Bosch BP User Manual

Page 1
i series
Engineering
Model BP Residential Geothermal Heat Pumps
Overview and Certifi cations
Submittal
Sheet
®
Standard Features, Factory Installed Options, and Field Installed Accessories
Standard Features
Available in Horizontal and Vertical Cabinets
Constructed using white pre-painted steel — Hanging brackets standard for horizontal cabinet
High Efficiency
Up to 21.2 EER @ FL GLHP — Compliant with Energy Start Tier 3 — PSC blower motor for unit size 012 — Constant Torque ECM for unit sizes 018-048
Configured as Ordered
Left hand or right hand return air — Top or end supply air
½" Dual Density Fiber Insulation
non-combustible, non-hydroscopic and does not
support fungal growth — meets NFPA 90A and 90B for fire protection — meets the GREENGUARD Indoor Air Quality
Standard
Compressors
Floating compressor base pan for quite operation — 012 - 018 Rotary — 024 - 048 Scroll
Standard MERV 8 Filter with 4 sided Filter Rack
TXV (Thermal Expansion Valve)
Improves refrigerant management and efficiencies
Reliability - Durability - Serviceability
UPM circuit board with communicating features — Completely serviceable from front of unit
DuoGuard(™) Evaporator Coil
Tin electro-plated copper tubing with high-
tech polymer coated aluminum fins will protect the evaporator coil from all forms of corrosive elements in the airstream
1 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 2
i Series Model BP
Residential Geothermal Heat Pumps
Standard Features, Factory Installed Options, and Field Installed Accessories continued..
Engineering Submittal Sheet
Electronic Circuit Board UPM
The electronic circuit board provides protection with:
Random Start of Unit — 5 minute short cycle time delay (Anti-Short Cycling) — Alarm communicating Output — Low pressure switch bypass at cold water start up
It also monitors and communicates standard safety features/ alerts/operation/protection:
Low Pressure Switch — High Pressure Switch — Evaporator Freeze Switch — Water Coil Freeze Switch — Condenstate Overflow Switch
This circuit board can communicate with a Bosch thermostat that alerts the customer of adverse conditions.
Standard 75 VA Transformer
Standard Warranty
10 year all parts limited warranty — 10 year labor limited warranty — For full warranty details: https://www.bosch-
climate.us/support-center/product-warranty-library/ residential-heat-pumps-geothermal-warranty­documents.html
Field Configurable Horizontal Discharge Air Conversion
The horizontal conversion allows end blow to straight
through conversion of discharge air, as the straight through confi guration for horizontal is no longer available.
Field Installed Accessories
Thermostats
Bosch thermostats are fully customized to meet
your individual needs. Bosch offers communicating thermostats that can display alert messages without having to go to the unit.
Externally Mounted Duct Heater Kits
Swivel Water Connections
3/4" or 1" FPT Swivel Water Connection
Internally Mounted Electric Heater Kits
A field installed option for back up heat. Available
in 5, 10, 15, or 20 kW depending on the size of the geothermal heat pump.
Pump/Valve Relay Kit
This relay is used to energize a supply pump or
solenoid valve when there is a call for compressor operation. This relay can be used to switch either high or low voltage power.
SmartStart Assist Kit
An option which provides a means of reducing
inrush currents at compressor startup. Light flickering is eliminated, and a smooth start is achieved (only available on scroll compressor models).
Stainless Steel Hose Kits
Available in various lengths and diameters
depending on the need for your application.
2 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Flow Center Kits
Bosch Thermotechnology Corp.
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 3
i Series Model BP
Residential Geothermal Heat Pumps
Model Nomenclature
BP 048- 1 VT C -F L T
SERIES:
BP
NOMINAL CAPACITY: SUPPLY AIR LOCATION
VOLTAGE DESIGNATION:
1 - 208-230/1/60
Engineering Submittal Sheet
VT UNITS:
T - TOP
HZ UNITS:
E - END DISCHARGE
CABINET CONFIGURATION:
VT - VERTICAL HZ - HORIZONTAL
RETURN AIR LOCATION:
L - LEFT R - RIGHT
HEAT EXCHANGER MATERIAL:
C - COPPER N - CUPRO-NICKEL
ASHRAE/AHRI/ISO 13256-1. with PSC Motor
Model
Number
BP012 4.0 400 12200 14.90 16500 5.10 14600 22.70 13000 4.30 13000 17.50 10000 3.60
Fluid Flow
Rate
(GPM)
Air Flow Rate
(CFM)
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling
Capacity
(Btu/hr)
EER
Heating
Capacity
(Btu/hr)
COP
Cooling
Capacity
(Btu/hr)
EER
Heating
Capacity
(Btu/hr)
WATER CONNECTIONS LOCATIONS:
F - FRONT
Cooling
COP
Capacity
(Btu/hr)
EER
Heating
Capacity
(Btu/hr)
ASHRAE/AHRI/ISO 13256-1. with ECM Motor (Const Torque)
Model
Number
BP018 5.0 600 19500 16.40 21300 5.30 21300 25.60 17700 4.50 20500 19.00 14800 3.80 BP024 6.0 850 24500 16.95 28500 5.35 28400 27.35 23700 4.50 26000 19.80 18000 3.70 BP030 7.0 1000 27000 16.60 31000 5.90 31700 27.00 25000 5.20 28500 19.40 20500 4.30 BP036 10.0 1200 36000 17.20 41000 5.60 40200 25.90 34400 4.90 37500 19.70 26000 4.10 BP042 10.5 1400 40600 18.20 42400 6.00 45000 25.70 35000 5.10 42200 21.10 26800 4.10 BP048 12.0 1600 47400 17.20 50000 5.30 52900 26.10 40500 4.30 49500 20.00 33400 3.70
Fluid Flow
Rate
(GPM)
Air Flow Rate
(CFM)
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling
Capacity
(Btu/hr)
EER
Heating
Capacity
(Btu/hr)
COP
Cooling
Capacity
(Btu/hr)
EER
Heating
Capacity
(Btu/hr)
COP
Cooling
Capacity
(Btu/hr)
EER
Heating
Capacity
(Btu/hr)
COP
COP
3 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 4
Engineering Submittal Sheet
i Series Model BP
Residential Geothermal Heat Pumps
Physical Data
Description Unit
Compressor Type — Max Water Working Pressure PSIG/kPa
Standard Fan Motor & Blower
Fan Motor Type/Speeds
Fan Motor (HP) HP 1/10 1/3 1/3 1/2 3/4 3/4 3/4 Blower Wheel Size (Dia. x W) Inch
Water Connection Size
FPT Inch Coaxial Coil Volume gal
Vertical Cabinet
Refrigeration Charge oz Air Coil Dimensions (H x L) Inch 16x16.5 16.5x20 24x21 24x27 24x27 32x27 32x27
Standard Filter - 2" MERV 8 (H x L)
Weight - Operating Lbs 166 195 229 269 281 334 340 Weight - Shipping Lbs
Horizontal Cabinet
Refrigeration Charge oz Air Coil Dimensions (H x L) Inch 16x16.5 18x18.5 18x28 20x32.5 20x32.5 20x43.25 20x43.25
Standard Filter - 2" MERV 8 (H x L)
Weight - Operating Lbs 173 198 307 358 369 400 405 Weight - Shipping Lbs
Inch 18x20 20x20 24x24 24x30 24x30 16x30 (2) 16x30 (2)
Inch 18x20 18x20 20x30 20x34.5 20x34.5 20x24 (2) 20x24 (2)
012 018 024 030 036 042 048
Rotary Rotary Scroll Scroll Scroll Scroll Scroll
400/3100 400/3100 400/3100 400/3100 400/3100 400/3100 400/3100
PSC/3
5.5x5.5 9x7 9x7 9x7 9x7 10x8 10x8
3/4 3/4 3/4 1 1 1 1
0.31 0.31 0.48 0.39 0.62 0.62 0.62
46 35 65 71 68 83 86
186 212 242 292 304 360 366
46 35 65 71 71 80 82
205 222 340 404 415 465 470
ECM Const
Torque / 3
speed
ECM Const
Torque / 3
speed
Model Size
ECM Const
Torque / 3
speed
ECM Const
Torque / 3
speed
ECM Const
Torque / 3
speed
ECM Const
Torque / 3
speed
4 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 5
Engineering Submittal Sheet
i Series Model BP
Residential Geothermal Heat Pumps
Horizontal Cabinet Corner Weights
Confi guration Left Hand Evaporator Right Hand Evaporator
Model Unit Total Left Front* Right Front* Left Back Right Back Left Front* Right Front* Left Back Right Back
BPH 012
BPH 018
BPH 024
BPH 030
BPH 036
BPH 042
BPH 048
*Front is control box end
Lbs 173 46 42 45 40 44 44 40 45
kg 79 21 19 21 18 20 20 18 21
Lbs 198 51 49 50 48 49 51 47 51
kg 90 23 22 23 22 22 23 22 23
Lbs 307 80 78 79 70 77 81 68 81
kg 140 36 36 36 32 35 37 31 37
Lbs 358 99 88 92 79 96 92 78 92
kg 163 45 40 42 36 44 42 35 42
Lbs 369 100 92 94 83 96 96 81 96
kg 168 45 42 43 38 44 44 36 44
Lbs 400 107 99 105 89 103 103 88 106
kg 182 49 45 48 40 47 47 40 48
Lbs 405 106 108 102 89 102 112 85 106
kg
184 48 49 46 41 46 51 39 48
Factory Installed Option - Cupro-Nickel Coil
Model Number with Standard Copper Coil
BP012-1HZC BP012-1HZN BP012-1VTC BP012-1VTN BP018-1HZC BP018-1HZN BP018-1VTC BP018-1VTN BP024-1HZC BP024-1HZN BP024-1VTC BP024-1VTN BP036-1HZC BP036-1HZN BP036-1VTC BP036-1VTN BP048-1HZC BP048-1HZN BP048-1VTC BP048-1VTN
* dashes are included as a digit.
(To add this option to the product, change the model number 10TH digit* to an “N”)
Model Number with Cupro-Nickel Coil
5 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 6
Engineering Submittal Sheet
i Series Model BP
Residential Geothermal Heat Pumps
Electrical Data - Standard Motor - PSC for 012
Model
BP012 -1 208-230/60/1 1 4.6 27.9 1 0.96 0.1 6.7 15
Electrical Data - Standard Motor - Constant Torque for 018-048
Model
BP018 -1 208-230/60/1 1 7.4 33 1 2.8 0.33 12.1 15 BP024 -1 208-230/60/1 1 13.5 58.3 1 2.8 0.33 19.7 30 BP030 -1 208-230/60/1 1 12.8 58.3 1 4.1 0.5 20.1 30 BP036 -1 208-230/60/1 1 16 77 1 6 0.75 26.0 40 BP042 -1 208-230/60/1 1 16.7 79 1 6 0.75 26.9 40 BP048 -1 208-230/60/1 1 19.9 109 1 6 0.75 30.9 50
Electrical
Symbol
Electrical
Symbol
Voltage/Hz/Phase
Voltage/Hz/Phase
Compressor Blower Motor
QTY RLA LRA QTY FLA HP
Compressor Blower Motor
QTY RLA LRA QTY FLA HP
Min Circuit
Amps
Min Circuit
Amps
Max Fuse/
HACR
Max Fuse/
HACR
208/230V Units shipped with transformer wired for
230V—for 208V remove orange tranformer primary lead and replace with red lead.
Electrical Data - Field Install Internal Electric Heat Accessory - Compressor Power Connection
Models Voltage Code Voltage/Hz/Phase
BP018 1 208-230/60/1 197/253 1 7.4 33.0 9.3 15 BP024 1 208-230/60/1 197/253 1 13.5 58.3 16.9 30 BP030 1 208-230/60/1 197/253 1 12.8 58.3 26.5 25 BP036 1 208-230/60/1 197/253 1 16.0 77.0 20.0 30 BP042 1 208-230/60/1 197/253 1 16.7 79.0 20.9 30 BP048 1 208-230/60/1 197/253 1 19.9 109.0 24.9 40
Voltage Min/
Max
QTY RLA LRA
Compressor
Min Circuit
Amps
Max Fuse/
HACR
6 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 7
Engineering Submittal Sheet
i Series Model BP
Residential Geothermal Heat Pumps
Electrical Data - Electric Heat Option Constant Torque ECM
Model
BP018 4.8 1 4,800 3,600 20.0 17.3 2.8 - 28.5 25.1 30 30
BP024 4.8 1 4,800 3,600 20.0 17.3 2.8 - 28.5 25.1 30 30
BP024 9.6 1 9,600 7,200 40.0 34.6 2.8 - 53.5 46.8 60 50
BP030 4.8 1 4,800 3,600 20.0 17.3 4.1 - 30.1 26.8 35 30
BP030 9.6 1 9,600 7,200 40.0 34.6 4.1 - 55.1 48.4 60 50
BP036 4.8 1 4,800 3,600 20.0 17.3 6.0 - 32.5 29.1 35 30
BP036 9.6 1 9,600 7,200 40.0 34.6 6.0 - 57.5 50.8 60 60
BP036 14.4 2 14400 10800 60 51.9 6
BP042 4.8 1 4,800 3,600 20.0 17.3 6.0 - 32.5 29.1 35 30
BP042 9.6 1 9,600 7,200 40.0 34.6 6.0 - 57.5 50.8 60 60
BP042 14.4 2 14400 10800 60 51.9 6
BP048 4.8 1 4,800 3,600 20.0 17.3 6.0 - 32.5 29.1 35 30
BP048 9.6 1 9,600 7,200 40.0 34.6 6.0 - 57.5 50.8 60 60
BP048 14.4 2 14400 10800 60 51.9 6
BP048 19.2 2 19200 14000 80 69.2 6
EH RATED
kW
STAGE
Heater Watts Heater AMPS Circuit MCA MOP
240 208 240V 208V
Motor FLA
(A)
Fuses 240V 208V 240V 208V
F1/F2 F3/F4
F1/F2 F3/F4
F1/F2 F3/F4 F1/F2 F3/F4
82.5 72.4 90 80
82.5 72.4 90 80
82.5 72.4 90 80
107.5 94.0 110 100
7 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 8
Engineering Submittal Sheet
i Series Model BP
Residential Geothermal Heat Pumps
Operating Limits - Cooling & Heating
Description Standard Unit
COOLING
Minimum ambient air temperature °F 50 Maximum ambient air temperature °F 100 Minimum evaporator entering air db/wb °F 68/57 Rated air coil entering air db/wb °F 80/67 Maximum evaporator entering air db/wb °F 95/85 Minimum water coil entering fl uid temperature °F 50 Water loop typical coil entering fl uid range temperature °F 70/90
Maximum water coil entering fl uid temperature °F 110
HEATING
Minimum ambient air temperature °F 40
Maximum ambient air temperature °F 85
Minimum evaporator entering air db °F 50
Rated air coil entering air °F 68
Maximum evaporator entering air db °F 80
Normal water coil entering fl uid range °F 25-80*
Minimum water coil entering Fluid °F 20*
* Antifreeze solution is required for fl uid temperature at or below 45 Degrees F.
8 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 9
i Series Model BP
Residential Geothermal Heat Pumps
Blower Performance CFM Standard Motor - PSC for 012
Available External Static Pressure (in. wc. Wet coil and fi lter included)
Model
BP012
Blower Performance CFM Standard Motor - Constant Torque ECM for 018-048
Model
BP018
BP024
BP030
BP036
BP042
BP048
Motor Speed
Low450435415400385360330305----
Medium 425 405 385 375 360 335 310 -----
High 390 380 365 350 335 315 290 -----
Motor Speed
Low730700660615580545505460----
Medium 615 575 540 500 460 420 ------
High 540 510 480 445 405 360 -----­Low975945910880855825790750----
Medium 905 885 855 825 790 755 700 650 ----
High 725 700 670 640 585 530 -----­Low 1225 1195 1170 1140 1110 1075 1010 940 745 - - -
Medium 1110 1075 1045 1015 985 955 915 880 700 - - -
High 955 925 890 860 825 790 750 715 685 - - ­Low 1440 1420 1400 1380 1345 1315 1240 1165 1005 845 - -
Medium 1340 1315 1290 1270 1245 1225 1180 1135 990 845 - -
High 1190 1165 1140 1115 1090 1065 1040 1020 915 810 - ­Low 1645 1635 1610 1585 1560 1535 1510 1485 1460 1430 - -
Medium 1455 1425 1400 1375 1345 1320 1290 1260 1225 1190 - -
High 1220 1190 1160 1130 1100 1070 1015 955 895 830 - ­Low 1840 1820 1795 1775 1745 1720 1695 1670 1645 1615 - -
Medium 1655 1635 1610 1585 1560 1535 1510 1485 1460 1430 - -
High 1455 1425 1400 1375 1345 1320 1290 1260 1225 1190 - -
0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20
Available External Static Pressure (in. wc. Wet coil and fi lter included)
0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20
Engineering Submittal Sheet
9 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 10
i Series Model BP
Residential Geothermal Heat Pumps
Vertical Unit Confi guration
Engineering Submittal Sheet
Access Panel
Water Out
Condensate Drain
Water In
FRONT–FRT
Right Hand Return
Top Discharge FRT
Horizontal Unit Confi guration
ont Fr
High Voltage
Access Panel
Electrical Knockouts 4 Places
Low Voltage
Straight Through FRS
End FRE
Left Hand Return
Top Discharge FLT
Straight Through FLS
End FLE
Access Panel
Water Out
Condensate Drain
Water In
FRONT–FLT
Access Panel
High Voltage
Electrical Knockouts 4 Places
Low Voltage
ont Fr
Return Air Right
10 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Return Air Left
Bosch Thermotechnology Corp.
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 11
i Series Model BP
Residential Geothermal Heat Pumps
BP-Vertical Dimensions and Connections
Engineering Submittal Sheet
E
F
G
C
B
D
Access
Panel
Condenser
Water Out
Condensate
Drain
Condenser
K
J
A
Water In
Electrical
Knock-outs
A
E
D
F
Q
M
P
C
N
B
H
Left Hand Return (FLT) Right Hand Return (FRT) Return Air (Filter) View
BP-Vertical Dimensions and Connections
ABCDEFGHJKMNPQ
Model
BP012 21.75 21.75 32.75 11.75 7.75 5.00 8.50 2.62 7.50 12.50 18.00 16.00 18.00 8.50 3/4" FPT 18 x 20 x 2
BP018 21.75 21.75 39.25 13.75 13.75 4.00 6.12 2.25 7.50 12.25 18.00 18.00 20.00 4.00 3/4" FPT 20 x 20 x 2
BP024 21.75 26.25 47.25 13.75 15.75 6.25 4.87 2.50 8.75 15.00 22.00 22.00 24.00 4.00 3/4" FPT 24 x 24 x 2
BP030 24.25 33.50 47.25 15.75 15.75 8.87 7.00 2.50 8.50 14.50 28.00 22.00 24.00 4.00 1" FPT 24 x 30 x 2
BP036 24.25 33.50 47.25 15.75 15.75 8.87 7.00 2.50 8.50 14.50 28.00 22.00 24.00 4.00 1" FPT 24 x 30 x 2
BP042 26.25 33.50 58.25 17.75 17.75 7.87 6.75 3.25 8.50 13.25 28.00 30.00 32.00 4.00 1" FPT 16 x 30 x 2 (2)
BP048 26.25 33.50 58.25 17.75 17.75 7.87 6.75 3.25 8.50 13.25 28.00 30.00 32.00 4.00 1" FPT 16 x 30 x 2 (2)
Width Depth Height
Dis-
charge
Depth
Dis-
charge
Width
Cabinet Edge to
Dis-
charge
Left
Side to
Dis-
charge
Water In
Bottom to Con-
densate
Drain
Water
Out
R/A
Duct
Width
R/A
Duct Flange Height
Filter
Rack
Height
Right
Side to
Dis-
charge
Condenser
Water
Connections
Recommended
Replacement Normal Filter
Size
All dimensions within +/– 0.125". Specifi cations
subject to change without notice.
11 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 12
i Series Model BP
Residential Geothermal Heat Pumps
BP-Horizontal Dimensions and Connections
Engineering Submittal Sheet
D
E
Access
Panel
C
F
Electrical
Knock-outs
H
B
Return Air
Opening
M
K
J
N
Condensate
Drain
A
G
Left Hand Return Left Hand Return
End Blow (FLE)
Return Air
Opening
Q
N
A
C
K
J
B
Condenser
Water In
Condenser
Water Out
Access
Panel
D
E
F
Condensate Drain
Right Hand Return Right Hand Return End Blow (FRE)
BP- Horizontal Dimensions and Connections
ABCDEFGHJKMNPQRT
Model
Width Depth Height
BP012 22.25 45.25 19.75 0.62 20.25 24.25 2.50 12.50 3.62 11.75 7.12 7.75 3.62 4.75 18.00 16.00 3/4" FPT 18 x 20 x 2
BP018 22.25 45.25 19.75 1.62 20.25 23.25 2.50 12.50 2.75 13.75 3.12 13.75 2.75 2.87 18.00 16.00 3/4" FPT 18 x 20 x 2
BP024 26.25 54.75 22.00* 1.25 30.25 23.00 2.62 15.12 3.75 13.75 2.12 15.75 3.75 4.25 20.12 18.00 3/4" FPT 20 x 30 x 2
BP030 30.25 68.25 22.00* 2.00 35.00 31.25 2.50 13.25 4.50 15.75 4.00 15.75 4.50 2.25 20.12 18.00 1" FPT 20 x 34.5 x 2
BP036 30.25 68.25 22.00* 2.00 35.00 31.25 2.50 13.25 4.50 15.75 4.00 15.75 4.50 2.25 20.12 18.00 1" FPT 20 x 34.5 x 2
BP042 30.25 79.00 22.00* 0.75 48.25 29.62 2.75 13.25 4.50 17.75 2.25 17.75 4.50 2.12 20.12 18.00 1" FPT 20 x 24 x 2 (2)
BP048 30.25 79.00 22.00* 0.75 48.25 29.62 2.75 13.25 4.50 17.75 2.25 17.75 4.50 2.12 20.12 18.00 1" FPT 20 x 24 x 2 (2)
Cab
End to
Filter Rack
"R/A Duct
Width"
Cab
Front
to Filter
Rack
Water InWater
Out
Side to
Dis-
charge
Dis-
charge
Width
Top to
Dis­charge (FLE &
FRS)
Dis­charge Height
End to
Dis-
charge
Top to
Dis-
charge
(FRE &
FLS)
Filter Rack
Height
R/A
Duct Flange Height
Condenser
Water
Connections
Recommended
Replacement Normal Filter
Size
All dimensions within +/– 0.125". Specifi cations
subject to change without notice.
12 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 13
i Series Model BP
Residential Geothermal Heat Pumps
BP Service Clearances
Engineering Submittal Sheet
Vertical Unit
Service Clearances
A
Blower
I
R
C O
I
L
Compressor
Electrical
Control
Box
Blower Access 18" Minimum 24" Op timum
Compressor Access and Electrical/Control Access 24" Minimum 36" Optimum
Front of Unit
NOTE: The local electric codes may require 36" or more clearance at the electrical control box.
Horizontal Unit
Service Clearances
AIR COIL
Blower Access 18" Minimum 24" Op timum
Blower
NOTE: The local electric codes may require 36" or more clearance at the electrical control box.
13 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Electrical
Control
Box
Compressor Access and Control Access 24" Minimum 36" Optimum
Compressor
Bosch Thermotechnology Corp.
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 14
i Series Model BP
Residential Geothermal Heat Pumps
BP012 (400 CFM) Capacity Data
Entering
Fluid
Temp (F)
50
60
70
80
85
90
100
110
Water
Pressure
Flow
Drop
(GPM)
(FOH)
1.5 1.1 0.5
2.5 2.7 1.2
3.5 4.9 2.1
1.5 1 0.4
2.5 2.6 1.1
3.5 4.7 2.0
1.5 1 0.4
2.5 2.5 1.1
3.5 4.5 1.9
1.5 1 0.4
2.5 2.4 1.0
3.5 4.4 1.9
1.5 0.9 0.4
2.5 2.4 1.0
3.5 4.3 1.9
1.5 0.9 0.4
2.5 2.3 1.0
3.5 4.3 1.9
1.5 0.9 0.4
2.5 2.3 1.0
3.5 4.1 1.8
1.5 0.9 0.4
2.5 2.2 1.0
3.5 4 1.7
Pressure
Drop (PSI)
COOLING HEATING
Entering Air Temp
(db/wb) F
75/63 13.2 10.0 15.1 0.60 21.8 80/67 14.1 10.3 16.0 0.60 23.5 70 8.9 6.3 0.83 3.2 85/71 15.0 10.5 16.9 0.60 25.1 80 8.7 5.9 0.88 2.9 75/63 13.7 10.2 15.4 0.54 25.1 80/67 14.7 10.5 16.4 0.53 27.5 70 9.4 6.8 0.83 3.3 85/71 15.6 10.8 17.3 0.52 29.7 80 9.2 6.3 0.89 3.0 75/63 13.9 10.3 15.6 0.52 26.7 80/67 14.9 10.6 16.5 0.51 29.4 70 9.6 7.0 0.84 3.4 85/71 15.9 10.9 17.5 0.49 32.2 80 9.4 6.5 0.90 3.1 75/63 12.6 9.7 14.7 0.68 18.5 80/67 13.4 10.0 15.5 0.68 19.7 70 10.2 7.5 0.85 3.5 85/71 14.3 10.3 16.4 0.68 21.1 80 10.0 7.1 0.91 3.2 75/63 13.0 9.9 15.0 0.62 20.8 80/67 13.9 10.2 15.9 0.62 22.5 70 10.9 8.1 0.86 3.7 85/71 14.9 10.5 16.8 0.61 24.4 80 10.6 7.6 0.93 3.4 75/63 13.3 10.0 15.1 0.60 22.2 80/67 14.2 10.3 16.0 0.59 24.1 70 11.2 8.4 0.87 3.8 85/71 15.2 10.6 17.0 0.58 26.2 80 10.9 7.9 0.93 3.4 75/63 11.9 9.4 14.2 0.76 15.7 80/67 12.7 9.7 15.0 0.76 16.7 70 11.7 8.9 0.87 3.9 85/71 13.5 10.0 15.9 0.76 17.7 80 11.4 8.3 0.95 3.5 75/63 12.3 9.6 14.5 0.70 17.4 80/67 13.2 9.9 15.4 0.70 18.8 70 12.4 9.6 0.89 4.1 85/71 14.1 10.2 16.3 0.69 20.3 80 12.1 9.0 0.96 3.7 75/63 12.5 9.7 14.7 0.68 18.3 80/67 13.4 10.0 15.6 0.67 19.9 70 12.8 9.9 0.89 4.2 85/71 14.3 10.3 16.5 0.67 21.4 80 12.5 9.3 0.97 3.8 75/63 11.2 9.1 13.8 0.84 13.4 80/67 12.0 9.5 14.6 0.84 14.2 70 13.2 10.2 0.90 4.3 85/71 12.8 9.7 15.4 0.84 15.1 80 12.9 9.7 0.98 3.9 75/63 11.7 9.3 14.1 0.79 14.9 80/67 12.5 9.6 14.9 0.78 15.9 70 14.1 11.1 0.91 4.5 85/71 13.3 9.9 15.8 0.78 17.0 80 13.7 10.5 0.99 4.0 75/63 11.8 9.4 14.2 0.76 15.4 80/67 12.7 9.7 15.0 0.76 16.7 70 14.5 11.6 0.92 4.6 85/71 13.6 10.0 15.9 0.76 18.0 80 14.1 10.9 1.00 4.1 75/63 10.9 9.0 13.6 0.88 12.4 80/67 11.6 9.3 14.3 0.88 13.1 70 14.7 11.7 0.92 4.7 85/71 12.4 9.6 15.1 0.89 14.0 80 14.4 11.1 1.01 4.2 75/63 11.3 9.2 13.8 0.83 13.6 80/67 12.1 9.5 14.6 0.83 14.6 70 15.8 12.8 0.94 4.9 85/71 12.9 9.8 15.5 0.83 15.6 80 15.4 12.1 1.03 4.4 75/63 11.5 9.2 14.0 0.81 14.2 80/67 12.3 9.6 14.8 0.80 15.2 70 16.3 13.3 0.95 5.1 85/71 13.1 9.9 15.6 0.80 16.3 80 15.9 12.5 1.04 4.5 75/63 10.5 8.9 13.3 0.92 11.4 80/67 11.2 9.2 14.1 0.92 12.1 70 16.3 13.3 0.95 5.1 85/71 12.0 9.5 14.9 0.93 12.9 80 16.0 12.6 1.04 4.5 75/63 10.9 9.0 13.6 0.87 12.5 80/67 11.7 9.3 14.4 0.87 13.4 70 17.5 14.5 0.97 5.3 85/71 12.5 9.7 15.2 0.87 14.3 80 17.1 13.7 1.06 4.7 75/63 11.1 9.1 13.7 0.85 13.0 80/67 11.9 9.4 14.5 0.85 14.0 70 18.2 15.1 0.98 5.5 85/71 12.7 9.7 15.4 0.85 14.9 80 17.7 14.2 1.07 4.9 75/63 9.8 8.6 12.8 1.00 9.8 80/67 10.5 8.9 13.6 1.01 10.4 85/71 11.2 9.2 14.4 1.02 11.0 75/63 10.2 8.7 13.1 0.95 10.7 80/67 10.9 9.1 13.9 0.96 11.3 85/71 11.7 9.4 14.7 0.96 12.1 75/63 10.4 8.8 13.2 0.94 11.1 80/67 11.1 9.2 14.0 0.94 11.8 85/71 11.9 9.5 14.8 0.94 12.6 75/63 9.1 8.3 12.4 1.08 8.4 80/67 9.8 8.7 13.1 1.09 8.9 85/71 10.4 9.0 13.8 1.11 9.4 75/63 9.5 8.5 12.6 1.04 9.1 80/67 10.2 8.8 13.4 1.05 9.7 85/71 10.9 9.1 14.1 1.06 10.3 75/63 9.6 8.5 12.7 1.03 9.3 80/67 10.3 8.9 13.5 1.03 10.0 85/71 11.1 9.2 14.3 1.04 10.7
Total
Capacity
(MBTUH)
Sensible Capacity
(MBTUH)
Heat of Rejection (MBTUH)
Power
Input (kW)
EER
Entering
Temp (F)
Water
Fluid
30*
40*
50
60
70
80
* Extended Range - Antifreeze required for entering fl uid
temperture at or below 45 Degrees F.
AHRI/ISO13256-1 certified per formance is rated at entering air conditions
of 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Tabulated unit performance does not include fan or pump power
corrections required for AHRI/ISO standard performance ratings.
Unit performance may be interpolated. Extrapolation is not allowed.
Ratings below 40°F are with a methanol solution.
Due to variations in installation, actual performance may vary from the
tabulated data. Performance contained herein are as a result of extensive testing by FHP and are not express warranties between the parties and may be changed at any time.
Continuous research and development to improve our products may result
in a change to the current design and specifications without notice.
Pressure
Flow
(GPM)
Drop
(FOH)
1.5 1.1 0.5
2.5 2.8 1.2
3.5 5.1 2.2
1.5 1.1 0.5
2.5 2.7 1.2
3.5 5.0 2.1
1.5 1.0 0.5
2.5 2.6 1.1
3.5 4.8 2.1
1.5 1.0 0.4
2.5 2.5 1.1
3.5 4.6 2.0
1.5 1.0 0.4
2.5 2.4 1.1
3.5 4.5 1.9
1.5 0.9 0.4
2.5 2.4 1.0
3.5 4.3 1.9
Engineering Submittal Sheet
Pressure
Drop (PSI)
Entering
Air Temp
Total
Capacity
(F)
(MBTUH)
60 9.1 6.6 0.77 3.5
60 9.6 7.2 0.77 3.7
60 9.9 7.4 0.78 3.7
60 10.4 8.0 0.78 3.9
60 11.1 8.6 0.79 4.1
60 11.5 8.9 0.80 4.2
60 11.9 9.3 0.80 4.4
60 12.7 10.1 0.81 4.6
60 13.1 10.5 0.82 4.7
60 13.4 10.8 0.82 4.8
60 14.4 11.8 0.83 5.1
60 14.9 12.2 0.84 5.2
60 15.0 12.3 0.84 5.3
60 16.2 13.5 0.85 5.6
60 16.7 14.1 0.86 5.7
60 16.7 13.9 0.86 5.7
60 18.0 15.3 0.87 6.1
60 18.7 15.9 0.88 6.2
Heat of
Absorption
(MBTUH)
Power
Input (kW)
COP
14 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 15
i Series Model BP
Residential Geothermal Heat Pumps
BP018 (575 CFM) Capacity Data
Entering
Fluid
Temp (F)
50
60
70
80
85
90
100
110
Water
Pressure
Flow
Drop
(GPM)
(FOH)
2.5 3.2 1.4
4 7.4 3.2
5 11.1 4.8
2.5 3.1 1.3
4 7.2 3.1
5 10.7 4.6
2.5 3 1.3
4 7 3.0
5 10.4 4.5
2.5 2.9 1.3
4 6.7 2.9
5 10.1 4.4
2.5 2.8 1.2
4 6.6 2.9
5 9.9 4.3
2.5 2.8 1.2
4 6.5 2.8
5 9.8 4.2
2.5 2.7 1.2
4 6.3 2.7
5 9.5 4.1
2.5 2.6 1.1
4 6.1 2.6
5 9.2 4.0
Pressure
Drop (PSI)
COOLING HEATING
Entering Air Temp
(db/wb) F
75/63 20.2 15.2 23.3 0.95 21.2 80/67 21.5 15.6 24.6 0.93 23.1 70 13.0 9.4 1.08 3.5 85/71 22.8 15.9 25.8 0.90 25.3 80 12.7 8.8 1.16 3.2 75/63 20.8 15.4 23.9 0.95 21.8 80/67 22.2 15.8 25.2 0.92 24.0 70 13.6 9.9 1.11 3.6 85/71 23.5 16.2 26.5 0.89 26.4 80 13.2 9.3 1.18 3.3 75/63 21.0 15.5 24.1 0.96 21.9 80/67 22.4 15.9 25.4 0.93 24.2 70 13.9 10.1 1.12 3.7 85/71 23.8 16.2 26.7 0.89 26.8 80 13.4 9.5 1.19 3.3 75/63 19.4 14.8 22.5 0.98 19.7 80/67 20.6 15.2 23.7 0.97 21.3 70 14.9 11.0 1.15 3.8 85/71 21.9 15.6 24.9 0.95 23.0 80 14.5 10.4 1.23 3.5 75/63 19.9 15.0 23.0 0.96 20.7 80/67 21.2 15.4 24.3 0.94 22.6 70 15.6 11.7 1.17 3.9 85/71 22.6 15.8 25.5 0.91 24.8 80 15.2 11.0 1.25 3.6 75/63 20.1 15.1 23.2 0.96 21.0 80/67 21.4 15.5 24.5 0.93 23.0 70 15.9 11.9 1.17 4.0 85/71 22.8 15.9 25.7 0.90 25.2 80 15.4 11.2 1.26 3.6 75/63 18.5 14.4 21.8 1.04 17.7 80/67 19.7 14.8 23.0 1.04 19.0 70 16.8 12.8 1.20 4.1 85/71 20.9 15.2 24.2 1.03 20.3 80 16.5 12.1 1.29 3.8 75/63 19.0 14.6 22.2 1.01 18.9 80/67 20.3 15.0 23.4 0.99 20.5 70 17.7 13.6 1.21 4.3 85/71 21.5 15.4 24.7 0.98 22.0 80 17.3 12.8 1.31 3.9 75/63 19.2 14.7 22.3 0.99 19.3 80/67 20.5 15.1 23.6 0.98 21.0 70 18.0 13.9 1.22 4.3 85/71 21.7 15.5 24.8 0.96 22.6 80 17.5 13.1 1.31 3.9 75/63 17.6 14.0 21.2 1.13 15.5 80/67 18.7 14.4 22.3 1.14 16.5 70 18.9 14.7 1.23 4.5 85/71 19.9 14.8 23.5 1.14 17.5 80 18.4 14.0 1.33 4.0 75/63 18.1 14.2 21.5 1.08 16.7 80/67 19.2 14.7 22.7 1.08 17.8 70 19.9 15.7 1.24 4.7 85/71 20.5 15.0 23.9 1.07 19.1 80 19.4 14.8 1.35 4.2 75/63 18.2 14.3 21.6 1.07 17.0 80/67 19.4 14.7 22.8 1.06 18.3 70 20.3 16.1 1.24 4.8 85/71 20.7 15.1 24.1 1.05 19.7 80 19.8 15.1 1.36 4.3 75/63 17.1 13.8 20.9 1.19 14.4 80/67 18.2 14.2 22.0 1.19 15.3 70 21.0 16.8 1.25 4.9 85/71 19.3 14.6 23.1 1.20 16.1 80 20.5 16.0 1.37 4.4 75/63 17.6 14.0 21.2 1.13 15.5 80/67 18.7 14.5 22.3 1.13 16.5 70 22.1 17.9 1.26 5.1 85/71 19.9 14.8 23.5 1.13 17.6 80 21.6 17.0 1.39 4.6 75/63 17.8 14.1 21.3 1.12 15.9 80/67 18.9 14.5 22.4 1.11 17.0 70 22.6 18.4 1.27 5.2 85/71 20.1 14.9 23.7 1.11 18.2 80 22.0 17.3 1.39 4.6 75/63 16.7 13.6 20.6 1.24 13.4 80/67 17.7 14.1 21.7 1.25 14.1 70 23.2 18.9 1.28 5.3 85/71 18.8 14.5 22.8 1.26 14.9 80 22.7 18.0 1.41 4.7 75/63 17.1 13.8 20.9 1.19 14.4 80/67 18.2 14.2 22.0 1.19 15.3 70 24.5 20.2 1.29 5.6 85/71 19.4 14.7 23.2 1.19 16.3 80 23.9 19.1 1.44 4.9 75/63 17.3 13.9 21.0 1.17 14.8 80/67 18.4 14.3 22.1 1.17 15.7 70 25.0 20.7 1.30 5.6 85/71 19.6 14.8 23.3 1.17 16.8 80 24.4 19.5 1.45 4.9 75/63 15.7 13.3 20.0 1.37 11.5 80/67 16.8 13.7 21.1 1.38 12.2 85/71 17.8 14.1 22.2 1.39 12.8 75/63 16.2 13.4 20.3 1.31 12.3 80/67 17.2 13.9 21.4 1.32 13.0 85/71 18.4 14.3 22.5 1.32 13.9 75/63 16.3 13.5 20.3 1.29 12.6 80/67 17.4 13.9 21.4 1.30 13.4 85/71 18.5 14.3 22.6 1.30 14.2 75/63 14.8 12.9 19.5 1.49 9.9 80/67 15.8 13.3 20.5 1.51 10.4 85/71 16.8 13.7 21.6 1.53 10.9 75/63 15.2 13.0 19.7 1.44 10.5 80/67 16.2 13.5 20.8 1.45 11.1 85/71 17.3 14.0 21.9 1.47 11.8 75/63 15.3 13.1 19.7 1.42 10.7 80/67 16.4 13.5 20.9 1.44 11.4 85/71 17.4 14.0 22.0 1.45 12.0
Total
Capacity
(MBTUH)
Sensible Capacity
(MBTUH)
Heat of Rejection (MBTUH)
Power
Input (kW)
EER
Entering
Temp (F)
Water
Fluid
30*
40*
50
60
70
80
* Extended Range - Antifreeze required for entering fl uid
temperture at or below 45 Degrees F.
AHRI/ISO13256-1 certified per formance is rated at entering air conditions
of 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Tabulated unit performance does not include fan or pump power
corrections required for AHRI/ISO standard performance ratings.
Unit performance may be interpolated. Extrapolation is not allowed.
Ratings below 40°F are with a methanol solution.
Due to variations in installation, actual performance may vary from the
tabulated data. Performance contained herein are as a result of extensive testing by FHP and are not express warranties between the parties and may be changed at any time.
Continuous research and development to improve our products may result
in a change to the current design and specifications without notice.
Pressure
Flow
(GPM)
Drop
(FOH)
2.5 3.4 1.5
4 7.9 3.4
5 11.9 5.1
2.5 3.3 1.4
4 7.7 3.3
5 11.4 5.0
2.5 3.2 1.4
4 7.4 3.2
5 11.1 4.8
2.5 3.1 1.3
4 7.1 3.1
5 10.7 4.6
2.5 3.0 1.3
4 6.9 3.0
5 10.3 4.5
2.5 2.9 1.2
4 6.7 2.9
5 10.0 4.3
Engineering Submittal Sheet
Pressure
Drop (PSI)
Entering
Air Temp
Total
Capacity
(F)
(MBTUH)
60 13.4 10.0 1.03 3.8
60 14.0 10.5 1.05 3.9
60 14.2 10.8 1.06 3.9
60 15.3 11.7 1.09 4.1
60 16.0 12.4 1.11 4.2
60 16.3 12.7 1.11 4.3
60 17.3 13.5 1.13 4.5
60 18.2 14.4 1.14 4.7
60 18.5 14.8 1.14 4.8
60 19.4 15.5 1.15 5.0
60 20.4 16.6 1.15 5.2
60 20.8 17.0 1.15 5.3
60 21.5 17.6 1.15 5.5
60 22.7 18.9 1.16 5.8
60 23.2 19.4 1.16 5.9
60 23.7 19.9 1.16 6.0
60 25.1 21.3 1.16 6.3
60 25.6 21.8 1.17 6.4
Heat of
Absorption
(MBTUH)
Power
Input (kW)
COP
15 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 16
i Series Model BP
Residential Geothermal Heat Pumps
BP024 (800 CFM) Capacity Data
Entering
Fluid
Temp (F)
50
60
70
80
85
90
100
110
Water
Pressure
Flow
Drop
(GPM)
(FOH)
3 2.1 0.9
4 3.6 1.6
6 7.4 3.2
3 2.1 0.9
4 3.5 1.5
6 7.2 3.1
3 2 0.9
4 3.3 1.4
6 6.9 3.0
3 1.9 0.8
4 3.2 1.4
6 6.7 2.9
3 1.9 0.8
4 3.2 1.4
6 6.6 2.9
3 1.9 0.8
4 3.1 1.3
6 6.5 2.8
3 1.8 0.8
4 3 1.3
6 6.3 2.7
3 1.8 0.8
4 3 1.3
6 6.1 2.6
Pressure
Drop (PSI)
COOLING HEATING
Entering Air Temp
(db/wb) F
75/63 27.1 20.5 30.5 1.05 25.9 80/67 28.8 21.0 32.3 1.06 27.3 70 17.8 12.8 1.53 3.4 85/71 30.6 21.6 34.1 1.06 28.8 80 17.6 11.9 1.71 3.0 75/63 27.6 20.8 30.8 0.98 28.2 80/67 29.4 21.3 32.7 0.98 30.0 70 18.3 13.2 1.54 3.5 85/71 31.2 21.8 34.6 0.98 31.8 80 18.1 12.3 1.71 3.1 75/63 28.1 21.0 31.1 0.92 30.8 80/67 30.0 21.5 33.0 0.91 33.1 70 18.9 13.8 1.55 3.6 85/71 31.9 22.1 34.9 0.90 35.5 80 18.6 12.8 1.72 3.2 75/63 25.8 20.0 29.7 1.20 21.5 80/67 27.5 20.5 31.5 1.21 22.7 70 20.3 15.1 1.57 3.8 85/71 29.2 21.1 33.3 1.22 23.9 80 20.0 14.2 1.74 3.4 75/63 26.3 20.2 30.0 1.14 23.1 80/67 28.1 20.7 31.9 1.14 24.6 70 21.0 15.7 1.58 3.9 85/71 29.9 21.3 33.7 1.15 26.1 80 20.6 14.8 1.76 3.4 75/63 26.8 20.4 30.4 1.08 24.9 80/67 28.7 21.0 32.2 1.08 26.7 70 21.7 16.4 1.59 4.0 85/71 30.5 21.6 34.0 1.07 28.5 80 21.3 15.4 1.77 3.5 75/63 24.6 19.4 29.0 1.36 18.1 80/67 26.2 20.0 30.6 1.37 19.1 70 23.0 17.6 1.61 4.2 85/71 27.8 20.6 32.3 1.39 20.1 80 22.6 16.6 1.79 3.7 75/63 25.1 19.6 29.3 1.30 19.4 80/67 26.7 20.3 30.9 1.31 20.5 70 23.8 18.4 1.62 4.3 85/71 28.4 20.8 32.7 1.32 21.6 80 23.4 17.3 1.81 3.8 75/63 25.6 19.8 29.6 1.24 20.7 80/67 27.3 20.5 31.3 1.24 22.1 70 24.7 19.2 1.64 4.4 85/71 29.0 21.1 33.1 1.24 23.3 80 24.2 18.0 1.83 3.9 75/63 23.3 18.9 28.2 1.53 15.3 80/67 24.8 19.5 29.7 1.54 16.1 70 25.8 20.3 1.66 4.6 85/71 26.4 20.1 31.4 1.56 17.0 80 25.4 19.2 1.85 4.0 75/63 23.8 19.1 28.4 1.46 16.3 80/67 25.3 19.7 30.1 1.48 17.2 70 26.8 21.2 1.67 4.7 85/71 27.0 20.3 31.8 1.49 18.2 80 26.3 20.0 1.87 4.1 75/63 24.2 19.3 28.7 1.41 17.2 80/67 25.9 19.9 30.4 1.41 18.4 70 27.9 22.2 1.69 4.8 85/71 27.6 20.5 32.2 1.42 19.5 80 27.3 21.0 1.88 4.2 75/63 22.7 18.7 27.8 1.61 14.1 80/67 24.1 19.3 29.3 1.63 14.8 70 28.8 23.1 1.70 4.9 85/71 25.6 19.9 30.9 1.65 15.5 80 28.4 21.9 1.90 4.4 75/63 23.1 18.8 28.0 1.55 14.9 80/67 24.7 19.4 29.7 1.56 15.8 70 29.9 24.3 1.73 5.1 85/71 26.2 20.1 31.3 1.58 16.6 80 29.4 22.9 1.92 4.5 75/63 23.5 19.0 28.3 1.49 15.8 80/67 25.1 19.7 29.9 1.50 16.8 70 31.3 25.4 1.75 5.2 85/71 26.8 20.2 31.7 1.51 17.8 80 30.6 24.0 1.95 4.6 75/63 22.0 18.4 27.4 1.71 12.9 80/67 23.5 19.0 29.0 1.72 13.7 70 31.9 26.0 1.76 5.3 85/71 24.9 19.6 30.5 1.74 14.3 80 31.4 24.7 1.97 4.7 75/63 22.5 18.6 27.7 1.64 13.7 80/67 23.9 19.2 29.2 1.66 14.5 70 33.3 27.3 1.79 5.4 85/71 25.5 19.7 30.9 1.67 15.3 80 32.6 25.9 2.00 4.8 75/63 22.9 18.7 27.9 1.59 14.5 80/67 24.4 19.3 29.5 1.59 15.3 70 34.8 28.6 1.83 5.6 85/71 26.0 20.0 31.2 1.60 16.2 80 34.0 27.1 2.04 4.9 75/63 20.8 17.8 26.7 1.90 10.9 80/67 22.1 18.5 28.2 1.92 11.5 85/71 23.5 19.1 29.7 1.94 12.1 75/63 21.2 18.0 27.0 1.84 11.5 80/67 22.5 18.7 28.4 1.86 12.1 85/71 24.0 19.3 29.9 1.87 12.8 75/63 21.5 18.2 27.2 1.78 12.1 80/67 23.0 18.8 28.7 1.79 12.9 85/71 24.5 19.4 30.2 1.81 13.6 75/63 19.4 17.3 26.1 2.13 9.2 80/67 20.8 17.9 27.5 2.14 9.7 85/71 22.1 18.6 29.0 2.16 10.3 75/63 19.8 17.5 26.2 2.06 9.6 80/67 21.1 18.1 27.7 2.07 10.2 85/71 22.5 18.8 29.1 2.08 10.8 75/63 20.1 17.6 26.4 2.01 10.0 80/67 21.5 18.2 27.9 2.01 10.7 85/71 23.0 18.9 29.4 2.02 11.4
Total
Capacity
(MBTUH)
Sensible Capacity
(MBTUH)
Heat of Rejection (MBTUH)
Power
Input (kW)
EER
Entering
Temp (F)
Water
Fluid
30*
40*
50
60
70
80
* Extended Range - Antifreeze required for entering fl uid
temperture at or below 45 Degrees F.
AHRI/ISO13256-1 certified per formance is rated at entering air conditions
of 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Tabulated unit performance does not include fan or pump power
corrections required for AHRI/ISO standard performance ratings.
Unit performance may be interpolated. Extrapolation is not allowed.
Ratings below 40°F are with a methanol solution.
Due to variations in installation, actual performance may vary from the
tabulated data. Performance contained herein are as a result of extensive testing by FHP and are not express warranties between the parties and may be changed at any time.
Continuous research and development to improve our products may result
in a change to the current design and specifications without notice.
Pressure
Flow
(GPM)
Drop
(FOH)
3 2.2 1.0
4 3.8 1.6
6 7.8 3.4
3 2.2 0.9
4 3.6 1.6
6 7.5 3.3
3 2.1 0.9
4 3.5 1.5
6 7.3 3.1
3 2.0 0.9
4 3.4 1.5
6 7.0 3.0
3 2.0 0.8
4 3.3 1.4
6 6.8 2.9
3 1.9 0.8
4 3.2 1.4
6 6.6 2.8
Engineering Submittal Sheet
Pressure
Drop (PSI)
Entering
Air Temp
Total
Capacity
(F)
(MBTUH)
60 18.2 13.6 1.38 3.9
60 18.7 14.1 1.38 3.9
60 19.3 14.7 1.39 4.1
60 20.7 16.0 1.41 4.3
60 21.3 16.6 1.41 4.4
60 22.1 17.4 1.42 4.5
60 23.4 18.6 1.44 4.8
60 24.2 19.4 1.45 4.9
60 25.2 20.3 1.46 5.0
60 26.3 21.3 1.48 5.2
60 27.3 22.3 1.50 5.3
60 28.5 23.4 1.51 5.5
60 29.3 24.2 1.52 5.6
60 30.6 25.4 1.54 5.8
60 32.0 26.8 1.57 6.0
60 32.5 27.2 1.58 6.0
60 33.9 28.6 1.60 6.2
60 35.5 30.4 1.64 6.3
Heat of
Absorption
(MBTUH)
Power
Input (kW)
COP
16 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 17
i Series Model BP
Residential Geothermal Heat Pumps
BP030 (1000 CFM) Capacity Data
Entering
Fluid
Temp (F)
50
60
70
80
85
90
100
110
Water
Pressure
Flow
Drop
(GPM)
(FOH)
4 1.3 0.6
6 2.6 1.1
8 4.4 1.9
4 1.2 0.5
6 2.5 1.1
8 4.3 1.9
4 1.2 0.5
6 2.5 1.1
8 4.1 1.8
4 1.1 0.5
6 2.4 1.0
8 4 1.7
4 1.1 0.5
6 2.3 1.0
8 3.9 1.7
4 1.1 0.5
6 2.3 1.0
8 3.9 1.7
4 1.1 0.5
6 2.2 1.0
8 3.7 1.6
4 1 0.4
6 2.2 1.0
8 3.6 1.6
Pressure
Drop (PSI)
COOLING HEATING
Entering Air Temp
(db/wb) F
75/63 30.0 24.0 34.0 1.23 24.5 80/67 31.9 24.6 36.1 1.27 25.2 70 19.4 14.1 1.60 3.6 85/71 33.8 25.4 38.1 1.31 25.8 80 19.0 13.0 1.78 3.1 75/63 30.9 24.3 34.6 1.14 27.2 80/67 32.8 25.0 36.7 1.17 28.1 70 20.0 14.6 1.60 3.7 85/71 34.8 25.7 38.9 1.21 28.7 80 19.6 13.3 1.78 3.2 75/63 31.3 24.5 34.9 1.09 28.8 80/67 33.2 25.2 36.9 1.12 29.7 70 20.5 15.2 1.60 3.8 85/71 35.3 25.9 39.2 1.16 30.5 80 19.8 14.0 1.78 3.2 75/63 28.7 23.4 33.1 1.38 20.8 80/67 30.4 24.2 35.0 1.42 21.5 70 21.8 16.5 1.60 4.0 85/71 32.3 24.9 37.1 1.47 22.0 80 21.5 15.3 1.79 3.5 75/63 29.5 23.7 33.7 1.29 22.9 80/67 31.4 24.4 35.7 1.33 23.7 70 22.8 17.3 1.60 4.2 85/71 33.2 25.2 37.7 1.37 24.3 80 22.3 16.2 1.79 3.6 75/63 29.9 23.9 33.9 1.25 24.0 80/67 31.7 24.7 35.9 1.28 24.9 70 23.3 17.8 1.60 4.3 85/71 33.8 25.3 38.2 1.32 25.7 80 22.5 16.6 1.79 3.7 75/63 27.3 22.8 32.3 1.54 17.7 80/67 29.0 23.6 34.1 1.58 18.4 70 24.9 19.3 1.61 4.5 85/71 30.8 24.4 36.1 1.63 18.9 80 24.3 18.1 1.81 3.9 75/63 28.0 23.1 32.7 1.46 19.3 80/67 29.9 23.9 34.7 1.49 20.1 70 26.0 20.8 1.62 4.7 85/71 31.7 24.7 36.7 1.53 20.7 80 25.6 19.6 1.82 4.1 75/63 28.4 23.3 32.9 1.41 20.1 80/67 30.3 24.0 35.0 1.44 21.0 70 26.5 20.8 1.63 4.8 85/71 32.2 24.8 37.1 1.48 21.7 80 25.9 19.7 1.82 4.2 75/63 25.9 22.3 31.4 1.72 15.1 80/67 27.6 23.0 33.2 1.76 15.7 70 27.9 22.2 1.64 5.0 85/71 29.3 23.8 35.1 1.81 16.2 80 27.3 21.0 1.84 4.4 75/63 26.6 22.6 31.8 1.63 16.3 80/67 28.3 23.3 33.7 1.67 17.0 70 29.3 23.5 1.66 5.2 85/71 30.2 24.0 35.7 1.71 17.7 80 28.8 22.5 1.86 4.5 75/63 26.9 22.7 32.0 1.59 16.9 80/67 28.7 23.4 34.0 1.62 17.7 70 30.0 24.3 1.67 5.2 85/71 30.6 24.3 36.0 1.66 18.5 80 29.4 22.9 1.87 4.6 75/63 25.2 22.0 31.0 1.82 13.9 80/67 26.8 22.8 32.8 1.85 14.5 70 31.2 25.4 1.70 5.4 85/71 28.6 23.5 34.7 1.91 15.0 80 30.6 24.1 1.89 4.7 75/63 25.9 22.2 31.4 1.73 15.0 80/67 27.6 23.1 33.2 1.76 15.7 70 33.2 27.6 1.74 5.6 85/71 29.4 23.8 35.2 1.80 16.3 80 32.2 25.5 1.93 4.9 75/63 26.2 22.4 31.6 1.68 15.6 80/67 27.9 23.2 33.4 1.71 16.3 70 34.1 28.5 1.77 5.7 85/71 29.8 23.9 35.4 1.75 17.0 80 33.5 27.3 1.97 5.0 75/63 24.5 21.7 30.5 1.92 12.8 80/67 26.1 22.5 32.3 1.96 13.4 70 34.9 28.7 1.79 5.7 85/71 27.8 23.3 34.2 2.00 13.9 80 34.2 27.3 1.99 5.0 75/63 25.2 21.9 31.0 1.83 13.8 80/67 26.8 22.8 32.7 1.86 14.4 70 36.9 30.5 1.86 5.8 85/71 28.5 23.6 34.6 1.90 15.0 80 36.1 29.0 2.06 5.1 75/63 25.5 22.1 31.2 1.78 14.3 80/67 27.2 22.9 33.0 1.81 15.0 70 38.5 32.1 1.91 5.9 85/71 29.0 23.6 34.9 1.85 15.7 80 37.7 31.3 2.12 5.2 75/63 23.0 21.1 29.7 2.14 10.8 80/67 24.6 22.0 31.5 2.17 11.3 85/71 26.2 22.8 33.2 2.22 11.8 75/63 23.6 21.4 30.1 2.04 11.6 80/67 25.3 22.1 31.9 2.08 12.2 85/71 26.9 23.0 33.7 2.12 12.7 75/63 23.9 21.5 30.2 2.00 12.0 80/67 25.6 22.3 32.1 2.03 12.6 85/71 27.3 23.2 33.9 2.07 13.2 75/63 21.5 20.5 29.0 2.39 9.0 80/67 23.0 21.4 30.7 2.42 9.5 85/71 24.6 22.2 32.4 2.45 10.0 75/63 22.1 20.8 29.3 2.29 9.7 80/67 23.6 21.6 31.0 2.32 10.2 85/71 25.3 22.5 32.8 2.35 10.8 75/63 22.4 20.8 29.5 2.25 10.0 80/67 23.9 21.7 31.1 2.27 10.5 85/71 25.6 22.6 32.9 2.30 11.1
Total
Capacity
(MBTUH)
Sensible Capacity
(MBTUH)
Heat of Rejection (MBTUH)
Power
Input (kW)
EER
Entering
Temp (F)
Water
Fluid
30*
40*
50
60
70
80
* Extended Range - Antifreeze required for entering fl uid
temperture at or below 45 Degrees F.
AHRI/ISO13256-1 certified per formance is rated at entering air conditions
of 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Tabulated unit performance does not include fan or pump power
corrections required for AHRI/ISO standard performance ratings.
Unit performance may be interpolated. Extrapolation is not allowed.
Ratings below 40°F are with a methanol solution.
Due to variations in installation, actual performance may vary from the
tabulated data. Performance contained herein are as a result of extensive testing by FHP and are not express warranties between the parties and may be changed at any time.
Continuous research and development to improve our products may result
in a change to the current design and specifications without notice.
Pressure
Flow
(GPM)
Drop
(FOH)
4 1.3 0.6
6 2.8 1.2
8 4.7 2.0
4 1.3 0.6
6 2.7 1.2
8 4.5 1.9
4 1.2 0.5
6 2.6 1.1
8 4.3 1.9
4 1.2 0.5
6 2.5 1.1
8 4.2 1.8
4 1.2 0.5
6 2.4 1.0
8 4.1 1.8
4 1.1 0.5
6 2.3 1.0
8 3.9 1.7
Engineering Submittal Sheet
Pressure
Drop (PSI)
Entering
Air Temp
Total
Capacity
(F)
(MBTUH)
60 19.8 15.0 1.43 4.1
60 20.5 15.7 1.43 4.2
60 21.0 16.1 1.43 4.3
60 22.4 17.6 1.43 4.6
60 23.4 18.5 1.43 4.8
60 23.9 19.2 1.43 4.9
60 25.3 20.4 1.43 5.2
60 26.5 21.6 1.44 5.4
60 27.2 22.5 1.45 5.5
60 28.6 23.7 1.46 5.7
60 30.1 25.1 1.48 5.9
60 30.8 25.9 1.50 6.0
60 32.1 26.9 1.52 6.2
60 33.7 28.4 1.55 6.4
60 34.8 29.6 1.58 6.4
60 35.8 30.4 1.60 6.5
60 37.7 32.1 1.67 6.6
60 39.2 33.4 1.72 6.7
Heat of
Absorption
(MBTUH)
Power
Input (kW)
COP
17 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 18
i Series Model BP
Residential Geothermal Heat Pumps
BP036 (1200 CFM) Capacity Data
Entering
Fluid
Temp (F)
50
60
70
80
85
90
100
110
Water
Pressure
Flow
Drop
(GPM)
(FOH)
4.5 2.1 0.9
6 3.4 1.5
9 7.2 3.1
4.5 2 0.9
6 3.3 1.4
9 6.9 3.0
4.5 1.9 0.8
6 3.2 1.4
9 6.7 2.9
4.5 1.9 0.8
6 3.1 1.3
9 6.5 2.8
4.5 1.8 0.8
6 3.1 1.3
9 6.4 2.8
4.5 1.8 0.8
6 3 1.3
9 6.3 2.7
4.5 1.7 0.7
6 2.9 1.3
9 6.1 2.6
4.5 1.7 0.7
6 2.8 1.2
9 5.9 2.6
Pressure
Drop (PSI)
COOLING HEATING
Entering
Air Temp
(db/wb) F
75/63 37.1 29.1 42.4 1.64 22.6 80/67 39.4 30.0 44.8 1.66 23.7 70 25.7 18.8 2.09 3.6 85/71 42.0 30.7 47.5 1.68 24.9 80 25.2 17.4 2.31 3.2 75/63 37.8 29.4 42.9 1.56 24.2 80/67 40.3 30.3 45.4 1.58 25.6 70 26.7 19.4 2.10 3.7 85/71 42.9 31.2 48.1 1.59 27.0 80 26.0 18.4 2.32 3.3 75/63 38.6 29.7 43.4 1.48 26.1 80/67 41.2 30.6 46.1 1.48 27.7 70 27.8 20.5 2.12 3.8 85/71 43.9 31.4 48.9 1.49 29.4 80 27.1 19.4 2.34 3.4 75/63 35.4 28.4 41.3 1.81 19.5 80/67 37.8 29.2 43.7 1.84 20.6 70 29.2 21.5 2.14 4.0 85/71 40.1 30.2 46.1 1.86 21.6 80 28.3 20.6 2.36 3.5 75/63 36.2 28.7 41.8 1.74 20.8 80/67 38.5 29.6 44.2 1.75 22.0 70 30.6 22.6 2.16 4.2 85/71 41.0 30.5 46.8 1.77 23.2 80 29.7 21.6 2.37 3.7 75/63 36.9 29.0 42.3 1.66 22.3 80/67 39.5 29.9 44.9 1.67 23.7 70 31.4 24.3 2.17 4.2 85/71 42.0 30.8 47.5 1.67 25.1 80 31.1 22.8 2.39 3.8 75/63 33.9 27.8 40.3 2.00 17.0 80/67 36.1 28.7 42.6 2.02 17.9 70 32.9 25.5 2.19 4.4 85/71 38.4 29.6 45.0 2.04 18.8 80 32.3 24.4 2.41 3.9 75/63 34.5 28.0 40.6 1.92 18.0 80/67 36.8 28.9 43.0 1.94 19.0 70 34.4 27.0 2.21 4.6 85/71 39.2 29.9 45.6 1.95 20.1 80 33.8 25.6 2.43 4.1 75/63 35.2 28.3 41.1 1.84 19.1 80/67 37.6 29.2 43.6 1.85 20.3 70 35.7 28.4 2.23 4.7 85/71 40.0 30.1 46.1 1.86 21.5 80 35.0 27.0 2.45 4.2 75/63 32.1 27.0 39.1 2.19 14.6 80/67 34.2 28.0 41.3 2.22 15.4 70 36.9 29.7 2.24 4.8 85/71 36.4 28.9 43.7 2.24 16.2 80 36.3 28.0 2.47 4.3 75/63 32.7 27.3 39.5 2.11 15.4 80/67 35.0 28.3 41.9 2.13 16.4 70 38.7 30.8 2.26 5.0 85/71 37.3 29.2 44.2 2.15 17.3 80 37.8 29.7 2.49 4.5 75/63 33.5 27.4 40.0 2.04 16.4 80/67 35.8 28.5 42.4 2.05 17.4 70 40.9 33.3 2.29 5.2 85/71 38.2 29.4 44.9 2.06 18.5 80 39.7 31.0 2.52 4.6 75/63 31.2 26.7 38.6 2.30 13.5 80/67 33.3 27.6 40.7 2.32 14.3 70 41.4 33.6 2.30 5.3 85/71 35.4 28.5 43.0 2.35 15.1 80 40.5 32.2 2.53 4.7 75/63 31.9 27.0 39.0 2.22 14.4 80/67 34.0 27.9 41.2 2.24 15.2 70 43.3 34.9 2.33 5.5 85/71 36.6 28.1 43.9 2.26 16.2 80 42.4 33.7 2.56 4.9 75/63 32.5 27.2 39.4 2.14 15.2 80/67 34.8 28.2 41.7 2.15 16.1 70 45.6 38.5 2.37 5.6 85/71 37.1 29.1 44.1 2.16 17.1 80 44.7 36.2 2.60 5.0 75/63 30.3 26.3 38.0 2.41 12.5 80/67 32.4 27.3 40.1 2.44 13.3 70 46.2 38.1 2.37 5.7 85/71 34.6 28.2 42.4 2.46 14.1 80 45.3 36.4 2.61 5.1 75/63 31.0 26.6 38.4 2.33 13.3 80/67 33.1 27.5 40.7 2.35 14.1 70 48.1 40.4 2.41 5.9 85/71 35.2 28.5 42.8 2.37 14.8 80 47.1 38.8 2.65 5.2 75/63 31.6 26.9 38.8 2.25 14.0 80/67 33.8 27.8 41.0 2.26 14.9 70 51.4 43.3 2.46 6.1 85/71 35.8 28.7 43.2 2.28 15.7 80 49.7 40.1 2.69 5.4 75/63 28.6 25.6 37.0 2.66 10.7 80/67 30.5 26.6 39.1 2.68 11.4 85/71 32.6 27.6 41.2 2.69 12.1 75/63 29.2 25.9 37.4 2.58 11.3 80/67 31.2 26.8 39.4 2.59 12.0 85/71 33.4 27.7 41.7 2.60 12.8 75/63 29.8 26.1 37.7 2.49 11.9 80/67 31.9 27.0 39.9 2.51 12.7 85/71 34.0 28.1 42.1 2.51 13.5 75/63 26.8 24.2 36.2 2.94 9.1 80/67 28.7 25.9 38.1 2.95 9.7 85/71 30.8 26.8 40.3 2.97 10.4 75/63 27.4 24.4 36.4 2.85 9.6 80/67 29.3 26.1 38.4 2.86 10.2 85/71 31.3 27.1 40.5 2.87 10.9 75/63 27.9 25.3 36.7 2.77 10.1 80/67 29.9 26.4 38.7 2.77 10.8 85/71 32.0 27.4 40.8 2.77 11.5
Total
Capacity
(MBTUH)
Sensible Capacity (MBTUH)
Heat of Rejection (MBTUH)
Power
Input (kW)
EER
Entering
Temp (F)
Water
Fluid
30*
40*
50
60
70
80
* Extended Range - Antifreeze required for entering fl uid
temperture at or below 45 Degrees F.
AHRI/ISO13256-1 certified per formance is rated at entering air conditions
of 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Tabulated unit performance does not include fan or pump power
corrections required for AHRI/ISO standard performance ratings.
Unit performance may be interpolated. Extrapolation is not allowed.
Ratings below 40°F are with a methanol solution.
Due to variations in installation, actual performance may vary from the
tabulated data. Performance contained herein are as a result of extensive testing by FHP and are not express warranties between the parties and may be changed at any time.
Continuous research and development to improve our products may result
in a change to the current design and specifications without notice.
Pressure
Flow
(GPM)
Drop
(FOH)
4.5 1.5 0.7
6 2.6 1.1
9 5.3 2.3
4.5 1.5 0.6
6 2.5 1.1
9 5.1 2.2
4.5 1.4 0.6
6 2.4 1.0
9 5.0 2.2
4.5 1.4 0.6
6 2.3 1.0
9 4.8 2.1
4.5 1.3 0.6
6 2.2 1.0
9 4.6 2.0
4.5 1.3 0.6
6 2.2 0.9
9 4.5 1.9
Engineering Submittal Sheet
Pressure
Drop
(PSI)
Entering Air Temp
Total
Capacity
(F)
(MBTUH)
60 26.3 20.0 1.90 4.1
60 27.0 20.4 1.91 4.2
60 28.3 21.7 1.92 4.3
60 29.5 23.1 1.94 4.5
60 30.8 24.6 1.96 4.6
60 32.1 25.3 1.97 4.8
60 33.7 26.9 1.99 5.0
60 35.0 28.4 2.01 5.1
60 36.6 29.6 2.03 5.3
60 37.8 30.8 2.04 5.4
60 39.6 32.6 2.06 5.6
60 41.6 34.6 2.08 5.9
60 42.3 35.1 2.09 5.9
60 44.4 37.5 2.12 6.1
60 47.4 40.4 2.16 6.4
60 47.0 39.6 2.16 6.4
60 49.1 41.8 2.19 6.6
60 52.8 45.3 2.24 6.9
Heat of
Absorption
(MBTUH)
Power
Input (kW)
COP
18 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 19
i Series Model BP
Residential Geothermal Heat Pumps
BP042 (1400 CFM) Capacity Data
Entering
Fluid
Temp (F)
50
60
70
80
85
90
100
110
Water
Pressure
Flow
Drop
(GPM)
(FOH)
5 1.5 0.6
8 3.5 1.5
11 6.2 2.7
5 1.4 0.6
8 3.4 1.5
11 6 2.6
5 1.4 0.6
8 3.3 1.4
11 5.8 2.5
5 1.4 0.6
8 3.2 1.4
11 5.6 2.4
5 1.3 0.6
8 3.1 1.3
11 5.5 2.4
5 1.3 0.6
8 3.1 1.3
11 5.4 2.3
5 1.3 0.6
8 3 1.3
11 5.3 2.3
5 1.2 0.5
8 2.9 1.3
11 5.1 2.2
Pressure
Drop (PSI)
COOLING HEATING
Entering Air Temp
(db/wb) F
75/63 43.5 34.3 49.1 1.68 25.8 80/67 46.3 35.4 51.9 1.70 27.3 70 25.5 18.8 2.09 3.6 85/71 49.2 36.3 55.0 1.72 28.6 80 25.0 17.5 2.33 3.1 75/63 45.0 35.0 50.1 1.53 29.4 80/67 48.1 36.0 53.2 1.54 31.3 70 26.9 20.2 2.11 3.7 85/71 51.0 37.0 56.2 1.54 33.2 80 26.3 18.8 2.35 3.3 75/63 45.8 35.2 50.7 1.46 31.4 80/67 48.8 36.4 53.7 1.45 33.6 70 27.7 20.9 2.11 3.8 85/71 52.0 37.4 56.9 1.45 35.9 80 27.0 19.4 2.35 3.4 75/63 41.6 33.4 47.8 1.88 22.1 80/67 44.3 34.5 50.6 1.90 23.3 70 29.2 21.9 2.12 4.0 85/71 47.1 35.5 53.4 1.92 24.5 80 28.8 20.9 2.37 3.6 75/63 43.0 34.0 48.8 1.74 24.7 80/67 45.9 35.1 51.7 1.74 26.3 70 30.8 23.8 2.15 4.2 85/71 48.9 36.1 54.7 1.75 27.9 80 30.3 22.2 2.39 3.7 75/63 43.7 34.3 49.3 1.67 26.2 80/67 46.6 35.5 52.2 1.67 27.9 70 31.7 24.9 2.16 4.3 85/71 49.7 36.5 55.3 1.67 29.7 80 31.0 23.3 2.40 3.8 75/63 39.5 32.7 46.3 2.08 19.0 80/67 42.1 33.8 49.0 2.10 20.0 70 33.3 26.0 2.17 4.5 85/71 44.9 34.7 51.9 2.13 21.1 80 32.3 24.1 2.42 3.9 75/63 40.9 33.2 47.3 1.95 21.0 80/67 43.6 34.3 50.1 1.95 22.3 70 35.1 27.4 2.20 4.7 85/71 46.5 35.4 53.0 1.97 23.7 80 34.3 26.3 2.44 4.1 75/63 41.5 33.5 47.7 1.88 22.1 80/67 44.4 34.5 50.7 1.89 23.6 70 36.5 29.4 2.21 4.8 85/71 47.3 35.7 53.6 1.89 25.0 80 35.4 27.5 2.46 4.2 75/63 37.5 31.8 45.0 2.31 16.3 80/67 40.0 32.9 47.6 2.33 17.2 70 37.4 30.0 2.23 4.9 85/71 42.5 34.0 50.2 2.35 18.1 80 36.7 28.7 2.47 4.3 75/63 38.8 32.4 45.8 2.16 17.9 80/67 41.5 33.4 48.6 2.18 19.1 70 40.1 33.2 2.26 5.2 85/71 44.2 34.5 51.4 2.19 20.2 80 38.6 30.6 2.50 4.5 75/63 39.4 32.6 46.2 2.10 18.8 80/67 42.1 33.8 49.0 2.11 20.0 70 41.0 33.8 2.27 5.3 85/71 45.0 34.7 52.0 2.12 21.3 80 40.1 32.1 2.52 4.7 75/63 36.4 31.4 44.3 2.42 15.0 80/67 39.0 32.5 46.9 2.44 16.0 70 41.7 34.6 2.29 5.3 85/71 41.4 33.6 49.4 2.47 16.8 80 41.1 32.8 2.53 4.8 75/63 37.8 31.8 45.2 2.28 16.6 80/67 40.3 33.0 47.8 2.29 17.6 70 45.5 37.8 2.33 5.7 85/71 43.0 34.2 50.5 2.30 18.7 80 44.3 36.0 2.58 5.0 75/63 38.3 32.2 45.5 2.22 17.3 80/67 41.0 33.2 48.3 2.22 18.4 70 46.1 40.0 2.36 5.7 85/71 43.7 34.4 51.0 2.23 19.6 80 45.2 37.0 2.60 5.1 75/63 35.5 30.9 43.7 2.55 13.9 80/67 37.8 32.2 46.1 2.57 14.7 70 46.9 38.9 2.36 5.8 85/71 40.2 33.3 48.7 2.59 15.5 80 45.9 37.1 2.61 5.2 75/63 36.6 31.5 44.4 2.40 15.2 80/67 39.2 32.7 47.0 2.41 16.2 70 47.9 42.5 2.37 5.9 85/71 41.8 33.8 49.7 2.43 17.2 80 48.9 40.6 2.67 5.4 75/63 37.2 31.7 44.8 2.34 15.9 80/67 39.8 32.9 47.4 2.34 17.0 70 52.7 45.1 2.45 6.3 85/71 42.5 34.0 50.2 2.35 18.1 80 51.3 42.3 2.71 5.6 75/63 33.4 30.2 42.4 2.81 11.9 80/67 35.6 31.3 44.8 2.84 12.6 85/71 38.0 32.5 47.3 2.86 13.3 75/63 34.5 30.5 43.1 2.67 12.9 80/67 36.9 31.8 45.5 2.68 13.8 85/71 39.4 33.0 48.2 2.69 14.6 75/63 34.9 30.8 43.3 2.61 13.4 80/67 37.5 31.9 46.0 2.61 14.4 85/71 40.1 33.2 48.6 2.62 15.3 75/63 31.3 29.3 41.3 3.11 10.1 80/67 33.5 30.6 43.6 3.14 10.7 85/71 35.4 31.6 45.6 3.16 11.2 75/63 32.3 29.7 41.8 2.96 10.9 80/67 34.7 30.9 44.3 2.98 11.7 85/71 37.0 32.1 46.8 2.99 12.4 75/63 32.8 29.9 42.2 2.90 11.3 80/67 35.2 31.1 44.6 2.91 12.1 85/71 37.6 32.3 47.1 2.92 12.9
Total
Capacity
(MBTUH)
Sensible Capacity
(MBTUH)
Heat of Rejection (MBTUH)
Power
Input
(kW)
EER
Entering
Temp (F)
Water
Fluid
30*
40*
50
60
70
80
* Extended Range - Antifreeze required for entering fl uid
temperture at or below 45 Degrees F.
AHRI/ISO13256-1 certified per formance is rated at entering air conditions
of 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Tabulated unit performance does not include fan or pump power
corrections required for AHRI/ISO standard performance ratings.
Unit performance may be interpolated. Extrapolation is not allowed.
Ratings below 40°F are with a methanol solution.
Due to variations in installation, actual performance may vary from the
tabulated data. Performance contained herein are as a result of extensive testing by FHP and are not express warranties between the parties and may be changed at any time.
Continuous research and development to improve our products may result
in a change to the current design and specifications without notice.
Pressure
Flow
(GPM)
Drop
(FOH)
5 1.9 0.8
8 4.3 1.9
11 7.7 3.3
5 1.8 0.8
8 4.2 1.8
11 7.4 3.2
5 1.7 0.7
8 4.0 1.7
11 7.1 3.1
5 1.7 0.7
8 3.9 1.7
11 6.9 3.0
5 1.6 0.7
8 3.8 1.6
11 6.7 2.9
5 1.6 0.7
8 3.6 1.6
11 6.5 2.8
Engineering Submittal Sheet
Pressure
Drop
(PSI)
Entering
Air Temp
Total
Capacity
(F)
(MBTUH)
60 26.2 20.3 1.87 4.1
60 27.6 21.6 1.89 4.3
60 28.4 22.4 1.90 4.4
60 29.9 23.7 1.91 4.6
60 31.7 25.1 1.92 4.8
60 32.8 26.3 1.94 5.0
60 33.9 27.4 1.95 5.1
60 36.1 29.7 1.97 5.4
60 37.2 30.7 1.99 5.5
60 38.2 31.6 2.00 5.6
60 41.3 35.1 2.04 5.9
60 42.5 35.7 2.05 6.1
60 43.0 36.1 2.06 6.1
60 46.5 39.0 2.10 6.5
60 48.1 40.8 2.12 6.6
60 47.9 40.8 2.12 6.6
60 52.6 44.6 2.18 7.1
60 53.9 48.1 2.22 7.1
Heat of
Absorption
(MBTUH)
Power
Input (kW)
COP
19 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 20
i Series Model BP
Residential Geothermal Heat Pumps
BP048 (1600 CFM) Capacity Data
Entering
Fluid
Temp (F)
50
60
70
80
85
90
100
110
Water
Pressure
Flow
Drop
(GPM)
(FOH)
6 3.6 1.6
8 6 2.6
12 12.4 5.4
6 3.4 1.5
8 5.8 2.5
12 12 5.2
6 3.3 1.4
8 5.6 2.4
12 11.6 5.0
6 3.2 1.4
8 5.4 2.3
12 11.2 4.8
6 3.2 1.4
8 5.3 2.3
12 11 4.8
6 3.1 1.3
8 5.2 2.3
12 10.8 4.7
6 3 1.3
8 5.1 2.2
12 10.5 4.5
6 2.9 1.3
8 4.9 2.1
12 10.2 4.4
Pressure
Drop (PSI)
COOLING HEATING
Entering Air Temp
(db/wb) F
75/63 49.9 39.2 56.9 2.14 23.3 80/67 53.3 40.3 60.2 2.13 25.1 70 32.1 23.1 2.66 3.5 85/71 56.6 41.4 63.6 2.10 26.9 80 31.5 21.8 2.95 3.1 75/63 50.9 39.6 57.6 2.04 25.0 80/67 54.4 40.7 61.1 2.01 27.0 70 33.1 24.0 2.68 3.6 85/71 57.9 41.9 64.5 1.98 29.2 80 32.6 22.7 2.97 3.2 75/63 52.1 40.0 58.5 1.94 26.9 80/67 55.6 41.3 61.9 1.90 29.2 70 34.3 25.4 2.70 3.7 85/71 59.3 42.4 65.5 1.86 31.9 80 33.8 23.9 3.00 3.3 75/63 47.8 38.2 55.5 2.37 20.1 80/67 50.9 39.5 58.6 2.36 21.5 70 36.5 27.4 2.74 3.9 85/71 54.2 40.5 61.9 2.35 23.1 80 35.9 25.9 3.04 3.5 75/63 48.8 38.6 56.2 2.26 21.6 80/67 52.1 39.8 59.5 2.24 23.2 70 37.7 28.5 2.76 4.0 85/71 55.4 41.1 62.7 2.22 25.0 80 37.3 26.6 3.07 3.6 75/63 49.8 39.1 56.8 2.15 23.1 80/67 53.2 40.4 60.2 2.12 25.1 70 39.2 29.9 2.79 4.1 85/71 56.7 41.6 63.6 2.09 27.2 80 38.6 28.3 3.10 3.7 75/63 45.5 37.3 54.0 2.64 17.3 80/67 48.6 38.5 57.2 2.63 18.5 70 41.3 31.8 2.83 4.3 85/71 51.6 39.8 60.2 2.62 19.7 80 41.0 30.2 3.13 3.8 75/63 46.5 37.7 54.6 2.52 18.5 80/67 49.6 39.0 57.8 2.50 19.8 70 42.9 33.3 2.85 4.4 85/71 52.9 40.2 61.0 2.48 21.3 80 42.2 31.6 3.16 3.9 75/63 47.5 38.1 55.3 2.40 19.8 80/67 50.7 39.4 58.5 2.38 21.3 70 44.6 35.3 2.88 4.5 85/71 54.1 40.7 61.8 2.35 23.1 80 43.8 33.2 3.19 4.0 75/63 43.3 36.4 52.7 2.93 14.8 80/67 46.2 37.7 55.6 2.93 15.8 70 47.0 36.9 2.91 4.7 85/71 49.2 38.8 58.7 2.93 16.8 80 45.9 34.9 3.22 4.2 75/63 44.2 36.7 53.3 2.81 15.7 80/67 47.2 38.1 56.2 2.80 16.9 70 48.5 38.6 2.93 4.8 85/71 50.4 39.2 59.4 2.78 18.1 80 47.7 37.0 3.26 4.3 75/63 45.2 37.1 53.8 2.69 16.8 80/67 48.3 38.4 57.0 2.67 18.1 70 50.6 41.0 2.96 5.0 85/71 51.5 39.7 60.1 2.64 19.5 80 49.9 38.3 3.28 4.5 75/63 42.1 36.0 52.0 3.09 13.6 80/67 45.0 37.1 55.0 3.09 14.5 70 52.1 42.1 2.98 5.1 85/71 47.8 38.5 57.8 3.09 15.5 80 51.3 40.1 3.31 4.5 75/63 43.0 36.3 52.5 2.97 14.5 80/67 45.9 37.6 55.5 2.96 15.5 70 54.8 44.9 3.01 5.3 85/71 49.0 38.8 58.5 2.94 16.6 80 53.4 42.2 3.34 4.7 75/63 44.0 36.6 53.1 2.85 15.5 80/67 47.0 37.9 56.2 2.83 16.6 70 57.0 46.8 3.03 5.5 85/71 50.1 39.2 59.2 2.80 17.9 80 55.8 44.4 3.37 4.9 75/63 41.0 35.4 51.5 3.26 12.6 80/67 43.7 36.8 54.2 3.26 13.4 70 57.9 47.6 3.04 5.6 85/71 46.7 37.9 57.2 3.26 14.3 80 56.9 45.4 3.38 4.9 75/63 41.8 35.8 51.9 3.14 13.3 80/67 44.7 37.1 54.8 3.13 14.3 70 60.5 50.2 3.06 5.8 85/71 47.6 38.4 57.7 3.11 15.3 80 59.5 47.8 3.41 5.1 75/63 42.8 36.1 52.4 3.01 14.2 80/67 45.7 37.5 55.3 2.99 15.3 70 63.3 53.0 3.09 6.0 85/71 48.8 38.6 58.5 2.97 16.4 80 61.9 50.4 3.44 5.3 75/63 38.7 34.4 50.3 3.63 10.7 80/67 41.3 35.8 52.9 3.63 11.4 85/71 43.9 37.1 55.6 3.63 12.1 75/63 39.5 34.8 50.7 3.50 11.3 80/67 42.1 36.2 53.3 3.49 12.1 85/71 44.9 37.4 56.1 3.48 12.9 75/63 40.3 35.1 51.1 3.38 11.9 80/67 43.1 36.5 53.9 3.36 12.8 85/71 46.0 37.8 56.8 3.34 13.8 75/63 36.2 33.5 49.0 4.02 9.0 80/67 38.7 34.9 51.6 4.03 9.6 85/71 41.1 36.2 54.1 4.03 10.2 75/63 37.0 33.8 49.4 3.90 9.5 80/67 39.5 35.2 51.9 3.89 10.1 85/71 42.2 36.5 54.7 3.88 10.9 75/63 37.7 34.2 49.7 3.77 10.0 80/67 40.3 35.5 52.3 3.76 10.7 85/71 43.1 36.9 55.2 3.74 11.5
Total
Capacity
(MBTUH)
Sensible Capacity
(MBTUH)
Heat of Rejection (MBTUH)
Power
Input
(kW)
EER
Entering
Temp (F)
Water
Fluid
30*
40*
50
60
70
80
* Extended Range - Antifreeze required for entering fl uid
temperture at or below 45 Degrees F.
AHRI/ISO13256-1 certified per formance is rated at entering air conditions
of 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Tabulated unit performance does not include fan or pump power
corrections required for AHRI/ISO standard performance ratings.
Unit performance may be interpolated. Extrapolation is not allowed.
Ratings below 40°F are with a methanol solution.
Due to variations in installation, actual performance may vary from the
tabulated data. Performance contained herein are as a result of extensive testing by FHP and are not express warranties between the parties and may be changed at any time.
Continuous research and development to improve our products may result
in a change to the current design and specifications without notice.
Pressure
Flow
(GPM)
Drop
(FOH)
6 2.6 1.1
8 4.3 1.9
12 9.0 3.9
6 2.5 1.1
8 4.2 1.8
12 8.6 3.7
6 2.4 1.0
8 4.0 1.7
12 8.3 3.6
6 2.3 1.0
8 3.9 1.7
12 8.1 3.5
6 2.2 1.0
8 3.8 1.6
12 7.8 3.4
6 2.2 0.9
8 3.6 1.6
12 7.5 3.3
Engineering Submittal Sheet
Pressure
Drop
(PSI)
Entering
Air Temp
Total
Capacity
(F)
(MBTUH)
60 32.7 24.6 2.41 4.0
60 33.8 25.6 2.43 4.1
60 35.3 26.8 2.45 4.2
60 37.2 28.8 2.48 4.4
60 38.4 29.9 2.49 4.5
60 40.0 31.6 2.52 4.7
60 42.1 33.5 2.55 4.8
60 43.8 35.1 2.57 5.0
60 45.6 37.3 2.60 5.1
60 47.7 38.7 2.62 5.3
60 49.5 40.6 2.64 5.5
60 51.8 42.8 2.67 5.7
60 53.1 44.1 2.68 5.8
60 55.5 46.4 2.70 6.0
60 58.2 49.1 2.72 6.3
60 58.9 49.8 2.73 6.3
60 61.7 52.5 2.74 6.6
60 64.9 55.6 2.76 6.9
Heat of
Absorption
(MBTUH)
Power
Input (kW)
COP
20 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 21
i Series Model BP
Residential Geothermal Heat Pumps
Antifreeze Correction
Antifreeze Type Antifreeze %
Total Cap. Sens. Cap Power Htg. Cap Power
Water 0 1.000 1.000 1.000 1.000 1.000 1.000
5 0.997 0.997 1.004 0.989 0.997 1.06
10 0.994 0.994 1.006 0.986 0.995 1.125
Propylene Glycol
Methanol
Ethanol
15 0.990 0.990 1.009 0.978 0.988 1.19 25 0.983 0.983 1.016 0.960 0.979 1.3
5 0.997 0.997 1.003 0.990 0.997 1.06 10 0.996 0.996 1.005 0.979 0.993 1.1 15 0.994 0.994 1.008 0.970 0.990 1.14
5 0.998 0.998 1.002 0.981 0.994 1.16 10 0.996 0.996 1.004 0.960 0.988 1.23 15 0.992 0.992 1.006 0.944 0.983 1.280 25 0.986 0.986 1.009 0.917 0.974 1.4
EWT 90 Deg.F EWT 30 Deg. F
Engineering Submittal Sheet
Cooling Heating
WPD Correction
Factor EWT 30 °F
Ethylene Glycol
5 0.997 0.997 1.003 0.993 0.998 1.06 10 0.995 0.995 1.004 0.986 0.996 1.12 15 0.992 0.992 1.005 0.980 0.993 1.19 25 0.988 0.988 1.009 0.970 0.990 1.33 30 0.985 0.985 1.012 0.965 0.987 1.4
21 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 22
i Series Model BP
Residential Geothermal Heat Pumps
Casing Radiated Sound Power - Octave Band Sound Power Levels dB, re 10-12 Watts
Model Load
Cooling Full 66 58 51 51 45 41 35 67 56
BP012
BP018
BP024
BP030
BP036
BP042
BP048
Heating Full 71 61 51 51 45 40 34 71 59
FAN Only 6156515145393363 55 Cooling Full 71 62 53 49 47 45 41 72 59 Heating Full 76 66 59 56 55 52 47 77 65
FAN Only 5048494235302454 48 Cooling Full 63 55 54 49 42 37 28 65 55 Heating Full 71 56 54 50 44 41 32 72 58
FAN Only 5552534942382759 54 Cooling Full 67 58 56 52 45 38 28 68 58 Heating Full 67 58 66 52 46 39 30 68 58
FAN Only 5855565245382662 56 Cooling Full 65 62 62 63 58 52 43 70 66 Heating Full 67 63 63 64 59 52 44 71 67
FAN Only 6562626358524370 66 Cooling Full 71 58 57 55 46 46 39 71 60 Heating Full 73 58 57 55 47 47 39 73 61
FAN Only 5655575546463762 59 Cooling Full 72 63 58 57 51 43 38 73 62 Heating Full 73 63 58 57 52 44 37 74 62
FAN Only 6061575751433466 60
125 250 500 1000 2000 4000 8000 Overall
Center Frequency - Hz
Engineering Submittal Sheet
Overall (dBA)
Tested according to AHRI-260 standard for ISO-13256
WLHP condition at rated water and air fl ow rate
Overall calculated using 125-8000 Hz octave bands.
22 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 23
i Series Model BP
Residential Geothermal Heat Pumps
Ducted Discharge Sound Power - Octave Band Sound Power Levels dB, re 10-12 Watts
Model Load
Cooling Full 71 61 58 56 51 51 48 72 62
BP012
BP018
BP024
BP030
BP036
BP042
BP048
Heating Full 71 62 59 58 50 51 48 72 63
FAN Only 7161617059514874 71 Cooling Full 69 52 59 57 50 48 39 70 61 Heating Full 70 53 60 57 49 48 39 71 62
FAN Only 6251595849483965 61 Cooling Full 70 55 63 52 51 54 43 71 62 Heating Full 73 56 63 54 50 53 42 74 63
FAN Only 6655635250534368 62 Cooling Full 70 55 63 52 51 54 43 71 62 Heating Full 73 56 63 54 50 53 42 74 63
FAN Only 6655635250534368 62 Cooling Full 78 64 71 60 59 62 55 79 71 Heating Full 79 67 71 61 58 61 55 80 71
FAN Only 7966716058615580 71 Cooling Full 73 58 66 57 56 56 50 74 66 Heating Full 75 59 66 56 56 56 49 76 66
FAN Only 7359665756564974 66 Cooling Full 75 62 66 59 58 61 53 76 68 Heating Full 75 62 66 58 56 60 52 76 67
FAN Only 7663665957605377 68
125 250 500 1000 2000 4000 8000 Overall
Center Frequency - Hz
Engineering Submittal Sheet
Overall (dBA)
Tested according to AHRI-260 standard for ISO-13256
WLHP condition at rated water and air fl ow rate
Overall calculated using 125-8000 Hz octave bands.
23 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 24
i Series Model BP
Residential Geothermal Heat Pumps
WARNING:
These electric heaters can only be installed in factory default blower confi guration only.
Field Installed Accessory - Internally Mounted Electric Heat Kits
Part Number Kilowatt Heater - 208/230V
7738003204 Electric Heat - 3.6/4.8 kW 7738003205 Electric Heat - 7.8/9.6 kW 7738003206 Electric Heat - 10.8/14.4 kW 7738003207 Electric Heat - 14.4/19.2 kW
It is recommended to use a seven (7) conductor
cable for thermostat interface.
BP012 BP018 BP024 BP030 BP036 BP042 BP048

Engineering Submittal Sheet
Availability per Unit



Field Installed Accessory - Pump/Valve Relay Kit
Part Number
7738003204
BP012 BP018 BP024 BP030 BP036 BP042 BP048
VT HZ VT HZ VT HZ VT HZ VT HZ VT HZ VT HZ

Field Installed Accessory - Swivel Connector Kit (two connectors per package)
BP012 BP018 BP024 BP030 BP036 BP042 BP048
Order
Number
7738003200
7738003201
Type &
Size
Male 3/4"
NPT
Male 1"
NPT
VT HZ VT HZ VT HZ VT HZ VT HZ VT HZ VT HZ
Where Used


24 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 25
Engineering Submittal Sheet
i Series Model BP
Residential Geothermal Heat Pumps
Field Installed Accessory - SmartStart Assist Kit
Part Number
8733920430
Field Installed Accessory - Duct Mounted Electric Heaters 208/230V
Nominal
BTUH
18000 7738002745 24000 7738002746 7738002747 N/A N/A 800 13.75 x 13.75 14 x 14 30000 7738002748 7738002749 N/A N/A 1000 15.75 x 15.75 16 x 16 36000 7738002748 7738002749 N/A N/A 1200 15.75 x 15.75 16 x 16 42000 7738002747 7738002751 7738002752 N/A 1400 17.75 x 17.75 18 x 18 48000 7738002747 7738002751 7738002752 N/A 1600 17.75 x 17.75 18 x 18 60000 7738002747 7738002751 7738002752 7738002753 2000 17.75 x 17.75 18 x 18 70000 7738002747
BP012 BP018 BP024 BP030 BP036 BP042 BP048
VT HZ VT HZ VT HZ VT HZ VT HZ VT HZ VT HZ

Order #
5 kW 10 kW 15 kW 20 kW
N/A N/A N/A 600 13.75 x 13.75 14 x 14
7738002751 7738002752 7738002753 2200 17.75 x 17.75 18 x 18
Nominal
CFM
Duct Flange Connection in
Inches
Nominal Dimension in
Inches
Duct mounted heaters are only available in
single phase 208/230 V. Please refer to Manufacturer’s Installation and Operation Manual for proper installation and guidelines. It is recommended to use a seven (7) conductor cables for thermostat interface. It is required for the duct mounted heater to have an independent power supply. In fi berglass duct systems, a metal sleeve
MUST be used as an insert and support to the heater.
25 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 26
Engineering Submittal Sheet
i Series Model BP
Residential Geothermal Heat Pumps
Field Installed Accessory - Stainless Steel Hose Kits
Options Option 1 Option 2 Option 3** Option 4**,*** Option 5**, *** Option 6**, ***
Hose Size
(Length,
Diameter)
12 Inch
1/2" L T111H02121
24 Inch
3/4" S T111H03241 T111H03242 T111H03243 T111H03244 T111H03245 T111H03246 1" L T111H04241 T111H04242 T111H04243 T111H04244 T111H04245 T111H04246 1" S T111H04241 T111H04242 T111H04247 T111H04248 T111H04249 T111H04240 1 - 1/4" S T111H05241 T111H05242 T111H05243 T111H05244 T111H05245 T111H05246 1 - 1/2" L T111H06241 T111H06242 T111H06243 T111H06244 T111H06245 T111H06246 1 - 1/2" S T111H06241 T111H06242 T111H06247 T111H06248 T111H06249 T111H06240 2" S T111H08241
36 Inch
3/4" S T111H03361 T111H03362 T111H03363 T111H03364 T111H03365 T111H03366 1" L T111H04361 T111H04362 T111H04363 T111H04364 T111H04365 T111H04366 1" S T111H04361 T111H04362 T111H04367 T111H04368 T111H04369 T111H04360 1 - 1/4" S T111H05361 T111H05362 T111H05363 T111H05364 T111H05365 T111H05366 1 - 1/2" L T111H06361 T111H06362 T111H06363 T111H06364 T111H06365 T111H06366 1 - 1/2" S T111H06361 T111H06362 T111H06367 T111H06368 T111H06369 T111H06360 2" S T111H08361
* All Hose Kis include S/R ported ball valves with swivel and P/T port. ** 'L' and 'S' only apply to kit options 3 through 6 *** GMP's are required for hose kits in options 3-6
Hoses Only with
Swivel
Part # Part # Part # Part # Part # Part #
Hose Kit Hoses with
Ported Ball Valves,
Swivel and One P/T*
T111H02122 T111H02123 T111H02124 T111H02125 T111H02126
T111H08242 T111H08243 T111H08244 T111H08245 T111H08246
T111H08362 T111H08363 T111H08364 T111H08365 T111H08366
Hose Kit with
Automatic Flow Valve
(AFV)*
Hose kit with AFV,
Y-Strainer & Blow
Down Valve*
Hose Kit with AFV
and Electric Valve*
Hose Kit with AFV,
Y-Strainer, BDV and
Electric Valve*
Hose Kit Flow Rates by Size
Please see Technical Service Bulletin: Heat Pump Hose Kits – Water Flow Rates. This document is located at www.bosch-climate.us under Support Center > Downloads > Downloads for Bosch Products > Service Bulletins.
Bosch Thermotechnology Corp.
26 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Page 27
i Series Model BP
Residential Geothermal Heat Pumps
Field Installed Accessory - Bosch Connected Control Wi-Fi Thermostat
Description Part Number Heat Cool Humidity
Bosch Connected Control (BCC100) 8-733-948-009
Specifi cations
Main Menu
Wi-Fi / Cloud Access
Indicator
Engineering Submittal Sheet
42 Yes
System Mode /
Status
Fan Mode /
Status
Humidity
Setup
Current Space
Humidity
3.07" (78 mm)
Current Room
Temperature
5.20" (132 mm)
Set-Points
Current
Schedule
Adjust
Temperature
Set-Points
0.98" (25 mm)
0.67" (17 mm)
5 Inch Touch Screen 854 x 480 Pixels — 7 Relay Outputs (Terminals) G, Y1, Y2, W1, W2, O/B, H/dH — 1 Data Input (Pulse signals from Bosch WSHP) — Displays Bosch Water Source Heat Pump Fault Messages — Wi-Fi (802.11a/b/g/n) 2.4GHz (not compatible with 5GHz) — FCC and IC Certification
5 Year Limited Warranty (see website for details:
https://www.bosch-climate. us/products-bosch-thermotechnology/thermostats-and-controls/residential­thermostats-controls/bcc100.html
)
Compatibility
Conventional (Gas, Oil, Electric): Up to 2 Heat / 2 Cool — Heat Pump (O/B to energize reversing valve in cool/heat): Up to 4 Heat / 2 Cool — Supports up to 1 Accessory Unit: Humidifier or Dehumidifer (not provided by
Bosch)
Unit Modes: Heat, Cool, Auto, Off, Emergency Heat — Fan Modes: Auto, On, Circulate — Supports 2 Transformer Systems (Rh and Rc) — C-Wire Required for Installation — Supports Active and Passive Dehumidifi cation without the need for external
relays, such as Bosch Water Source Heat Pump products equipped with a Hot Gas Reheat Coil and/or ECM motor
27 of 27
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760608301 D | 11.2018
Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL
Bosch Thermotechnology Corp.
Tel: 1-866-642-3198 Fax: 1-603-965-7581 www.boschheatingandcooling.com
Loading...