Bonnet B1AC-2PLSM User Manual

BONNET GRANDE CUISINE Registered office:
Rue des Frères Lumière - Z.I Mitry Compans
OPTIMUM,
F-77292 MITRY MORY Cedex
STANDS
B1AC74PTSM / B1AC78PTSM / B1AC79PTSM / B1AC712PTSM / B1AC716PTSM
PLINTHS
B1AC7PLSMD / B1AC7PLSMG / B1AC-2PLSM
Intermediate rails
Stand
End plinth
Front trimming plinth
MASONRY BASES
* Requested "full", entirely tiled, with a forward slope of 1 cm/m maximum.
STANDS
* This enables the installation of any horizontal cooking equipment on a masonry base. * The range is identical to the standard base range (height reduced to 90 mm). * Characteristics:
- All stainless steel construction.
- Screw legs with anti-skid "pad", adjustable within + or – 10 mm.
- Equipped with a front stainless steel plinth delivered with screws and junction element to hide the join and forming a deflector against washing water.
- Supplied with intermediate rails to assembly of multiple appliances on a same stand.
Kind of stands Number of appliances / width
- Stands 400mm : 1 x 400
- Stands 800mm : 1 x 800 or 2 x 400
- Stands 900mm : 1 x 900
- Stands 1200mm : 3 x 400 or 1 x 800 + 1 x 400
- Stands 1600mm : 2 x 800 or 4 x 400 or 1 x 800 + 2 x 400
PLINTHS FOR NEUTRAL TOP ON TECHNICAL COMPARTMENT 200MM WIDE
* Equipped with a front stainless steel plinth delivered with screws and junction element to hide the join and forming a deflector against washing
water.
END PLINTHS
* An end kit must be used for each visible end.
STANDARDS
IP 25 and IK 9: Protection indexes. XP U 60-010: Hygiene.
: Compliance with standards
BONNET GRANDE CUISINE
plinth
Stand
Registered office:
Rue des Frères Lumière - Z.I Mitry Compans F-77292 MITRY MORY Cedex
B1AC74PTSM / B1AC78PTSM / B1AC79PTSM / B1AC712PTSM /
B1AC716PTSM
B1AC7PLSMD / B1AC7PLSMG / B1AC-2PLSM
STAND CODE DIMENSIONS (mm)
B1AC74PTSM B1AC78PTSM B1AC79PTSM B1AC712PTSM B1AC716PTSM
Possibility to lay pipes on front part
Aeration
Appliance
Trimming
Height of base from front
Width 400 800 900 1200 1600
PLINTH CODE
B1AC7PLSMG B1AC7PLSMD B1AC-2PLSM
Side of the end Left Right - Largeur plinthe - - 200
DIAGRAM ON MASONRY BASES
Wall
Stove depth Stove depth Stove depth
Centrally
Am
Finished
Full tiled base Full tiled base Full tiled base
1 cm/m maximum slope 1 cm/m maximum slope 1 cm/m maximum slope
height with
tiled front
(front view)
Lf: Stove width
Ls
Full tiled base
DIMENSIONS (mm)
D
epth of base as wall-installed : Am Depth of base as central-installed: Ac Length of base: Ls Lf - 50 Height as completed, tiled on front side 110
Ac
710
1420
(side view)(side view)
Finished
height with
tiled front
Non contractual Document 01/2012 edition – 3BE B1AC7_PTSM