The induction hob with integrated ventilation module: combines induction with ventilation technology for perfect results.
DirectSelect: Direct, simple selection of the desired cooking zone, power and additional functions.
PowerBoost: Up to 50% more power for faster heating.
Technical Data
Product name/family : Cooking zone ceramic Construction type : Built-in Energy input : Electric Required niche size for installation (HxWxD) :
223 x 560-560 x 490-490 Width of the appliance : 710 Dimensions : 223 x 710 x 522 Dimensions of the packed product (HxWxD) (mm) :
430 x 940 x 660 Net weight (kg) : 24.405 Gross weight (kg) : 29.3 Residual heat indicator : without Location of control panel : Hob front Basic surface material : Ceramic Color of surface : Black Approval certificates : CE, VDE Length of electrical supply cord (cm) : 110 Sealed Burners : No heating with booster : All Power of 2nd heating element (kW) : 3.6 Maximum output air extraction (m3/h) : 500 Boost position output recirculating (m3/h) : 615.0 Maximum output recirculating air (m3/h) : 500 Boost position air extraction (m³/h) : 622 Noise level (dB(A) re 1 pW) : 69 Odour filter : No Operating Mode : Convertible Delay Shut off modes : 30 Electrical connection rating (W) : 7400 Voltage (V) : 220-240/380-415 Frequency (Hz) : 50-60 Main colour of product : Black Approval certificates : CE, VDE Length of electrical supply cord (cm) : 110 Required niche size for installation (HxWxD) :
223 x 560-560 x 490-490 Dimensions : 223 x 710 x 522 Dimensions of the packed product (HxWxD) (mm) :
430 x 940 x 660 Net weight (kg) : 24.405 Gross weight (kg) : 29.3
'!2E20AF-bjeeah!
Serie | 6, Induction hob with integrated ventilation system, 70 cm PVQ731F15E
Optional accessories
HEZ9CF260 Pan Ø 22 / 26 cm, HEZ9LP160 Pot Ø 14 (bottom) / 16 cm (top), HEZ9LP200 Pot Ø 18 (bottom) / 20 cm (top), HEZ9SE030 Set of 2 pots and 1 pan, HEZ9VDSB1 90° flat duct bend horizontal, HEZ9VDSB2 90° flat duct L vertical, HEZ9VDSB3 90° flat duct M vertical, HEZ9VDSI0 Adapter round­flat, HEZ9VDSI1 90° Adapter round-flat, HEZ9VDSM1 Straight tube 500mm, HEZ9VDSM2 Straight tube 1000mm, HEZ9VDSS1 Connector sleeve (female), HEZ9VEDU0 Acoustics Filter, HEZ9VRCR0 cleanAir recirculation replenishment fil, HEZ9VRPD0 Basic kit (partly-)ducted recirculation, HEZ9VRUD0 Kit Unducted Recirculation
1/7
Serie | 6, Induction hob with integrated ventilation system, 70 cm PVQ731F15E
The induction hob with integrated ventilation module: combines induction with ventilation technology for perfect results.
Design
Front facette design
-
Quickness
PowerBoost function for all zones
-
Special features
4 induction cooking zones
-
2 Combi zones
-
DirectSelect
-
MoveMode: MoveMode (2 levels)
-
Digital display, red
-
Timer for all zones
-
Timer - shows how long the cooktop is in use ReStart function
-
QuickStart function
-
Power and size
Cooking zones:
-
1 x 380 mm x 210 mm, 3.6 KW Induction or 2 x 190 mm, 210 mm, 2.2 KW (max. power 3.7 KW) Induction; 1 x 380 mm x 210 mm, 3.6 KW Induction or 2 x 190 mm, 210 mm , 2.2 KW (max power 3.7 KW) Induction
Variable 17-stage power settings for each zone
-
Safety Features
2 stage residual heat indicator for each zone
-
Main on/off switch
-
Automatic pan recognition sensor
-
Automatic safety shut off Control panel lock Control panel lock function
Energy consumption display
-
Technical information
Measurement: (H/B/T) 223 x 710 x 522 mm
-
Installation dimensions: (ID/W/D) 223 mm x 560 mm x 490
-
mm
Suitable for installation into a 60 cm base cabinet
-
Min. worktop thickness: 16 mm (Installation in thinner
-
worktops is also possible with the spare part: 626792)
Length wire connection: 110 cm
-
Connected load: 7.4 KW
-
Cable included
-
Integrated ventilation downdraft system
Induction cooktop with fully integrated high-performance
-
downdraft extractor.
Suitable for ducted or recirculated extraction configuration
-
(incl. differentiated software modes). Respective mandatory installation acessories required:
- HEZ9VEDU0 for ducted extraction
- Starter kit HEZ9VRUD0 for unducted recirculation with cleanAir odour filters.
- HEZ9VRPD0 for fully ducted and partly-ducted recirculation with cleanAir odour filters.
- HEZ9VEDU0 for ducted extraction
-
- HEZ9VRPD0 for fully ducted and partly-ducted recirculation
-
with cleanAir odour filters. Starter kit HEZ9VRUD0 for unducted recirculation with cleanAir odour filters.
Aesthetically integrated fully flush air intake design with
-
floating, heat resistant glass ceramics element for free movement and placement of cookware.
Ventilation system with 9 electronically controlled fan power
-
levels and 2 Boost-/Intensive fan power levels (with automatic revert) via DirectSelect user interface:
- Automatic switch-on of ventilation system when a cooking zone is used.
- Automatic delayed shut-off after cooking to erase residual odors after cooking (in specific ultra low-noise fan level, 12min in ducted extraction, 30min in recirculated extraction, can be shut-off manually).
- Fully manual control possible via DirectSelect.
- Automatic switch-on of ventilation system when a cooking
-
zone is used.
- Automatic delayed shut-off after cooking to erase residual
-
odors after cooking (in specific ultra low-noise fan level, 12min in ducted extraction, 30min in recirculated extraction, can be shut-off manually).
- Fully manual control possible via DirectSelect.
-
High-performance, low-noise motor with energy-efficient
-
BLDC-technology. High extraction rates at very low noises with pleasant noise frequencies through psycho-acoustically and aerodynamically optimised interior with enclosed, hidden motor. Highly pressure-drop resistant even with longer and more complex ducting systems.
Easy-to-detach and easy-to-clean grease filter and liquid
-
collector unit:
- Convenient one-hand removal of unit via floating glass ceramics handle.
- Integrated, large-scale, high performance stainless-steel grease filters with 12 filtration layers and one black top
2/7
layer for enhanced aesthetical integration. Grease filtration efficiency of 94 %.
- All parts of the unit are easy-to-clean, fully dishwasher safe and heat resistant.
- (Upper) Liquid collector unit with 200ml of capacity for standard accidental spillages or cooking condensate.
- Powerful drainage system for spillages that exceed 200ml of liquids.
- Liquid safety collector with additional capacity of 700ml for more severe accidental situations. Dishwasher safe. Easily accessible and detachable from below.
- Overall capturing capacity of 900ml (200ml + 700ml).
- Watertight motor system.
- Convenient one-hand removal of unit via floating glass
-
ceramics handle.
- Integrated, large-scale, high performance stainless-steel
-
grease filters with 12 filtration layers and one black top layer for enhanced aesthetical integration. Grease filtration efficiency of 94 %.
- All parts of the unit are easy-to-clean, fully dishwasher safe
-
and heat resistant.
- (Upper) Liquid collector unit with 200ml of capacity for
-
standard accidental spillages or cooking condensate.
- Powerful drainage system for spillages that exceed 200ml of
-
liquids.
- Liquid safety collector with additional capacity of 700ml for
-
more severe accidental situations. Dishwasher safe. Easily accessible and detachable from below.
- Overall capturing capacity of 900ml (200ml + 700ml).
-
- Watertight motor system.
-
Ventilation system performance:
-
- Extraction performance in ducted extraction (according to EN 61591): min. normal setting 154 MQH , max. normal setting 500 MQH, max. Boost-/Intensive setting 622 MQH.
- Extraction performance in recirculated extraction (according to EN 61591): min. normal setting 150 m3/h , max. normal setting 500 m3/h , max. Boost-/Intensive setting 615 m3/h.
- Noise level in ducted extraction (Sound power level according to EN 60704-3): min. normal setting 42 dB re 1 pW, max. normal setting 69 dB re 1 pW, max. Boost-/Intensive setting 74 dB re 1 pW.
- Noise level in recirculated extraction (Sound power level according to EN 60704-3. ): min. normal setting 41 dB re 1 pW, max. normal setting 68 dB re 1 pW, max. Boost-/Intensive setting 72 dB re 1 pW.
- Grease filter efficiency (according to EN 61591) 94 %. All performance data is preliminary and based on latest test results with advanced prototypes and will be updated with tests from final products.
- Extraction performance in ducted extraction (according
-
to EN 61591): min. normal setting 154 m3/h , max. normal setting 500 m3/h , max. Boost-/Intensive setting 622 m3/h .
- Extraction performance in recirculated extraction (according
-
to EN 61591): min. normal setting 150 m3/h , max. normal setting 500 m3/h , max. Boost-/Intensive setting 615 m3/h.
- Noise level in ducted extraction (Sound power level
-
according to EN 60704-3): min. normal setting 42 dB re 1 pW, max. normal setting 69 dB re 1 pW, max. Boost-/Intensive setting 74 dB re 1 pW.
- Noise level in recirculated extraction (Sound power level
-
according to EN 60704-3. ): min. normal setting 41 dB re
1 pW, max. normal setting 68 dB re 1 pW, max. Boost-/ Intensive setting 72 dB re 1 pW.
- Grease filter efficiency (according to EN 61591) 94 %.
-
All performance data is preliminary and based on latest test
-
results with advanced prototypes and will be updated with tests from final products.
Consumption data and energy efficiency (according to
-
Regulation (EU) No 65/2014):
- Energy Efficiency Class: B (at a range of energy efficiency classes from A+++ to D).
- Fluid Dynamic Efficiency: A .
- Average energy consumption: 57 .
- Grease filtration effciency class: B .
- Noise min. normal setting & max. normal setting: 42 dB & 69 dB .
- Energy Efficiency Class: B (at a range of energy efficiency
-
classes from A+++ to D).
- Fluid Dynamic Efficiency: A .
-
- Average energy consumption: 57 .
-
- Grease filtration effciency class: B .
-
- Noise min. normal setting & max. normal setting: 42 dB & 69
-
dB .
2 x 2 sets of directly integrated, high-performance cleanAir
-
odour filters (in recirculation configuration).
- Optimised odour reduction performance for cooking applications with complex odour molecules (e.g. fish).
- Large scale filter surface with high odour reduction capabilities.
- Lifetime of 360 hours of cooking (non-regenerative). 
- Low-noise filters with optimised psycho-acoustics.
- Easy-to-access and easy-to-remove from above.
- Replenishment cleanAir filter set HEZ9VRCR0. For ducted extraction configuration: 2 x 2 sets of directly integrated, high-performance low-noise acoustic filters for significantly lower noise and improved psycho-acoustics.
- Optimised odour reduction performance for cooking
-
applications with complex odour molecules (e.g. fish).
- Large scale filter surface with high odour reduction
-
capabilities.
- Lifetime of 360 hours of cooking (non-regenerative).
-
- Low-noise filters with optimised psycho-acoustics.
-
- Easy-to-access and easy-to-remove from above.
-
- Replenishment cleanAir filter set HEZ9VRCR0.
-
For ducted extraction configuration: 2 x 2 sets of directly
-
integrated, high-performance low-noise acoustic filters for significantly lower noise and improved psycho-acoustics.
3/7
Planning & installation notes
Suitable for ducted or recirculated extraction installations.
-
Respective mandatory installation acessories required:
- HEZ9VEDU0 for ducted extraction.
- Starter kit HEZ9VRUD0 for unducted recirculation with cleanAir odour filters.
- HEZ9VRPD0 for fully ducted and partly-ducted recirculation with cleanAir odour filters.
- HEZ9VEDU0 for ducted extraction.
-
- HEZ9VRPD0 for fully ducted and partly-ducted recirculation
-
with cleanAir odour filters. Starter kit HEZ9VRUD0 for unducted recirculation with cleanAir odour filters.
Planning suggestions:
-
- Installation is possible in island as well as wall oriented configurations.
- The product complies with the Needle Flame Test (according to IEC 60695-5-11), the V2 flammability class (according to UL94) and the B1 building material class (DIN 4102-1). The starter kit HEZ9VRUD0 for unducted recirculation complies with these standards as well.
- The max. immersion depth is 223mm below glass for top mounted appliances and 227mm for flush installed appliances.
- The appliance must be freely accessible from below (i.e. for accessing the lower liquid safety collector). - No false floor is necessary below the cooktop with integrated downdraft ventilation system. The drawers and/or shelves in the floor unit must be removable. The backpanel of the floor unit can be kept - only a cut-out for the air outlet is needed (position and size can be taken from the installation instructions).
- The "Plug 'n Play" starter kit HEZ9VRUD0 for unducted recirculation requires a vertical aperture of min. 25mm behind the backpanel of the furniture. Suggested for ideal performance are 50mm.
- The minimum worktop thickness is 16mm for top mounted and flush installed appliances with the standard installation system. Installation in even thinner worktops is also possible with the spare part: content 626792.
- The overall appliance weight is 26kg - the bearing capacity and stability, in the case of very thin worktops in particular, must be supported using suitable substructures. The overall appliance weight and the worktop manufacturer's structural integrity specifications are to be taken into account.
- The "Plug 'n Play" starter kit HEZ9VRUD0 for unducted recirculation enables easy and quick installations and can be planned in all worktop depths ≥60cm. For ducted installations
- in ducted extraction (HEZ9VEDU0) as well as fully or partly ducted recirculation (HEZ9VRPD0) - a worktop depth of ≥70cm is required.
- For partly ducted and unducted recirculation extraction installations, a return-flow aperture of ≥400cm² is to be respected in the plinth area. The aperture can be realized via outlet grids, lamella grids or subtly shortened plinths depending on the assortment of the kitchen furniture manufacturer.
- The air outlet on the backside of the appliance can directly be accessed with a male flat duct element (DN 150).
- The pressuredrop resistant blower allows longer and more complex ductings up to 8m with three 90° bows while keeping sufficient performance.
- When installing a ventilation hood with ducted extraction and a chimney-vented fireplace, the power supply line of the
appliance needs a suitable safety switch. This is not required for configurations in recirculated extraction.
- In ducted extraction configuration a one-way flap (or backflow trap) with a maximum opening pressure of 65Pa should be installed.
- Installation is possible in island as well as wall oriented
-
configurations.
- The product complies with the Needle Flame Test (according
-
to IEC 60695-5-11), the V2 flammability class (according to UL94) and the B1 building material class (DIN 4102-1). The starter kit HEZ9VRUD0 for unducted recirculation complies with these standards as well.
- The max. immersion depth is 223mm below glass for
-
top mounted appliances and 227mm for flush installed appliances.
- The appliance must be freely accessible from below (i.e. for
-
accessing the lower liquid safety collector).
- No false floor is necessary below the cooktop with
-
integrated downdraft ventilation system. The drawers and/or shelves in the floor unit must be removable. The backpanel of the floor unit can be kept - only a cut-out for the air outlet is needed (position and size can be taken from the installation instructions).
- The "Plug 'n Play" starter kit HEZ9VRUD0 for unducted
-
recirculation requires a vertical aperture of min. 25mm behind the backpanel of the furniture. Suggested for ideal performance are 50mm.
- The minimum worktop thickness is 16mm for top mounted
-
and flush installed appliances with the standard installation system. Installation in even thinner worktops is also possible with the spare part: content 626792.
- The overall appliance weight is 26kg - the bearing capacity
-
and stability, in the case of very thin worktops in particular, must be supported using suitable substructures. The overall appliance weight and the worktop manufacturer's structural integrity specifications are to be taken into account.
- The "Plug 'n Play" starter kit HEZ9VRUD0 for unducted
-
recirculation enables easy and quick installations and can be planned in all worktop depths ≥60cm. For ducted installations
- in ducted extraction (HEZ9VEDU0) as well as fully or partly ducted recirculation (HEZ9VRPD0) - a worktop depth of ≥70cm is required.
- For partly ducted and unducted recirculation extraction
-
installations, a return-flow aperture of ≥400cm² is to be respected in the plinth area. The aperture can be realized via outlet grids, lamella grids or subtly shortened plinths depending on the assortment of the kitchen furniture manufacturer.
- The air outlet on the backside of the appliance can directly
-
be accessed with a male flat duct element (DN 150).
- The pressuredrop resistant blower allows longer and more
-
complex ductings up to 8m with three 90° bows while keeping sufficient performance.
- When installing a ventilation hood with ducted extraction
-
and a chimney-vented fireplace, the power supply line of the
4/7
appliance needs a suitable safety switch. This is not required for configurations in recirculated extraction.
- In ducted extraction configuration a one-way flap (or
-
backflow trap) with a maximum opening pressure of 65Pa should be installed.
5/7
Serie | 6, Induction hob with integrated ventilation system, 70 cm PVQ731F15E
6/7
Serie | 6, Induction hob with integrated ventilation system, 70 cm PVQ731F15E
7/7