Bosch NEM936UC/01, NEM935UC/01, NEM932UC/01, NEM736UC/01, NEM735UC/01 Installation Guide

...
BOSCH
Installation Instructions
sosc_
NEM73
8oscH
NEM93
,O
,O
Bosch Glass Ceramic Cooktops
Models: NEM73, NEM93
Table of Contents
NOTE: The blocked letters, such as A, shown below, refer to illustrations on
Pages 2 & 4. Match these to the related text pages.
Overall Dimensions A ............................................................................................... 2
Power Supply B .......................................................................................................... 2
Cabinet Preparation and Clearances C ............................................................. 2, 3
Junction Box Location O ........................................................................................... 2
Countertop Cutout Dimensions IE ........................................................................ 2
Installing the Cool<top F ........................................................................................ 3-4
Secure Cool<top to Countertop G ..................................................................... 3-4
Solid Surface Countertop Installations 14 and I .................................................. 5
Electrical Connection ................................................................................................ 5
IMPORTANT: Save these instructions for Local Electrical Inspector's use.
INSTALLER: Please leave these Installation Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
READ AND SAVE THESE INSTRUCTIONS
OVERALL DIMENSIONS A
See Illustration A, Page2. These dimensions are overall.
POWER SUPPLY B
ELECTRICAL POWER CONNECTION FOR COOKTOP
Power Supply is dual rated: 240 Volts or 208 Volts, 3 wire, 60 Hz, with the following circuit breaker requirements: Model NEM73 at 30 Amps; Model NEM93 at 40Amps
JUNCTION BOX LOCATION D
Planthe installation of the unit so that the location of
the junction box is within 3 feet of the left rear of the
cooktop bosom. It must be accessible from the front of the cabinet.
Connect only to a 3-wire 120/240 or 120/208 volt ac system.The neutral is not required for the operation of this appliance but an independent ground is required.
Install ajunction box (not supplied), below the counter top within 3 feet of flexible conduit (supplied) located
at the left rear corner of the cooktop rough-in box.
PAGEI
Overall Dimensions
Model NEM73:Width 30"
Model NEM93:Width 36"
All Models: Depth 21 - I/8"
Height above countertop: I/4"
Cabinet Bottom
Building Back
Wall
Wall
r_ Required supply
Power
Model NEM73:30 Amp circuit breaker
Model NEM93:40 Amp circuit breaker
All 240Volt, 3 Wire, 60 Hz
208Volt, 3Wire, 60 Hz
r_ junction Box LocationMinimum Cabinet Clearances
MODEL NO.
NEM73
NEM93
DIM.
B C B C
Cooldng Surface
CounterTop Cutout Dimensions
/"_ / _ I" Flat Area
=' ,3,4F,atA,ea
r I" Flat Area
CUTOUT
DIMENSIONS*
Minimum
Inches / (mm)
19-7/8"/(505mm)
28-3/4'' / (731 mm)
19-7/8'' / (505 mm)
34a/4'' / (883 mm)
Maximum
Inches / (mm)
20" / (508 mm) 28-7/8'' / (734 mm) 20" / (508 mm) 34-7/8'' / (886 mm)
*For solid surface countertop installations, use maximum cutout dimensions and
consult manufacture surface for specific cutting instructions.
PAGE 2