Bosch NEM73, NEM93 Installation Instructions Manual

Installation Instructions
NEM73
Bosch Glass Ceramic Cooktops
NEM93
Models: NEM73, NEM93
Installation Instructions Models: NEM73, NEM93
Table of Contents
NOTE: The blocked letters, such as A, shown below, refer to illustrations on
Overall Dimensions A ............................................................................................... 2
Power Supply B .......................................................................................................... 2
Cabinet Preparation and Clearances C ............................................................. 2, 3
Junction Box Location D........................................................................................... 2
Countertop Cutout Dimensions E ........................................................................ 2
Installing the Cooktop F ........................................................................................ 3-4
Secure Cooktop to Countertop G ..................................................................... 3-4
Solid Surface Countertop Installations H and I .................................................. 5
Electrical Connection ................................................................................................ 5
IMPORTANT: Save these instructions for Local Electrical Inspector’s use.
INSTALLER: Please leave these Installation Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
READ AND SAVE THESE INSTRUCTIONS
OVERALL DIMENSIONS
See Illustration A, Page 2. These dimensions are overall.
POWER SUPPLY B
ELECTRICAL POWER CONNECTION FOR COOKTOP
Power Supply is dual rated: 240 Volts or 208 Volts, 3 wire, 60 Hz, with the following circuit breaker requirements: NEM93 at 40 Amps
Model NEM73 at 30 Amps; Model
A
JUNCTION BOX LOCATION D
Plan the installation of the unit so that the location of the junction box is within 3 feet of the left rear of the cooktop bottom. It must be accessible from the
front of the cabinet.
Connect only to a 3-wire 120/240 or 120/208 volt ac system. The neutral is not required for the operation of this appliance but an independent ground is required.
Install a junction box (not supplied), below the counter top within 3 feet of flexible conduit (supplied) located at the left rear corner of the cooktop rough-in box.
PAGE 1
Installation Instructions
Models: NEM73, NEM93
A B
Overall Dimensions
Model NEM73: Width 30"
Model NEM93: Width 36"
All Models: Depth 21-1/8"
Height above countertop: 1/4"
C
Cabinet Bottom
(Unprotected)
Building Back
Minimum Cabinet Clearances
Wall
30" Min. (762 mm)
Building Side Wall
Model NEM73: 30 Amp circuit breaker
Model NEM93: 40 Amp circuit breaker
All Models
D
Required Power Supply
240 Volt, 3 Wire, 60 Hz
}
208 Volt, 3 Wire, 60 Hz
Junction Box Location
Conduit (Approx. 3 feet)
12" APPROXIMATE
"J" Box
Cooking Surface
E
30" Minumum
Counter Top Cutout Dimensions
1" Flat Area
B
1-3/4" Flat Area
1" Flat Area
C
2-1/2"
1" Flat Area
CUTOUT
MODEL NO. DIM. DIMENSIONS*
Minimum Maximum
Inches / (mm) Inches / (mm)
NEM73
NEM93 B 19
B19 C28
C34
-7
/8" / (505 mm) 20" / (508 mm)
-3
/4" / (731 mm) 28-7/8" / (734 mm)
-7
/8" / (505 mm) 20" / (508 mm)
-3
/4" / (883 mm) 34-7/8" / (886 mm)
*For solid surface countertop installations, use maximum cutout dimensions and
consult manufacture surface for specific cutting instructions.