Installation Instructions Models: NEM73, NEM93
Table of Contents
NOTE: The blocked letters, such as A, shown below, refer to illustrations on
Pages 2 & 4. Match these to the related text pages.
Overall Dimensions A ............................................................................................... 2
Power Supply B .......................................................................................................... 2
Cabinet Preparation and Clearances C ............................................................. 2, 3
Junction Box Location O ........................................................................................... 2
Countertop Cutout Dimensions IE ........................................................................ 2
Installing the Cool<top F ........................................................................................ 3-4
Secure Cool<top to Countertop G ..................................................................... 3-4
Solid Surface Countertop Installations 14 and I .................................................. 5
Electrical Connection ................................................................................................ 5
IMPORTANT: Save these instructions for Local Electrical Inspector's use.
INSTALLER: Please leave these Installation Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
READ AND SAVE THESE INSTRUCTIONS
OVERALL DIMENSIONS A
See Illustration A, Page2. These dimensions are overall.
POWER SUPPLY B
ELECTRICAL POWER CONNECTION
FOR COOKTOP
Power Supply is dual rated: 240 Volts or 208 Volts, 3
wire, 60 Hz, with the following circuit breaker
requirements: Model NEM73 at 30 Amps; Model
NEM93 at 40Amps
Connect only to a 3-wire 120/240 or 120/208 volt ac
system.The neutral is not required for the operation
of this appliance but an independent ground is required.
Install ajunction box (not supplied), below the counter
top within 3 feet of flexible conduit (supplied) located
at the left rear corner of the cooktop rough-in box.
JUNCTION BOX LOCATION D
Planthe installation of the unit so that the location of
the junction box is within 3 feet of the left rear of the
cooktop bosom. It must be accessible from the
front of the cabinet.
PAGEI