Bosch BP007-1VTC, BP007-1HZC User Manual

Page 1
i series
Engineering
Model BP Residential Geothermal Heat Pumps
Overview and Certifi cations
Submittal
Sheet
Standard Features, Factory Installed Options, and Field Installed Accessories
Standard Features
Available in Horizontal and Vertical Cabinets
Constructed using white pre-painted steel — Superior corrosion protection for units indoors — Hanging brackets standard for horizontal cabinet
High Efficiency
Up to 21.2 EER @ FL GLHP
Compliant with Energy Start Tier 3 PSC blower motor for 007 - 012 Constant Torque ECM for units sizes 015-060
Configured as Ordered
Left hand or right hand return air — Top, straight through, or end supply air
½" Dual Density Fiber Insulation
non-combustible, non-hydroscopic and does not
support fungal growth
meets NFPA 90A and 90B for fire protection — meets the GREENGUARD Indoor Air Quality Standard
Compressors
Floating compressor base pan for quite operation — 007-018 Rotary — 0024-070 Scroll
1 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Standard MERV 8 Filter with 4 sided Filter Rack
TXV (Thermal Expansion Valve)
Improves refrigerant management and efficiencies
Reliability - Durability - Serviceability
Tin plated coil — UPM circuit board with communicating features — Completely serviceable from front of unit
Electronic Circuit Board UPM
The electronic circuit board provides protection with:
Random Start of Unit — 5 minute short cycle time dely — Alarm communicating Output — Anti-short cycling — Low pressure switch bypass at start up
It also monitors and communicates standard safety features/alerts/operation/protection:
Low Pressure Switch — High Pressure Switch — Evaporator Freeze Switch — Water Coil Freeze Switch — Condenstate Overflow Switch
This circuit board can communicate with a Bosch thermostat that alerts the customer of adverse conditions.
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Londonderry, NH • Ft. Lauderdale, FL
Page 2
i Series Model BP
Residential Geothermal Heat Pumps
Standard Features, Factory Installed Options, and Field Installed Accessories continued..
Engineering Submittal Sheet
Tin Plated Evaporator Coil
Tin electro-plated copper tubing with high-tech polymer
coated aluminum fins will protect the evaporator coil from all forms of corrosive elements in the airstream
Standard 75 VA Transformer
Standard Warranty
10 Year all parts limited warranty — 10 Year labor limited warranty
Factory Installed Options
Heat Recovery Package (HRP)
HRP is a domestic hot water generator feature that can
be connected to a homes hot water system
ECM Constant Torque
The constant-torque blower motor option offers
improved efficiency (up to 33%) over the standard PSC motor
ECM Constant CFM (Variable Speed)
The new high efficiency ECM motor option, available in
1/3hp to 1hp, provides constant airflow in a wide static pressure range up to 1 in.w.g.
Improved efficiency up to 33% over the standard PSC
motor
Hot Gas Reheat
Another option for dehumidification
Fluid Differential Pressure Switch
Prevents the unit refrigerant pressure switches to fault
out
Closed Cell Foam Insulation
Quiet Operation — Improved Indoor Air Quality
Auxiliary Pump Relay
Energy Management Relay Switch (on/off)
Comfort Alert Module
This module can be added for additional diagnostic
features
Field Installed Accessories
Optional 2" MERV 13 Filter
The MERV 13 filter is a cost effective way of
upgrading air quality while maintaining low pressure drop and sustaining long service life
Thermostats:
Bosch thermostats are fully customized to meet your
individual needs
Photo-Catalytic Oxidizers (PCO):
Refreshes and cleans the air in your home by
converting Volatile Organic Compounds and other gases into harmless water vapor and CO2
Humidifiers:
Bosch humidifiers release moisture into the air while
helping to seal windows and doors tightly
Smoke Detection:
In case of a fire, prevents smoke from spreading from
room to room
Fresh Air Dampers:
Helps to prevent home from going into a negative
pressure situation
Electric Duct Heaters
Swivel Water Connections
3/4" or 1" FPT Swivel Water Connection
2 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 3
i Series Model BP
Residential Geothermal Heat Pumps
Model Nomenclature
BP 048- 1 VT C -F L T
SERIES:
BP
NOMINAL CAPACITY: SUPPLY AIR LOCATION
VOLTAGE DESIGNATION:
1 - 208-230/1/60
CABINET CONFIGURATION:
VT - VERTICAL HZ - HORIZONTAL
HEAT EXCHANGER MATERIAL:
C - COPPER N - CUPRO-NICKEL
Engineering Submittal Sheet
VT UNITS:
T - TOP
HZ UNITS:
S - STRAIGHT THRU E - END DISCHARGE
RETURN AIR LOCATION:
L - LEFT R - RIGHT
WATER CONNECTIONS LOCATIONS:
F - FRONT
ASHRAE/AHRI/ISO 13256-1. with PSC Motor
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Models
BP007 6800 15.7 8800 5.7 8400 25.1 7000 4.9 7400 18.5 5100 3.6
BP009 9000 16.2 11200 5.5 10500 25.5 9000 4.5 9500 19.3 6800 3.6
BP012 12200 14.9 16500 5.1 14600 22.7 13000 4.3 13000 17.5 10000 3.6
ASHRAE/AHRI/ISO 13256-1. with ECM Motor (Const Torque or Const Air Flow)
Models
BP015 15200 17.5 17500 5.6 17000 28.8 13000 4.6 16200 20.6 11000 3.9
BP018 19500 16.4 21300 5.3 21300 25.6 17700 4.5 20500 19.0 14800 3.8
BP024 24500 18.2 28500 5.7 28400 28.1 23700 4.6 26000 21.1 18000 4.0
BP030 27000 16.6 31000 5.9 31700 27.0 25000 5.2 28500 19.4 20500 4.3
BP036 36000 17.2 41000 5.6 40200 25.9 34400 4.9 37500 19.7 26000 4.1
BP042 40600 18.2 42400 6.0 45000 25.7 35000 5.1 42200 21.7 26800 4.1
BP048 47400 17.2 50000 5.3 52900 26.1 40500 4.3 49500 20.0 33400 3.7
BP060 60400 16.2 71500 5.7 66500 24.1 56700 4.9 61500 18.5 47000 4.2
Cooling
Capacity
(Btu/hr)
Cooling
Capacity
(Btu/hr)
EER
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
EER
Heating
Capacity
(Btu/hr)
Heating
Capacity
(Btu/hr)
COP
COP
Cooling
Capacity
(Btu/hr)
Cooling
Capacity
(Btu/hr)
EER
EER
Heating
Capacity
(Btu/hr)
Heating
Capacity
(Btu/hr)
COP
COP
Cooling
Capacity
(Btu/hr)
Cooling
Capacity
(Btu/hr)
EER
EER
Heating
Capacity
(Btu/hr)
Heating
Capacity
(Btu/hr)
COP
COP
3 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 4
Engineering Submittal Sheet
i Series Model BP
Residential Geothermal Heat Pumps
Physical Data
Description Unit
Compressor Type
Max Water Working Pressure PSIG/kPa
Standard Fan Motor & Blower
Fan Motor Type/Speeds
Fan Motor (HP) HP 1/10 1/10 1/10 1/3 1/3 1/3
Blower Wheel Size (Dia. x W) Inch
ECM Const CFM Fan Motor
Fan Motor Type/Speeds
Fan Motor (HP) HP
Water Connection Size
FPT Inch
Coaxial Coil Volume gal
Vertical Cabinet
Refrigeration Charge oz
Air Coil Dimensions (H x L) Inch 12x16.5 12x16.5 16x16.5 16.5x20 16.5x20 24x21
Standard Filter - 2" MERV 8 (H x L) Inch 15x20 15x20 18x20 20x20 20x20 24x24
Weight - Operating Lbs 140 154 166 191 195 229
Weight - Shipping Lbs
Horizontal Cabinet
Refrigeration Charge oz
Air Coil Dimensions (H x L) Inch 12x16.5 12x16.5 16x16.5 18x18.5 18x18.5 18x28
Standard Filter - 2" MERV 8 (H x L) Inch 15x20 15x20 18x20 18x20 18x20 20x30
Weight - Operating Lbs 165 172 173 190 198 307
Weight - Shipping Lbs
BP007 BP009 BP012 BP015 BP018 BP024
Rotary Rotary Rotary Rotary Rotary Scroll
400/3100 400/3100 400/3100 400/3100 400/3100 400/3100
PSC/3 PSC/3 PSC/3
4.5x4.5 4.5x4.5 5.5x5.5 5.5x4.5 9x7 9x7
NA NA NA
3/4 3/4 3/4 3/4 3/4 3/4
0.15 0.15 0.31 0.31 0.31 0.48
29 31 46 35 35 65
160 174 186 208 212 242
29 31 40 35 35 65
185 192 205 218 222 340
Value
ECM Const
Torque / 3
speed
ECM Const
CFM / 3
speed
1/3 1/3 1/3
ECM Const
Torque / 3
speed
ECM Const
CFM / 3
speed
ECM Const
Torque / 3
speed
ECM Const
CFM / 3
speed
4 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 5
Engineering Submittal Sheet
i Series Model BP
Residential Geothermal Heat Pumps
Physical Data
Description Unit
Compressor Type
Max Water Working Pressure PSIG/kPa
Standard Fan Motor & Blower
Fan Motor Type/Speeds
Fan Motor (HP) HP 1/2 3/4 3/4 3/4 1
Blower Wheel Size (Dia. x W) Inch
ECM Const CFM Fan Motor
Fan Motor Type/Speeds
Fan Motor (HP) HP
Water Connection Size
FPT Inch
Coaxial Coil Volume gal
Vertical Cabinet
Refrigeration Charge oz
Air Coil Dimensions (H x L) Inch 24x27 24x27 32x27 32x27 40x27
Standard Filter - 2" MERV 8 (H x L) Inch 24x30 24x30 16x30 (2) 16x30 (2) 20x30 (2)
Weight - Operating Lbs 269 281 334 340 396
Weight - Shipping Lbs
Horizontal Cabinet
Refrigeration Charge oz
Air Coil Dimensions (H x L) Inch 20x32.5 20x32.5 20x43.25 20x43.25 20x54
Standard Filter - 2" MERV 8 (H x L) Inch 20x34.5 20x34.5 20x24 (2) 20x24 (2) 20x28 (2)
Weight - Operating Lbs 358 369 400 405 452
Weight - Shipping Lbs
BP030 BP036 BP042 BP048 BP060
Scroll Scroll Scroll Scroll Scroll
400/3100 400/3100 400/3100 400/3100 400/3100
ECM Const
Torque / 3
speed
9x7 9x7 10x8 10x8 11x9
ECM Const
CFM / 3 speed
1/2 3/4 3/4 3/4 1
1 1 1 1 1
0.39 0.62 0.62 0.62 0.62
71 71 80 82 90
292 304 360 366 422
71 65 80 82 90
404 415 465 470 520
ECM Const
Torque / 3
speed
ECM Const
CFM / 3 speed
Value
ECM Const
Torque / 3
speed
ECM Const
CFM / 3 speed
ECM Const
Torque / 3
speed
ECM Const
CFM / 3 speed
ECM Const
Torque / 3
speed
ECM Const
CFM / 3 speed
5 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 6
Engineering Submittal Sheet
i Series Model BP
Residential Geothermal Heat Pumps
Horizontal Cabinet Corner Weights
Confi guration Left Hand Evaporator Right Hand Evaporator
Model Unit Total Left Front* Right Front* Left Back Right Back Left Front* Right Front* Left Back Right Back
BPH 007
BPH 009
BPH 012
BPH 015
BPH 018
BPH 024
BPH 030
BPH 036
BPH 042
BPH 048
BPH 060
Lbs
kg 75 18 19 19 19 18 19 18 20
Lbs 172 42 44 44 42 41 45 41 45
kg 78 19 20 20 19 19 20 19 20
Lbs 173 46 42 45 40 44 44 40 45
kg 79 21 19 21 18 20 20 18 21
Lbs 190 45 45 53 47 46 44 47 53
kg 86 20 20 25 21 21 20 21 24
Lbs 198 51 49 50 48 49 51 47 51
kg 90 23 22 23 22 22 23 22 23
Lbs 307 80 78 79 70 77 81 68 81
kg 140 36 36 36 32 35 37 31 37
Lbs 358 99 88 92 79 96 92 78 92
kg 163 45 40 42 36 44 42 35 42
Lbs 369 100 92 94 83 96 96 81 96
kg 168 45 42 43 38 44 44 36 44
Lbs 400 107 99 105 89 103 103 88 106
kg 182 49 45 48 40 47 47 40 48
Lbs 405 106 108 102 89 102 112 85 106
kg 184 48 49 46 41 46 51 39 48
Lbs 452 116 118 118 100 111 123 95 123
kg
165 40 42 42 41 39 43 39 44
205 53 54 54 44 50 56 43 56
*Front is control box end
6 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 7
Engineering Submittal Sheet
i Series Model BP
Residential Geothermal Heat Pumps
Factory Installed Options and Applicable Models
Description Applicable Model Numbers
Variable Speed/Constant CFM Blower Motor BP015 to BP060
Heat Recovery Package/DeSuperheater/Hot Water Generator BP024 to BP060
Electric Heat - 3.6/4.8 kW BP018 to BP060
Electric Heat - 7.8/9.6 kW BP024 to BP060
Electric Heat - 10.8/14.4 kW BP036 to BP060
Electric Heat - 14.4/19.2 kW BP048 to BP060
Sound Package BP024 to BP060
Hot Gas Reheat (HGRH) BP024 to BP060
Differential Pressure Switch All Models
Pump Relay All Models
Factory Installed Option - Cupro-Nickel Coil
Model Number with Standard Copper Coil
BP007-1HZC BP007-1HZN
BP007-1VTC BP007-1VTN
BP009-1HZC BP009-1HZN
BP009-1VTC BP009-1VTN
BP012-1HZC BP012-1HZN
BP012-1VTC BP012-1VTN
BP015-1HZC BP015-1HZN
BP015-1VTC BP015-1VTN
BP018-1HZC BP018-1HZN
BP018-1VTC BP018-1VTN
BP024-1HZC BP024-1HZN
BP024-1VTC BP024-1VTN
BP036-1HZC BP036-1HZN
BP036-1VTC BP036-1VTN
BP048-1HZC BP048-1HZN
BP048-1VTC BP048-1VTN
BP060-1HZC BP060-1HZN
BP060-1VTC BP060-1VTN
(To add this option to the product, change the model number 10TH Digit to an “N”)
Model Number with Cupro-Nickel Coil
7 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 8
Engineering Submittal Sheet
i Series Model BP
Residential Geothermal Heat Pumps
Electrical Data - Standard Motor - PSC for 007-012, Constant Torque for 015-070
Model
BP007 -1 208-230/1/60 1 2.5 17.7 1 0.96 0.1 4.1 15
BP009 -1 208-230/1/60 1 3.4 22.2 1 0.96 0.1 5.2 15
BP012 -1 208-230/1/60 1 4.6 27.9 1 0.96 0.1 6.7 15
BP015 -1 208-230/1/60 1 5.6 29 1 2.8 0.33 9.8 15
BP018 -1 208-230/1/60 1 7.4 33 1 2.8 0.33 12.1 15
BP024 -1 208-230/1/60 1 13.5 58.3 1 2.8 0.33 19.7 30
BP030 -1 208-230/1/60 1 12.8 58.3 1 4.1 0.5 20.1 30
BP036 -1 208-230/1/60 1 16 77 1 6 0.75 26.0 40
BP042 -1 208-230/1/60 1 16.7 79 1 6 0.75 26.9 40
BP048 -1 208-230/1/60 1 19.9 109 1 6 0.75 30.9 50
BP060 -1 208-230/1/60 1 25 134 1 7.6 1 38.9 60
Electrical
Symbol
Voltage/Phase/Hz
Compressor Blower Motor
QTY RLA LRA QTY FLA HP
Min Circuit
Amps
Max Fuse/
HACR
Electrical Data - Constant CFM Motor
Model
BP015 -1 208-230/1/60 1 5.6 29 1 2.8 0.33 9.8 15
BP018 -1 208-230/1/60 1 7.4 33 1 2.8 0.33 12.1 15
BP024 -1 208-230/1/60 1 13.5 58.3 1 2.8 0.33 19.7 30
BP030 -1 208-230/1/60 1 12.8 58.3 1 4.3 0.5 20.3 30
BP036 -1 208-230/1/60 1 16 77 1 6.8 0.75 26.8 40
BP042 -1 208-230/1/60 1 16.7 79 1 6.8 0.75 27.7 40
BP048 -1 208-230/1/60 1 19.9 109 1 6.8 0.75 31.7 50
BP060 -1 208-230/1/60 1 25 134 1 9.1 1 40.4 60
Electrical
Symbol
Voltage/Phase/Hz
Compressor Blower Motor
QTY RLA LRA QTY FLA HP
Min Circuit
Amps
208/230V Units shipped with transformer wired for
230V—for 208V remove orange tranformer primary lead and replace with red lead.
Max Fuse/
HACR
8 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 9
Engineering Submittal Sheet
i Series Model BP
Residential Geothermal Heat Pumps
Electrical Data - Electric Heat Option Compressor Power Connection
(A)
Compressor
Fuses 240V 208V 240V 208V
F1/F2
F3/F4
F1/F2
F3/F4
F1/F2
F3/F4
F1/F2
F3/F4
F1/F2
F3/F4
F1/F2
F3/F4
82.5 72.4 90 80
82.5 72.4 90 80
82.5 72.4 90 80
107.5 94.0 110 100
84.5 74.4 90 80
109.5 96.0 110 100
Min Circuit
Amps
Models Voltage Code Voltage/Phase/Hz
BP015 1 208-230/1/60 197/253 1 7.4 33.0 9.3 15
BP018 1 208-230/1/60 197/253 1 13.5 58.3 16.9 30
BP024 1 208-230/1/60 197/253 1 12.8 58.3 26.5 25
BP030 1 208-230/1/60 197/253 1 16.0 77.0 20.0 30
BP036 1 208-230/1/60 197/253 1 16.7 79.0 20.9 30
BP042 1 208-230/1/60 197/253 1 19.9 109.0 24.9 40
BP048 1 208-230/1/60 197/253 1 25.0 134.0 31.3 50
BP060 -1 208-230/1/60 197/253 1 26.3 134.0 26.5 50
Electrical Data - Electric Heat Option Constant Torque ECM
Model
BP018 4.8 1 4,800 3,600 20.0 17.3 2.8 - 28.5 25.1 30 30
BP024 4.8 1 4,800 3,600 20.0 17.3 2.8 - 28.5 25.1 30 30
BP024 9.6 1 9,600 7,200 40.0 34.6 2.8 - 53.5 46.8 60 50
BP030 4.8 1 4,800 3,600 20.0 17.3 4.1 - 30.1 26.8 35 30
BP030 9.6 1 9,600 7,200 40.0 34.6 4.1 - 55.1 48.4 60 50
BP036 4.8 1 4,800 3,600 20.0 17.3 6.0 - 32.5 29.1 35 30
BP036 9.6 1 9,600 7,200 40.0 34.6 6.0 - 57.5 50.8 60 60
BP036 14.4 2 14,400 10,800 60 51.9 6
BP042 4.8 1 4,800 3,600 20.0 17.3 6.0 - 32.5 29.1 35 30
BP042 9.6 1 9,600 7,200 40.0 34.6 6.0 - 57.5 50.8 60 60
BP042 14.4 2 14400 10800 60 51.9 6
BP048 4.8 1 4,800 3,600 20.0 17.3 6.0 - 32.5 29.1 35 30
BP048 9.6 1 9,600 7,200 40.0 34.6 6.0 - 57.5 50.8 60 60
BP048 14.4 2 14400 10800 60 51.9 6
BP048 19.2 2 19200 14000 80 69.2 6
BP060 4.8 1 4,800 3,600 20.0 17.3 7.6 - 34.5 31.1 35 35
BP060 9.6 1 9,600 7,200 40.0 34.6 7.6 - 59.5 52.8 60 60
BP060 14.4 2 14400 10800 60 51.9 7.6
BP060 19.2 2 19200 14000 80 69.2 7.6
EH RATED
kW
STAGE
Heater Watts Heater AMPS Circuit MCA MOP
240 208 240V 208V
Voltage Min/
Max
QTY RLA LRA
Motor FLA
Max Fuse/
HACR
9 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 10
Engineering Submittal Sheet
i Series Model BP
Residential Geothermal Heat Pumps
Electrical Data - Electric Heat Option Constant Airfl ow ECM
Model
BP018 4.8 1 4,800 3,600 20.0 17.3 2.8 - 28.5 25.1 30 30
BP024 4.8 1 4,800 3,600 20.0 17.3 2.8 - 28.5 25.1 30 30
BP024 9.6 1 9,600 7,200 40.0 34.6 2.8 - 53.5 46.8 60 50
BP030 4.8 1 4,800 3,600 20.0 17.3 4.3 - 30.4 27.0 35 30
BP030 9.6 1 9,600 7,200 40.0 34.6 4.3 - 55.4 48.6 60 50
BP036 4.8 1 4,800 3,600 20.0 17.3 6.8 - 33.5 30.1 35 35
BP036 9.6 1 9,600 7,200 40.0 34.6 6.8 - 58.5 51.8 60 60
BP036 14.4 2 14400 10800 60 51.9 6.8
BP042 4.8 1 4,800 3,600 20.0 17.3 6.8 - 33.5 30.1 35 35
BP042 9.6 1 9,600 7,200 40.0 34.6 6.8 - 58.5 51.8 60 60
BP042 14.4 2 14400 10800 60 51.9 6.8
BP048 4.8 1 4,800 3,600 20.0 17.3 6.8 - 33.5 30.1 35 35
BP048 9.6 1 9,600 7,200 40.0 34.6 6.8 - 58.5 51.8 60 60
BP048 14.4 2 14400 10800 60 51.9 6.8
BP048 19.2 2 19200 14000 80 69.2 6.8
BP060 4.8 1 4,800 3,600 20.0 17.3 9.1 - 36.4 33.0 40 35
BP060 9.6 1 9,600 7,200 40.0 34.6 9.1 - 61.4 54.6 70 60
BP060 14.4 2 14400 10800 60 51.9 9.1
BP060 19.2 2 19200 14000 80 69.2 9.1
EH RATED
kW
STAGE
Heater Watts Heater AMPS Circuit MCA MOP
240 208 240V 208V
Motor FLA
(A)
Fuses 240V 208V 240V 208V
F1/F2
F3/F4
F1/F2
F3/F4
F1/F2
F3/F4
F1/F2
F3/F4
F1/F2
F3/F4
F1/F2
F3/F4
83.5 73.4 90 80
83.5 73.4 90 80
83.5 73.4 90 80
108.5 95.0 110 100
86.4 76.3 90 80
111.4 97.9 120 100
10 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 11
Engineering Submittal Sheet
i Series Model BP
Residential Geothermal Heat Pumps
Operating Limits - Cooling & Heating
Description Standard Unit
COOLING
Minimum ambient air temperature °F 50
Maximum ambient air temperature °F 100*
Minimum evaporator entering air db/wb °F 68/57
Rated air coil entering air db/wb °F 80/67
Maximum evaporator entering air db/wb °F 95/85
Minimum water coil entering fl uid temperature °F 40*
Water loop typical coil entering fl uid range temperature °F 70/90
Maximum water coil entering fl uid temperature °F 110
HEATING
Minimum ambient air temperature °F 40
Maximum ambient air temperature °F 85
Minimum evaporator entering air db °F 50
Rated air coil entering air °F 68
Maximum evaporator entering air db °F 80
Normal water coil entering fl uid range °F 25-80*
Minimum water coil entering Fluid °F 20*
* Antifreeze solution is required for fl uid temperature at or below 45 Degrees F.
11 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 12
Engineering Submittal Sheet
i Series Model BP
Residential Geothermal Heat Pumps
Blower Performance CFM Standard Motor - PSC for 007-012, Constant Torque ECM for 015-070
Available External Static Pressure (in. wc. Wet coil and fi lter included)
Model
BP007
BP009
BP012
BP015 Medium 530 510 480 445 405 360 ------
BP018
BP024
BP030
BP036
BP042
BP048
BP060
Motor
Speed
Low430420390360335310260-----
Medium 420 390 365 335 310 270 ------
High 370 360 340 315 285 245 ------
Low430420390360335310260-----
Medium 420 390 365 335 310 270 ------
High 370 360 340 315 285 245 ------
Low450435415400385360330305----
Medium 425 405 385 375 360 335 310 -----
High 390 380 365 350 335 315 290 -----
Low710685650610575545460370----
High 430 410 370 335 290 245 ------
Low730700660615580545505460----
Medium 615 575 540 500 460 420 ------
High 540 510 480 445 405 360 ------
Low975945910880855825790750----
Medium 905 885 855 825 790 755 700 650 ----
High 725 700 670 640 585 530 ------
Low 1225 1195 1170 1140 1110 1075 1010 940 745 - - -
Medium 1110 1075 1045 1015 985 955 915 880 700 - - -
High 955 925 890 860 825 790 750 715 685 - - -
Low 1440 1420 1400 1380 1345 1315 1240 1165 1005 845 - -
Medium 1340 1315 1290 1270 1245 1225 1180 1135 990 845 - -
High 1190 1165 1140 1115 1090 1065 1040 1020 915 810 - -
Low 1645 1635 1610 1585 1560 1535 1510 1485 1460 1430 - -
Medium 1455 1425 1400 1375 1345 1320 1290 1260 1225 1190 - -
High 1220 1190 1160 1130 1100 1070 1015 955 895 830 - -
Low 1840 1820 1795 1775 1745 1720 1695 1670 1645 1615 - -
Medium 1655 1635 1610 1585 1560 1535 1510 1485 1460 1430 - -
High 1455 1425 1400 1375 1345 1320 1290 1260 1225 1190 - -
Low 2225 2195 2165 2135 2105 2075 2045 2015 1980 1945 1900 1850
Medium 2070 2045 2015 1990 1960 1925 1895 1870 1840 1810 1685 1600
High 1815 1785 1755 1725 1695 1665 1630 1595 1555 1515 1425 -
0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20
12 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 13
Engineering Submittal Sheet
i Series Model BP
Residential Geothermal Heat Pumps
Blower Performance CFM (Variable Speed Constant CFM ECM)
Available External Static Pressure (in. wc. Wet coil and fi lter included)
Model
BP015
BP018
BP024
BP030 + 1150 1150 1150 1150 1150 1150 1150 1150 1150 - - -
BP036
BP042
BP048
BP060
Motor
Speed
+575575575575575575575575----
Normal500500500500500500500500----
-425425425425425425425425----
+745745745745745745745745----
Normal650650650650650650650650----
-555555555555555555555555----
+ 1095 1095 1095 1095 1095 1095 1095 1095 1095 - - -
Normal 950 950 950 950 950 950 950 950 950 - - -
- 810 810 810 810 810 810 810 810 810 - - -
Normal 1000 1000 1000 1000 1000 1000 1000 1000 1000 - - -
- 850 850 850 850 850 850 850 850 850 - - -
+ 1380 1380 1380 1380 1380 1380 1380 1380 1380 1380 - -
Normal 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 - -
- 1020 1020 1020 1020 1020 1020 1020 1020 1020 1020 - -
+ 1610 1610 1610 1610 1610 1610 1610 1610 1610 1610 - -
Normal 1400 1400 1400 1400 1400 1400 1400 1400 1400 1400 - -
- 1190 1190 1190 1190 1190 1190 1190 1190 1190 1190 - -
+ 1840 1840 1840 1840 1840 1840 1840 1840 1840 1840 - -
Normal 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600 - -
- 1360 1360 1360 1360 1360 1360 1360 1360 1360 1360 - -
+ 2300 2300 2300 2300 2300 2300 2300 2300 2300 2300 2300 2300
Normal 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000
- 1700 1700 1700 1700 1700 1700 1700 1700 1700 1700 1700 -
0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20
13 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 14
i Series Model BP
Residential Geothermal Heat Pumps
Vertical Unit Confi guration
Engineering Submittal Sheet
Access Panel
Water Out
Condensate Drain
Water In
FRONT–FRT
Right Hand Return
Top Discharge FRT
Horizontal Unit Confi guration
ont Fr
High Voltage
Access Panel
Electrical Knockouts 4 Places
Low Voltage
Straight Through FRS
End FRE
Left Hand Return
Top Discharge FLT
Straight Through FLS
End FLE
Access Panel
Water Out
Condensate Drain
Water In
FRONT–FLT
Access Panel
High Voltage
Electrical Knockouts 4 Places
Low Voltage
ont Fr
Return Air Right
14 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Return Air Left
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 15
i Series Model BP
Residential Geothermal Heat Pumps
BP-Vertical Dimensions and Connections
Engineering Submittal Sheet
E
F
G
C
B
D
Access
Panel
Condenser
Water Out
Condensate
Drain
Condenser
K
J
A
Water In
Electrical
Knock-outs
A
E
D
F
Q
M
P
C
N
B
H
Left Hand Return (FLT) Right Hand Return (FRT) Return Air (Filter) View
BP-Vertical Dimensions and Connections
ABCDEFGHJKMNPQ
Model
BP007 21.75 21.75 32.75 11.75 7.75 5.00 8.50 2.25 8.00 13.75 18.00 13.00 15.00 8.50 3/4" FPT 15 x 20 x 1
BP009 21.75 21.75 32.75 11.75 7.75 5.00 8.50 2.25 8.00 13.75 18.00 13.00 15.00 8.50 3/4" FPT 15 x 20 x 1
BP012 21.75 21.75 32.75 11.75 7.75 5.00 8.50 2.62 7.50 12.50 18.00 16.00 18.00 8.50 3/4" FPT 18 x 20 x 1
BP015 21.75 21.75 39.25 13.75 13.75 4.00 6.12 2.25 7.50 12.25 18.00 18.00 20.00 4.00 3/4" FPT 20 x 20 x 1
BP018 21.75 21.75 39.25 13.75 13.75 4.00 6.12 2.25 7.50 12.25 18.00 18.00 20.00 4.00 3/4" FPT 20 x 20 x 1
BP024 21.75 26.25 47.25 13.75 15.75 6.25 4.87 2.50 8.75 15.00 22.00 22.00 24.00 4.00 3/4" FPT 24 x 24 x 1
BP030 24.25 33.50 47.25 15.75 15.75 8.87 7.00 2.50 8.50 14.50 28.00 22.00 24.00 4.00 1" FPT 24 x 30 x 1
BP036 24.25 33.50 47.25 15.75 15.75 8.87 7.00 2.50 8.50 14.50 28.00 22.00 24.00 4.00 1" FPT 24 x 30 x 1
BP042 26.25 33.50 58.25 17.75 17.75 7.87 6.75 3.25 8.50 13.25 28.00 30.00 32.00 4.00 1" FPT 16 x 30 x 1 (2)
BP048 26.25 33.50 58.25 17.75 17.75 7.87 6.75 3.25 8.50 13.25 28.00 30.00 32.00 4.00 1" FPT 16 x 30 x 1 (2)
BP060 26.25 33.50 66.25 17.75 17.75 7.87 7.00 3.25 8.50 13.25 28.00 38.00 40.00 4.00 1" FPT 20 x 30 x 1 (2)
Width DBPth Height
Dis­charge DBPth
Dis-
charge
Width
Cabinet Edge to
Dis-
charge
Left
Side to
Dis-
charge
Water In
Bottom to Con-
densate
Drain
Water
Out
R/A
Duct
Width
R/A
Duct Flange Height
Filter
Rack
Height
Right
Side to
Dis-
charge
Condenser
Water
Connections
Recommended
Replacement Normal Filter
Size
All dimensions within +/– 0.125". Specifi cations
subject to change without notice.
15 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 16
i Series Model BP
Residential Geothermal Heat Pumps
BP-Horizontal Dimensions and Connections
Engineering Submittal Sheet
D
E
Access
CC
Panel
F
H
Electrical
Knock-outs
B
Return Air
Opening
M
K
J
N
Condensate
Drain
Q
K
N
B
AA
Return Air
Opening
P
Condensate
Drain
G
Left Hand Return Left Hand Return Left Hand Return
End Blow (FLE) Straight Through (FLS)
Condenser
Water In
Condenser
Water Out
Access
Panel
Return Air
D
Opening
E
F
Condensate
Drain
Q
K
N
J
BB
AA
C
Condensate
Drain
Return Air
Opening
M
K
P
N
C
Right Hand Return Right Hand Return Right Hand Return End Blow (FRE) Straight Through (FRS)
BP- Horizontal Dimensions and Connections
ABCDEFGHJKMNPQRT
Model
Width Depth Height
BP007 21.75 43.25 16.75 0.50 20.25 22.25 2.25 13.87 3.50 11.75 4.62 7.75 3.50 4.62 15.00 13.00 3/4" FPT 15 x 20 x 1
BP009 21.75 43.25 16.75 0.50 20.25 22.25 2.25 13.87 3.50 11.75 4.62 7.75 3.50 4.62 15.00 13.00 3/4" FPT 15 x 20 x 1
BP012 22.25 45.25 19.75 0.62 20.25 24.25 2.50 12.50 3.62 11.75 7.12 7.75 3.62 4.75 18.00 16.00 3/4" FPT 18 x 20 x 1
BP015 22.25 45.25 19.75 1.62 20.25 23.25 2.50 12.50 2.75 13.75 3.12 13.75 2.75 2.87 18.00 16.00 3/4" FPT 18 x 20 x 1
BP018 22.25 45.25 19.75 1.62 20.25 23.25 2.50 12.50 2.75 13.75 3.12 13.75 2.75 2.87 18.00 16.00 3/4" FPT 18 x 20 x 1
BP024 26.25 54.75 22.00* 1.25 30.25 23.00 2.62 15.12 3.75 13.75 2.12 15.75 3.75 4.25 20.12 18.00 3/4" FPT 20 x 30 x 1
BP030 30.25 68.25 22.00* 2.00 35.00 31.25 2.50 13.25 4.50 15.75 4.00 15.75 4.50 2.25 20.12 18.00 1" FPT 20 x 34.5 x 1
BP036 30.25 68.25 22.00* 2.00 35.00 31.25 2.50 13.25 4.50 15.75 4.00 15.75 4.50 2.25 20.12 18.00 1" FPT 20 x 34.5 x 1
BP042 30.25 79.00 22.00* 0.75 48.25 29.62 2.75 13.25 4.50 17.75 2.25 17.75 4.50 2.12 20.12 18.00 1" FPT 20 x 24 x 1 (2)
BP048 30.25 79.00 22.00* 0.75 48.25 29.62 2.75 13.25 4.50 17.75 2.25 17.75 4.50 2.12 20.12 18.00 1" FPT 20 x 24 x 1 (2)
BP060 30.25 89.25 22.00* 1.87 56.25 31.00 2.62 13.25 4.50 17.75 2.25 17.75 4.50 2.12 20.12 18.00 1" FPT 20 x 28 x 1 (2)
Cab
End to
Filter Rack
"R/A Duct
Width"
Cab
Front
to Filter
Rack
Water InWater
Out
Side to
Dis-
charge
Dis-
charge
Width
Top to
Dis­charge (FLE &
FRS)
Dis­charge Height
End to
Dis-
charge
Top to
Dis-
charge
(FRE &
FLS)
Filter Rack
Height
R/A
Duct Flange Height
Condenser
Water
Connections
Recommended
Replacement
Normal Filter
Size
All dimensions within +/– 0.125". Specifi cations
subject to change without notice.
16 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 17
i Series Model BP
Residential Geothermal Heat Pumps
BP Service Clearances
Engineering Submittal Sheet
Vertical Unit
Service Clearances
A
Blower
I
R
C O
I
L
Compressor
Electrical
Control
Box
Blower Access 18" Minimum 24" Op timum
Compressor Access and Electrical/Control Access 24" Minimum 36" Optimum
Front of Unit
NOTE: The local electric codes may require 36" or more clearance at the electrical control box.
Horizontal Unit
Service Clearances
AIR COIL
Blower Access 18" Minimum 24" Op timum
Blower
NOTE: The local electric codes may require 36" or more clearance at the electrical control box.
17 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Electrical
Control
Compressor
Box
Compressor Access and Control Access 24" Minimum 36" Optimum
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 18
i Series Model BP
Residential Geothermal Heat Pumps
BP007 (315 CFM) Capacity Data
Entering
Fluid
Temp (F)
50
60
70
80
85
90
100
110
Water
Pressure
Flow
Drop
(GPM)
(FOH)
1 1.5 0.6
2 5.2 2.3
3 10.8 4.7
1 1.4 0.6
2 5 2.2
3 10.4 4.5
1 1.4 0.6
2 4.9 2.1
3 10.1 4.4
1 1.3 0.6
2 4.7 2.0
3 9.7 4.2
1 1.3 0.6
2 4.6 2.0
3 9.6 4.2
1 1.3 0.6
2 4.6 2.0
3 9.4 4.1
1 1.3 0.6
2 4.4 1.9
3 9.2 4.0
1 1.2 0.5
2 4.3 1.9
3 8.9 3.9
Pressure
Drop (PSI)
COOLING HEATING
Entering Air Temp
(db/wb) F
75/63 7.8 6.8 8.8 0.34 23.0 80/67 8.3 7.1 9.3 0.33 25.0 70 5.0 3.6 0.46 3.2 85/71 8.8 7.3 9.9 0.32 27.1 80 4.8 3.3 0.49 2.9 75/63 8.0 7.0 9.0 0.31 26.1 80/67 8.6 7.2 9.6 0.30 29.0 70 5.2 3.9 0.46 3.3 85/71 9.2 7.4 10.1 0.28 32.4 80 5.0 3.6 0.50 3.0 75/63 8.1 7.0 9.1 0.30 26.9 80/67 8.7 7.2 9.6 0.29 30.0 70 5.3 3.9 0.46 3.4 85/71 9.3 7.5 10.2 0.27 34.3 80 5.1 3.6 0.50 3.0 75/63 7.4 6.7 8.5 0.38 19.2 80/67 7.8 6.9 9.0 0.38 20.5 70 5.8 4.4 0.47 3.7 85/71 8.4 7.2 9.5 0.37 22.5 80 5.6 4.1 0.50 3.3 75/63 7.6 6.7 8.7 0.36 21.2 80/67 8.1 7.0 9.2 0.34 23.4 70 6.1 4.7 0.47 3.8 85/71 8.7 7.3 9.8 0.34 25.9 80 5.9 4.4 0.51 3.4 75/63 7.7 6.8 8.7 0.35 22.0 80/67 8.2 7.0 9.3 0.34 24.1 70 6.3 4.8 0.47 4.0 85/71 8.8 7.3 9.8 0.33 26.6 80 6.0 4.5 0.51 3.5 75/63 6.9 6.5 8.2 0.43 15.9 80/67 7.4 6.7 8.7 0.43 17.2 70 6.6 5.2 0.47 4.1 85/71 7.9 7.0 9.2 0.42 18.6 80 6.4 4.8 0.51 3.7 75/63 7.1 6.6 8.4 0.41 17.4 80/67 7.7 6.8 8.9 0.40 19.2 70 7.1 5.6 0.47 4.4 85/71 8.2 7.0 9.4 0.39 20.8 80 6.8 5.2 0.52 3.9 75/63 7.2 6.6 8.4 0.40 18.1 80/67 7.7 6.9 8.9 0.39 19.7 70 7.2 5.8 0.47 4.5 85/71 8.3 7.1 9.5 0.38 21.7 80 6.9 5.3 0.52 3.9 75/63 6.5 6.3 7.9 0.48 13.5 80/67 7.0 6.6 8.3 0.48 14.6 70 7.5 6.1 0.48 4.6 85/71 7.4 6.9 8.8 0.47 15.6 80 7.3 5.7 0.52 4.1 75/63 6.7 6.4 8.0 0.45 14.7 80/67 7.2 6.7 8.5 0.45 15.9 70 8.0 6.6 0.48 4.9 85/71 7.7 7.0 9.0 0.44 17.4 80 7.7 6.1 0.52 4.3 75/63 6.8 6.4 8.1 0.45 15.2 80/67 7.3 6.7 8.6 0.44 16.5 70 8.2 6.7 0.48 5.1 85/71 7.8 7.0 9.1 0.43 17.9 80 7.9 6.3 0.52 4.4 75/63 6.3 6.2 7.7 0.50 12.5 80/67 6.7 6.5 8.2 0.50 13.3 70 8.4 6.9 0.48 5.2 85/71 7.2 6.8 8.6 0.50 14.4 80 8.1 6.5 0.52 4.6 75/63 6.5 6.3 7.9 0.48 13.5 80/67 6.9 6.6 8.3 0.48 14.4 70 9.0 7.5 0.48 5.5 85/71 7.4 6.9 8.8 0.47 15.6 80 8.7 7.0 0.53 4.9 75/63 6.6 6.3 7.9 0.47 14.0 80/67 7.0 6.6 8.4 0.47 14.9 70 9.2 7.8 0.48 5.7 85/71 7.5 6.9 8.9 0.46 16.2 80 8.9 7.2 0.53 5.0 75/63 6.1 6.1 7.6 0.53 11.5 80/67 6.5 6.4 8.0 0.53 12.3 70 9.3 7.9 0.48 5.7 85/71 6.9 6.7 8.5 0.52 13.1 80 9.0 7.4 0.53 5.0 75/63 6.3 6.2 7.7 0.50 12.4 80/67 6.7 6.5 8.2 0.50 13.3 70 10.0 8.6 0.48 6.2 85/71 7.2 6.8 8.6 0.50 14.4 80 9.6 8.0 0.53 5.3 75/63 6.4 6.3 7.8 0.50 12.9 80/67 6.8 6.5 8.2 0.49 13.7 70 10.3 8.8 0.48 6.4 85/71 7.3 6.8 8.7 0.49 14.9 80 9.8 8.2 0.53 5.4 75/63 5.7 5.7 7.3 0.58 9.8 80/67 6.1 6.1 7.7 0.58 10.5 85/71 6.5 6.5 8.2 0.58 11.2 75/63 5.9 5.9 7.4 0.55 10.6 80/67 6.3 6.3 7.9 0.55 11.3 85/71 6.7 6.6 8.3 0.55 12.1 75/63 5.9 5.9 7.5 0.55 10.7 80/67 6.4 6.4 7.9 0.54 11.7 85/71 6.8 6.7 8.3 0.54 12.5 75/63 5.3 5.3 7.0 0.63 8.4 80/67 5.7 5.7 7.4 0.63 9.0 85/71 6.0 6.0 7.8 0.63 9.5 75/63 5.5 5.5 7.1 0.61 9.0 80/67 5.8 5.8 7.5 0.61 9.5 85/71 6.2 6.2 7.9 0.61 10.2 75/63 5.5 5.5 7.2 0.60 9.1 80/67 5.9 5.9 7.6 0.60 9.8 85/71 6.3 6.3 8.0 0.60 10.5
Total
Capacity
(MBTUH)
Sensible Capacity (MBTUH)
Heat of Rejection (MBTUH)
Power
Input (kW)
EER
Entering
Temp (F)
Water
Fluid
30*
40*
50
60
70
80
* Extended Range - Antifreeze required for entering fl uid
temperture at or below 45 Degrees F.
AHRI/ISO13256-1 certified per formance is rated at entering air conditions
of 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Tabulated unit performance does not include fan or pump power
corrections required for AHRI/ISO standard performance ratings.
Unit performance may be interpolated. Extrapolation is not allowed.
Ratings below 40°F are with a methanol solution.
Due to variations in installation, actual performance may vary from the
tabulated data. Performance contained herein are as a result of extensive testing by FHP and are not express warranties between the parties and may be changed at any time.
Continuous research and development to improve our products may result
in a change to the current design and specifications without notice.
Pressure
Flow
(GPM)
Drop
(FOH)
1 1.6 0.7
2 5.6 2.4
3 11.6 5.0
1 1.6 0.7
2 5.4 2.3
3 11.2 4.9
1 1.5 0.6
2 5.2 2.3
3 10.8 4.7
1 1.4 0.6
2 5.0 2.2
3 10.5 4.5
1 1.4 0.6
2 4.9 2.1
3 10.1 4.4
1 1.4 0.6
2 4.7 2.0
3 9.8 4.2
Engineering Submittal Sheet
Pressure
Drop (PSI)
Entering
Air Temp
Total
Capacity
(F)
(MBTUH)
60 5.1 3.9 0.43 3.5
60 5.4 4.2 0.43 3.7
60 5.5 4.3 0.43 3.8
60 6.0 4.7 0.43 4.1
60 6.4 5.1 0.43 4.4
60 6.5 5.2 0.43 4.4
60 6.9 5.6 0.43 4.7
60 7.3 6.0 0.43 5.0
60 7.5 6.2 0.43 5.1
60 7.8 6.5 0.43 5.3
60 8.3 7.0 0.43 5.7
60 8.5 7.2 0.43 5.8
60 8.7 7.4 0.43 5.9
60 9.3 8.1 0.43 6.4
60 9.6 8.3 0.43 6.6
60 9.6 8.3 0.43 6.6
60 10.4 9.1 0.42 7.2
60 10.7 9.4 0.42 7.5
Heat of
Absorption
(MBTUH)
Power
Input
(kW)
COP
18 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 19
i Series Model BP
Residential Geothermal Heat Pumps
BP009 (325 CFM) Capacity Data
Entering
Fluid
Temp (F)
50
60
70
80
85
90
100
110
Water
Pressure
Flow
Drop
(GPM)
(FOH)
1 1.2 0.5
2 4.1 1.8
3 8.6 3.7
1 1.1 0.5
2 4 1.7
3 8.3 3.6
1 1.1 0.5
2 3.9 1.7
3 8 3.5
1 1.1 0.5
2 3.7 1.6
3 7.8 3.4
1 1.1 0.5
2 3.7 1.6
3 7.6 3.3
1 1 0.4
2 3.6 1.6
3 7.5 3.2
1 1 0.4
2 3.5 1.5
3 7.3 3.2
1 1 0.4
2 3.4 1.5
3 7.1 3.1
Pressure
Drop (PSI)
COOLING HEATING
Entering Air Temp
(db/wb) F
75/63 9.8 7.8 11.1 0.42 23.2 80/67 10.4 8.0 11.7 0.41 25.0 70 6.4 4.6 0.59 3.2 85/71 11.1 8.3 12.4 0.41 27.2 80 6.3 4.3 0.64 2.9 75/63 10.3 8.0 11.4 0.36 28.4 80/67 11.0 8.2 12.1 0.35 31.5 70 6.9 5.0 0.60 3.4 85/71 11.7 8.5 12.8 0.33 35.0 80 6.7 4.7 0.65 3.1 75/63 10.4 8.0 11.5 0.34 30.3 80/67 11.1 8.3 12.2 0.33 34.0 70 7.0 5.2 0.60 3.4 85/71 11.9 8.5 12.9 0.31 38.4 80 6.8 4.8 0.65 3.1 75/63 9.3 7.6 10.8 0.48 19.2 80/67 9.9 7.8 11.4 0.48 20.6 70 7.4 5.6 0.61 3.6 85/71 10.6 8.1 12.0 0.47 22.3 80 7.3 5.2 0.66 3.3 75/63 9.8 7.8 11.1 0.43 22.9 80/67 10.4 8.0 11.7 0.42 25.0 70 8.0 6.1 0.61 3.8 85/71 11.1 8.3 12.4 0.40 27.5 80 7.7 5.7 0.67 3.4 75/63 9.9 7.8 11.2 0.41 24.2 80/67 10.6 8.1 11.8 0.40 26.8 70 8.2 6.3 0.62 3.9 85/71 11.3 8.3 12.5 0.38 29.7 80 7.9 5.8 0.67 3.5 75/63 8.8 7.4 10.5 0.55 16.0 80/67 9.4 7.6 11.1 0.54 17.2 70 8.5 6.5 0.62 4.0 85/71 10.0 7.9 11.7 0.54 18.4 80 8.3 6.1 0.68 3.6 75/63 9.2 7.6 10.7 0.49 18.6 80/67 9.9 7.8 11.4 0.48 20.4 70 9.1 7.2 0.63 4.3 85/71 10.5 8.0 12.0 0.47 22.1 80 8.9 6.7 0.69 3.8 75/63 9.4 7.6 10.8 0.48 19.7 80/67 10.0 7.9 11.5 0.46 21.5 70 9.4 7.4 0.63 4.4 85/71 10.7 8.1 12.1 0.45 23.6 80 9.1 6.9 0.69 3.9 75/63 8.3 7.2 10.1 0.61 13.5 80/67 8.9 7.4 10.7 0.61 14.5 70 9.5 7.5 0.63 4.4 85/71 9.4 7.7 11.3 0.61 15.4 80 9.3 7.1 0.69 3.9 75/63 8.7 7.3 10.4 0.56 15.5 80/67 9.3 7.6 11.0 0.55 16.8 70 10.3 8.3 0.64 4.7 85/71 10.0 7.9 11.6 0.55 18.3 80 10.0 7.8 0.71 4.2 75/63 8.8 7.4 10.5 0.54 16.1 80/67 9.5 7.7 11.1 0.54 17.7 70 10.6 8.6 0.65 4.8 85/71 10.1 7.9 11.7 0.53 19.1 80 10.3 8.1 0.71 4.3 75/63 8.1 7.1 10.0 0.64 12.5 80/67 8.6 7.3 10.5 0.64 13.3 70 10.6 8.6 0.64 4.8 85/71 9.2 7.6 11.1 0.64 14.2 80 10.4 8.1 0.71 4.3 75/63 8.5 7.2 10.2 0.59 14.3 80/67 9.1 7.5 10.8 0.59 15.4 70 11.6 9.5 0.65 5.3 85/71 9.7 7.8 11.4 0.58 16.6 80 11.2 8.9 0.72 4.6 75/63 8.6 7.3 10.3 0.58 14.8 80/67 9.2 7.5 10.9 0.57 16.1 70 11.9 9.9 0.65 5.4 85/71 9.8 7.8 11.5 0.56 17.4 80 11.6 9.3 0.72 4.7 75/63 7.8 7.0 9.8 0.68 11.5 80/67 8.3 7.2 10.4 0.68 12.2 70 11.7 9.7 0.65 5.3 85/71 8.9 7.5 10.9 0.68 13.1 80 11.5 9.1 0.72 4.7 75/63 8.2 7.1 10.0 0.63 13.0 80/67 8.8 7.4 10.6 0.62 14.1 70 12.8 10.8 0.65 5.8 85/71 9.4 7.6 11.2 0.62 15.1 80 12.5 10.1 0.73 5.1 75/63 8.3 7.2 10.1 0.61 13.5 80/67 8.9 7.4 10.7 0.61 14.6 70 13.2 11.2 0.65 5.9 85/71 9.5 7.7 11.3 0.60 15.8 80 12.8 10.5 0.73 5.2 75/63 7.3 6.8 9.4 0.74 9.8 80/67 7.8 7.0 10.0 0.75 10.4 85/71 8.3 7.3 10.5 0.75 11.1 75/63 7.7 6.9 9.7 0.70 11.0 80/67 8.2 7.2 10.3 0.70 11.7 85/71 8.8 7.4 10.8 0.69 12.7 75/63 7.7 6.9 9.8 0.68 11.2 80/67 8.3 7.2 10.3 0.68 12.1 85/71 8.9 7.5 10.9 0.68 13.1 75/63 6.8 6.6 9.1 0.81 8.4 80/67 7.2 6.8 9.6 0.81 8.8 85/71 7.7 7.1 10.1 0.82 9.4 75/63 7.1 6.7 9.3 0.77 9.2 80/67 7.6 7.0 9.9 0.77 9.8 85/71 8.1 7.2 10.4 0.77 10.5 75/63 7.2 6.7 9.4 0.76 9.5 80/67 7.7 7.0 9.9 0.76 10.1 85/71 8.3 7.3 10.5 0.75 11.0
Total
Capacity
(MBTUH)
Sensible Capacity (MBTUH)
Heat of Rejection (MBTUH)
Power
Input (kW)
EER
Entering
Temp (F)
Water
Fluid
30*
40*
50
60
70
80
* Extended Range - Antifreeze required for entering fl uid
temperture at or below 45 Degrees F.
AHRI/ISO13256-1 certified per formance is rated at entering air conditions
of 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Tabulated unit performance does not include fan or pump power
corrections required for AHRI/ISO standard performance ratings.
Unit performance may be interpolated. Extrapolation is not allowed.
Ratings below 40°F are with a methanol solution.
Due to variations in installation, actual performance may vary from the
tabulated data. Performance contained herein are as a result of extensive testing by FHP and are not express warranties between the parties and may be changed at any time.
Continuous research and development to improve our products may result
in a change to the current design and specifications without notice.
Pressure
Flow
(GPM)
Drop
(FOH)
1 1.3 0.5
2 4.4 1.9
3 9.1 3.9
1 1.2 0.5
2 4.2 1.8
3 8.8 3.8
1 1.2 0.5
2 4.1 1.8
3 8.5 3.7
1 1.1 0.5
2 4.0 1.7
3 8.2 3.6
1 1.1 0.5
2 3.8 1.7
3 7.9 3.4
1 1.1 0.5
2 3.7 1.6
3 7.7 3.3
Engineering Submittal Sheet
Pressure
Drop (PSI)
Entering
Air Temp
Total
Capacity
(F)
(MBTUH)
60 6.6 4.9 0.54 3.6
60 7.0 5.4 0.55 3.8
60 7.2 5.5 0.55 3.9
60 7.6 5.9 0.55 4.0
60 8.2 6.5 0.56 4.3
60 8.4 6.7 0.56 4.4
60 8.7 6.9 0.56 4.5
60 9.4 7.6 0.57 4.9
60 9.7 7.9 0.57 5.0
60 9.8 8.0 0.57 5.0
60 10.6 8.8 0.58 5.4
60 11.0 9.2 0.58 5.6
60 10.9 9.1 0.58 5.5
60 11.9 10.1 0.58 6.0
60 12.3 10.5 0.58 6.2
60 12.0 10.2 0.58 6.1
60 13.2 11.4 0.58 6.7
60 13.6 11.9 0.58 6.9
Heat of
Absorption
(MBTUH)
Power
Input
(kW)
COP
19 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 20
i Series Model BP
Residential Geothermal Heat Pumps
BP012 (400 CFM) Capacity Data
Entering
Fluid
Temp (F)
50
60
70
80
85
90
100
110
Water
Pressure
Flow
Drop
(GPM)
(FOH)
1.5 1.1 0.5
2.5 2.7 1.2
3.5 4.9 2.1
1.5 1 0.4
2.5 2.6 1.1
3.5 4.7 2.0
1.5 1 0.4
2.5 2.5 1.1
3.5 4.5 1.9
1.5 1 0.4
2.5 2.4 1.0
3.5 4.4 1.9
1.5 0.9 0.4
2.5 2.4 1.0
3.5 4.3 1.9
1.5 0.9 0.4
2.5 2.3 1.0
3.5 4.3 1.9
1.5 0.9 0.4
2.5 2.3 1.0
3.5 4.1 1.8
1.5 0.9 0.4
2.5 2.2 1.0
3.5 4 1.7
Pressure
Drop (PSI)
COOLING HEATING
Entering Air Temp
(db/wb) F
75/63 13.2 10.0 15.1 0.60 21.8 80/67 14.1 10.3 16.0 0.60 23.5 70 8.9 6.3 0.83 3.2 85/71 15.0 10.5 16.9 0.60 25.1 80 8.7 5.9 0.88 2.9 75/63 13.7 10.2 15.4 0.54 25.1 80/67 14.7 10.5 16.4 0.53 27.5 70 9.4 6.8 0.83 3.3 85/71 15.6 10.8 17.3 0.52 29.7 80 9.2 6.3 0.89 3.0 75/63 13.9 10.3 15.6 0.52 26.7 80/67 14.9 10.6 16.5 0.51 29.4 70 9.6 7.0 0.84 3.4 85/71 15.9 10.9 17.5 0.49 32.2 80 9.4 6.5 0.90 3.1 75/63 12.6 9.7 14.7 0.68 18.5 80/67 13.4 10.0 15.5 0.68 19.7 70 10.2 7.5 0.85 3.5 85/71 14.3 10.3 16.4 0.68 21.1 80 10.0 7.1 0.91 3.2 75/63 13.0 9.9 15.0 0.62 20.8 80/67 13.9 10.2 15.9 0.62 22.5 70 10.9 8.1 0.86 3.7 85/71 14.9 10.5 16.8 0.61 24.4 80 10.6 7.6 0.93 3.4 75/63 13.3 10.0 15.1 0.60 22.2 80/67 14.2 10.3 16.0 0.59 24.1 70 11.2 8.4 0.87 3.8 85/71 15.2 10.6 17.0 0.58 26.2 80 10.9 7.9 0.93 3.4 75/63 11.9 9.4 14.2 0.76 15.7 80/67 12.7 9.7 15.0 0.76 16.7 70 11.7 8.9 0.87 3.9 85/71 13.5 10.0 15.9 0.76 17.7 80 11.4 8.3 0.95 3.5 75/63 12.3 9.6 14.5 0.70 17.4 80/67 13.2 9.9 15.4 0.70 18.8 70 12.4 9.6 0.89 4.1 85/71 14.1 10.2 16.3 0.69 20.3 80 12.1 9.0 0.96 3.7 75/63 12.5 9.7 14.7 0.68 18.3 80/67 13.4 10.0 15.6 0.67 19.9 70 12.8 9.9 0.89 4.2 85/71 14.3 10.3 16.5 0.67 21.4 80 12.5 9.3 0.97 3.8 75/63 11.2 9.1 13.8 0.84 13.4 80/67 12.0 9.5 14.6 0.84 14.2 70 13.2 10.2 0.90 4.3 85/71 12.8 9.7 15.4 0.84 15.1 80 12.9 9.7 0.98 3.9 75/63 11.7 9.3 14.1 0.79 14.9 80/67 12.5 9.6 14.9 0.78 15.9 70 14.1 11.1 0.91 4.5 85/71 13.3 9.9 15.8 0.78 17.0 80 13.7 10.5 0.99 4.0 75/63 11.8 9.4 14.2 0.76 15.4 80/67 12.7 9.7 15.0 0.76 16.7 70 14.5 11.6 0.92 4.6 85/71 13.6 10.0 15.9 0.76 18.0 80 14.1 10.9 1.00 4.1 75/63 10.9 9.0 13.6 0.88 12.4 80/67 11.6 9.3 14.3 0.88 13.1 70 14.7 11.7 0.92 4.7 85/71 12.4 9.6 15.1 0.89 14.0 80 14.4 11.1 1.01 4.2 75/63 11.3 9.2 13.8 0.83 13.6 80/67 12.1 9.5 14.6 0.83 14.6 70 15.8 12.8 0.94 4.9 85/71 12.9 9.8 15.5 0.83 15.6 80 15.4 12.1 1.03 4.4 75/63 11.5 9.2 14.0 0.81 14.2 80/67 12.3 9.6 14.8 0.80 15.2 70 16.3 13.3 0.95 5.1 85/71 13.1 9.9 15.6 0.80 16.3 80 15.9 12.5 1.04 4.5 75/63 10.5 8.9 13.3 0.92 11.4 80/67 11.2 9.2 14.1 0.92 12.1 70 16.3 13.3 0.95 5.1 85/71 12.0 9.5 14.9 0.93 12.9 80 16.0 12.6 1.04 4.5 75/63 10.9 9.0 13.6 0.87 12.5 80/67 11.7 9.3 14.4 0.87 13.4 70 17.5 14.5 0.97 5.3 85/71 12.5 9.7 15.2 0.87 14.3 80 17.1 13.7 1.06 4.7 75/63 11.1 9.1 13.7 0.85 13.0 80/67 11.9 9.4 14.5 0.85 14.0 70 18.2 15.1 0.98 5.5 85/71 12.7 9.7 15.4 0.85 14.9 80 17.7 14.2 1.07 4.9 75/63 9.8 8.6 12.8 1.00 9.8 80/67 10.5 8.9 13.6 1.01 10.4 85/71 11.2 9.2 14.4 1.02 11.0 75/63 10.2 8.7 13.1 0.95 10.7 80/67 10.9 9.1 13.9 0.96 11.3 85/71 11.7 9.4 14.7 0.96 12.1 75/63 10.4 8.8 13.2 0.94 11.1 80/67 11.1 9.2 14.0 0.94 11.8 85/71 11.9 9.5 14.8 0.94 12.6 75/63 9.1 8.3 12.4 1.08 8.4 80/67 9.8 8.7 13.1 1.09 8.9 85/71 10.4 9.0 13.8 1.11 9.4 75/63 9.5 8.5 12.6 1.04 9.1 80/67 10.2 8.8 13.4 1.05 9.7 85/71 10.9 9.1 14.1 1.06 10.3 75/63 9.6 8.5 12.7 1.03 9.3 80/67 10.3 8.9 13.5 1.03 10.0 85/71 11.1 9.2 14.3 1.04 10.7
Total
Capacity
(MBTUH)
Sensible Capacity (MBTUH)
Heat of Rejection (MBTUH)
Power
Input (kW)
EER
Entering
Temp (F)
Water
Fluid
30*
40*
50
60
70
80
* Extended Range - Antifreeze required for entering fl uid
temperture at or below 45 Degrees F.
AHRI/ISO13256-1 certified per formance is rated at entering air conditions
of 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Tabulated unit performance does not include fan or pump power
corrections required for AHRI/ISO standard performance ratings.
Unit performance may be interpolated. Extrapolation is not allowed.
Ratings below 40°F are with a methanol solution.
Due to variations in installation, actual performance may vary from the
tabulated data. Performance contained herein are as a result of extensive testing by FHP and are not express warranties between the parties and may be changed at any time.
Continuous research and development to improve our products may result
in a change to the current design and specifications without notice.
Pressure
Flow
(GPM)
Drop
(FOH)
1.5 1.1 0.5
2.5 2.8 1.2
3.5 5.1 2.2
1.5 1.1 0.5
2.5 2.7 1.2
3.5 5.0 2.1
1.5 1.0 0.5
2.5 2.6 1.1
3.5 4.8 2.1
1.5 1.0 0.4
2.5 2.5 1.1
3.5 4.6 2.0
1.5 1.0 0.4
2.5 2.4 1.1
3.5 4.5 1.9
1.5 0.9 0.4
2.5 2.4 1.0
3.5 4.3 1.9
Engineering Submittal Sheet
Pressure
Drop (PSI)
Entering
Air Temp
Total
Capacity
(F)
(MBTUH)
60 9.1 6.6 0.77 3.5
60 9.6 7.2 0.77 3.7
60 9.9 7.4 0.78 3.7
60 10.4 8.0 0.78 3.9
60 11.1 8.6 0.79 4.1
60 11.5 8.9 0.80 4.2
60 11.9 9.3 0.80 4.4
60 12.7 10.1 0.81 4.6
60 13.1 10.5 0.82 4.7
60 13.4 10.8 0.82 4.8
60 14.4 11.8 0.83 5.1
60 14.9 12.2 0.84 5.2
60 15.0 12.3 0.84 5.3
60 16.2 13.5 0.85 5.6
60 16.7 14.1 0.86 5.7
60 16.7 13.9 0.86 5.7
60 18.0 15.3 0.87 6.1
60 18.7 15.9 0.88 6.2
Heat of
Absorption
(MBTUH)
Power
Input
(kW)
COP
20 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 21
i Series Model BP
Residential Geothermal Heat Pumps
BP015 (500 CFM) Capacity Data
Entering
Fluid
Temp (F)
50
60
70
80
85
90
100
110
Water
Pressure
Flow
Drop
(GPM)
(FOH)
2 1.7 0.7
3 3.5 1.5
4 5.9 2.6
2 1.6 0.7
3 3.4 1.5
4 5.7 2.5
2 1.6 0.7
3 3.3 1.4
4 5.5 2.4
2 1.5 0.6
3 3.2 1.4
4 5.4 2.3
2 1.5 0.6
3 3.1 1.3
4 5.3 2.3
2 1.5 0.6
3 3.1 1.3
4 5.2 2.3
2 1.4 0.6
3 3 1.3
4 5 2.2
2 1.4 0.6
3 2.9 1.3
4 4.9 2.1
Pressure
Drop (PSI)
COOLING HEATING
Entering Air Temp
(db/wb) F
75/63 16.0 12.5 17.9 0.60 26.5 80/67 17.0 12.9 18.9 0.59 28.6 70 9.7 7.0 0.85 3.4 85/71 18.1 13.3 20.0 0.58 31.1 80 9.5 6.5 0.92 3.0 75/63 16.4 12.7 18.2 0.55 29.9 80/67 17.5 13.1 19.2 0.53 32.9 70 10.1 7.3 0.86 3.5 85/71 18.7 13.5 20.3 0.51 36.3 80 9.9 6.8 0.93 3.1 75/63 16.6 12.8 18.3 0.52 31.9 80/67 17.8 13.2 19.4 0.50 35.5 70 10.3 7.5 0.86 3.5 85/71 18.9 13.6 20.5 0.48 39.4 80 10.0 6.9 0.94 3.1 75/63 15.2 12.2 17.4 0.70 21.7 80/67 16.2 12.6 18.4 0.69 23.3 70 11.2 8.3 0.87 3.8 85/71 17.2 13.0 19.4 0.69 25.1 80 10.9 7.8 0.96 3.4 75/63 15.6 12.4 17.7 0.65 24.1 80/67 16.7 12.7 18.7 0.64 26.2 70 11.7 8.7 0.88 3.9 85/71 17.8 13.1 19.8 0.62 28.6 80 11.3 8.2 0.97 3.4 75/63 15.8 12.4 17.8 0.62 25.4 80/67 16.9 12.8 18.9 0.61 27.9 70 11.9 9.0 0.88 4.0 85/71 18.0 13.2 19.9 0.59 30.6 80 11.5 8.4 0.97 3.5 75/63 14.4 11.8 16.9 0.80 18.0 80/67 15.4 12.3 17.9 0.80 19.3 70 12.7 9.8 0.90 4.2 85/71 16.4 12.6 18.9 0.79 20.7 80 12.4 9.2 0.99 3.7 75/63 14.8 12.0 17.2 0.75 19.7 80/67 15.8 12.4 18.2 0.74 21.3 70 13.3 10.3 0.90 4.3 85/71 16.9 12.8 19.2 0.73 23.1 80 12.9 9.6 1.00 3.8 75/63 15.0 12.1 17.3 0.72 20.7 80/67 16.1 12.5 18.3 0.71 22.6 70 13.6 10.6 0.91 4.4 85/71 17.1 12.9 19.4 0.70 24.4 80 13.2 9.9 1.00 3.9 75/63 13.6 11.5 16.4 0.90 15.1 80/67 14.5 11.9 17.3 0.90 16.1 70 14.3 11.4 0.91 4.6 85/71 15.5 12.3 18.3 0.90 17.2 80 14.0 10.7 1.01 4.1 75/63 14.0 11.7 16.6 0.85 16.4 80/67 14.9 12.1 17.6 0.85 17.5 70 15.0 12.0 0.92 4.8 85/71 16.0 12.5 18.6 0.84 19.0 80 14.6 11.2 1.02 4.2 75/63 14.2 11.8 16.8 0.83 17.1 80/67 15.2 12.2 17.7 0.82 18.5 70 15.4 12.4 0.92 4.9 85/71 16.2 12.6 18.8 0.81 19.9 80 14.9 11.6 1.03 4.3 75/63 13.2 11.4 16.1 0.95 13.8 80/67 14.1 11.7 17.1 0.95 14.8 70 16.0 13.0 0.93 5.1 85/71 15.0 12.2 18.0 0.95 15.7 80 15.6 12.2 1.03 4.4 75/63 13.6 11.5 16.4 0.91 15.0 80/67 14.5 11.9 17.3 0.90 16.0 70 16.8 13.8 0.94 5.3 85/71 15.5 12.3 18.3 0.90 17.2 80 16.3 12.9 1.04 4.6 75/63 13.7 11.6 16.5 0.88 15.5 80/67 14.7 12.0 17.5 0.88 16.7 70 17.2 14.2 0.94 5.4 85/71 15.7 12.4 18.5 0.87 18.0 80 16.7 13.3 1.05 4.7 75/63 12.8 11.2 15.9 1.00 12.7 80/67 13.7 11.6 16.8 1.01 13.6 70 17.8 14.7 0.94 5.6 85/71 14.6 12.0 17.7 1.01 14.5 80 17.3 13.8 1.05 4.8 75/63 13.1 11.3 16.1 0.96 13.6 80/67 14.1 11.7 17.1 0.96 14.7 70 18.7 15.6 0.94 5.9 85/71 15.0 12.2 18.0 0.95 15.7 80 18.1 14.7 1.05 5.0 75/63 13.3 11.4 16.2 0.94 14.2 80/67 14.3 11.8 17.2 0.93 15.3 70 19.2 16.2 0.94 6.0 85/71 15.3 12.2 18.2 0.93 16.5 80 18.6 15.1 1.06 5.2 75/63 11.9 10.9 15.3 1.11 10.7 80/67 12.8 11.3 16.2 1.11 11.5 85/71 13.7 11.7 17.1 1.12 12.2 75/63 12.3 11.0 15.6 1.07 11.5 80/67 13.2 11.4 16.5 1.07 12.3 85/71 14.1 11.8 17.4 1.07 13.2 75/63 12.4 11.1 15.7 1.05 11.8 80/67 13.4 11.5 16.6 1.05 12.8 85/71 14.3 11.9 17.5 1.04 13.7 75/63 11.1 10.5 14.8 1.22 9.1 80/67 11.9 10.9 15.7 1.23 9.7 85/71 12.7 11.4 16.5 1.23 10.3 75/63 11.4 10.6 15.0 1.18 9.7 80/67 12.2 11.1 15.9 1.18 10.3 85/71 13.1 11.5 16.8 1.19 11.0 75/63 11.6 10.7 15.1 1.16 10.0 80/67 12.4 11.2 16.0 1.16 10.6 85/71 13.3 11.6 16.9 1.16 11.4
Total
Capacity
(MBTUH)
Sensible Capacity (MBTUH)
Heat of Rejection (MBTUH)
Power
Input (kW)
EER
Entering
Temp (F)
Water
Fluid
30*
40*
50
60
70
80
* Extended Range - Antifreeze required for entering fl uid
temperture at or below 45 Degrees F.
AHRI/ISO13256-1 certified per formance is rated at entering air conditions
of 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Tabulated unit performance does not include fan or pump power
corrections required for AHRI/ISO standard performance ratings.
Unit performance may be interpolated. Extrapolation is not allowed.
Ratings below 40°F are with a methanol solution.
Due to variations in installation, actual performance may vary from the
tabulated data. Performance contained herein are as a result of extensive testing by FHP and are not express warranties between the parties and may be changed at any time.
Continuous research and development to improve our products may result
in a change to the current design and specifications without notice.
Pressure
Flow
(GPM)
Drop
(FOH)
2 1.8 0.8
3 3.8 1.7
4 6.4 2.8
2 1.8 0.8
3 3.7 1.6
4 6.2 2.7
2 1.7 0.7
3 3.6 1.5
4 6.0 2.6
2 1.7 0.7
3 3.4 1.5
4 5.8 2.5
2 1.6 0.7
3 3.3 1.4
4 5.6 2.4
2 1.6 0.7
3 3.2 1.4
4 5.4 2.3
Engineering Submittal Sheet
Pressure
Drop (PSI)
Entering
Air Temp
Total
Capacity
(F)
(MBTUH)
60 9.9 7.4 0.77 3.8
60 10.3 7.8 0.78 3.9
60 10.5 8.0 0.78 3.9
60 11.4 8.9 0.79 4.2
60 11.9 9.4 0.80 4.4
60 12.2 9.6 0.80 4.5
60 13.0 10.4 0.81 4.7
60 13.7 11.0 0.81 5.0
60 14.0 11.4 0.81 5.1
60 14.7 12.1 0.82 5.3
60 15.4 12.8 0.82 5.5
60 15.8 13.2 0.82 5.6
60 16.4 13.8 0.83 5.8
60 17.3 14.6 0.83 6.1
60 17.8 15.1 0.83 6.3
60 18.2 15.6 0.83 6.4
60 19.2 16.6 0.83 6.8
60 19.8 17.1 0.83 7.0
Heat of
Absorption
(MBTUH)
Power
Input
(kW)
COP
21 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 22
i Series Model BP
Residential Geothermal Heat Pumps
BP018 (575 CFM) Capacity Data
Entering
Fluid
Temp (F)
50
60
70
80
85
90
100
110
Water
Pressure
Flow
Drop
(GPM)
(FOH)
2.5 3.2 1.4
4 7.4 3.2
5 11.1 4.8
2.5 3.1 1.3
4 7.2 3.1
5 10.7 4.6
2.5 3 1.3
4 7 3.0
5 10.4 4.5
2.5 2.9 1.3
4 6.7 2.9
5 10.1 4.4
2.5 2.8 1.2
4 6.6 2.9
5 9.9 4.3
2.5 2.8 1.2
4 6.5 2.8
5 9.8 4.2
2.5 2.7 1.2
4 6.3 2.7
5 9.5 4.1
2.5 2.6 1.1
4 6.1 2.6
5 9.2 4.0
Pressure
Drop (PSI)
COOLING HEATING
Entering Air Temp
(db/wb) F
75/63 20.2 15.2 23.3 0.95 21.2 80/67 21.5 15.6 24.6 0.93 23.1 70 13.0 9.4 1.08 3.5 85/71 22.8 15.9 25.8 0.90 25.3 80 12.7 8.8 1.16 3.2 75/63 20.8 15.4 23.9 0.95 21.8 80/67 22.2 15.8 25.2 0.92 24.0 70 13.6 9.9 1.11 3.6 85/71 23.5 16.2 26.5 0.89 26.4 80 13.2 9.3 1.18 3.3 75/63 21.0 15.5 24.1 0.96 21.9 80/67 22.4 15.9 25.4 0.93 24.2 70 13.9 10.1 1.12 3.7 85/71 23.8 16.2 26.7 0.89 26.8 80 13.4 9.5 1.19 3.3 75/63 19.4 14.8 22.5 0.98 19.7 80/67 20.6 15.2 23.7 0.97 21.3 70 14.9 11.0 1.15 3.8 85/71 21.9 15.6 24.9 0.95 23.0 80 14.5 10.4 1.23 3.5 75/63 19.9 15.0 23.0 0.96 20.7 80/67 21.2 15.4 24.3 0.94 22.6 70 15.6 11.7 1.17 3.9 85/71 22.6 15.8 25.5 0.91 24.8 80 15.2 11.0 1.25 3.6 75/63 20.1 15.1 23.2 0.96 21.0 80/67 21.4 15.5 24.5 0.93 23.0 70 15.9 11.9 1.17 4.0 85/71 22.8 15.9 25.7 0.90 25.2 80 15.4 11.2 1.26 3.6 75/63 18.5 14.4 21.8 1.04 17.7 80/67 19.7 14.8 23.0 1.04 19.0 70 16.8 12.8 1.20 4.1 85/71 20.9 15.2 24.2 1.03 20.3 80 16.5 12.1 1.29 3.8 75/63 19.0 14.6 22.2 1.01 18.9 80/67 20.3 15.0 23.4 0.99 20.5 70 17.7 13.6 1.21 4.3 85/71 21.5 15.4 24.7 0.98 22.0 80 17.3 12.8 1.31 3.9 75/63 19.2 14.7 22.3 0.99 19.3 80/67 20.5 15.1 23.6 0.98 21.0 70 18.0 13.9 1.22 4.3 85/71 21.7 15.5 24.8 0.96 22.6 80 17.5 13.1 1.31 3.9 75/63 17.6 14.0 21.2 1.13 15.5 80/67 18.7 14.4 22.3 1.14 16.5 70 18.9 14.7 1.23 4.5 85/71 19.9 14.8 23.5 1.14 17.5 80 18.4 14.0 1.33 4.0 75/63 18.1 14.2 21.5 1.08 16.7 80/67 19.2 14.7 22.7 1.08 17.8 70 19.9 15.7 1.24 4.7 85/71 20.5 15.0 23.9 1.07 19.1 80 19.4 14.8 1.35 4.2 75/63 18.2 14.3 21.6 1.07 17.0 80/67 19.4 14.7 22.8 1.06 18.3 70 20.3 16.1 1.24 4.8 85/71 20.7 15.1 24.1 1.05 19.7 80 19.8 15.1 1.36 4.3 75/63 17.1 13.8 20.9 1.19 14.4 80/67 18.2 14.2 22.0 1.19 15.3 70 21.0 16.8 1.25 4.9 85/71 19.3 14.6 23.1 1.20 16.1 80 20.5 16.0 1.37 4.4 75/63 17.6 14.0 21.2 1.13 15.5 80/67 18.7 14.5 22.3 1.13 16.5 70 22.1 17.9 1.26 5.1 85/71 19.9 14.8 23.5 1.13 17.6 80 21.6 17.0 1.39 4.6 75/63 17.8 14.1 21.3 1.12 15.9 80/67 18.9 14.5 22.4 1.11 17.0 70 22.6 18.4 1.27 5.2 85/71 20.1 14.9 23.7 1.11 18.2 80 22.0 17.3 1.39 4.6 75/63 16.7 13.6 20.6 1.24 13.4 80/67 17.7 14.1 21.7 1.25 14.1 70 23.2 18.9 1.28 5.3 85/71 18.8 14.5 22.8 1.26 14.9 80 22.7 18.0 1.41 4.7 75/63 17.1 13.8 20.9 1.19 14.4 80/67 18.2 14.2 22.0 1.19 15.3 70 24.5 20.2 1.29 5.6 85/71 19.4 14.7 23.2 1.19 16.3 80 23.9 19.1 1.44 4.9 75/63 17.3 13.9 21.0 1.17 14.8 80/67 18.4 14.3 22.1 1.17 15.7 70 25.0 20.7 1.30 5.6 85/71 19.6 14.8 23.3 1.17 16.8 80 24.4 19.5 1.45 4.9 75/63 15.7 13.3 20.0 1.37 11.5 80/67 16.8 13.7 21.1 1.38 12.2 85/71 17.8 14.1 22.2 1.39 12.8 75/63 16.2 13.4 20.3 1.31 12.3 80/67 17.2 13.9 21.4 1.32 13.0 85/71 18.4 14.3 22.5 1.32 13.9 75/63 16.3 13.5 20.3 1.29 12.6 80/67 17.4 13.9 21.4 1.30 13.4 85/71 18.5 14.3 22.6 1.30 14.2 75/63 14.8 12.9 19.5 1.49 9.9 80/67 15.8 13.3 20.5 1.51 10.4 85/71 16.8 13.7 21.6 1.53 10.9 75/63 15.2 13.0 19.7 1.44 10.5 80/67 16.2 13.5 20.8 1.45 11.1 85/71 17.3 14.0 21.9 1.47 11.8 75/63 15.3 13.1 19.7 1.42 10.7 80/67 16.4 13.5 20.9 1.44 11.4 85/71 17.4 14.0 22.0 1.45 12.0
Total
Capacity
(MBTUH)
Sensible Capacity (MBTUH)
Heat of Rejection (MBTUH)
Power
Input (kW)
EER
Entering
Temp (F)
Water
Fluid
30*
40*
50
60
70
80
* Extended Range - Antifreeze required for entering fl uid
temperture at or below 45 Degrees F.
AHRI/ISO13256-1 certified per formance is rated at entering air conditions
of 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Tabulated unit performance does not include fan or pump power
corrections required for AHRI/ISO standard performance ratings.
Unit performance may be interpolated. Extrapolation is not allowed.
Ratings below 40°F are with a methanol solution.
Due to variations in installation, actual performance may vary from the
tabulated data. Performance contained herein are as a result of extensive testing by FHP and are not express warranties between the parties and may be changed at any time.
Continuous research and development to improve our products may result
in a change to the current design and specifications without notice.
Pressure
Flow
(GPM)
Drop
(FOH)
2.5 3.4 1.5
4 7.9 3.4
5 11.9 5.1
2.5 3.3 1.4
4 7.7 3.3
5 11.4 5.0
2.5 3.2 1.4
4 7.4 3.2
5 11.1 4.8
2.5 3.1 1.3
4 7.1 3.1
5 10.7 4.6
2.5 3.0 1.3
4 6.9 3.0
5 10.3 4.5
2.5 2.9 1.2
4 6.7 2.9
5 10.0 4.3
Engineering Submittal Sheet
Pressure
Drop (PSI)
Entering
Air Temp
Total
Capacity
(F)
(MBTUH)
60 13.4 10.0 1.03 3.8
60 14.0 10.5 1.05 3.9
60 14.2 10.8 1.06 3.9
60 15.3 11.7 1.09 4.1
60 16.0 12.4 1.11 4.2
60 16.3 12.7 1.11 4.3
60 17.3 13.5 1.13 4.5
60 18.2 14.4 1.14 4.7
60 18.5 14.8 1.14 4.8
60 19.4 15.5 1.15 5.0
60 20.4 16.6 1.15 5.2
60 20.8 17.0 1.15 5.3
60 21.5 17.6 1.15 5.5
60 22.7 18.9 1.16 5.8
60 23.2 19.4 1.16 5.9
60 23.7 19.9 1.16 6.0
60 25.1 21.3 1.16 6.3
60 25.6 21.8 1.17 6.4
Heat of
Absorption
(MBTUH)
Power
Input
(kW)
COP
22 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 23
i Series Model BP
Residential Geothermal Heat Pumps
BP024 (800 CFM) Capacity Data
Entering
Fluid
Temp (F)
50
60
70
80
85
90
100
110
Water
Pressure
Flow
Drop
(GPM)
(FOH)
3 2.1 0.9
4 3.6 1.6
6 7.4 3.2
3 2.1 0.9
4 3.5 1.5
6 7.2 3.1
3 2 0.9
4 3.3 1.4
6 6.9 3.0
3 1.9 0.8
4 3.2 1.4
6 6.7 2.9
3 1.9 0.8
4 3.2 1.4
6 6.6 2.9
3 1.9 0.8
4 3.1 1.3
6 6.5 2.8
3 1.8 0.8
4 3 1.3
6 6.3 2.7
3 1.8 0.8
4 3 1.3
6 6.1 2.6
Pressure
Drop (PSI)
COOLING HEATING
Entering Air Temp
(db/wb) F
75/63 27.1 20.5 30.5 1.05 25.9 80/67 28.8 21.0 32.3 1.06 27.3 70 17.8 12.8 1.53 3.4 85/71 30.6 21.6 34.1 1.06 28.8 80 17.6 11.9 1.71 3.0 75/63 27.6 20.8 30.8 0.98 28.2 80/67 29.4 21.3 32.7 0.98 30.0 70 18.3 13.2 1.54 3.5 85/71 31.2 21.8 34.6 0.98 31.8 80 18.1 12.3 1.71 3.1 75/63 28.1 21.0 31.1 0.92 30.8 80/67 30.0 21.5 33.0 0.91 33.1 70 18.9 13.8 1.55 3.6 85/71 31.9 22.1 34.9 0.90 35.5 80 18.6 12.8 1.72 3.2 75/63 25.8 20.0 29.7 1.20 21.5 80/67 27.5 20.5 31.5 1.21 22.7 70 20.3 15.1 1.57 3.8 85/71 29.2 21.1 33.3 1.22 23.9 80 20.0 14.2 1.74 3.4 75/63 26.3 20.2 30.0 1.14 23.1 80/67 28.1 20.7 31.9 1.14 24.6 70 21.0 15.7 1.58 3.9 85/71 29.9 21.3 33.7 1.15 26.1 80 20.6 14.8 1.76 3.4 75/63 26.8 20.4 30.4 1.08 24.9 80/67 28.7 21.0 32.2 1.08 26.7 70 21.7 16.4 1.59 4.0 85/71 30.5 21.6 34.0 1.07 28.5 80 21.3 15.4 1.77 3.5 75/63 24.6 19.4 29.0 1.36 18.1 80/67 26.2 20.0 30.6 1.37 19.1 70 23.0 17.6 1.61 4.2 85/71 27.8 20.6 32.3 1.39 20.1 80 22.6 16.6 1.79 3.7 75/63 25.1 19.6 29.3 1.30 19.4 80/67 26.7 20.3 30.9 1.31 20.5 70 23.8 18.4 1.62 4.3 85/71 28.4 20.8 32.7 1.32 21.6 80 23.4 17.3 1.81 3.8 75/63 25.6 19.8 29.6 1.24 20.7 80/67 27.3 20.5 31.3 1.24 22.1 70 24.7 19.2 1.64 4.4 85/71 29.0 21.1 33.1 1.24 23.3 80 24.2 18.0 1.83 3.9 75/63 23.3 18.9 28.2 1.53 15.3 80/67 24.8 19.5 29.7 1.54 16.1 70 25.8 20.3 1.66 4.6 85/71 26.4 20.1 31.4 1.56 17.0 80 25.4 19.2 1.85 4.0 75/63 23.8 19.1 28.4 1.46 16.3 80/67 25.3 19.7 30.1 1.48 17.2 70 26.8 21.2 1.67 4.7 85/71 27.0 20.3 31.8 1.49 18.2 80 26.3 20.0 1.87 4.1 75/63 24.2 19.3 28.7 1.41 17.2 80/67 25.9 19.9 30.4 1.41 18.4 70 27.9 22.2 1.69 4.8 85/71 27.6 20.5 32.2 1.42 19.5 80 27.3 21.0 1.88 4.2 75/63 22.7 18.7 27.8 1.61 14.1 80/67 24.1 19.3 29.3 1.63 14.8 70 28.8 23.1 1.70 4.9 85/71 25.6 19.9 30.9 1.65 15.5 80 28.4 21.9 1.90 4.4 75/63 23.1 18.8 28.0 1.55 14.9 80/67 24.7 19.4 29.7 1.56 15.8 70 29.9 24.3 1.73 5.1 85/71 26.2 20.1 31.3 1.58 16.6 80 29.4 22.9 1.92 4.5 75/63 23.5 19.0 28.3 1.49 15.8 80/67 25.1 19.7 29.9 1.50 16.8 70 31.3 25.4 1.75 5.2 85/71 26.8 20.2 31.7 1.51 17.8 80 30.6 24.0 1.95 4.6 75/63 22.0 18.4 27.4 1.71 12.9 80/67 23.5 19.0 29.0 1.72 13.7 70 31.9 26.0 1.76 5.3 85/71 24.9 19.6 30.5 1.74 14.3 80 31.4 24.7 1.97 4.7 75/63 22.5 18.6 27.7 1.64 13.7 80/67 23.9 19.2 29.2 1.66 14.5 70 33.3 27.3 1.79 5.4 85/71 25.5 19.7 30.9 1.67 15.3 80 32.6 25.9 2.00 4.8 75/63 22.9 18.7 27.9 1.59 14.5 80/67 24.4 19.3 29.5 1.59 15.3 70 34.8 28.6 1.83 5.6 85/71 26.0 20.0 31.2 1.60 16.2 80 34.0 27.1 2.04 4.9 75/63 20.8 17.8 26.7 1.90 10.9 80/67 22.1 18.5 28.2 1.92 11.5 85/71 23.5 19.1 29.7 1.94 12.1 75/63 21.2 18.0 27.0 1.84 11.5 80/67 22.5 18.7 28.4 1.86 12.1 85/71 24.0 19.3 29.9 1.87 12.8 75/63 21.5 18.2 27.2 1.78 12.1 80/67 23.0 18.8 28.7 1.79 12.9 85/71 24.5 19.4 30.2 1.81 13.6 75/63 19.4 17.3 26.1 2.13 9.2 80/67 20.8 17.9 27.5 2.14 9.7 85/71 22.1 18.6 29.0 2.16 10.3 75/63 19.8 17.5 26.2 2.06 9.6 80/67 21.1 18.1 27.7 2.07 10.2 85/71 22.5 18.8 29.1 2.08 10.8 75/63 20.1 17.6 26.4 2.01 10.0 80/67 21.5 18.2 27.9 2.01 10.7 85/71 23.0 18.9 29.4 2.02 11.4
Total
Capacity
(MBTUH)
Sensible Capacity (MBTUH)
Heat of Rejection (MBTUH)
Power
Input (kW)
EER
Entering
Temp (F)
Water
Fluid
30*
40*
50
60
70
80
* Extended Range - Antifreeze required for entering fl uid
temperture at or below 45 Degrees F.
AHRI/ISO13256-1 certified per formance is rated at entering air conditions
of 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Tabulated unit performance does not include fan or pump power
corrections required for AHRI/ISO standard performance ratings.
Unit performance may be interpolated. Extrapolation is not allowed.
Ratings below 40°F are with a methanol solution.
Due to variations in installation, actual performance may vary from the
tabulated data. Performance contained herein are as a result of extensive testing by FHP and are not express warranties between the parties and may be changed at any time.
Continuous research and development to improve our products may result
in a change to the current design and specifications without notice.
Pressure
Flow
(GPM)
Drop
(FOH)
3 2.2 1.0
4 3.8 1.6
6 7.8 3.4
3 2.2 0.9
4 3.6 1.6
6 7.5 3.3
3 2.1 0.9
4 3.5 1.5
6 7.3 3.1
3 2.0 0.9
4 3.4 1.5
6 7.0 3.0
3 2.0 0.8
4 3.3 1.4
6 6.8 2.9
3 1.9 0.8
4 3.2 1.4
6 6.6 2.8
Engineering Submittal Sheet
Pressure
Drop (PSI)
Entering
Air Temp
Total
Capacity
(F)
(MBTUH)
60 18.2 13.6 1.38 3.9
60 18.7 14.1 1.38 3.9
60 19.3 14.7 1.39 4.1
60 20.7 16.0 1.41 4.3
60 21.3 16.6 1.41 4.4
60 22.1 17.4 1.42 4.5
60 23.4 18.6 1.44 4.8
60 24.2 19.4 1.45 4.9
60 25.2 20.3 1.46 5.0
60 26.3 21.3 1.48 5.2
60 27.3 22.3 1.50 5.3
60 28.5 23.4 1.51 5.5
60 29.3 24.2 1.52 5.6
60 30.6 25.4 1.54 5.8
60 32.0 26.8 1.57 6.0
60 32.5 27.2 1.58 6.0
60 33.9 28.6 1.60 6.2
60 35.5 30.4 1.64 6.3
Heat of
Absorption
(MBTUH)
Power
Input
(kW)
COP
23 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 24
i Series Model BP
Residential Geothermal Heat Pumps
BP030 (1000 CFM) Capacity Data
Entering
Fluid
Temp (F)
50
60
70
80
85
90
100
110
Water
Pressure
Flow
Drop
(GPM)
(FOH)
4 1.3 0.6
6 2.6 1.1
8 4.4 1.9
4 1.2 0.5
6 2.5 1.1
8 4.3 1.9
4 1.2 0.5
6 2.5 1.1
8 4.1 1.8
4 1.1 0.5
6 2.4 1.0
8 4 1.7
4 1.1 0.5
6 2.3 1.0
8 3.9 1.7
4 1.1 0.5
6 2.3 1.0
8 3.9 1.7
4 1.1 0.5
6 2.2 1.0
8 3.7 1.6
4 1 0.4
6 2.2 1.0
8 3.6 1.6
Pressure
Drop (PSI)
COOLING HEATING
Entering Air Temp
(db/wb) F
75/63 30.0 24.0 34.0 1.23 24.5 80/67 31.9 24.6 36.1 1.27 25.2 70 19.4 14.1 1.60 3.6 85/71 33.8 25.4 38.1 1.31 25.8 80 19.0 13.0 1.78 3.1 75/63 30.9 24.3 34.6 1.14 27.2 80/67 32.8 25.0 36.7 1.17 28.1 70 20.0 14.6 1.60 3.7 85/71 34.8 25.7 38.9 1.21 28.7 80 19.6 13.3 1.78 3.2 75/63 31.3 24.5 34.9 1.09 28.8 80/67 33.2 25.2 36.9 1.12 29.7 70 20.5 15.2 1.60 3.8 85/71 35.3 25.9 39.2 1.16 30.5 80 19.8 14.0 1.78 3.2 75/63 28.7 23.4 33.1 1.38 20.8 80/67 30.4 24.2 35.0 1.42 21.5 70 21.8 16.5 1.60 4.0 85/71 32.3 24.9 37.1 1.47 22.0 80 21.5 15.3 1.79 3.5 75/63 29.5 23.7 33.7 1.29 22.9 80/67 31.4 24.4 35.7 1.33 23.7 70 22.8 17.3 1.60 4.2 85/71 33.2 25.2 37.7 1.37 24.3 80 22.3 16.2 1.79 3.6 75/63 29.9 23.9 33.9 1.25 24.0 80/67 31.7 24.7 35.9 1.28 24.9 70 23.3 17.8 1.60 4.3 85/71 33.8 25.3 38.2 1.32 25.7 80 22.5 16.6 1.79 3.7 75/63 27.3 22.8 32.3 1.54 17.7 80/67 29.0 23.6 34.1 1.58 18.4 70 24.9 19.3 1.61 4.5 85/71 30.8 24.4 36.1 1.63 18.9 80 24.3 18.1 1.81 3.9 75/63 28.0 23.1 32.7 1.46 19.3 80/67 29.9 23.9 34.7 1.49 20.1 70 26.0 20.8 1.62 4.7 85/71 31.7 24.7 36.7 1.53 20.7 80 25.6 19.6 1.82 4.1 75/63 28.4 23.3 32.9 1.41 20.1 80/67 30.3 24.0 35.0 1.44 21.0 70 26.5 20.8 1.63 4.8 85/71 32.2 24.8 37.1 1.48 21.7 80 25.9 19.7 1.82 4.2 75/63 25.9 22.3 31.4 1.72 15.1 80/67 27.6 23.0 33.2 1.76 15.7 70 27.9 22.2 1.64 5.0 85/71 29.3 23.8 35.1 1.81 16.2 80 27.3 21.0 1.84 4.4 75/63 26.6 22.6 31.8 1.63 16.3 80/67 28.3 23.3 33.7 1.67 17.0 70 29.3 23.5 1.66 5.2 85/71 30.2 24.0 35.7 1.71 17.7 80 28.8 22.5 1.86 4.5 75/63 26.9 22.7 32.0 1.59 16.9 80/67 28.7 23.4 34.0 1.62 17.7 70 30.0 24.3 1.67 5.2 85/71 30.6 24.3 36.0 1.66 18.5 80 29.4 22.9 1.87 4.6 75/63 25.2 22.0 31.0 1.82 13.9 80/67 26.8 22.8 32.8 1.85 14.5 70 31.2 25.4 1.70 5.4 85/71 28.6 23.5 34.7 1.91 15.0 80 30.6 24.1 1.89 4.7 75/63 25.9 22.2 31.4 1.73 15.0 80/67 27.6 23.1 33.2 1.76 15.7 70 33.2 27.6 1.74 5.6 85/71 29.4 23.8 35.2 1.80 16.3 80 32.2 25.5 1.93 4.9 75/63 26.2 22.4 31.6 1.68 15.6 80/67 27.9 23.2 33.4 1.71 16.3 70 34.1 28.5 1.77 5.7 85/71 29.8 23.9 35.4 1.75 17.0 80 33.5 27.3 1.97 5.0 75/63 24.5 21.7 30.5 1.92 12.8 80/67 26.1 22.5 32.3 1.96 13.4 70 34.9 28.7 1.79 5.7 85/71 27.8 23.3 34.2 2.00 13.9 80 34.2 27.3 1.99 5.0 75/63 25.2 21.9 31.0 1.83 13.8 80/67 26.8 22.8 32.7 1.86 14.4 70 36.9 30.5 1.86 5.8 85/71 28.5 23.6 34.6 1.90 15.0 80 36.1 29.0 2.06 5.1 75/63 25.5 22.1 31.2 1.78 14.3 80/67 27.2 22.9 33.0 1.81 15.0 70 38.5 32.1 1.91 5.9 85/71 29.0 23.6 34.9 1.85 15.7 80 37.7 31.3 2.12 5.2 75/63 23.0 21.1 29.7 2.14 10.8 80/67 24.6 22.0 31.5 2.17 11.3 85/71 26.2 22.8 33.2 2.22 11.8 75/63 23.6 21.4 30.1 2.04 11.6 80/67 25.3 22.1 31.9 2.08 12.2 85/71 26.9 23.0 33.7 2.12 12.7 75/63 23.9 21.5 30.2 2.00 12.0 80/67 25.6 22.3 32.1 2.03 12.6 85/71 27.3 23.2 33.9 2.07 13.2 75/63 21.5 20.5 29.0 2.39 9.0 80/67 23.0 21.4 30.7 2.42 9.5 85/71 24.6 22.2 32.4 2.45 10.0 75/63 22.1 20.8 29.3 2.29 9.7 80/67 23.6 21.6 31.0 2.32 10.2 85/71 25.3 22.5 32.8 2.35 10.8 75/63 22.4 20.8 29.5 2.25 10.0 80/67 23.9 21.7 31.1 2.27 10.5 85/71 25.6 22.6 32.9 2.30 11.1
Total
Capacity
(MBTUH)
Sensible Capacity (MBTUH)
Heat of Rejection (MBTUH)
Power
Input (kW)
EER
Entering
Temp (F)
Water
Fluid
30*
40*
50
60
70
80
* Extended Range - Antifreeze required for entering fl uid
temperture at or below 45 Degrees F.
AHRI/ISO13256-1 certified per formance is rated at entering air conditions
of 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Tabulated unit performance does not include fan or pump power
corrections required for AHRI/ISO standard performance ratings.
Unit performance may be interpolated. Extrapolation is not allowed.
Ratings below 40°F are with a methanol solution.
Due to variations in installation, actual performance may vary from the
tabulated data. Performance contained herein are as a result of extensive testing by FHP and are not express warranties between the parties and may be changed at any time.
Continuous research and development to improve our products may result
in a change to the current design and specifications without notice.
Pressure
Flow
(GPM)
Drop
(FOH)
4 1.3 0.6
6 2.8 1.2
8 4.7 2.0
4 1.3 0.6
6 2.7 1.2
8 4.5 1.9
4 1.2 0.5
6 2.6 1.1
8 4.3 1.9
4 1.2 0.5
6 2.5 1.1
8 4.2 1.8
4 1.2 0.5
6 2.4 1.0
8 4.1 1.8
4 1.1 0.5
6 2.3 1.0
8 3.9 1.7
Engineering Submittal Sheet
Pressure
Drop (PSI)
Entering
Air Temp
Total
Capacity
(F)
(MBTUH)
60 19.8 15.0 1.43 4.1
60 20.5 15.7 1.43 4.2
60 21.0 16.1 1.43 4.3
60 22.4 17.6 1.43 4.6
60 23.4 18.5 1.43 4.8
60 23.9 19.2 1.43 4.9
60 25.3 20.4 1.43 5.2
60 26.5 21.6 1.44 5.4
60 27.2 22.5 1.45 5.5
60 28.6 23.7 1.46 5.7
60 30.1 25.1 1.48 5.9
60 30.8 25.9 1.50 6.0
60 32.1 26.9 1.52 6.2
60 33.7 28.4 1.55 6.4
60 34.8 29.6 1.58 6.4
60 35.8 30.4 1.60 6.5
60 37.7 32.1 1.67 6.6
60 39.2 33.4 1.72 6.7
Heat of
Absorption
(MBTUH)
Power
Input
(kW)
COP
24 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 25
i Series Model BP
Residential Geothermal Heat Pumps
BP036 (1200 CFM) Capacity Data
Entering
Fluid
Temp (F)
50
60
70
80
85
90
100
110
Water
Pressure
Flow
Drop
(GPM)
(FOH)
4.5 2.1 0.9
6 3.4 1.5
9 7.2 3.1
4.5 2 0.9
6 3.3 1.4
9 6.9 3.0
4.5 1.9 0.8
6 3.2 1.4
9 6.7 2.9
4.5 1.9 0.8
6 3.1 1.3
9 6.5 2.8
4.5 1.8 0.8
6 3.1 1.3
9 6.4 2.8
4.5 1.8 0.8
6 3 1.3
9 6.3 2.7
4.5 1.7 0.7
6 2.9 1.3
9 6.1 2.6
4.5 1.7 0.7
6 2.8 1.2
9 5.9 2.6
Pressure
Drop
(PSI)
COOLING HEATING
Entering
Air Temp
(db/wb) F
75/63 37.1 29.1 42.4 1.64 22.6 80/67 39.4 30.0 44.8 1.66 23.7 70 25.7 18.8 2.09 3.6 85/71 42.0 30.7 47.5 1.68 24.9 80 25.2 17.4 2.31 3.2 75/63 37.8 29.4 42.9 1.56 24.2 80/67 40.3 30.3 45.4 1.58 25.6 70 26.7 19.4 2.10 3.7 85/71 42.9 31.2 48.1 1.59 27.0 80 26.0 18.4 2.32 3.3 75/63 38.6 29.7 43.4 1.48 26.1 80/67 41.2 30.6 46.1 1.48 27.7 70 27.8 20.5 2.12 3.8 85/71 43.9 31.4 48.9 1.49 29.4 80 27.1 19.4 2.34 3.4 75/63 35.4 28.4 41.3 1.81 19.5 80/67 37.8 29.2 43.7 1.84 20.6 70 29.2 21.5 2.14 4.0 85/71 40.1 30.2 46.1 1.86 21.6 80 28.3 20.6 2.36 3.5 75/63 36.2 28.7 41.8 1.74 20.8 80/67 38.5 29.6 44.2 1.75 22.0 70 30.6 22.6 2.16 4.2 85/71 41.0 30.5 46.8 1.77 23.2 80 29.7 21.6 2.37 3.7 75/63 36.9 29.0 42.3 1.66 22.3 80/67 39.5 29.9 44.9 1.67 23.7 70 31.4 24.3 2.17 4.2 85/71 42.0 30.8 47.5 1.67 25.1 80 31.1 22.8 2.39 3.8 75/63 33.9 27.8 40.3 2.00 17.0 80/67 36.1 28.7 42.6 2.02 17.9 70 32.9 25.5 2.19 4.4 85/71 38.4 29.6 45.0 2.04 18.8 80 32.3 24.4 2.41 3.9 75/63 34.5 28.0 40.6 1.92 18.0 80/67 36.8 28.9 43.0 1.94 19.0 70 34.4 27.0 2.21 4.6 85/71 39.2 29.9 45.6 1.95 20.1 80 33.8 25.6 2.43 4.1 75/63 35.2 28.3 41.1 1.84 19.1 80/67 37.6 29.2 43.6 1.85 20.3 70 35.7 28.4 2.23 4.7 85/71 40.0 30.1 46.1 1.86 21.5 80 35.0 27.0 2.45 4.2 75/63 32.1 27.0 39.1 2.19 14.6 80/67 34.2 28.0 41.3 2.22 15.4 70 36.9 29.7 2.24 4.8 85/71 36.4 28.9 43.7 2.24 16.2 80 36.3 28.0 2.47 4.3 75/63 32.7 27.3 39.5 2.11 15.4 80/67 35.0 28.3 41.9 2.13 16.4 70 38.7 30.8 2.26 5.0 85/71 37.3 29.2 44.2 2.15 17.3 80 37.8 29.7 2.49 4.5 75/63 33.5 27.4 40.0 2.04 16.4 80/67 35.8 28.5 42.4 2.05 17.4 70 40.9 33.3 2.29 5.2 85/71 38.2 29.4 44.9 2.06 18.5 80 39.7 31.0 2.52 4.6 75/63 31.2 26.7 38.6 2.30 13.5 80/67 33.3 27.6 40.7 2.32 14.3 70 41.4 33.6 2.30 5.3 85/71 35.4 28.5 43.0 2.35 15.1 80 40.5 32.2 2.53 4.7 75/63 31.9 27.0 39.0 2.22 14.4 80/67 34.0 27.9 41.2 2.24 15.2 70 43.3 34.9 2.33 5.5 85/71 36.6 28.1 43.9 2.26 16.2 80 42.4 33.7 2.56 4.9 75/63 32.5 27.2 39.4 2.14 15.2 80/67 34.8 28.2 41.7 2.15 16.1 70 45.6 38.5 2.37 5.6 85/71 37.1 29.1 44.1 2.16 17.1 80 44.7 36.2 2.60 5.0 75/63 30.3 26.3 38.0 2.41 12.5 80/67 32.4 27.3 40.1 2.44 13.3 70 46.2 38.1 2.37 5.7 85/71 34.6 28.2 42.4 2.46 14.1 80 45.3 36.4 2.61 5.1 75/63 31.0 26.6 38.4 2.33 13.3 80/67 33.1 27.5 40.7 2.35 14.1 70 48.1 40.4 2.41 5.9 85/71 35.2 28.5 42.8 2.37 14.8 80 47.1 38.8 2.65 5.2 75/63 31.6 26.9 38.8 2.25 14.0 80/67 33.8 27.8 41.0 2.26 14.9 70 51.4 43.3 2.46 6.1 85/71 35.8 28.7 43.2 2.28 15.7 80 49.7 40.1 2.69 5.4 75/63 28.6 25.6 37.0 2.66 10.7 80/67 30.5 26.6 39.1 2.68 11.4 85/71 32.6 27.6 41.2 2.69 12.1 75/63 29.2 25.9 37.4 2.58 11.3 80/67 31.2 26.8 39.4 2.59 12.0 85/71 33.4 27.7 41.7 2.60 12.8 75/63 29.8 26.1 37.7 2.49 11.9 80/67 31.9 27.0 39.9 2.51 12.7 85/71 34.0 28.1 42.1 2.51 13.5 75/63 26.8 24.2 36.2 2.94 9.1 80/67 28.7 25.9 38.1 2.95 9.7 85/71 30.8 26.8 40.3 2.97 10.4 75/63 27.4 24.4 36.4 2.85 9.6 80/67 29.3 26.1 38.4 2.86 10.2 85/71 31.3 27.1 40.5 2.87 10.9 75/63 27.9 25.3 36.7 2.77 10.1 80/67 29.9 26.4 38.7 2.77 10.8 85/71 32.0 27.4 40.8 2.77 11.5
Total Capacity (MBTUH)
Sensible Capacity
(MBTUH)
Heat of
Rejection
(MBTUH)
Power
Input
(kW)
EER
Entering
Temp (F)
Water
Fluid
30*
40*
50
60
70
80
* Extended Range - Antifreeze required for entering fl uid
temperture at or below 45 Degrees F.
AHRI/ISO13256-1 certified per formance is rated at entering air conditions
of 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Tabulated unit performance does not include fan or pump power
corrections required for AHRI/ISO standard performance ratings.
Unit performance may be interpolated. Extrapolation is not allowed.
Ratings below 40°F are with a methanol solution.
Due to variations in installation, actual performance may vary from the
tabulated data. Performance contained herein are as a result of extensive testing by FHP and are not express warranties between the parties and may be changed at any time.
Continuous research and development to improve our products may result
in a change to the current design and specifications without notice.
Pressure
Flow
(GPM)
Drop
(FOH)
4.5 1.5 0.7
6 2.6 1.1
9 5.3 2.3
4.5 1.5 0.6
6 2.5 1.1
9 5.1 2.2
4.5 1.4 0.6
6 2.4 1.0
9 5.0 2.2
4.5 1.4 0.6
6 2.3 1.0
9 4.8 2.1
4.5 1.3 0.6
6 2.2 1.0
9 4.6 2.0
4.5 1.3 0.6
6 2.2 0.9
9 4.5 1.9
Engineering Submittal Sheet
Pressure
Drop
(PSI)
Entering Air Temp
Total
Capacity
(F)
(MBTUH)
60 26.3 20.0 1.90 4.1
60 27.0 20.4 1.91 4.2
60 28.3 21.7 1.92 4.3
60 29.5 23.1 1.94 4.5
60 30.8 24.6 1.96 4.6
60 32.1 25.3 1.97 4.8
60 33.7 26.9 1.99 5.0
60 35.0 28.4 2.01 5.1
60 36.6 29.6 2.03 5.3
60 37.8 30.8 2.04 5.4
60 39.6 32.6 2.06 5.6
60 41.6 34.6 2.08 5.9
60 42.3 35.1 2.09 5.9
60 44.4 37.5 2.12 6.1
60 47.4 40.4 2.16 6.4
60 47.0 39.6 2.16 6.4
60 49.1 41.8 2.19 6.6
60 52.8 45.3 2.24 6.9
Heat of
Absorption
(MBTUH)
Power
Input (kW)
COP
25 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 26
i Series Model BP
Residential Geothermal Heat Pumps
BP042 (1400 CFM) Capacity Data
Entering
Fluid
Temp (F)
50
60
70
80
85
90
100
110
Water
Pressure
Flow
Drop
(GPM)
(FOH)
5 1.5 0.6
8 3.5 1.5
11 6.2 2.7
5 1.4 0.6
8 3.4 1.5
11 6 2.6
5 1.4 0.6
8 3.3 1.4
11 5.8 2.5
5 1.4 0.6
8 3.2 1.4
11 5.6 2.4
5 1.3 0.6
8 3.1 1.3
11 5.5 2.4
5 1.3 0.6
8 3.1 1.3
11 5.4 2.3
5 1.3 0.6
8 3 1.3
11 5.3 2.3
5 1.2 0.5
8 2.9 1.3
11 5.1 2.2
Pressure
Drop (PSI)
COOLING HEATING
Entering Air Temp
(db/wb) F
75/63 43.5 34.3 49.1 1.68 25.8 80/67 46.3 35.4 51.9 1.70 27.3 70 25.5 18.8 2.09 3.6 85/71 49.2 36.3 55.0 1.72 28.6 80 25.0 17.5 2.33 3.1 75/63 45.0 35.0 50.1 1.53 29.4 80/67 48.1 36.0 53.2 1.54 31.3 70 26.9 20.2 2.11 3.7 85/71 51.0 37.0 56.2 1.54 33.2 80 26.3 18.8 2.35 3.3 75/63 45.8 35.2 50.7 1.46 31.4 80/67 48.8 36.4 53.7 1.45 33.6 70 27.7 20.9 2.11 3.8 85/71 52.0 37.4 56.9 1.45 35.9 80 27.0 19.4 2.35 3.4 75/63 41.6 33.4 47.8 1.88 22.1 80/67 44.3 34.5 50.6 1.90 23.3 70 29.2 21.9 2.12 4.0 85/71 47.1 35.5 53.4 1.92 24.5 80 28.8 20.9 2.37 3.6 75/63 43.0 34.0 48.8 1.74 24.7 80/67 45.9 35.1 51.7 1.74 26.3 70 30.8 23.8 2.15 4.2 85/71 48.9 36.1 54.7 1.75 27.9 80 30.3 22.2 2.39 3.7 75/63 43.7 34.3 49.3 1.67 26.2 80/67 46.6 35.5 52.2 1.67 27.9 70 31.7 24.9 2.16 4.3 85/71 49.7 36.5 55.3 1.67 29.7 80 31.0 23.3 2.40 3.8 75/63 39.5 32.7 46.3 2.08 19.0 80/67 42.1 33.8 49.0 2.10 20.0 70 33.3 26.0 2.17 4.5 85/71 44.9 34.7 51.9 2.13 21.1 80 32.3 24.1 2.42 3.9 75/63 40.9 33.2 47.3 1.95 21.0 80/67 43.6 34.3 50.1 1.95 22.3 70 35.1 27.4 2.20 4.7 85/71 46.5 35.4 53.0 1.97 23.7 80 34.3 26.3 2.44 4.1 75/63 41.5 33.5 47.7 1.88 22.1 80/67 44.4 34.5 50.7 1.89 23.6 70 36.5 29.4 2.21 4.8 85/71 47.3 35.7 53.6 1.89 25.0 80 35.4 27.5 2.46 4.2 75/63 37.5 31.8 45.0 2.31 16.3 80/67 40.0 32.9 47.6 2.33 17.2 70 37.4 30.0 2.23 4.9 85/71 42.5 34.0 50.2 2.35 18.1 80 36.7 28.7 2.47 4.3 75/63 38.8 32.4 45.8 2.16 17.9 80/67 41.5 33.4 48.6 2.18 19.1 70 40.1 33.2 2.26 5.2 85/71 44.2 34.5 51.4 2.19 20.2 80 38.6 30.6 2.50 4.5 75/63 39.4 32.6 46.2 2.10 18.8 80/67 42.1 33.8 49.0 2.11 20.0 70 41.0 33.8 2.27 5.3 85/71 45.0 34.7 52.0 2.12 21.3 80 40.1 32.1 2.52 4.7 75/63 36.4 31.4 44.3 2.42 15.0 80/67 39.0 32.5 46.9 2.44 16.0 70 41.7 34.6 2.29 5.3 85/71 41.4 33.6 49.4 2.47 16.8 80 41.1 32.8 2.53 4.8 75/63 37.8 31.8 45.2 2.28 16.6 80/67 40.3 33.0 47.8 2.29 17.6 70 45.5 37.8 2.33 5.7 85/71 43.0 34.2 50.5 2.30 18.7 80 44.3 36.0 2.58 5.0 75/63 38.3 32.2 45.5 2.22 17.3 80/67 41.0 33.2 48.3 2.22 18.4 70 46.1 40.0 2.36 5.7 85/71 43.7 34.4 51.0 2.23 19.6 80 45.2 37.0 2.60 5.1 75/63 35.5 30.9 43.7 2.55 13.9 80/67 37.8 32.2 46.1 2.57 14.7 70 46.9 38.9 2.36 5.8 85/71 40.2 33.3 48.7 2.59 15.5 80 45.9 37.1 2.61 5.2 75/63 36.6 31.5 44.4 2.40 15.2 80/67 39.2 32.7 47.0 2.41 16.2 70 47.9 42.5 2.37 5.9 85/71 41.8 33.8 49.7 2.43 17.2 80 48.9 40.6 2.67 5.4 75/63 37.2 31.7 44.8 2.34 15.9 80/67 39.8 32.9 47.4 2.34 17.0 70 52.7 45.1 2.45 6.3 85/71 42.5 34.0 50.2 2.35 18.1 80 51.3 42.3 2.71 5.6 75/63 33.4 30.2 42.4 2.81 11.9 80/67 35.6 31.3 44.8 2.84 12.6 85/71 38.0 32.5 47.3 2.86 13.3 75/63 34.5 30.5 43.1 2.67 12.9 80/67 36.9 31.8 45.5 2.68 13.8 85/71 39.4 33.0 48.2 2.69 14.6 75/63 34.9 30.8 43.3 2.61 13.4 80/67 37.5 31.9 46.0 2.61 14.4 85/71 40.1 33.2 48.6 2.62 15.3 75/63 31.3 29.3 41.3 3.11 10.1 80/67 33.5 30.6 43.6 3.14 10.7 85/71 35.4 31.6 45.6 3.16 11.2 75/63 32.3 29.7 41.8 2.96 10.9 80/67 34.7 30.9 44.3 2.98 11.7 85/71 37.0 32.1 46.8 2.99 12.4 75/63 32.8 29.9 42.2 2.90 11.3 80/67 35.2 31.1 44.6 2.91 12.1 85/71 37.6 32.3 47.1 2.92 12.9
Total
Capacity
(MBTUH)
Sensible Capacity
(MBTUH)
Heat of Rejection (MBTUH)
Power
Input (kW)
EER
Entering
Temp (F)
Water
Fluid
30*
40*
50
60
70
80
* Extended Range - Antifreeze required for entering fl uid
temperture at or below 45 Degrees F.
AHRI/ISO13256-1 certified per formance is rated at entering air conditions
of 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Tabulated unit performance does not include fan or pump power
corrections required for AHRI/ISO standard performance ratings.
Unit performance may be interpolated. Extrapolation is not allowed.
Ratings below 40°F are with a methanol solution.
Due to variations in installation, actual performance may vary from the
tabulated data. Performance contained herein are as a result of extensive testing by FHP and are not express warranties between the parties and may be changed at any time.
Continuous research and development to improve our products may result
in a change to the current design and specifications without notice.
Pressure
Flow
(GPM)
Drop
(FOH)
5 1.9 0.8
8 4.3 1.9
11 7.7 3.3
5 1.8 0.8
8 4.2 1.8
11 7.4 3.2
5 1.7 0.7
8 4.0 1.7
11 7.1 3.1
5 1.7 0.7
8 3.9 1.7
11 6.9 3.0
5 1.6 0.7
8 3.8 1.6
11 6.7 2.9
5 1.6 0.7
8 3.6 1.6
11 6.5 2.8
Engineering Submittal Sheet
Pressure
Drop
(PSI)
Entering
Air Temp
Total
Capacity
(F)
(MBTUH)
60 26.2 20.3 1.87 4.1
60 27.6 21.6 1.89 4.3
60 28.4 22.4 1.90 4.4
60 29.9 23.7 1.91 4.6
60 31.7 25.1 1.92 4.8
60 32.8 26.3 1.94 5.0
60 33.9 27.4 1.95 5.1
60 36.1 29.7 1.97 5.4
60 37.2 30.7 1.99 5.5
60 38.2 31.6 2.00 5.6
60 41.3 35.1 2.04 5.9
60 42.5 35.7 2.05 6.1
60 43.0 36.1 2.06 6.1
60 46.5 39.0 2.10 6.5
60 48.1 40.8 2.12 6.6
60 47.9 40.8 2.12 6.6
60 52.6 44.6 2.18 7.1
60 53.9 48.1 2.22 7.1
Heat of
Absorption
(MBTUH)
Power
Input
(kW)
COP
26 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 27
i Series Model BP
Residential Geothermal Heat Pumps
BP048 (1600 CFM) Capacity Data
Entering
Fluid
Temp (F)
50
60
70
80
85
90
100
110
Water
Pressure
Flow
Drop
(GPM)
(FOH)
6 3.6 1.6
8 6 2.6
12 12.4 5.4
6 3.4 1.5
8 5.8 2.5
12 12 5.2
6 3.3 1.4
8 5.6 2.4
12 11.6 5.0
6 3.2 1.4
8 5.4 2.3
12 11.2 4.8
6 3.2 1.4
8 5.3 2.3
12 11 4.8
6 3.1 1.3
8 5.2 2.3
12 10.8 4.7
6 3 1.3
8 5.1 2.2
12 10.5 4.5
6 2.9 1.3
8 4.9 2.1
12 10.2 4.4
Pressure
Drop (PSI)
COOLING HEATING
Entering Air Temp
(db/wb) F
75/63 49.9 39.2 56.9 2.14 23.3 80/67 53.3 40.3 60.2 2.13 25.1 70 32.1 23.1 2.66 3.5 85/71 56.6 41.4 63.6 2.10 26.9 80 31.5 21.8 2.95 3.1 75/63 50.9 39.6 57.6 2.04 25.0 80/67 54.4 40.7 61.1 2.01 27.0 70 33.1 24.0 2.68 3.6 85/71 57.9 41.9 64.5 1.98 29.2 80 32.6 22.7 2.97 3.2 75/63 52.1 40.0 58.5 1.94 26.9 80/67 55.6 41.3 61.9 1.90 29.2 70 34.3 25.4 2.70 3.7 85/71 59.3 42.4 65.5 1.86 31.9 80 33.8 23.9 3.00 3.3 75/63 47.8 38.2 55.5 2.37 20.1 80/67 50.9 39.5 58.6 2.36 21.5 70 36.5 27.4 2.74 3.9 85/71 54.2 40.5 61.9 2.35 23.1 80 35.9 25.9 3.04 3.5 75/63 48.8 38.6 56.2 2.26 21.6 80/67 52.1 39.8 59.5 2.24 23.2 70 37.7 28.5 2.76 4.0 85/71 55.4 41.1 62.7 2.22 25.0 80 37.3 26.6 3.07 3.6 75/63 49.8 39.1 56.8 2.15 23.1 80/67 53.2 40.4 60.2 2.12 25.1 70 39.2 29.9 2.79 4.1 85/71 56.7 41.6 63.6 2.09 27.2 80 38.6 28.3 3.10 3.7 75/63 45.5 37.3 54.0 2.64 17.3 80/67 48.6 38.5 57.2 2.63 18.5 70 41.3 31.8 2.83 4.3 85/71 51.6 39.8 60.2 2.62 19.7 80 41.0 30.2 3.13 3.8 75/63 46.5 37.7 54.6 2.52 18.5 80/67 49.6 39.0 57.8 2.50 19.8 70 42.9 33.3 2.85 4.4 85/71 52.9 40.2 61.0 2.48 21.3 80 42.2 31.6 3.16 3.9 75/63 47.5 38.1 55.3 2.40 19.8 80/67 50.7 39.4 58.5 2.38 21.3 70 44.6 35.3 2.88 4.5 85/71 54.1 40.7 61.8 2.35 23.1 80 43.8 33.2 3.19 4.0 75/63 43.3 36.4 52.7 2.93 14.8 80/67 46.2 37.7 55.6 2.93 15.8 70 47.0 36.9 2.91 4.7 85/71 49.2 38.8 58.7 2.93 16.8 80 45.9 34.9 3.22 4.2 75/63 44.2 36.7 53.3 2.81 15.7 80/67 47.2 38.1 56.2 2.80 16.9 70 48.5 38.6 2.93 4.8 85/71 50.4 39.2 59.4 2.78 18.1 80 47.7 37.0 3.26 4.3 75/63 45.2 37.1 53.8 2.69 16.8 80/67 48.3 38.4 57.0 2.67 18.1 70 50.6 41.0 2.96 5.0 85/71 51.5 39.7 60.1 2.64 19.5 80 49.9 38.3 3.28 4.5 75/63 42.1 36.0 52.0 3.09 13.6 80/67 45.0 37.1 55.0 3.09 14.5 70 52.1 42.1 2.98 5.1 85/71 47.8 38.5 57.8 3.09 15.5 80 51.3 40.1 3.31 4.5 75/63 43.0 36.3 52.5 2.97 14.5 80/67 45.9 37.6 55.5 2.96 15.5 70 54.8 44.9 3.01 5.3 85/71 49.0 38.8 58.5 2.94 16.6 80 53.4 42.2 3.34 4.7 75/63 44.0 36.6 53.1 2.85 15.5 80/67 47.0 37.9 56.2 2.83 16.6 70 57.0 46.8 3.03 5.5 85/71 50.1 39.2 59.2 2.80 17.9 80 55.8 44.4 3.37 4.9 75/63 41.0 35.4 51.5 3.26 12.6 80/67 43.7 36.8 54.2 3.26 13.4 70 57.9 47.6 3.04 5.6 85/71 46.7 37.9 57.2 3.26 14.3 80 56.9 45.4 3.38 4.9 75/63 41.8 35.8 51.9 3.14 13.3 80/67 44.7 37.1 54.8 3.13 14.3 70 60.5 50.2 3.06 5.8 85/71 47.6 38.4 57.7 3.11 15.3 80 59.5 47.8 3.41 5.1 75/63 42.8 36.1 52.4 3.01 14.2 80/67 45.7 37.5 55.3 2.99 15.3 70 63.3 53.0 3.09 6.0 85/71 48.8 38.6 58.5 2.97 16.4 80 61.9 50.4 3.44 5.3 75/63 38.7 34.4 50.3 3.63 10.7 80/67 41.3 35.8 52.9 3.63 11.4 85/71 43.9 37.1 55.6 3.63 12.1 75/63 39.5 34.8 50.7 3.50 11.3 80/67 42.1 36.2 53.3 3.49 12.1 85/71 44.9 37.4 56.1 3.48 12.9 75/63 40.3 35.1 51.1 3.38 11.9 80/67 43.1 36.5 53.9 3.36 12.8 85/71 46.0 37.8 56.8 3.34 13.8 75/63 36.2 33.5 49.0 4.02 9.0 80/67 38.7 34.9 51.6 4.03 9.6 85/71 41.1 36.2 54.1 4.03 10.2 75/63 37.0 33.8 49.4 3.90 9.5 80/67 39.5 35.2 51.9 3.89 10.1 85/71 42.2 36.5 54.7 3.88 10.9 75/63 37.7 34.2 49.7 3.77 10.0 80/67 40.3 35.5 52.3 3.76 10.7 85/71 43.1 36.9 55.2 3.74 11.5
Total
Capacity
(MBTUH)
Sensible Capacity
(MBTUH)
Heat of Rejection (MBTUH)
Power
Input (kW)
EER
Entering
Temp (F)
Water
Fluid
30*
40*
50
60
70
80
* Extended Range - Antifreeze required for entering fl uid
temperture at or below 45 Degrees F.
AHRI/ISO13256-1 certified per formance is rated at entering air conditions
of 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Tabulated unit performance does not include fan or pump power
corrections required for AHRI/ISO standard performance ratings.
Unit performance may be interpolated. Extrapolation is not allowed.
Ratings below 40°F are with a methanol solution.
Due to variations in installation, actual performance may vary from the
tabulated data. Performance contained herein are as a result of extensive testing by FHP and are not express warranties between the parties and may be changed at any time.
Continuous research and development to improve our products may result
in a change to the current design and specifications without notice.
Pressure
Flow
(GPM)
Drop
(FOH)
6 2.6 1.1
8 4.3 1.9
12 9.0 3.9
6 2.5 1.1
8 4.2 1.8
12 8.6 3.7
6 2.4 1.0
8 4.0 1.7
12 8.3 3.6
6 2.3 1.0
8 3.9 1.7
12 8.1 3.5
6 2.2 1.0
8 3.8 1.6
12 7.8 3.4
6 2.2 0.9
8 3.6 1.6
12 7.5 3.3
Engineering Submittal Sheet
Pressure
Drop
(PSI)
Entering
Air Temp
Total
Capacity
(F)
(MBTUH)
60 32.7 24.6 2.41 4.0
60 33.8 25.6 2.43 4.1
60 35.3 26.8 2.45 4.2
60 37.2 28.8 2.48 4.4
60 38.4 29.9 2.49 4.5
60 40.0 31.6 2.52 4.7
60 42.1 33.5 2.55 4.8
60 43.8 35.1 2.57 5.0
60 45.6 37.3 2.60 5.1
60 47.7 38.7 2.62 5.3
60 49.5 40.6 2.64 5.5
60 51.8 42.8 2.67 5.7
60 53.1 44.1 2.68 5.8
60 55.5 46.4 2.70 6.0
60 58.2 49.1 2.72 6.3
60 58.9 49.8 2.73 6.3
60 61.7 52.5 2.74 6.6
60 64.9 55.6 2.76 6.9
Heat of
Absorption
(MBTUH)
Power
Input
(kW)
COP
27 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 28
i Series Model BP
Residential Geothermal Heat Pumps
BP060 (2000 CFM) Capacity Data
Entering
Fluid
Temp (F)
50
60
70
80
85
90
100
110
Water
Pressure
Flow
Drop
(GPM)
(FOH)
7.5 2.8 1.2
10 4.8 2.1
15 9.9 4.3
7.5 2.7 1.2
10 4.6 2.0
15 9.6 4.2
7.5 2.7 1.2
10 4.5 1.9
15 9.2 4.0
7.5 2.6 1.1
10 4.3 1.9
15 8.9 3.9
7.5 2.5 1.1
10 4.2 1.8
15 8.8 3.8
7.5 2.5 1.1
10 4.2 1.8
15 8.7 3.8
7.5 2.4 1.0
10 4.1 1.8
15 8.4 3.6
7.5 2.3 1.0
10 3.9 1.7
15 8.2 3.5
Pressure
Drop (PSI)
COOLING HEATING
Entering Air Temp
(db/wb) F
75/63 64.4 50.2 74.5 3.07 20.9 80/67 68.9 51.7 79.2 3.11 22.2 70 43.6 31.9 3.47 3.7 85/71 73.0 53.5 83.5 3.14 23.3 80 43.2 30.2 3.82 3.3 75/63 65.9 50.5 75.6 2.95 22.3 80/67 70.2 52.5 80.1 2.97 23.6 70 45.1 33.3 3.50 3.8 85/71 74.7 54.3 84.7 3.00 24.9 80 44.5 31.5 3.85 3.4 75/63 67.2 51.4 76.6 2.83 23.8 80/67 71.8 53.1 81.3 2.85 25.2 70 46.8 34.9 3.52 3.9 85/71 76.6 54.8 86.2 2.86 26.8 80 46.1 33.0 3.87 3.5 75/63 61.9 49.0 72.9 3.34 18.5 80/67 66.0 50.8 77.1 3.37 19.6 70 49.1 37.2 3.56 4.0 85/71 70.2 52.6 81.4 3.40 20.7 80 48.9 35.6 3.92 3.7 75/63 63.0 49.6 73.6 3.21 19.7 80/67 67.3 51.3 77.9 3.23 20.9 70 51.5 39.1 3.59 4.2 85/71 71.7 53.4 82.5 3.25 22.1 80 50.6 37.2 3.95 3.8 75/63 64.3 50.0 74.5 3.08 20.9 80/67 68.8 51.8 79.1 3.09 22.3 70 53.5 41.3 3.63 4.3 85/71 73.5 53.7 83.8 3.10 23.7 80 52.6 38.9 3.99 3.9 75/63 59.2 47.6 71.1 3.65 16.2 80/67 62.5 49.5 74.5 3.67 17.0 70 56.0 43.6 3.66 4.5 85/71 63.1 51.1 75.1 3.66 17.3 80 55.2 41.4 4.03 4.0 75/63 60.3 48.4 71.8 3.50 17.2 80/67 64.5 50.1 76.1 3.52 18.3 70 58.4 46.1 3.70 4.6 85/71 68.3 52.8 79.9 3.53 19.3 80 57.3 43.5 4.07 4.1 75/63 61.6 48.9 72.7 3.37 18.3 80/67 66.0 50.5 77.2 3.38 19.6 70 61.0 48.2 3.74 4.8 85/71 70.4 52.6 81.6 3.38 20.8 80 59.8 45.8 4.11 4.3 75/63 53.4 46.4 66.3 3.97 13.5 80/67 55.0 47.6 67.9 3.97 13.9 70 62.9 50.2 3.77 4.9 85/71 66.4 52.4 79.9 4.09 16.3 80 62.0 47.9 4.15 4.4 75/63 58.3 48.4 71.0 3.87 15.1 80/67 62.8 50.7 75.6 3.89 16.1 70 65.7 52.9 3.81 5.0 85/71 61.1 50.4 73.7 3.84 15.9 80 64.6 50.3 4.19 4.5 75/63 58.6 47.5 70.7 3.70 15.9 80/67 62.8 49.2 75.0 3.71 16.9 70 69.2 55.6 3.86 5.2 85/71 68.8 53.0 81.8 3.91 17.6 80 67.6 53.0 4.25 4.7 75/63 53.1 44.0 66.7 4.17 12.7 80/67 54.8 47.5 68.4 4.18 13.1 70 70.2 57.4 3.89 5.3 85/71 64.7 52.1 78.8 4.28 15.1 80 69.2 54.7 4.28 4.7 75/63 51.9 45.8 64.8 4.00 13.0 80/67 61.2 50.1 74.6 4.08 15.0 70 73.1 60.0 3.93 5.4 85/71 66.2 52.4 79.8 4.12 16.1 80 72.2 57.5 4.33 4.9 75/63 55.9 44.3 68.6 3.89 14.4 80/67 59.4 46.9 72.1 3.88 15.3 70 77.6 63.6 4.00 5.7 85/71 66.9 52.3 80.4 4.08 16.4 80 75.7 60.7 4.39 5.1 75/63 51.7 43.3 65.9 4.38 11.8 80/67 55.6 44.2 70.0 4.41 12.6 70 78.0 64.6 4.01 5.7 85/71 62.8 51.0 77.6 4.48 14.0 80 76.6 61.9 4.41 5.1 75/63 52.7 43.9 66.5 4.23 12.5 80/67 56.5 45.5 70.4 4.24 13.3 70 81.9 68.5 4.07 5.9 85/71 64.3 51.9 78.5 4.31 14.9 80 80.2 65.1 4.47 5.3 75/63 53.8 44.3 67.1 4.08 13.2 80/67 55.8 47.9 69.1 4.06 13.7 70 85.5 70.9 4.13 6.1 85/71 65.1 51.5 79.2 4.27 15.3 80 84.1 68.8 4.55 5.4 75/63 49.0 41.2 64.7 4.84 10.1 80/67 52.0 43.2 67.9 4.86 10.7 85/71 51.8 47.3 67.6 4.86 10.7 75/63 48.2 44.3 63.3 4.66 10.3 80/67 52.0 45.8 67.3 4.68 11.1 85/71 60.4 50.4 76.1 4.76 12.7 75/63 50.1 43.6 64.8 4.52 11.1 80/67 53.0 46.6 67.7 4.51 11.7 85/71 54.4 48.1 69.1 4.50 12.1 75/63 44.8 41.4 62.1 5.36 8.4 80/67 47.1 44.2 64.5 5.38 8.8 85/71 48.7 46.2 66.3 5.39 9.0 75/63 44.7 42.9 61.5 5.19 8.6 80/67 48.4 44.4 65.3 5.21 9.3 85/71 56.8 49.1 74.1 5.28 10.8 75/63 49.3 44.7 66.1 5.16 9.6 80/67 49.9 44.1 66.3 5.04 9.9 85/71 57.7 49.4 74.7 5.17 11.2
Total
Capacity
(MBTUH)
Sensible Capacity
(MBTUH)
Heat of Rejection (MBTUH)
Power
Input (kW)
EER
Entering
Temp (F)
Water
Fluid
30*
40*
50
60
70
80
* Extended Range - Antifreeze required for entering fl uid
temperture at or below 45 Degrees F.
AHRI/ISO13256-1 certified per formance is rated at entering air conditions
of 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Tabulated unit performance does not include fan or pump power
corrections required for AHRI/ISO standard performance ratings.
Unit performance may be interpolated. Extrapolation is not allowed.
Ratings below 40°F are with a methanol solution.
Due to variations in installation, actual performance may vary from the
tabulated data. Performance contained herein are as a result of extensive testing by FHP and are not express warranties between the parties and may be changed at any time.
Continuous research and development to improve our products may result
in a change to the current design and specifications without notice.
Pressure
Flow
(GPM)
Drop
(FOH)
7.5 3.8 1.7
10 6.4 2.8
15 13.4 5.8
7.5 3.7 1.6
10 6.2 2.7
15 12.9 5.6
7.5 3.6 1.5
10 6.0 2.6
15 12.5 5.4
7.5 3.5 1.5
10 5.8 2.5
15 12.0 5.2
7.5 3.3 1.4
10 5.6 2.4
15 11.7 5.0
7.5 3.2 1.4
10 5.4 2.4
15 11.3 4.9
Engineering Submittal Sheet
Pressure
Drop
(PSI)
Entering
Air Temp
Total
Capacity
(F)
(MBTUH)
60 44.2 33.8 3.16 4.1
60 46.0 35.0 3.18 4.2
60 47.6 36.8 3.21 4.3
60 49.8 39.0 3.24 4.5
60 52.4 41.1 3.27 4.7
60 54.5 43.0 3.30 4.8
60 56.8 45.6 3.34 5.0
60 58.9 47.6 3.37 5.1
60 62.5 50.6 3.41 5.4
60 64.0 52.4 3.43 5.5
60 67.0 55.3 3.48 5.6
60 70.7 58.5 3.52 5.9
60 71.5 59.8 3.54 5.9
60 74.7 62.8 3.59 6.1
60 79.4 66.8 3.65 6.4
60 79.5 67.3 3.65 6.4
60 83.7 71.5 3.71 6.6
60 87.8 74.2 3.77 6.8
Heat of
Absorption
(MBTUH)
Power
Input
(kW)
COP
28 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 29
i Series Model BP
Residential Geothermal Heat Pumps
Antifreeze Correction
Antifreeze Type Antifreeze %
Total Cap. Sens. Cap Power Htg. Cap Power
Water 0 1.000 1.000 1.000 1.000 1.000 1.000
5 0.997 0.997 1.004 0.989 0.997 1.06
10 0.994 0.994 1.006 0.986 0.995 1.125
Propylene Glycol
Methanol
Ethanol
15 0.990 0.990 1.009 0.978 0.988 1.19
25 0.983 0.983 1.016 0.960 0.979 1.3
5 0.997 0.997 1.003 0.990 0.997 1.06
10 0.996 0.996 1.005 0.979 0.993 1.1
15 0.994 0.994 1.008 0.970 0.990 1.14
5 0.998 0.998 1.002 0.981 0.994 1.16
10 0.996 0.996 1.004 0.960 0.988 1.23
15 0.992 0.992 1.006 0.944 0.983 1.280
25 0.986 0.986 1.009 0.917 0.974 1.4
EWT 90 Deg.F EWT 30 Deg. F
Engineering Submittal Sheet
Cooling Heating
WPD Correction
Factor EWT 30 °F
Ethylene Glycol
5 0.997 0.997 1.003 0.993 0.998 1.06
10 0.995 0.995 1.004 0.986 0.996 1.12
15 0.992 0.992 1.005 0.980 0.993 1.19
25 0.988 0.988 1.009 0.970 0.990 1.33
30 0.985 0.985 1.012 0.965 0.987 1.4
29 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 30
i Series Model BP
Residential Geothermal Heat Pumps
Casing Radiated Sound Power - Octave Band Sound Power Levels dB, re 10-12 Watts
Model Load
Cooling Full 64 48 43 42 38 32 27 64 50
BP007
BP009
BP012
BP015
BP018
BP024
BP030
BP036
BP042
BP048
BP060
Heating Full 63 58 44 44 40 34 28 64 53
FAN Only 5443424237312455 46*
Cooling Full 61 50 46 51 45 40 34 62 54
Heating Full 62 53 46 51 45 40 34 63 54
FAN Only 5548475145403258 53
Cooling Full 66 58 51 51 45 41 35 67 56
Heating Full 71 61 51 51 45 40 34 71 59
FAN Only 6156515145393363 55
Cooling Full 59 51 51 46 42 34 32 60 52
Heating Full 63 56 57 55 51 45 40 66 59
FAN Only 5146463833252345 45
Cooling Full 71 62 53 49 47 45 41 72 59
Heating Full 76 66 59 56 55 52 47 77 65
FAN Only 5048494235302454 48
Cooling Full 63 55 54 49 42 37 28 65 55
Heating Full 71 56 54 50 44 41 32 72 58
FAN Only 5552534942382759 54
Cooling Full 67 58 56 52 45 38 28 68 58
Heating Full 67 58 66 52 46 39 30 68 58
FAN Only 5855565245382662 56
Cooling Full 65 62 62 63 58 52 43 70 66
Heating Full 67 63 63 64 59 52 44 71 67
FAN Only 6562626358524370 66
Cooling Full 71 58 57 55 46 46 39 71 60
Heating Full 73 58 57 55 47 47 39 73 61
FAN Only 5655575546463762 59
Cooling Full 72 63 58 57 51 43 38 73 62
Heating Full 73 63 58 57 52 44 37 74 62
FAN Only 6061575751433466 60
Cooling Full 63 61 59 57 53 48 39 67 61
Heating Full 64 61 58 58 53 49 40 67 62
FAN Only 5960585753483965 61
125 250 500 1000 2000 4000 8000 Overall
Center Frequency - Hz
Engineering Submittal Sheet
Overall (dBA)
Tested according to AHRI-260 standard for ISO-13256
WLHP condition at rated water and air fl ow rate
Overall calculated using 125-8000 Hz octave bands.
30 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 31
i Series Model BP
Residential Geothermal Heat Pumps
Ducted Discharge Sound Power - Octave Band Sound Power Levels dB, re 10-12 Watts
Model Load
Cooling Full 60 47 51 57 51 45 37 63 59
BP007
BP009
BP012
BP015
BP018
BP024
BP030
BP036
BP042
BP048
BP060
Heating Full 61 50 51 53 47 46 39 63 56
FAN Only 5850515647463961 58
Cooling Full 62 52 53 55 50 51 47 64 59
Heating Full 63 53 54 56 50 50 47 65 60
FAN Only 6353545549514765 59
Cooling Full 71 61 58 56 51 51 48 72 62
Heating Full 71 62 59 58 50 51 48 72 63
FAN Only 7161617059514874 71
Cooling Full 66 50 56 53 47 46 37 67 58
Heating Full 68 53 57 58 48 46 38 69 61
FAN Only 6149575748463764 60
Cooling Full 69 52 59 57 50 48 39 70 61
Heating Full 70 53 60 57 49 48 39 71 62
FAN Only 6251595849483965 61
Cooling Full 70 55 63 52 51 54 43 71 62
Heating Full 73 56 63 54 50 53 42 74 63
FAN Only 6655635250534368 62
Cooling Full 70 55 63 52 51 54 43 71 62
Heating Full 73 56 63 54 50 53 42 74 63
FAN Only 6655635250534368 62
Cooling Full 78 64 71 60 59 62 55 79 71
Heating Full 79 67 71 61 58 61 55 80 71
FAN Only 7966716058615580 71
Cooling Full 73 58 66 57 56 56 50 74 66
Heating Full 75 59 66 56 56 56 49 76 66
FAN Only 7359665756564974 66
Cooling Full 75 62 66 59 58 61 53 76 68
Heating Full 75 62 66 58 56 60 52 76 67
FAN Only 7663665957605377 68
Cooling Full 78 65 66 60 57 60 54 79 69
Heating Full 76 64 67 60 54 59 52 77 68
FAN Only 7765666055605377 68
125 250 500 1000 2000 4000 8000 Overall
Center Frequency - Hz
Engineering Submittal Sheet
Overall (dBA)
Tested according to AHRI-260 standard for ISO-13256
WLHP condition at rated water and air fl ow rate
Overall calculated using 125-8000 Hz octave bands.
31 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 32
Engineering Submittal Sheet
i Series Model BP
Residential Geothermal Heat Pumps
WARNING:
These electric heaters can only be installed in factory default blower confi guration only.
Field Installed Accessory - Duct Mounted Electric Heaters 208/230V
Kilowatt Heater - 208/230V Part Number
Duct Heater 5 kW 7738000004 14 x 14 13.75 x 13.75 600
Duct Heater 5 kW 7738000005 14 x 16 13.75 x 13.75 600
Duct Heater 5 kW 7738000006 16 x 16 15.75 x 15.75 600
Duct Heater 5 kW 7738000007 18 x 18 17.75 x 17.75 600
Duct Heater 10 kW 7738000008 14 x 16 13.75 x 13.75 800
Duct Heater 10 kW 7738000009 16 x 16 17.75 x 17.75 800
Duct Heater 10 kW 7738000010 18 x 18 17.75 x 17.75 800
Duct Heater 15 kW 7738000011 18 x 18 17.75 x 17.75 1400
Duct Heater 20 kW 7738000012
Nominal Dimensions
(inches)
18 x 18 17.75 x 17.75 2000
Duct Flange Connection
(Inches)
Min. CFM
Required
It is recommended to use a seven (7) conductor
cable for thermostat interface.
It is required for the duct mounted heater to have
an independent power supply.
In fi ber glass duct systems, a metal sleeve MUST be
used to insert the support the heater.
Field Installed Option - Swivel Connector Kit (two connectors per package)
BP007 BP009 BP012 BP015 BP018 BP024 BP030 BP036 BP042 BP048 BP060
Order
Number
7738003200
7738003201
Type
VT HZ CF VT HZ CF VT HZ CF VT HZ CF V T HZ CF VT HZ CF VT HZ CF V T HZ CF VT HZ CF VT HZ CF VT HZ CF
&
Size
Male

3/4" NPT
Male
1"
NPT
Where Used

32 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 33
i Series Model BP
Residential Geothermal Heat Pumps
Field Installed Option - Communicating Thermostats
Engineering Submittal Sheet
Model/Order Number: 7738002994 7738002993
Description: TSTBT4H2CPHM - KA TSTBT4H2CP - M - KA
Features:
Application:
Warranty: 5 Year Limited Warranty
4 stages of heat, 2nd stage latching, Low temp alert,
High temp alert, Ineffi cient heating and cooling
Communicating
Thermostat Kit w/
Humidity Control
operation alerts
Communicating
Thermostat Kit
Communicating Thermostat Accessories
Model/Order Number: 7738002978 7738002979
Description: ZONB - OTS - - - M - - A ZONB - LAS - - - M - - A
Features:
Wired Outdoor
Temperature Sensor
Leaving Air and/or Return
Air Sensor
Field Installed Option - 24V Conventional Thermostat
Field Installed Option - Bosch Humidifi ers
HUMBSBP-12H6--A HUMBSBP-17H6--A
Model/Order Number: 7738002984
Description: TSTBM3H2CPH6W - A
Features:
Application:
Warranty: 5 Year Limited Warranty
24V Conventional Thermostat Accessories
24V Conventional Thermostat Accessories
Model/Order Number: 7738002985 7738002986
Description: TSTBM - RRS - - TW - A TSTBM - OTS - - TW - A
Features:
Smoke detection, Semi-wireless, Filter change/clean notifi cation, Programmable fan
If smoke is detected in ducting, unit will stop, pre­venting circulation of smoke to other rooms.
Wireless Remote Room
Sensor Thermostat
Model/Order Number: 7738002895 7738002896
Description: HUMBXSBP12H6 - - A HUMBXLBP17H6 - - A
Small Bypass
Features:
Application: 12 Gallons per Day 17 Gallons per Day
Warranty:
Humidifi er, Manual Summer/Winter Damper, Humidistat included
1 Year Limited Warranty on Humidifer Pad
Wireless Outdoor
Temperature Sensor
Large Bypass Humidifi er, Manual Summer/Winter Damper, Humidistat Included
5 Year Limited Warranty on Assembly
33 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us
Page 34
i Series Model BP
Residential Geothermal Heat Pumps
Field Installed Option - Bosch Photo Catalytic Oxidizer (PCO)
Field Installed Option - Bosch Fresh Air Damper (FAD)
Model/Order Number: 7738002927 7738002928 7738002929
Description: FADB - 04007 - 6 - - A FADB - 050011 - 6 - - A FADB - 060015 - 6 - - A
Size 4" Fresh Air Damper 5" Fresh Air Damper 6" Fresh Air Damper
Engineering Submittal Sheet
Model/Order Number: 7738002879 7738002880
Description: PCOB - 09012 - 0 - - A PCOB - 14024 - 0 - - A
Features: 9" UVC Light Bulb 14" UVC Light Bulb
Application:
Warranty:
up to 1500 CFM units
or House up to 2000
sq. ft.
1 Year Limited Warranty on Bulb
2 Year Limited Warranty on Ballast
5 Year Limited Warranty on Assembly
up to 2400 CFM units
or House up to 4700
sq. ft.
Field Installed Option - Smoke Detector
— Variable Capacity Control (settings from 0 to 100 of available CFM)
Features:
Application:
Warranty: 5 Year Limited Warranty on Assembly
Model/Order Number: 7738002987 7738002988
Description: SMKB - - - 040 - 6 - - A SMKB - 02FST - 6 - - A
Features: Duct Smoke Detector 2 Foot Air Sampling Tube
Application:
Warranty: 5 Year Limited Warranty on Par ts
— Variable Position Damper — Included Variable Position Control Included — Vent Hood with Screen Included
A minimum of 70
CFM of fresh air
from outside up to
1300 sq. ft. home
If smoke is detected in ducting, unit will stop, preventing circulation of smoke to other rooms. Manual reset is required which let's customer know there was an occurrence.
A minimum of 110 CFM of fresh air from outside up to 2100 sq. ft. home
A minimum of 150 CFM of fresh air from outside up to 3000 sq. ft. home
34 of 34
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 A | 01.2014
Bosch Thermotechnology Corporation
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.bosch-climate.us