Bosch NBN-498-21P Operation Manual

Dinion2X IP Camera
NBN-498
en Installation and Operation Manual
Dinion2X IP Camera Table of Contents | en 3
Table of Contents
1.1 Safety precautions 8
1.2 Important safety instructions 9
1.3 Connection in applications 10
1.4 FCC & ICES compliance 11
1.5 UL certification 13
1.6 Bosch notices 14
1.7 Copyrights 15
2 Introduction 16
2.1 Features 16
3 System Information 18
3.1 Overview of functions 18
3.1.1 Progressive scan 18
3.1.2 Day/Night function 18
3.1.3 Wide dynamic range 18
3.1.4 Tri-streaming 19
3.1.5 ONVIF (Open Network Video Interface Forum) 19
3.1.6 Audio 19
3.1.7 Alarm I/O 19
3.1.8 Tamper detection and motion detectors 19
3.1.9 Video encoding 19
3.1.10 Multicast 19
3.1.11 Power-over-Ethernet 20
3.1.12 Encryption 20
3.1.13 Receiver 20
3.1.14 Recording 20
3.1.15 Snapshots 20
3.1.16 Backup 20
3.1.17 Configuration 20
3.2 Operation with external systems 22
Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06
4 en | Table of Contents Dinion2X IP Camera
4 Planning 24
4.1 Unpacking 24
4.2 System requirements 25
4.3 Install players 26
5 Installation 27
5.1 Network (and power) connector 27
5.2 Power connector 28
5.3 Alarm and relay connector 29
5.4 Audio connectors 30
5.5 Video service monitor connector 31
5.6 Data connector 32
5.7 Lens mounting 33
5.8 Mounting the camera 34
5.9 Using the camera install menu 35
5.10 Back focus adjustment 35
5.11 Lens adjustment 36
5.11.1 DC-iris lens 36
5.11.2 Manual-iris lens 36
5.11.3 Video-iris lens 37
5.12 Reset button 37
6 Camera set-up 38
6.1 Camera menu navigation 38
6.2 Install menu 39
6.2.1 Pre-defined modes 39
6.2.2 Lens Wizard submenu 40
6.2.3 Network submenu 41
6.2.4 Defaults submenu 41
6.3 Day/Night switching 42
7 Browser connection 43
7.1 System requirements 43
7.2 Establishing the connection 44
7.2.1 Password protection in camera 44
AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems
Dinion2X IP Camera Table of Contents | en 5
7.3 Protected network 44
7.4 Connecting to a hardware decoder 45
7.4.1 Alarm connection 45
7.5 Connection established 46
7.5.1 LIVEPAGE 46
7.5.2 RECORDINGS 46
7.5.3 SETTINGS 46
8 Basic Mode 48
8.1 Basic Mode menu tree 48
8.2 Device Access 49
8.2.1 Camera name 49
8.2.2 Password 49
8.3 Date/Time 50
8.4 Network 51
8.5 Encoder Profile 52
8.6 Audio 52
8.7 Recording 52
8.7.1 Storage medium 52
8.8 System Overview 52
9 Advanced Mode 53
9.1 Advanced Mode menu tree 53
9.2 General 55
9.2.1 Identification 55
9.2.2 Password 55
9.2.3 Date/Time 56
9.2.4 Display Stamping 58
9.3 Web Interface 60
9.3.1 Appearance 60
9.3.2 LIVEPAGE Functions 61
9.3.3 Logging 62
9.4 Encoder 63
9.4.1 Privacy Masks 63
9.4.2 Encoder Profile 63
9.4.3 Encoder Streams 67
Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06
6 en | Table of Contents Dinion2X IP Camera
9.5 Audio 68
9.6 Camera 69
9.6.1 Mode 69
9.6.2 ALC 70
9.6.3 Shutter/AGC 71
9.6.4 Day/night 72
9.6.5 Enhance 73
9.6.6 Color 74
9.6.7 Installer Options 75
9.7 Recording 77
9.7.1 Storage Management 77
9.7.2 Recording Profiles 80
9.7.3 Retention Time 81
9.7.4 Recording Scheduler 82
9.7.5 Recording Status 83
9.8 Alarm 84
9.8.1 Alarm Connections 84
9.8.2 Video Content Analyses (VCA) 87
9.8.3 VCA configuration- Profiles 88
9.8.4 VCA configuration - Scheduled 94
9.8.5 VCA configuration - Event triggered 96
9.8.6 Audio Alarm 97
9.8.7 Alarm E-Mail 98
9.8.8 Alarm Task Editor 100
9.9 Interfaces 101
9.9.1 Alarm input 101
9.9.2 Relay 101
9.9.3 COM1 102
9.10 Network 103
9.10.1 Network 103
9.10.2 Advanced 107
9.10.3 Multicasting 108
9.10.4 JPEG Posting 109
9.10.5 Encryption 110
9.11 Service 111
9.11.1 Maintenance 111
9.11.2 Licenses 113
AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems
Dinion2X IP Camera Table of Contents | en 7
9.11.3 System Overview 113
10 Operation via the browser 114
10.1 Livepage 114
10.1.1 Processor load 114
10.1.2 Image selection 115
10.1.3 View Control 115
10.1.4 Digital I/O 115
10.1.5 System Log / Event Log 115
10.1.6 Saving snapshots 115
10.1.7 Recording video sequences 116
10.1.8 Running recording program 116
10.1.9 Audio communication 116
10.2 Recordings page 117
10.2.1 Controlling playback 117
11 Troubleshooting 119
11.1 Function test 119
11.2 Resolving problems 120
11.3 Customer service 122
12 Maintenance 123
12.1 Testing the network connection 123
12.2 Communication with Terminal Program 123
12.3 Repairs 125
12.3.1 Transfer and disposal 125
13 Technical Data 126
13.1 Specifications 126
13.1.1 Dimensions 129
13.1.2 Accessories 130
Glossary 131
Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06
8 en | Safety Dinion2X IP Camera
1Safety
1.1 Safety precautions
DANGER!
High risk: This symbol indicates an imminently hazardous situation such as "Dangerous Voltage" inside the product. If not avoided, this will result in an electrical shock, serious bodily injury, or death.
WARNING!
Medium risk: Indicates a potentially hazardous situation. If not avoided, this could result in minor or moderate bodily injury.
CAUTION!
Low risk: Indicates a potentially hazardous situation. If not avoided, this could result in property damage or risk of damage to the unit.
AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems
Dinion2X IP Camera Safety | en 9
1.2 Important safety instructions
Read, follow, and retain for future reference all of the following safety instructions. Follow all warnings on the unit and in the operating instructions before operating the unit.
1. Clean only with a dry cloth. Do not use liquid cleaners or aerosol cleaners.
2. Do not install unit near any heat sources such as radiators, heaters, stoves, or other equipment (including amplifiers) that produce heat.
3. Never spill liquid of any kind on the unit.
4. Take precautions to protect the unit from power and lightning surges.
5. Adust only those controls specified in the operating instructions.
6. Operate the unit only from the type of power source indicated on the label.
7. Unless qualified, do not attempt to service a damaged unit yourself. Refer all servicing to qualified service personnel.
8. Install in accordance with the manufacturer's instructions in accordance with applicable local codes. Use only attachments/accessories specified by the manufacturer. Equipment change or modification could void the user's guarantee or authorization agreement.
Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06
10 en | Safety Dinion2X IP Camera
1.3 Connection in applications
Power lines: An outdoor system should not be located in the
vicinity of overhead power lines, electrical lights, or power circuits, or where it may contact such power lines or circuits. When installing an outdoor system, extreme care should be taken to keep from touching power lines or circuits, as this contact may be fatal. U.S.A. models only - refer to the National Electrical Code Article 820 regarding installation of CATV systems. 12 VDC / 24 VAC power source: This unit is intended to operate with a limited power source. The unit is intended to operate at either 12 VDC or 24 VAC (if PoE is not available). User supplied wiring must be in compliance with electrical codes (Class 2 power levels). If 24 VAC is used, do not ground the 24 VAC supply at the terminals or at the unit's power supply terminals. PoE: Use only approved PoE devices. Power-over-Ethernet can be connected at the same time as a 12 VDC or 24 VAC power supply.
CAUTION!
The Low Voltage power supply unit must comply with EN/UL
60950. The power supply must be a SELV-LPS unit or a SELV ­Class 2 unit (Safety Extra Low Voltage - Limited Power Source).
AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems
Dinion2X IP Camera Safety | en 11
1.4 FCC & ICES compliance
FCC & ICES Information
(U.S.A. and Canadian Models Only)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – reorient or relocate the receiving antenna; – increase the separation between the equipment and
receiver;
connect the equipment into an outlet on a circuit different
from that to which the receiver is connected;
consult the dealer or an experienced radio/TV technician
for help.
Intentional or unintentional modifications, not expressly approved by the party responsible for compliance, shall not be made. Any such modifications could void the user's authority to operate the equipment. If necessary, the user should consult the dealer or an experienced radio/television technician for corrective action. The user may find the following booklet, prepared by the Federal Communications Commission, helpful: How to Identify and Resolve Radio-TV Interference Problems. This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.
Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06
12 en | Safety Dinion2X IP Camera
Informations FCC et ICES
(modèles utilisés aux États-Unis et au Canada uniquement)
Suite à différents tests, cet appareil s'est révélé conforme aux exigences imposées aux appareils numériques de classe B, en vertu de la section 15 du règlement de la Commission fédérale des communications des États-Unis (FCC), et en vertu de la norme ICES-003 d'Industrie Canada. Ces exigences visent à fournir une protection raisonnable contre les interférences nuisibles lorsque l'appareil est utilisé dans le cadre d'une installation résidentielle. Cet appareil génère, utilise et émet de l'énergie de radiofréquences et peut, en cas d'installation ou d'utilisation non conforme aux instructions, engendrer des interférences nuisibles au niveau des radiocommunications. Toutefois, rien ne garantit l'absence d'interférences dans une installation particulière. Il est possible de déterminer la production d'interférences en mettant l'appareil successivement hors et sous tension, tout en contrôlant la réception radio ou télévision. L'utilisateur peut parvenir à éliminer les interférences éventuelles en prenant une ou plusieurs des mesures suivantes: – Modifier l'orientation ou l'emplacement de l'antenne
réceptrice; – Éloigner l'appareil du récepteur; – Brancher l'appareil sur une prise située sur un circuit
différent de celui du récepteur; – Consulter le revendeur ou un technicien qualifié en radio/
télévision pour obtenir de l'aide. Toute modification apportée au produit, non expressément approuvée par la partie responsable de l'appareil, est strictement interdite. Une telle modification est susceptible d'entraîner la révocation du droit d'utilisation de l'appareil. La brochure suivante, publiée par la Commission fédérale des communications (FCC), peut s'avérer utile : Comment identifier et résoudre les problèmes d’interférences de radio et de télévision. Cette brochure est disponible auprès du U.S. Government Printing Office, Washington, DC 20402, États-Unis, sous la référence n° 004-000-00345-4.
AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems
Dinion2X IP Camera Safety | en 13
1.5 UL certification
Disclaimer
Underwriter Laboratories Inc. ("UL") has not tested the performance or reliability of the security or signaling aspects of this product. UL has only tested fire, shock and/or casualty hazards as outlined in UL's Standard(s) for Safety for Information Technology Equipment, UL 60950-1. UL Certification does not cover the performance or reliability of the security or signaling aspects of this product. UL MAKES NO REPRESENTATIONS, WARRANTIES, OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING RELATED FUNCTIONS OF THIS PRODUCT.
Disposal - Your Bosch product was developed and manufactured with high-quality material and components that can be recycled and reused. This symbol means that electronic and electrical appliances, which have reached the end of their working life, must be collected and disposed of separately from household waste material. Separate collecting systems are usually in place for disused electronic and electrical products. Please dispose of these units at an environmentally compatible recycling facility, per European
Directive 2002/96/EC
Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06
14 en | Safety Dinion2X IP Camera
1.6 Bosch notices
Video loss
Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To minimize the risk of lost digital information, Bosch Security Systems recommends multiple, redundant recording systems, and a procedure to back up all analog and digital information.
Copyright
This manual is the intellectual property of Bosch Security Systems and is protected by copyright. All rights reserved.
Trademarks
All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
Note
This manual has been compiled with great care and the information it contains has been thoroughly verified. The text was complete and correct at the time of printing. The ongoing development of the products may mean that the content of the user guide can change without notice. Bosch Security Systems accepts no liability for damage resulting directly or indirectly from faults, incompleteness or discrepancies between the user guide and the product described.
More information
For more information please contact the nearest Bosch Security Systems location or visit www.boschsecurity.com
AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems
Dinion2X IP Camera Safety | en 15
1.7 Copyrights
The firmware 4.1 uses the fonts "Adobe-Helvetica-Bold-R­Normal--24-240-75-75-P-138-ISO10646-1" and "Adobe­Helvetica-Bold-R-Normal--12-120-75-75-P-70-ISO10646-1" under the following copyright: Copyright 1984-1989, 1994 Adobe Systems Incorporated. Copyright 1988, 1994 Digital Equipment Corporation. Permission to use, copy, modify, distribute and sell this software and its documentation for any purpose and without fee is hereby granted, provided that the above copyright notices appear in all copies and that both those copyright notices and this permission notice appear in supporting documentation, and that the names of Adobe Systems and Digital Equipment Corporation not be used in advertising or publicity pertaining to distribution of the software without specific, written prior permission.
This software is based in part on the work of the Independent JPEG Group.
Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06
16 en | Introduction Dinion2X IP Camera
2 Introduction
2.1 Features
The Dinion2x IP Day/Night camera is a high-performance, smart surveillance color camera. It incorporates 20-bit digital signal processing and a wide dynamic range sensor for outstanding picture performance under all lighting conditons. The camera uses H.264 compression technology to give clear images while reducing bandwidth and storage requirements. It is also ONVIF compliant to improve compatibility during system integration. The camera operates as a network video server and transmits video and control signals over data networks, such as Ethernet LANs and the Internet. The camera is easy to install and ready to use. Features include: – Progressive scan – True Day/Night performance with switchable IR filter – 1/3-inch CCD sensor with wide dynamic range – Tri-streaming (two H.264 streams and one M-JPEG stream) – Complies with the ONVIF standard for wide compatibility – Two-way audio and audio alarm – Alarm input and alarm output to external devices – Dynamic engine with Smart BLC – Six pre-programmed operation modes – Adaptive dynamic noise reduction – Enhanced video motion detection – Video and data transmission over IP data networks – Multicast function for simultaneous picture transmission to
multiple receivers – Integrated Ethernet interface (10/100 Base-T) – Power-over-Ethernet (PoE) – Remote control of all built-in functions via TCP/IP – Data interface RS485/RS422/RS232 for control of pan or
tilt heads or motorized zoom lenses (PTZ control)
AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems
Dinion2X IP Camera Introduction | en 17
Password protection to prevent unauthorized connection
or configuration changes
Event-driven, automatic connection (for example, at
switch-on and for alarms)
Fast, convenient configuration using the integrated Web
server and a browser – Firmware update through flash memory – Convenient upload and download of configuration data
Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06
18 en | System Information Dinion2X IP Camera
3 System Information
3.1 Overview of functions
The camera incorporates a network video server. Its primary function is to encode video and control data for transmission over an IP network. With its H.264 encoding, it is ideally suited for IP communication and for remote access to digital video recorders and IP systems. The use of existing networks means that integration with CCTV systems or local networks can be achieved quickly and easily. Video images from a single camera can be simultaneously received on several receivers.
3.1.1 Progressive scan
The camera captures and processes progressively scanned images. When there is fast motion in a scene, progressively scanned images are generally sharper than interlaced images.
3.1.2 Day/Night function
The Day/Night function provides enhanced night viewing by increasing the IR sensitivity. The motorized IR filter can be removed in low-light or IR illuminated applications. The IR filter switches from color to monochrome automatically by sensing the illumination level. In auto switching mode the camera prioritizes motion (the camera gives sharp images without motion blur) or color (the camera gives color pictures as long as the light level permits).
3.1.3 Wide dynamic range
A unique combination of 20-bit digital video processing that enhances sensitivity and 2X-Dynamic which extends the dynamic range, provides a sharper, more detailed image with outstanding accuracy in color reproduction. The 20-bit digital signal is automatically processed to optimally capture the detail in both the high and low light areas of the scene simultaneously, maximizing the information visible in the picture.
AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems
Dinion2X IP Camera System Information | en 19
3.1.4 Tri-streaming
Tri-streaming allows the data stream to be encoded simultaneously according to three different, individually customized profiles. This creates two full H.264 streams that can serve different purposes and an additional M-JPEG stream.
3.1.5 ONVIF (Open Network Video Interface Forum)
The camera complies to the ONVIF standard which means that it is easier to install and integrate into larger systems. The ONVIF standard is a global standard for the interface of network video products.
3.1.6 Audio
Two-way duplex audio is available in the unit for live voice communications or audio recording.
3.1.7 Alarm I/O
The alarm input can be used to control the functionality of the unit. An alarm output can control external devices.
3.1.8 Tamper detection and motion detectors
The camera offers a wide range of configuration options for alarm signaling in the event of tampering with the camera. An algorithm for detecting movement in the video image is also part of the scope of delivery and can optionally be extended to include special video analysis algorithms.
3.1.9 Video encoding
The camera uses the H.264 compression standards. Thanks to efficient encoding, the data rate remains low even with high image quality and can also be adapted to local conditions within wide limits.
3.1.10 Multicast
In suitably configured networks, the multicast function enables simultaneous, real time transmission to multiple receivers. The prerequisite for this is that the UDP and IGMP V2 protocols are implemented on the network.
Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06
20 en | System Information Dinion2X IP Camera
3.1.11 Power-over-Ethernet
Power for the camera can be supplied via a Power-over­Ethernet compliant network cable connection. With this configuration, only a single cable connection is required to view, power, and control the camera.
3.1.12 Encryption
The unit offers a variety of options for protection against unauthorized reading. Web browser connections can be protected using HTTPS. Protect the control channels via the SSL encryption protocol. With an additional license, the user data itself can be encrypted.
3.1.13 Receiver
H.264 compatible hardware decoders can be used as a receiver. Computers with decoding software such as VIDOS, or computers with the Microsoft Internet Explorer web browser installed, can also be used as receivers.
3.1.14 Recording
The camera can be used with an iSCSI server connected via the network to store long-term recordings.
3.1.15 Snapshots
Individual video frames (snapshots) can be called up as JPEG images, stored on the hard drive, or displayed in a separate browser window.
3.1.16 Backup
The browser application has an icon for saving the video images provided by the unit as a file on your computer's hard drive. Clicking this icon stores the video sequences and they can be replayed with the Player from Bosch Security Systems included with the package.
3.1.17 Configuration
The camera can be configured using a browser on the local network (Intranet) or from the Internet. Similarly, firmware updates and rapid loading of device configurations are also
AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems
Dinion2X IP Camera System Information | en 21
possible. Configuration settings can be stored as files on a computer and copied from one camera to another.
Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06
22 en | System Information Dinion2X IP Camera
3.2 Operation with external systems
The camera can be used with a variety of Bosch software and hardware systems: – Bosch Video Management System –VIDOS video management software – DiBos 900 Series digital video recorder – Divar 700 Series digital video recorder
Note:
When connected to any of these systems, many of the camera configuration parameters are controlled by the system and not by the settings made via a web browser connected to the camera.
Bosch Video Management System
The Bosch Video Management System is a unique enterprise IP video surveillance solution that provides seamless management of digital video, audio, and data across any IP network. It is designed to work with Bosch CCTV products as part of a total video surveillance management system. Integrate your existing components into one easy-to-manage system, or use Bosch’s full-line capabilities and benefit from a complete surveillance solution based on cutting-edge technology and years of experience.
VIDOS
The camera video server and VIDOS software combine to provide a high-performance system solution. VIDOS is software for operating, controlling, and administering CCTV installations (such as surveillance systems) at remote locations. It runs under Microsoft Windows operating systems. Its main job is decoding video, audio, and control data from a remote transmitter. There are many options available for operation and configuration when using a camera with VIDOS.
DiBos 900 Series
The camera is also designed for use with DiBos 900 Series Video Recorders. DiBos can record up to 32 video and audio
AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems
Dinion2X IP Camera System Information | en 23
streams, and is available as software or as a hybrid DVR with additional analog camera and audio inputs. DiBos supports various functions of the camera, such as controlling relays, remote control of peripheral devices, and remote configuration. DiBos can use alarm inputs to trigger actions and, when motion detection Motion+ is active, can record the relevant cells, making intelligent motion detection possible.
Divar 700 Series
The Divar 700 Series of digital video recorders can view and record images from the camera via a network connection. The Divar 700 Series controls the camera so that the correct settings are used.
Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06
24 en | Planning Dinion2X IP Camera
4 Planning
4.1 Unpacking
Unpack carefully and handle the equipment with care. The packaging contains: – Dinion2X IP camera – CCD protection cap (mounted on camera) – Power connector – Alarm I/O connector – Data connector – Spare lens connector (male) – DVD ROM (mini)
–Manual – System requirements – Configuration Manager – BVIP Lite Suite –MPEG ActiveX control – DirectX control – Microsoft Internet Explorer –Sun JVM – Player and Archive Player
Adobe Acrobat Reader – Quick install instructions – Safety instructions If equipment has been damaged during shipment, repack it in the original packaging and notify the shipping agent or supplier.
AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems
Dinion2X IP Camera Planning | en 25
4.2 System requirements
Computer with Windows XP/Vista operating system,
network access, and Microsoft Internet Explorer web browser version 7.0 or later or
Computer with Windows XP/Vista operating system,
network access and reception software, for example VIDOS, Bosch VMS, or DIBOS 900 Series or
H.264 compatible hardware decoder from
Bosch Security Systems (such as VIP XD) as a receiver and a connected video monitor or
Divar 700 Series Digital Video Recorder
The minimum PC requirements are: – Operating platform: A PC running Windows XP or
Windows Vista with IE 7.0 – Processor: Dual core, 3.0 GHz – RAM memory: 256 MB – Monitor resolution: 1024 x 768 – Network interface: 100-BaseT –DirectX: 9.0c Make sure the graphics card is set to 16-bit or 32-bit color depth and that Sun JVM is installed on your PC. To play back live video images, an appropriate ActiveX must be installed on the computer. If necessary, install the required software and controls from the product DVD provided. For further assistance, contact your PC system administrator.
Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06
26 en | Planning Dinion2X IP Camera
4.3 Install players
Play back saved-video sequences using the Player from Bosch Security Systems. This can be found on the DVD-ROM supplied. to play back saved sequences using the Player, suitable ActiveX software must be installed on the computer.
1. Insert the DVD into the DVD-ROM drive of the computer. If the DVD does not start automatically, open the DVD in Windows Explorer and double-click the index.html file to start the installation.
2. Select a language from the list box at the top.
3. Click Tools in the menu.
4. Click Archive Player; the installation starts.
5. Follow the instructions in the installation program. The Archive Player is installed together with the Player.
6. After a successful installation, two new icons for the Player and the Archive Player appear on the desktop.
7. Double-click the Player icon to start the Player.
AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems
Dinion2X IP Camera Installation | en 27
5 Installation
CAUTION!
Installation should only be performed by qualified service personnel in accordance with the National Electrical Code or applicable local codes.
5.1 Network (and power) connector
AUDIO IN
ALARM
1 2 3
VIDEO
UTP Cat 5 RJ45
AUDIO OUT
E
4
T
5
H
6
P o E
+
12 VDC 24 VAC
DATA
1
4
2
5
3
6
Figure 5.1 Network connection
Connect the camera to a 10/100 Base-T network. – Use screened UTP Category 5e cable with RJ45 connectors
(the camera network socket is Auto MDIX compliant).
Power can be supplied to the camera via the Ethernet
cable compliant with the Power-over-Ethernet
(IEEE 802.3af) standard. The multicolored LED beside the Ethernet connection indicates Power (red), IP connection (green) and IP traffic (green flashing). It can be disabled in the Settings/Camera Settings/ Install options menu. By default, power is supplied to the camera via the Ethernet cable, compliant with the Power-over-Ethernet standard.
Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06
28 en | Installation Dinion2X IP Camera
5.2 Power connector
AUDIO IN
AUDIO OUT
E T H
P o E
5 mm
0.2 in
+
12 VDC 24 VAC
DATA
1
4
2
5
3
6
ALARM
1
4
2
5
3
6
VIDEO
Figure 5.2 Power connection
Connect power from a 24 VAC or 12 VDC class 2 power supply as follows: – Use AWG16 to 22 stranded wire or AWG16 to 26 solid
wire; cut back 5 mm (0.2 in) of insulation.
Loosen the screws of the supplied 2-pole connector and
insert the wires.
Tighten the screws and insert the 2-pole connector into
the power socket of the camera.
Note:
For a DC supply the polarity is important. Incorrect polarity does not damage the camera but it will not switch on.
AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems
Dinion2X IP Camera Installation | en 29
Alarm
1
2
3
4
5
6
5 mm
(0.2 in)
5.3 Alarm and relay connector
Figure 5.3 Alarm and relay connector pins
Pin Alarm socket
1 Alarm in 1 2 Alarm in 2 3 Relay out contact 1 4Ground 5Ground 6 Relay out contact 2
Max. wire diameter AWG 22-28 for both stranded and
solid; cut back 5 mm (0.2 in) of insulation. – Alarm output relay switching capability: Max voltage 30VAC
or +40 VDC. Max 0.5 A continuous, 10 VA. – Alarm in: TTL logic, +5V nominal, +40 VDC max, DC coupled
with 22 kOhm pull-up to +3.3 V. – Alarm in: configurable as active low or active high. – Max. 42 V allowed between camera ground and each of the
relay pins. Use the alarm input to connect external alarm devices such as door contacts or sensors. A zero potential make-contact or switch can be used as the actuator (use a bounce-free contact system). Use the alarm relay output for switching external devices such as lamps or sirens.
Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06
30 en | Installation Dinion2X IP Camera
5.4 Audio connectors
Line
GND
AUDIO IN
AUDIO OUT
ALARM
E
1
4
T
2
5
H
3
6
P
VIDEO
o E
Figure 5.4 Audio connectors
Connect audio devices to the Audio In and Audio Out connectors.
The unit has full-duplex mono audio. The two-way communication can be used to connect a speaker or door intercom system. The audio input signal is transmitted in sync. with the video signal.
+
12 VDC 24 VAC
DATA
1
4
2
5
3
6
Audio input: Line input level (not suitable for direct microphone signal); impedance 9 kOhm typical; 5.5 Vpp maximum input voltage. Audio output: Line output level (not suitable for direct speaker connection); impedance 16 Ohm minimum; 3 Vpp maximum output voltage. Wiring: Shielded audio connection cable is advised. Observe maximum cable lengths for audio line input and output levels.
AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems
Loading...