Bosch NBN-80122-F6A, NBN-80122-F2A Installation Manual

DINION IP ultra 8000 MP
NBN-80122
en Installation Manual
DINION IP ultra 8000 MP Table of Contents | en 3

Table of contents

1
1.3 Important safety instructions 6
1.4 FCC and ICES compliance 7
1.5 Notices 8
2
3
3.5 Operation with external systems 11
4
4.2 Contents 13
4.3 System requirements 14
5
5.1 Lens mounting 15
5.2 Mounting the camera 16
5.3 Local storage 17
6
6.1 Network (and PoE power) 18
6.2 Auxiliary power 19
6.3 Alarm 20
6.4 Audio 22
6.5 Video monitor 23
6.6 Data 24
7
7.1 Setting up the camera 25
7.2 Local set-up 25
7.2.1 Field of view 26
7.2.2 Iris value 26
Bosch Security Systems 2015.04 | v2.0 | AM18-Q0688
Safety 5
Short information 9
System overview 10
Planning 13
Installation 15
Connection 18
Configuration 25
4 en | Table of Contents DINION IP ultra 8000 MP
7.3.1 Set-up via web browser 28
7.4 True Day/Night switching 29
8
Troubleshooting 30
9
Maintenance 37
9.2 Repair 37
9.3 Reset 38
10
Decommissioning 39
10.1 Transfer 39
10.2 Disposal 39
11
Technical data 40
2015.04 | v2.0 | AM18-Q0688 Bosch Security Systems
!
!
!
!
DINION IP ultra 8000 MP Safety | en 5
1
1.1
1.2

Safety

Safety message explanation

Caution!
Indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
Notice!
Indicates a situation which, if not avoided, could result in
damage to the equipment or environment, or data loss.

Safety precautions

Caution!
The Low Voltage power supply unit must comply with EN/UL
60950. The power supply must be a SELV-LPS unit or a SELV -
Class 2 unit (Safety Extra Low Voltage - Limited Power Source).
Caution!
Installation should only be performed by qualified service
personnel in accordance with the National Electrical Code
(NEC 800 CEC Section 60) or applicable local codes.
Caution!
Use only a +12 VDC power supply as an auxiliary power source.
The auxiliary power supply unit must be isolated from earth.
Bosch Security Systems 2015.04 | v2.0 | AM18-Q0688
6 en | Safety DINION IP ultra 8000 MP
1.3

Important safety instructions

Read, follow, and retain for future reference all of the following safety instructions. Follow all warnings before operating the unit.
1. Clean only with a dry cloth. Do not use liquid cleaners or aerosol cleaners.
2. Do not install unit near any heat sources such as radiators, heaters, stoves, or other equipment (including amplifiers) that produce heat.
3. Never spill liquid of any kind on the unit.
4. Take precautions to protect the unit from power and lightning surges.
5. Adjust only those controls specified in the operating instructions.
6. Operate the unit only from the type of power source indicated on the label.
7. Unless qualified, do not attempt to service a damaged unit yourself. Refer all servicing to qualified service personnel.
8. Install in accordance with the manufacturer's instructions in accordance with applicable local codes.
9. Use only attachments/accessories specified by the manufacturer.
2015.04 | v2.0 | AM18-Q0688 Bosch Security Systems
DINION IP ultra 8000 MP Safety | en 7
1.4

FCC and ICES compliance

FCC & ICES Information
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – reorient or relocate the receiving antenna; – increase the separation between the equipment and
receiver;
connect the equipment into an outlet on a circuit different
from that to which the receiver is connected;
consult the dealer or an experienced radio/TV technician
for help. Intentional or unintentional modifications, not expressly approved by the party responsible for compliance, shall not be made. Any such modifications could void the user's authority to operate the equipment. If necessary, the user should consult the dealer or an experienced radio/television technician for corrective action. The user may find the following booklet, prepared by the Federal Communications Commission, helpful: How to Identify and Resolve Radio-TV Interference Problems. This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.
Bosch Security Systems 2015.04 | v2.0 | AM18-Q0688
8 en | Safety DINION IP ultra 8000 MP
1.5

Notices

Notice!
Optical elements are sensitive and should be protected at all
times. Do not allow objects to come into contact with glass
surfaces and do not touch optical elements with your fingers.
Notice!
Video loss is inherent to digital video recording; therefore,
Bosch Security Systems cannot be held liable for any damage
that results from missing video information.
To minimize the risk of losing information, we recommend
multiple, redundant recording systems, and a procedure to
back up all analog and digital information.
Notice!
We recommend that memory cards only be used for local
storage of alarm recordings.
2015.04 | v2.0 | AM18-Q0688 Bosch Security Systems
DINION IP ultra 8000 MP Short information | en 9
2

Short information

This manual has been compiled with great care and the information it contains has been thoroughly verified. The text was correct at the time of printing, however, the content can change without notice. Bosch Security Systems accepts no liability for damage resulting directly or indirectly from faults, incompleteness or discrepancies between this manual and the product described.
Trademarks
All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
More information
For more information please contact the nearest Bosch Security Systems location or visit www.boschsecurity.com
http://www.boschsecurity.com/catalog_overview.htm
Bosch Security Systems 2015.04 | v2.0 | AM18-Q0688
10 en | System overview DINION IP ultra 8000 MP
3
3.1
3.2

System overview

Performance

The DINION IP ultra 8000 MP with 12 megapixel resolution offers crisp, clear and extremely detailed images for the most demanding IP video surveillance requirements. It captures 12 megapixel at 20 fps, and 4K UHD at 30 fps, so providing images of fast moving objects in high resolutions. The content-rich image allows effective retrospective analysis at the level of detail that makes the difference when collecting forensic evidence. The camera offers a wide-angle overview and multiple focus points on a single screen so now you can focus on details without losing the bigger picture. This IP camera operates as a network video server to transmit video and control signals over Ethernet LANs and the Internet. The integrated encoder uses H.264 compression technology to give clear images while reducing bandwidth and storage requirements.

Lens options

Versions
The camera is available in the following versions: – Camera body with permanently attached 5 mm lens. – Camera body with permanently attached 3.2 mm lens. – Camera body with C/CS lens mount and motorized focus
adjustment. Three telephoto lenses (75 mm, 50 mm and 35 mm), specifically matched to the camera body, are optionally available.
2015.04 | v2.0 | AM18-Q0688 Bosch Security Systems
DINION IP ultra 8000 MP System overview | en 11
3.3
3.4

Application variants

The camera has a choice of application variants that set up the camera for optimum performance in a specific environment. Select the application variant best suited to your installation. The application variant must be selected before any other changes are made, as the camera reboots automatically and resets the factory defaults when the application variant is changed. The DINION IP ultra 8000 MP has three application variants: – 4K UHD – 12MP (4:3) – 1080p

Using the camera

To access the features of the camera, use a web browser. The browser provides live viewing of the camera streams in the interface window, and also allows you to access and change the extensive list of settings and parameters for camera configuration. Refer to the software manual for more information on the browser interface. The camera recording and storage functions include local alarm recording and recording to iSCSI-based systems. The camera can also use the Bosch Video Recording Manager (VRM) to control recording and storage. Integration with the many Bosch recording solutions is seamless.
3.5
Bosch Security Systems 2015.04 | v2.0 | AM18-Q0688

Operation with external systems

Using a web browser to access the camera’s video streams and functions is the most direct way of using the camera. The Bosch Video Client can be downloaded and used for multiple­camera viewing, playback and configuration. A Bosch Video Security App is also available for remote viewing. If the camera is used in larger surveillance systems, the Bosch Video Management System offers a perfect integrated solution.
en | System overview DINION IP ultra 8000 MP
12
Third-party integrators can easily access the internal feature set of the camera for integration into large projects. Access to IVA metadata is available to integrators via RTSP. When connected to external systems, many of the camera configuration parameters are controlled by the system and not by the settings made via a web browser.
Bosch Video Client
The Bosch Video Client is a free Windows application to view, operate, control, and administer surveillance cameras and installations at remote locations. It offers a user-friendly interface for easy live viewing of multiple cameras, playback, forensic search and export.
Video Security Client
The Video Security Client is a free, easy-to-use video-surveillance application provided by Bosch for local and remote monitoring of IP cameras and appliances. The software supports systems up to 16 cameras.
IP Helper
The IP Helper tool is a free PC application that makes it easy to detect Bosch cameras and devices on your network.
Download store
Download the latest applications and firmware from: http://downloadstore.boschsecurity.com/
Bosch Video Management System
The Bosch Video Management System is a unique enterprise IP video surveillance solution that provides seamless management of digital video, audio and data across any IP network. It is designed to work with Bosch security products as part of a total video surveillance management system.
2015.04 | v2.0 | AM18-Q0688 Bosch Security Systems
DINION IP ultra 8000 MP Planning | en 13
4
4.1
4.2

Planning

Unpacking

This equipment should be unpacked and handled with care. If an item appears to have been damaged in shipment, notify the shipper immediately. Verify that all parts are included. If any items are missing, notify your Bosch Security Systems Sales or Customer Service Representative. The original packaging is the safest container in which to transport the unit and can be used if returning the unit for service.

Contents

The packaging contains: – DINION IP 8000 camera – Quick install instructions – Power connector – Data/Alarm connector – Identification labels – C/CS mount adapter ring for mounting a lens with a C-
mount (not supplied for factory fitted lenses)
Bosch Security Systems 2015.04 | v2.0 | AM18-Q0688
14 en | Planning DINION IP ultra 8000 MP
4.3

System requirements

To enjoy the full benefits of megapixel resolutions, ensure that the computer, the graphic adapter, the display connections, and the monitor are sufficiently powerful to view our camera images at their best. Our minimum recommendations are: – Computer with Dual core HyperThreading processor or
better – 4K capable graphic card – Windows 7 or later operating system – Network access – Internet Explorer version 11 or later
– or –
Application software, for example, Video Security Client
Bosch Video Client or Bosch Video Management System.
Notice!
Megapixel cameras can generate high bitrate streams. Ensure
that your network can handle high volume traffic and that you
use a powerful, high performance computer.
2015.04 | v2.0 | AM18-Q0688 Bosch Security Systems
C/CS
adapter
DINION IP ultra 8000 MP Installation | en 15
5
5.1

Installation

Lens mounting

The factory-mounted lenses are already calibrated and do not need any adjustments. There are three telephoto lenses optionally available for the camera body version: – a 35 mm lens (LFF-8012C-D35) – a 50 mm lens (LFF-8012C-D50) – a 75 mm lens (LFF-8012C-D75) The separate camera body includes an auto-focus lens wizard to ensure that lenses can be easily focused. The automatic motorized focus adjustment with 1:1 pixel mapping ensures that the camera with these telephoto lenses is always focused accurately.
Notice!
Do not try to adjust a factory-fitted lens.
Do not allow dust to get onto the sensor or lens surface.
Lenses weighing more than 0.5 kg (1.1lbs) must be separately
supported.
To attach a lens to the camera:
1. Remove the sensor protection cap from the camera.
2. For C-mount lenses, screw the C/CS lens adapter ring onto the camera.
3. Screw the lens onto the camera.
Bosch Security Systems 2015.04 | v2.0 | AM18-Q0688
1/4”-20 UNC
16 en | Installation DINION IP ultra 8000 MP
5.2

Mounting the camera

Notice!
Do not expose the image sensors to direct sunlight.
Do not obstruct the free flow of air around the camera.
The camera can be mounted either from the top or from the bottom (1/4" 20 UNC thread).
Note:
Do not mount the camera upside-down.
2015.04 | v2.0 | AM18-Q0688 Bosch Security Systems
Loading...
+ 36 hidden pages