Boneco U330 User Manual

U330
MANUAL
READ AND SAVE THESE INSTRUCTIONS
Instructions for use 3
Instructions d’utilisation 14
Instrucciones de uso 25
BONECO U330
3
en
4
OVERVIEW AND PART NAMES
en
1
1
6
2
2
3
3
5
4
5
7
6
8
7
9
8
1 Cover 2 Nozzle 3 Flue 4 Main switch / controller 5 Cleaning brush 6 A250 AQUA PRO 7 Fragrance container 8 Power supply
5
TABLE OF CONTENTS
Introduction 6
Introduction 6 A250 AQUA PRO 6 Items included 6
Start-up 7
Preparation of the A250 AQUA PRO 8
A250 AQUA PRO preparation 8 On water hardness 8 Determining water hardness 8
The right location 9
The right location 9
Functions and indicators 9
Water level 9 Fragrance container 9
Notes on care 10
Care instructions 10 Cleaning agent 10
Cleaning and descaling 11
Descaling 11 Removing mineral deposits 12
en
Technical data 13
6
INTRODUCTION
en
INTRODUCTION
Congratulations on your purchase of the BONECO U330. This high-performance humidifier keeps the humidity at a comfortable level at all times. No longer will you have to contend with itchy eyes, dry skin and dry mucous membranes. This helps make you and your family less susceptible to colds and other infectious diseases.
Thanks to its fully automated operation, you don’t have to spend any more time thinking about the ideal level of humidity. The BO NECO U330 switches itself off automati­cally as soon as the optimal value is attained.
You will not want to give up your newly gained com­fort.
A250 AQUA PRO
Please refer to the enclosed manual for putting the A250 AQUA PRO into operation.
ITEMS INCLUDED
BONECO U330 “A7417 EZCal” cleaning and
A250 AQUA PRO
descaling powder
Water hardness test strips
7
START-UP
1 2
Fill the tank with cold tap water. Warning: Do not exceed the maximum fill level.
4
5
en
3
Connect the BONECO U330 to the power outlet.
Use the control knob to switch on the BONECO U330.
Set the intensity of the mist you want.
8
PREPARATION OF THE A250 AQUA PRO
en
A250 AQUA PRO PREPARATION
1. Remove the packaging of the BONECO A250 AQUA
PRO.
2. Rinse the A250 AQUA PRO for 2 minutes under cold running water.
3. Screw the A250 AQUA PRO to the BONECO U330.
ON WATER HARDNESS
The BONECO U330 is supplied with an A250 AQUA PRO. The granulate contained in it filters the lime out of the tap water so that it is not released into the room air. Hard tap water accelerates saturation of the granulate so that the A250 AQUA PRO must be replaced earlier.
DETERMINING WATER HARDNESS
1. Dip the enclosed test strip into a glass of cold tap water for 1 second.
2. Read the water hardness after one minute.
3. Refer to the table to determine the duration of effect of the A250 AQUA PRO:
= 6 mont hs = 6 mont hs = 5 mont hs = 4 mont hs = 3 mont hs = 2 mont hs
Dispose of the saturated A250 AQUA PRO with your regu­lar household waste.
The A250 AQUA PRO should not be used longer than specified. White dust around the appliance is a sure indi­cation that the A250 AQUA PRO has run its course. You can obtain replacements from your BONECO specialist dealer or our online store at www.shop.boneco.us
9
THE RIGHT LOCATION
THE RIGHT LOCATION
The BONECO U330 releases more than half a liter of wa­ter into the air per hour. This makes it important to set up the appliance in the right location.
Do not place the BONECO U330 directly on the floor,
since the moisture from the mist can damage floor surfaces such as parquet or delicate carpeting.
• Make sure that the appliance stands about 1 ft (30 cm) away from the closest wall.
• The unit should be placed in an elevated position, e.g. on a table, chest of drawers, etc.
• Do not direct the mist toward the wall, plants, furniture or other objects in order to prevent water condensation from damaging them. Maintain a distance of at least 20 inches (50 cm).
FUNCTIONS AND INDICATORS
WATER LEVEL
The LED lighting on the switch indicates the operating status and water level.
Blue (lights up): The appliance is switched on and in operation. A sufficient amount of water is in the tank.
Red (blinking): The appliance is switched on, but the water tank is empty. Switch off the appliance or refill the tank with fresh water.
Blue (fading): The ideal humidity of ~ 60 percent is reached. The unit continues to work automatically until this value is achieved.
No display: The appliance is switched off or discon­nected from the power outlet.
en
FRAGRANCE CONTAINER
Commercially available fragrances can be inserted into the fragrance container on the rear side.
1. Press down on the fragrance container to unlock the drawer.
2. Sprinkle the cotton insert in the drawer with the fra­grance of your choice.
Never add the fragrance directly to the water tank;
doing so will damage the BONECO U330 and void the warranty!
10
NOTES ON CARE
en
CARE INSTRUCTIONS
With increasing time and use, the performance of the A250 AQUA PRO decreases. The inside of the BONECO U330 becomes coated with limescale. Stagnant water can also impair cleanliness and lead to unpleasant odors.
This means regular maintenance and cleaning is neces­sary to ensure clean and unimpaired operation.
Always unplug the unit from the power outlet before
cleaning. Failure to do so can result in electric shock and pose the risk of severe or fatal injury!
CLEANING AGENT
Clean the housing of the BONECO U330 with a soft cloth. Use warm tap water with a small amount of dishwashing detergent.
Interval* Task
Daily Check the water level; add water if necessary
After 1 week without operation Empty and clean the BONECO U330
Every 2 weeks Clean and descale the water tank
Every 2 to 6 months Replacing the A250 AQUA PRO
* Effective time intervals vary depending on air and water quality and the length of operation.
For this reason, the information here should be viewed as a recommendation.
11
CLEANING AND DESCALING
DESCALING
If stubborn limescale deposits form at the bottom of the BONECO U330, the appliance must also be descaled in addition to the cleaning. For this process, use the pro­vided “EZCal” descaling agent. You can get replacement parts at your BONECO specialist dealer or at the online store under shop.boneco.us
1. Disconnect the BONECO U330 from the power out­let.
The unit must always be unplugged from the power
outlet before draining it. Failure to do so can result in electric shock and pose the risk of severe or fatal injury!
2. Empty the water tank.
Tip the long side of the BONECO U330 towards the
sink (with the viewing window facing down). This prevents water from getting into the air outlet and damaging the unit.
3. Remove the A250 AQUA PRO.
4. Mix 1 bag of EZCal with 32 oz. (0.5 liters) of water and pour the mixture into the water tank, one half to the left and right each.
en
5. Wait a few hours to allow the EZCal mixture to take effect.
6. Clean the BONECO U330 with a dish brush.
7. Rinse the inside of the water tank with fresh tap wa­ter.
8. Reinsert the A250 AQUA PRO.