•The Safety section describes important procedures
that can ensure your safety while using the appliance.
•The Getting Started section describes the features and
functionality of the appliance, including a description of
how to set it up and operate it.
•The Operation section describes how to operate and
get the best performance out of each component.
•The Cleaning and Maintenance section describes how
to clean and maintain the appliance.
•The Service section includes troubleshooting tips and
your warranty.
•Before using your appliance, be sure to read this
manual. Pay special attention to the Important Safety Instructions located at the beginning of the manual.
9 WARNING
This indicates that death or serious injuries may
occur as a result of non-observance of this warning.
9 CAUTION
This indicates that minor or moderate injuries may
occur as a result of non-observance of this warning.
NOTICE: Ths indicates that damage to the appliance or
property may occur as a result of non-compliance with this
advisory.
Note: This alerts you to important information and/or tips.
English 1
9IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
Safety
WARNING:
If the information in this manual is not followed exactly, fire
or shock may result causing property damage or personal
injury.
PLEASE READ ALL INSTRUCTIONS BEFORE USING
THIS APPLIANCE
9 WARNING
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or death.
Do not store or use combustible materials,
gasoline or other flammable vapors and liquids
in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
•Do not try to light any appliance.
•Do not touch any electrical switch.
•Do not use any phone in your building.
•Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call
fire department.
Installation and service must be performed by a
qualified installer.
Propane Gas Installation
•The propane gas tank must be equipped with its own
high pressure regulator. In addition, the regulator supplied with this unit must also be used.
The appliance is shipped from the factory for use with
natural gas. It must be converted for use with propane. A
qualified technician or installer must do the conversion.
9 WARNING
TIP OVER HAZARD!
A child or adult can tip the
range over and be killed.
Verify that the anti-tip
bracket is securely installed.
Ensure the anti-tip bracket
is engaged whenever the
range is moved to a new
location.
Do not operate the range without the anti-tip bracket
in place. Failure to follow the instrucitons. in this
manual can result in death or serious burns to
children and adults.
Check for proper installation and use of the anti-tip
bracket. Carefully tip the range forward pulling from
the back to ensure that the anti-tip bracket engages
the range leg and prevents tip-over. Range should
not move more than 1” (2.5 cm).
•This appliance has been CSA certified for safe operation up to a height of 10,000 ft. without any modifications. Exception: For use with propane the appliance
must be converted per the LP conversion instructions.
•For Massachusetts installations:
•Installation must be performed by a qualified or
licensed contractor, plumber or gas fitter qualified
or licensed by the state, province or region where
this appliance is being installed.
•Shut-off valve must be a "T" handle gas cock.
•Flexible gas connector must not be longer than 36
inches.
•Installer - show the owner where the gas shut-off valve
is located.
WARNING:
Do not repair or replace any part of the appliance unless
specifically recommended in the manuals. Improper
installation, service or maintenance can cause injury or
property damage. Refer to this manual for guidance. All
other servicing should be done by a qualified technician.
•Ask your dealer to recommend a qualified
technician and an authorized repair service.
•Install only per the installation instructions
provided in the literature package accompanying
this range.
•Never modify or alter the construction of the range
including by removing leveling legs, panels, wire
covers, anti-tip brackets or screws, or any other
part of the appliance.
English 2
9IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
Appliance Handling Safety
9 CAUTION
•Unit is heavy and requires at least two persons
or proper equipment to move.
•Hidden surfaces may have sharp edges. Use
caution when reaching behind or under
appliance.
•Do not use the oven or warming drawer (if
equipped) for storage.
Do not lift appliance by the oven door handle. Remove the
oven door for easier handling and installation. See the
section “Removing the Oven Door” in the range Use and
Care manual.
Unit is heavy and requires at least two people or proper
equipment to move.
Hidden surfaces may have sharp edges. Use caution when
reaching behind or under appliance.
Disposing of Packaging Materials
Remove all tape and packaging before using the range.
Destroy the carton and plastic bags after unpacking the
range. Never allow children to play with packaging
materials.
Safety Codes and Standards
This appliance complies with one or more of the following
Standards:
•UL 858, Household Electric Ranges
•CAN/CSA-C22.2 No. 61 Household Cooking Ranges
It is the responsibility of the owner and the installer to
determine if additional requirements and/or standards
apply to specific installations.
Installation Location
Child Safety
Do not store items of interest to children in the cabinets
above the range or on the backguard of a range. Children
climbing on the range to reach items could be seriously
injured.
Electric Safety
Before you plug in an electrical cord, be sure all controls
are in the OFF position.
Be sure your appliance is properly installed and grounded
by a qualified technician in accordance with the National
Electrical Code ANSI/NFPA 70 latest edition and local
electrical code requirements.
Local codes vary. Installation, electrical connections and
grounding must comply with all applicable codes.
For appliances equipped with a cord and plug, do not cut or
remove the ground prong. It must be plugged into a
matching grounding type receptacle to avoid electrical
shock. If there is any doubt as to whether the wall
receptacle is properly grounded, the customer should have
it checked by a qualified electician.
If required by the National Electrical Code (or Canadian
Electrical Code), this appliance must be installed on a
separate branch circuit.
Only a power supply cord kit rated for this appliance and
marked “for use with ranges” shall be used.
Installer - show the owner the location of the circuit
breaker or fuse. Mark it for easy reference.
Important - Save these instructions for the local electrical
inspector's use.
Before installing, turn power OFF at the service panel. Lock
service panel to prevent power from being turned ON
accidentally.
Refer to data plate for more information. See "Data Plate"
under "Service" for data plate location.
To eliminate the risk of burns or fire by reaching over
heated surface units, cabinet storage space located above
the surface units should be avoided. If cabinet storage is to
be provided, the risk can be reduced by installing a hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinet.
Verify that cabinets above the cooktop are a maximum of
13" (330 mm) deep.
English 3
Related Equipment Safety
Remove all tape and packaging before using the appliance.
Destroy the packaging after unpacking the appliance.
Never allow children to play with packaging material.
Never modify or alter the construction of the appliance. For
example, do not remove leveling legs, panels, wire covers
or anti-tip brackets/screws.
.
9 WARNING
State of California Proposition 65 Warnings:
This product contains chemicals known to the State
of California to cause cancer, birth defects or other
reproductive harm.
IMPORTANT SAFETY NOTICE: The California Safe
Drinking and Toxic Enforcement Act requires the Governor
of California to publish a list of substances known to the
state to cause cancer, birth defects or other reproductive
harm, and requires businesses to warn customers of
potential exposure to such substances.
Conversion to Liquified Petroleum Gas
.
9 WARNING
Personal injury or death from electrical shock may
occur if the range is not installed by a qualified
installer or electrician.
Any additions, changes or conversions required in
order for this appliance to satisfactorily meet the
application needs must be made by a qualified
technician..
Your gas range model is designed to allow for L.P.
conversion by a qualified service technician. Before
installing the kit be sure to follow the L.P. Installation
Instructions carefully.
English 4
Preparation
Before You Begin
Tools and Parts Needed
•Dual Fuel models only - 40 or 50 Amp power supply
cord kit (depending on local code).
Note: Not necessary for Canadian installations, cord is
preinstalled at factory.
•Measuring Tape
•Phillips Head Screwdriver
•1-1/4" Wrench
•Pencil
•T-20 Torx Screwdriver
•Screws (2) and Anchors (2) for Anti-Tip Bracket (Style
will vary depending on mounting surface)
•Level
•Drill and Drill Bit (3/16" masonry bit for concrete
screws)
•Soapy Water
•Safety Gloves and Goggles
•Tape (Optional)
•Cloth or Cardboard (Optional - to Protect Floor)
•Pipe Wrench
•Teflon Tape
•Channel Lock Pliers
•Gas Leak Test Solution
•Gas Supply Line
•Gas Shut Off Valve
•Safety Gloves and Goggles
Parts Included
•Anti-Tip Bracket
•2 wood screws
•2 anchorless concrete screws
•Foam Tape
•Terminal Lugs (For Use With Hard Wire Installations)
Note: Terminal lugs not necessary for Canadian
installations.
Note: Power supply cord kit is not necessary for hard-wired
installations.
Remove Packaging
Remove all packaging from the appliance. This includes
external (box, tape, foam) and internal (cardboard,
packaged literature and accessories).
Installation Checklist
Please refer to the pages following for complete installation
instructions. Use this checklist to verify that you have
completed each step of the installation process. This can
help you avoid common mistakes.
___ 1. Before installing the range, be sure to verify the
cabinet dimensions are correct for your unit and
the required electrical connections are present.
___ 2. Refer to the installation manual for content
regarding Safety, Cabinet Dimensions, Remove
Packaging, Electrical Installation, Gas Connection,
Testing the Installation and Customer Service.
___ 3. (Optional) Remove the oven door to reduce the
unit weight and to provide access to handhold for
lifting.
___ 4. Move the range unit into place in front of the
installation opening, leaving the bottom packaging
on the unit to avoid damaging flooring.
___ 5. Plug the range into a properly configured
receptacle.
___ 6. Protect the flooring from damage, then slide the
unit all the way into place, making sure to route the
power cord correctly.
___ 7. Reinstall the oven door removed in step 3 above.
___ 8. Consult the complete installation instructions and
follow the remainder of the procedures listed,
including performing an operation test.
Additional Parts Needed for Hard-Wired
Installations
Dual Fuel models only
•Flexible conduit
•Torque wrench
English 5
Removing the Oven Door and
L
O
W
H
I
G
H
_
M
E
D
P
R
O
O
F
+
O
N
/
O
F
F
Warming Drawer
Optional: The oven door and warming drawer may be
removed prior to installation to make the range lighter and
easier to move. See instructions below.
Removing the Oven Door
1. Be sure to read the
above WARNING
before attempting to
remove the door.
2. Open the door
completely.
3. Flip levers on hinges
toward you.
4. Holding the door firmly
on both sides and
using both hands,
close the door gently
until it stops against
the levers, about 30º
from the closed
position.
Removing the Warming Drawer
1. Pull drawer to fully open position.
2. Press down right drawer release lever.
3. 0Lift up left drawer release lever.
4. Firmly pull the drawer straight out.
5. Retract cabinet rails while drawer is removed.
General Information
5. Carefully lift the door
up and out of the
hinge slots. Hold
firmly; the door is
heavy.
Place the door in a
convenient and stable
location unitl you are
ready to reinstall it.
6. Place the door in a
convenient and stable
location unitl you are
ready to reinstall it.
Lay the door on a
towel or section of
protective foam
padding to avoid
damage to the door or
the floor.
Overall Dimensions
DimensionInchesCentimeters
Height36”91.44 cm
Width29 5/16”74.55 cm
Depth25 5/8”65.09 cm
Location Level and Plumb
For best results, cabinets, countertops walls and floors in
the installation location should be as level and plumb as
possible. Variance may cause damage to countertops and
floors during installation, could jeopardize the seal around
the cooktop and may adversely affect cooking and baking
performance.
Installation Hints
Tape the warming door closed during installation to prevent
it from opening while the range is being installed.
Place a piece of cardboard or cloth under the range during
installation to protect floors.
To make the range lighter and easier to handle during
installation, remove the range oven door (see door
removal/reinstallation in the Use & Care Manual
maintenance section).
English 6
Gas Requirements
9 WARNING
Make certain that gas shutoff valve and all burner
controls are in the OFF position before beginning.
Shut off main gas supply valve before disconnecting the old
range and leave it off until the new hook-up has been
completed. Don’t forget to relight the pilot on other gas
appliances when you turn the gas back on.
Electrical Requirements
Refer to data plate for more information. See the product
“Data Plate” in the section on Service in this manual.
Gas Models
The 120v power cord is installed on gas ranges.
Dual Fuel Models
We recommend that the range be installed with a
power cord set (not supplied). The electrical rating
of the power cord set must be 120/240 volt, 30 amperes
minimum. The power cord set shall be marked “For Use
with Ranges.” Always use a new power cord.
Gas Models: The power cord and outlet are 120 VAC. The
120 VAC outlet can be positioned on the wall and outside
the gas connection area and below 20 in. (51 cm) from the
floor.
Dual Fuel and Gas Models: The gas connection is
accessed by removing the warming drawer. The available
space for the gas connection is shown in the grey box (G)
in the illustration following.
Note: In Canada, the range is shipped from the factory with
the range power cord already installed.
Electrical kW Rating
Ranges are dual rated for use on either 120/240 VAC or
120/208 VAC. Check the data plate for the kW rating.
Reference the kW rating in the table below to determine
amperage requirements.
VOLTS
A/C
120/2406013.040 or 50 amps*
120/2406013.840 or 50 amps*
120/208609.840 or 50 amps*
120/2086010.440 or 50 amps*
* Varies by location. Check local codes.
HZRATING
KW
CIRCUIT
BREAKER
Electric Outlet and Gas Connection
Location
Dual Fuel models: A flush mount 208/240 VAC outlet is
recommended. Use the diagram below to make sure your
installation in properly prepared for the range. Note the
grey box (E) designating the acceptable area on the wall
behind the range for the 208/240 VAC electrical outlet.
Verify that wiring to house is adequate Contact your local
utility company to verify that the present electric service to
your home is adequate. In some instances, the size of the
wiring to the house andservice switch must be increased to
handle the electrical load demanded by the range.
Verify that wiring inside house is adequate. Most wiring
codes require a separate circuit with separate disconnect
switch and fuses either in the main entrance panel or in a
separate switch and fuse box
The range requires a minimum of a three wire 120/240 or
120/208 volt, 40 or 50 AMP, 60 Hz AC circuit. Check local
codes for proper amperage ratings.A four wire connection
is preferred. Most local building regulations and codes
require that electrical wiring be done by licensed
electricians. Be sure to install your range according to the
electric codes in place in your region.
English 7
Cabinet Requirements
This unit is designed for installation near adjacent walls and
projecting surfaces constructed of combustible materials.
Prepare the countertop and cabinets.
Allow a minimum of 30" (76.2 cm) between cabinets
where range is to be installed. No side clearance is
required in the U.S. (In Canada, 12 mm clearance is
required from range sidewalls to cabinets). Height is set by
adjusting the range legs (see later section, “Complete the
installation”.
.
9 WARNING
To eliminate the risk of burns or fire by reaching over
heated surface units, cabinet storage space located
above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a hood that projects horizontally a
minimum of 5" (12.7 cm) beyond the bottom of the
cabinet.
From cooktop to materials above: There must be a
minimum clearance of 36" (91.4 mm) between the top of
the cooking surface and the bottom of an unprotected wood
or metal cabinet. The minimum clearance from the top of
the cooking surface and a vent hood or OTR microwave
hood is 30 inches (72.2 cm).
Note: The slide-in range can also replace a
freestanding range. In this case, verify that the opening is
at least 30" (76.2 cm).
Install Ventilation
Bosch strongly recommends the installation of a ventilation
hood above this range. For most kitchens a certified hood
rating of not less than 300 CFM is recommended. The
range hood must be installed according to instrutions
furnished with the hood.
Required Clearance
These instructions were determined using standard
American cabinets. Standard base cabinets measure 36"
(91.4 cm) high x 24" (61 cm) deep. Cabinets over the
cooking surface and cabinets adjacent to those over the
cooking surface measure 13" (33 cm) deep from backwall.
If nonstandard cabinets are used, care should be taken to
alter dimensions accordingly.
24" (61 cm) is acceptable when the bottom of the wood or
metal cabinet is protected by (a) not less than 1/4" (6.4
mm) of flame-retardant material which must be covered
with (b) not less than No. 28 MSG sheet metal, 0.015" (0.4
mm) stainless steel’ or 0.024" (0.6 mm) aluminum or
copper.
No clearance is required from unit walls to adjacent vertical
combustible walls on rear, right or left.
Clearance from range top to adjacent vertical walls must be
at least 4" (10.2 cm).
Note: Some cabinet finishes cannot survive the
temperatures allowed by safety standards, particularly selfcleaning ovens; the cabinets may discolor or stain. This is
most noticeable with laminated cabinets.
English 8
Avoid obstructing air flow
9 WARNING
Risk of fire - do not obstruct the vent space at the
rear of the range top. Do not caulk or otherwise seal
this opening.
The Duel Fuel range requires a 1/8 inch (3 mm) opening to
be left open at the back of the range cooktop. The Gas
range requires a 1/4 inch (6 mm) opening to be left open at
the back of the range cooktop. This allows proper airflow to
occur. If this opening is sealed, the range and/or
surrounding cabinetry could overheat, possibly creating a
fire hazard.
Prepare Walls and Floor
Seal any holes in the walls or floo. Remove any obstructions (extra electrical or gas connections, etc.) so that
range will rest against wall properly.
Installation Procedure
Installation of the anti-tip
bracket
9 WARNING
A child or adult can tip the range
over and be killed.Verify that the
anti-tip bracket is securely
installed. Ensure the anti-tip
bracket is engaged when the
range is moved.
The range can tip forward potentially causing injury and
damage if the anti-tip bracket is not installed. Do no operate
the range without the anti-tip bracket in place.
Steps to Install the Anti-Tip Bracket
1. Adjust height of range and level by rotating the
adjustable leg supports on the bottom of the range,
using a 1-1/4" wrench.
2. Position the bracket as shown below in the back left
corner of the installation opening, against the back wall
and the left cabinet wall. Mount the bracket using two
screws into either the floor or the base of the adjacent
cabinet. Note The mounting surface must be secure. When mounting to the cabinet wall make sure
the screws engage the frame of the cabinet, not the
thin wall of the cabinet only. Do not use a block or
spacer to fill a gap between the anti-tip bracket and the
cabinet wall.
3. Secure the bracket with two screws to the floor or to
the base of the cabinet wall. Depending on the floor or
cabinet material use wood or anchorless concrete
screws (included). Concrete screws require the use of
a 3/16" masonry bit. Screws should provide fim
attachment into solid wood or flooring. Do not attempt
to anchor into drywall.
Countertop Requirements
Countertops must be smooth and level.
English 9
Electrical Connection
The Dual Fuel slide in range may be connected using a
electric range cord (as specified in the Electrical
Requirements section preceeding) or using a flexible
conduit electrical connection. The Gas slide in range has a
120 volt power cord and plugs into a standard 120 volt wall
outlet.
Gas Ranges
The 120v power cord is installed on gas ranges.
Dual Fuel Ranges - Connect Electric
Range Cord
This section applies only to dual fuel ranges (does not
apply to gas ranges). Dual fuel ranges have a gas cooktop
and an electric oven.
1. Note: In Canada, the range is shipped from the factory
with the range cord already installed. Continue to
“Complete the installation” on page 11.For installations
other than those in Canada, connect the range cord at
the terminal block. Access the terminal block by
removing the cover in the lower left hand corner of the
range back panel.
Install Strain Relief
Place strain relief in knockout below terminal block.
9 WARNING
The strain relief provided with your range cord must
be properly installed.Strain reliefs vary. Carefully
read and follow the instructions included with your
strain relief.
1. In the knockout panel below the terminal block, remove
the knockout that fits our strain relief.
2. Feed range cord through hole and strain relief up to
terminal block. Allow for slack in the cord between the
strain relief and terminal block.
3. Once cord length/slack has been adjusted, attach
strain relief per instructions included with strain relief.
Tip: The knockout panel (below the terminal block) can be
removed from the range to install the strain relief: Remove
panel from range, install strain relief in panel and reattach.
DO NOT remove entire range back panel.
9 WARNING
Risk of Electric Shock or Fire. Frame grounded to
neutral through a ground strap. Grounding through
the neutral conductor is prohibited for new branchcircuit installations (1996 NEC), mobile homes, and
recreational vehicles, or in an area where local
codes prohibit grounding through the neutral
conductor.
For installations where grounding through the neu-tral
conductor is prohibited, (a) disconnect the link from the
neutral, (b) use grounding terminal or lead to ground unit,
(c) connect neutral terminal to lead branch circuit neutral in
usual manner (when the appliance is to be connected by
means of a cord kit, use 4-conductor cord for this purpose.
Use only cord kits rated 125/250 volts (minimum), 30
amperes and labeled “For Use with Ranges”. Strain relief
provided with cord must be installed per instructions
included with cord.
English 10
3-Wire Hookup4-Wire Hookup
is up and align the hole with the grounding hole below
the terminal block. Use the green grounding screw (B)
to attach the green wire (C) on top of grounding strap.
Tighten the grounding screw firmly, but do not
overtighten.
R=Red
W = White
GS = Grounding Strip
B = Black
.
R=Red
W = White
G = Green
B = Black
9 WARNING
To prevent electrical shock, the grounding prong on
the range cord should not be cut or removed under
any circumstances. It must be plugged into a
matching grounding type receptacle and connected
to a correctly polarized 240- Volt circuit. If there is
any doubt as to whether the wall receptacle is
properly grounded, have it checked by a qualified
electrician.
Four wire range cord connection (Recommended
Method)
1. Disconnect electrical power at breaker box. Remove
the terminal block cover to expose the terminal block.
2. Remove the top nut (has an attached locking washer)
from each post.
Note: DO NOT remove the second nut/washer on each
post. These must stay in place to anchor the internal
wiring attached to the terminal block.
5. Attach the red wire to the left junction block terminal
using one of the nut/washer parts removed in step 2.
3. Remove screw from bottom end of ground strap.
4. Remove the green grouning screw from the lower end
of the grounding strap. Remove the upper end of the
grounding strap from the center post of the junction
bar. Rotate the grounding strip (A) so that the wide end
English 11
6. Attach the white wire to the center junction block
terminal using one of the nut/washer parts.
7. Attach the black wire to the right junction block terminal
using one of the nut/washer parts.
8. Tighten all connections securely and replace terminal
block cover.
9. Properly secure strain relief (see previous section)
Note: DO NOT plug in the range at this time.
Three wire range cord connection (Alternate Method)
The Four Wire Connection (above) is preferred, but where
local codes and ordinances permit grounding through the
neutral and where conversion to four wire is impractical, the
unit may be connected to the power supply via a three wire
connection.
1. Disconnect electrical power at breaker box.
2. Remove the terminal block cover to expose the
terminal block.
3. Remove the top nut (has an attached locking washer)
from each terminal post.
Note: DO NOT remove the second nut/washer on each
post. These must stay in place to anchor the internal
wiring attached to the terminal block.
4. Attach the white wire to the center junction block
terminal using one of the nut/washer parts.
5. Attach the red wire to the left junction block terminal
using one of the nut/washer parts removed in step 2.
6. Attach the black wire to the right junction block terminal
using one of the nut/washer parts.
Connect Electric Flexible Conduit
The range can also be connected via flxible conduit. If
using this method, always use the lugs supplied
Note: In Canada, the range is shipped from the factory with
the range cord already installed. Continue to “Complete the
installation” on page 11. For installations other than those in
Canada, connect the flexible conduit at the terminal block.
Four Wire Flexible Conduit Connection
1. Disconnect electrical power at the breaker box.
2. Remove the terminal block cover to expose the
terminal block.
3. Remove the top nut (has an attached locking washer)
from each terminal post.
7. Tighten all connections securely and replace terminal
block cover.
8. Properly secure strain relief (see previous section).
Note: DO NOT plug in range at this time.
Note: DO NOT remove the second nut/washer on each
post. These must stay in place to anchor the internal wiring
attached to the terminal block.
4. Remove the green grounding screw from the lower end
of the grounding strap.
5. Remove the grounding strap from the center post on
the terminal block. The strap will not be needed with
the flexible conduit electric installation. Remove it from
the unit.
6. Attach one terminal lug (packaged with this manual)
using the green grounding screw. Insert the screw
through the lug into the grounding hole below the
terminal block. Tighten the screw firmly, but do not
overtighten.
7. Place one terminal lug (packaged with this manual) on
each terminal block post. Replace the nut/washer on
each post and tighten to 20 in/lbs. (50.8 cm) of torque.
8. Strip 3/8” (9.5 mm) of insulation from the end of the
insulated grounding wire.
English 12
Three Wire Flexible Conduit Connection
The Four Wire Connection is preferred, but where local
codes and ordinances permit grounding through neutral
and/or conversion to four wire is impractcal, unit may be
connected to the power supply via a three wire connection
1. Disconnect electrical power at the breaker box.
2. Remove the terminal block cover to expose the
terminal block.
3. 3. Remove the top nut, star washer, and round washer
from each post.
9. Insert the insulated grounding wire (G) into the lug
below the terminal block.
10. Insert stripped end of white wire (W) into the center lug.
11. Secure the clamping screw.Insert the stripped end of
the red wire (R) into the left lug. Secure clamping
screw.
12. Insert the black wire (B) into the right lug. Secure the
wire in place using the lug clamping screw.
13. Tighten each clamping screw with the appropriate
torque (see table).
GaugeTorque (in/lbs)Torque (Nm)
6353.95
8252.82
14. Properly secure flexible conduit at knockout on angle
and at supply side junction box. The wiring is now
complete.
Note: DO NOT remove last round washer, last nut or internal wire leads.
4. Place one terminal lug (packaged with this manual) on
each post. Replace the star washer and round washer
and secure with 20" (50.8 cm) pounds of torque.
5. Strip 3/8" (9.5 mm) of insulation om the end of each
wire.
6. Insert stripped end of white wire into the center lug on
top of the ground strap. Secure the clam-ping
screw.
Note: DO NOT plug in range at this time.
English 13
7. Insert stripped end of red wire into the left lug. Secure
clamping screw.
8. Insert stripped end of black wire into the right lug.
Secure clamping screw.
9. Tighten each clamping screw with the appropriate
torque (See table below).
GuageTorque (in/lbs)Torque (Nm)
6353.95
8252.82
from the back of the range. To reach the access panel,
remove the warming drawer.
10. Properly secure flxible conduit at knockout pa-nel on
range and at supply side junction box. The wiring is
now complete.
Note: DO NOT plug in range at this time.
Connect Gas Supply
Shut off main gas supply valve before disconnecting the old
range and leave it off until the new hook-up has been
completed. Don’t forget to relight the pilot on other gas
appliances when you turn the gas back on.
Important note for LP users
The range is shipped from the factory for use with natural
gas. For use with propane (LP) gas, your range must first
be converted using the LP conversion kit supplied with your
range. The conversion must be done by a qualified
technician.
Flexible Connector Method
If using rigid pipe, skip to “Rigid Pipe Connector Method”
section following.
Attach Connector
B
C
A
The range can be installed using rigid pipe or a CSA
International-certified flexible metal appliance connector. If
using a flexible connector, always use a new connector.
Apply pipe joint compound or Teflon
use with LP gas and Natural gas around all male pipe
threads to prevent leaks.
The gas connection is located below the back panel of the
range. It is accessible through the drawer access panel or
® tape appropriate for
Item
A
B
C
1. Install male 1/2” flare adaptor at the 1/2” NPT internal
2. Install male 1/2” or 3/4” flare union adapter on the inter-
3. Connect flexible metal appliance connector.
Gas Shut Off Valve
Regulator
Flexible Connector
thread of the range inlet. Use a backup wrench on the
elbow fitting to avoid damage.
nal thread of the manual shutoff valve.
English 14
Rigid Pipe Connector Method
A
B
C
D
E
D
B
F
Gas Flow to Range
B
If using a flexible connector, return to “Flexible Connector
Method” on previous page.
Item
A
Elbow; Connect to regulator here
Test for Gas Leaks
Leak testing is to be conducted by the installer according to
the instructions given in this section.
Note:
Be careful not to apply pressure to warming drawer
element during rigid pipe testing.
1. Turn on gas.
2. Apply a non-corrosive leak detection fluid. Include all
joints and fittings between the shutoff valve and the
range. Include gas fittings and joints in the range if connections may have been disturbed during installation.
3. Inspect for leaks. Bubbles appearing around fittings and connections indicate a leak.
4. If a leak appears, turn off supply line gas shutoff valve
and tighten connections.
5. Retest for leaks. Turn gas back on at supply line shutoff
valve and reapply leak detection fluid.
6. When no bubbles appear, test is complete. Wipe off all
detection fluid residue.
.
9 WARNING
Never check for gas leaks with a flame.
B
C
D
E
F
The configuration of the rigid pipe connection will vary
depending on the location of the gas pipe stub.
Complete Gas Connection
1. Connect pipe to range at union. Access the connection
The gas connection is complete. It is important to test for
gas leaks before proceeding with the remainder of the
installation.
Pipe Nipple
Union
Elbow
Gas Shut Off Valve
1/2” to 3/4” Gas Pipe
through the access panel behind the drawer.
Do not continue to the next step until all leaks are
eliminated.
English 15
Complete the installation
Adjust Leveling Legs
1. Make sure circuit breaker is off and then plug range
cord into electrical outlet.
2. Line up range in front of opening.
3. Measure (A) back left corner of opening from floor to
the top of the countertop.
4. Measure back left corner of range to bottom of cooktop
trim (B). Adjust leveling leg until this height is the same
as the corner dimension.
6. Adjust front leveling legs so that the bottom of the
cooktop trim is ½" (12.7 mm) higher than the
corresponding countertop surface.
Slide Range into Opening
NOTICE
To avoid risk of damage to the range oven door, do
not lift, push or pull the range by holding the door
handle. Open the door and reach inside the top of
the oven cavity to locate a ridged area near the front
of the oven. Take care not to touch the oven heating
element also located at the top of the oven cavity,
just behind the ridged area.
1. Plug in power cord.
2. Dampen countertop and floor at bottom of opening with
soapy water.
3. Slide range into opening, being careful not to damage
countertops, floors, or the range door or warming
drawer front. Do not apply pressure to cooktop when
sliding into position. Be careful not to crimp the flexible
electrical connector.
5. Repeat in right back corner.
Tip: Remove the range warming drawer to prevent
damage.
Check Back of range for proper Installation
1. When properly installed, the cooktop trim around the
back of the range will rest lightly on the countertop.
2. There should not be any gap between the countertop
and the trim; however, the weight of the range must not
rest on the countertop. Look under the range to verify
that both back legs are resting solidly on the floor. Also
verify that the left range leg is retained by the anti-tip
bracket.
English 16
Reinstalling the Oven Door
L
O
W
H
IG
H
_
M
E
D
P
R
O
O
F
+
O
N
/
O
F
F
and Warming Drawer
Reinstall the oven door:
1. Hold the door firmly in
both hands.
2. Hold the door at a 30º
angle from the closed
position and insert
hinges into the slots.
You may need to rock
the door forward and
backward slightly to
seat the hinge feet.
3. The door may need to
be removed and reinserted until the
hinges sit correctly in
the slots.
4. The drawer has a “push-to-open” operation. Pressing
the front of the drawer inward causes the drawer to self
open.
5. Open and close drawer to test operation. Note: if the
drawer will not close, verify that the rail release levers
are properly positioned.
4. Open door all the way
to expose hinges,
levers, and slots.
5. Push levers forward
and down until seated
on the bracket.
6. Close and open door
slowly to be sure it is
correctly and securely
in place. Door must be
straight, not crooked.
Reinstall the Warming Drawer.
1. Be sure cabinet rails are pushed inside cabinet.
2. Align the rails on the drawer rails with the rails attached
to the drawer housing.
3. Firmly push the drawer straight into the drawer housing
until the drawer clicks into place. The drawer should
insert easily. If it binds, do not attempt to force it.
Remove the drawer, align the slides on the housing to
the front edge of the housing and try again. Slide the
drawer into both housing slides at the same time, and
keep the drawer level while doing so.
Testing Operation
Test the Oven
1. Turn on power at the breaker.
2. Test the oven mode.
Select the BAKE mode. See the Use and Care Manual
for detailed operation instructions.
3. Verify that the oven light comes on and the oven begins
to preheat.
4. Test the door lock.
Set the SELF CLEAN mode. Confirm that the door
locks when the lock icon appears in the display.
5. If any of the tests do not result as explained above,
contact Bosch service for assistance. Otherwise,
continue with testing the rangetop burners.
Test the Rangetop Burners
Each burner must be tested for proper lighting, proper
flame characteristics on the low setting and proper flame
characteristics on the high setting.
English 17
Test for proper ignition:
1. Push down and turn the knob to the flame symbol.
2. Verify that the ignitor/spark module clicks.
3. Once the air has been purged from the supply lines,
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LP Gas.
Soft Blue Flames:
Normal for Natural Gas.
verify that the burner lights within four (4) seconds.
After burner lights, turn knob to the off position.
4. Test each rangetop burner in this fashion. Call Service
if any of the burners do not light.
Some yellow streaking is normal during the initial start-up.
Allow unit to operate 4-5 minutes and re-evaluate.
When correct color, carryover and size are verified, the
burner testing is complete.
Test flame characteristics on the low setting:
1. Push in and turn the knob to the flame symbol until the
burner ignites.
2. Turn knob quickly to the low setting.
3. Verify that the flame is:
•A minimum height (approximately 1/4” or 6 mm).
•Steady (The flame should not go out, lift or blow off
of the burner. It should carry over, or surround, the
entire burner.)
•The right color. It should be blue with an inner and
outer cone. See Figure 24: Checking Flame Characteristics for more information.
4. Test each rangetop burner in this fashion. If any flame
goes out, does not carry over properly or is too large,
contact service.
Test flame characteristics on the high setting:
1. Push in and turn the knob to the flame symbol until the
burner ignites.
2. Turn knob to the high setting.
3. Verify that the flame is:
•Steady (The flame should not go out, lift or blow off
of the burner. It should carry over, or surround, the
entire burner.)
•The right color. It should be blue with an inner and
outer cone. See Figure 24: Checking Flame Characteristics for more information.
4. Test each rangetop burner in this fashion. If any flame
burns yellow or does not carry over properly, contact
service.
If any of the tests do not result as explained above, contact
Bosch service for assistance. Otherwise, the installation is
complete at this time.
If the flame is completely or mostly yellow, verify that the
regulator is set for the correct fuel. After adjustment, retest.
English 18
Loading...
+ 47 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.