" "ARI-260:2001 (100hz-10kHz)"
Casing radiated sound power represents the sound
a person would hear if they were standing directly in
front of the unit. Ducted discharge sound power levels
represent the sound a person would hear through
air vents in a room when the heat pump is installed
elsewhere.
Center Frequency - Hz A weighted overall (dBA) A weighted overall (dBA)
Engineering Submittal Sheet
Blower Performance Data
Model
SM024 Full Load 800 400 15.00% 680 800 400 0-0.8
SM024 Part Load 704 352 15.00% 598 704 400 0-0.8
SM036 Full Load 1200 600 15.00% 1020 1350 400 0-1.2
SM036 Part Load 1056 528 15.00% 898 1188 400 0-1.2
SM048 Full Load 1600 800 15.00% 1360 1600 400 0-1.2
SM048 Part Load 1408 704 15.00% 1197 1408 400 0-1.2
SM060 Full Load 2000 1000 15.00% 1700 2050 400 0-1.2
SM060 Part Load 1760 880 15.00% 1496 1804 400 0-1.2
SM070 Full Load 2400 1200 15.00% 2040 2250 400 0-1.2
SM070 Part Load 2112 1056 15.00% 1795 1980 400 0-1.2
Rated Airfl ow
at default
400 CFM/Ton
Fan Only
Ventilation 50%
DeHum
Reduction
Percent
Effective
DeHum
Airfl ow
Most effi cient
effective Airfl ow
Confi g SCT
Min Airfl ow/ton
Heater
Static
in. WC
Min CFM/ton in cooling is 270 CFM/ton;
If calculated values fall below this limit, the control will
default to this minimum limit.
35 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
BTC 760108306 H | 12.2018
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 36
SM Series -
Residential Geothermal Heat Pumps
Field Install Accessory - Bosch Connected Control Wi-Fi Thermostat
Description Part Number Heat Cool Humidity
Bosch Connected Control (BCC100) 8-733-948-009
Specifi cations
Main Menu
Wi-Fi / Cloud Access
Indicator
Engineering Submittal Sheet
42 Y e s
System Mode /
Status
Fan Mode /
Status
Humidity
Setup
Current Space
Humidity
Set-Points
Current
Schedule
Adjust
Temperature
Set-Points
3.07"
(78 mm)
Current Room
Temperature
5.20" (132 mm)
Field Install Accessory - SmartStart Assist Kit
Part Number
8733920430
SM024 SM036 SM048 SM060 SM070
VT HZ VT HZ VT HZ VT HZ VT HZ
0.98" (25 mm)
0.67" (17 mm)
— 5 Inch Touch Screen 854 x 480 Pixels
— 7 Relay Outputs (Terminals) G, Y1, Y2, W1, W2, O/B, H/dH
— 1 Data Input (Pulse signals from Bosch WSHP)
— Displays Bosch Water Source Heat Pump Fault Messages
— Wi-Fi (802.11a/b/g/n) 2.4GHz (not compatible with 5GHz)
— FCC and IC Certification
— 5 Year Limited Warranty (see website for details)
Compatibility
— Conventional (Gas, Oil, Electric): Up to 2 Heat / 2 Cool
— Heat Pump (O/B to energize reversing valve in cool/heat): Up to 4 Heat / 2 Cool
— Supports up to 1 Accessory Unit: Humidifier or Dehumidifer (not provided by
Bosch)
— Unit Modes: Heat, Cool, Auto, Off, Emergency Heat
— Fan Modes: Auto, On, Circulate
— Supports 2 Transformer Systems (Rh and Rc)
— C-Wire Required for Installation
— Supports Active and Passive Dehumidifi cation without the need for external
relays, such as Bosch Water Source Heat Pump products equipped with a Hot
Gas Reheat Coil and/or ECM motor
Field Install Accessory - Internally Mounted Electric Heat Kits
Part Number Kilowatt Heater - 208/230V
7738003204 Electric Heat - 3.6/4.8 kW
7738003205 Electric Heat - 7.8/9.6 kW
7738003206 Electric Heat - 10.8/14.4 kW
7738003207 Electric Heat - 14.4/19.2 kW
SM024 SM036 SM048 SM060 SM070
Field Install Accessory - Pump/Valve Relay Kit
Part Number
8733951906
SM024 SM036 SM048 SM060 SM070
VT HZ VT HZ VT HZ VT HZ VT HZ
37 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
BTC 760108306 H | 12.2018
Availability per Unit
Bosch Thermotechnology Corp.
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 37
SM Series -
Engineering Submittal Sheet
Residential Geothermal Heat Pumps
Field Install Accessory - Duct Mounted Electric Heaters 208/230V
Nominal
BTUH
18000 7738002745
24000 7738002746 7738002747 N/A N/A 800 13.75 x 13.75 14 x 14
30000 7738002748 7738002749 N/A N/A 1000 15.75 x 15.75 16 x 16
36000 7738002748 7738002749 N/A N/A 1200 15.75 x 15.75 16 x 16
42000 7738002747 7738002751 7738002752 N/A 1400 17.75 x 17.75 18 x 18
48000 7738002747 7738002751 7738002752 N/A 1600 17.75 x 17.75 18 x 18
60000 7738002747 7738002751 7738002752 7738002753 2000 17.75 x 17.75 18 x 18
70000 7738002747
5 kW 10 kW 15 kW 20 kW
7738002751 7738002752 7738002753 2200 17.75 x 17.75 18 x 18
Duct mounted heaters are only available in
single phase 208/230 V. Please refer to Manufacturer’s
Installation and Operation Manual for proper installation
and guidelines. It is recommended to use a seven (7)
conductor cables for thermostat interface. It is required
for the duct mounted heater to have an independent
power supply. In fi berglass duct systems, a metal sleeve
MUST be used as an insert and support to the heater.
Order #
N/A N/A N/A 600 13.75 x 13.75 14 x 14
Nominal
CFM
Duct Flange Connection in
Inches
Nominal Dimension in
Inches
Field Install Accessory - Swivel Connector Kit (two connectors shipped loose with each unit)
Order Number Type and Size
8733927179 Male 3/4" NPT MPT to 1" swivel FPT
8733927180 Male 1" NPT MPT to 1" swivel FPT
SM024 SM036 SM048 SM060 SM070
VT HZ VT HZ VT HZ VT HZ VT HZ
Swivel fi ttings are used in typical residential
installations where water pressure ratings are below
125 psi. For higher pressure ratings which are typical
to commercial installations, swivel fi ttings MUST NOT
be used.
Replacement Air Filter Information
Nominal Filter Size
(MERV8 fi lters recommended
MERV13 fi lters used only with
horizontal units)
16 X 30 X 2 2 2
18 X 18 X 2 2
18 X 20 X 2 33
20 X 24 X 2 2 2
20 X 30 X 2 22
24 X 24 X 2
SM024 SM036 SM048 SM060 SM070
VT HZ VT HZ VT HZ VT HZ VT HZ
Quanity Need per Unit
1
38 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
BTC 760108306 H | 12.2018
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 38
SM Series -
Engineering Submittal Sheet
Residential Geothermal Heat Pumps
Field Install Accessory - Stainless Steel Hose Kits
Options Option 1 Option 2 Option 3** Option 4**,*** Option 5**, *** Option 6**, ***
Hose Size
(Length,
Diameter)
12 Inch
1/2" L T111H02121
24 Inch
3/4" S T111H03241 T111H03242 T111H03243 T111H03244 T111H03245 T111H03246
1" L T111H04241 T111H04242 T111H04243 T111H04244 T111H04245 T111H04246
1" S T111H04241 T111H04242 T111H04247 T111H04248 T111H04249 T111H04240
1 - 1/4" S T111H05241 T111H05242 T111H05243 T111H05244 T111H05245 T111H05246
1 - 1/2" L T111H06241 T111H06242 T111H06243 T111H06244 T111H06245 T111H06246
1 - 1/2" S T111H06241 T111H06242 T111H06247 T111H06248 T111H06249 T111H06240
2" S T111H08241
36 Inch
3/4" S T111H03361 T111H03362 T111H03363 T111H03364 T111H03365 T111H03366
1" L T111H04361 T111H04362 T111H04363 T111H04364 T111H04365 T111H04366
1" S T111H04361 T111H04362 T111H04367 T111H04368 T111H04369 T111H04360
1 - 1/4" S T111H05361 T111H05362 T111H05363 T111H05364 T111H05365 T111H05366
1 - 1/2" L T111H06361 T111H06362 T111H06363 T111H06364 T111H06365 T111H06366
1 - 1/2" S T111H06361 T111H06362 T111H06367 T111H06368 T111H06369 T111H06360
2" S T111H08361
* All Hose Kis include S/R ported ball valves with swivel and P/T port.
** 'L' and 'S' only apply to kit options 3 through 6
*** GMP's are required for hose kits in options 3-6
Hoses Only with
Swivel
Part # Part # Part # Part # Part # Part #
Hose Kit Hoses with
Ported Ball Valves,
Swivel and One P/T*
T111H02122 T111H02123 T111H02124 T111H02125 T111H02126
T111H08242 T111H08243 T111H08244 T111H08245 T111H08246
T111H08362 T111H08363 T111H08364 T111H08365 T111H08366
Hose Kit with
Automatic Flow Valve
(AFV)*
Hose kit with AFV,
Y-Strainer & Blow
Down Valve*
Hose Kit with AFV
and Electric Valve*
Hose Kit with AFV,
Y-Strainer, BDV and
Electric Valve*
Hose Kit Flow Rates by Size
Please see Technical Service Bulletin: Heat Pump Hose Kits – Water Flow Rates.
This document is located at www.bosch-climate.us under Support Center > Downloads > Downloads for Bosch Products > Service Bulletins.
39 of 38
Bosch Thermotechnology Corp. reserves the right to make changes without notice due
to continuing engineering and technological advances |
BTC 760108306 H | 12.2018
Londonderry, NH • Watertown, MA • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Bosch Thermotechnology Corp.