Bosch PVA-1KS Specsheet

Communications Systems | PVA-1KS PAVIRO Key Switch
PVA-1KS PAVIRO Key Switch
www.boschsecurity.com
u EN 54-16
u Locks unauthorized Call Station use
u Supervised
Certifications and approvals
EN 54-16: 2008
Installation/configuration notes
Assembly in call station
1. Disconnect the call station from all connectors
2. Unscrew the call station baseplate
3. Unplug the connection cable from the CN1 plug connector
4. Prepare the installation location. Use a sharp object (knife, scriber, or similar) to carefully punch through and cut out the pre-cut circle on the back housing. Perform any follow-up work that may be required to the installation location (e.g. filing, trimming)
5. Bore through the pre-cut side opening for the holding pin of the key switch cover
6. Align the switch and screw tightly in place with the supplied knurled screw
7. The supplied 4-pin cable and the resistors must be connected as shown in figure 2.1 or 2.2, depending on the intended purpose of the key switch.
Notice
Connect the key switch as shown in figure 2.1 (normally closed contact, NCC) to lock the call station via the key switch!
8. Note the connection sequence of the ribbon cable. The two external cables 1 (red) and 4 (green) must be cut as close to the cut-off point as possible and isolated. The two internal cables 2 (green) and 3 (green) must be soldered to switch connections 3 and 4. The polarity is not important.
9. Depending on whether the right/middle/left installation location will be used, plug the ribbon cable into plug connector CN201/CN202/CN203 on the circuit board
10. Plug the connecting cable into CN1 again
11. Re-attach the call station baseplate
12. Attach the connections
13. Configure the key switch in IRIS-Net
R2
10k
1 rt
2 gr
3 gr
4 gr
CN1-4
CN1-3
CN1-2
CN1-1
1
2
R1
10k
3
4
R2
10k
1 rt
2 gr
3 gr
4 gr
CN1-4
CN1-3
CN1-2
CN1-1
1
2
R1
10k
3
4
2 | PVA-1KS PAVIRO Key Switch
Represented by:
Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina:
Bosch Security Systems, Inc. 12000 Portland Avenue South Burnsville MN 55337, USA Phone: +1-800-392-3497 Fax: +1-800-955-6831 audiosupport@us.bosch.com www.boschsecurity.com
Bosch Security Systems B.V. P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com
Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia
Bosch (Shanghai) Security Systems Ltd. 201 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 200335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn
Robert Bosch Ltda Security Systems Division Via Anhanguera, Km 98 CEP 13065-900 Campinas, Sao Paulo, Brazil Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 latam.boschsecurity@bosch.com www.boschsecurity.com
© Bosch Security Systems 2015 | Data subject to change without notice 18889691403 | en, V2, 27. Jul 2015
Connecting the key switch as normally closed contact (NCC) for key lock function
Connecting the key switch as normally open contact (NOC) for special purposes
Parts included
Quantity Component
1 Key switch
1 Preconfigured 4-pin connecting cable
2 Resistor 10 kΩ
1 Installation note
Ordering information
PVA-1KS PAVIRO Key Switch
Order number PVA-1KS
Loading...