1 Cover 2 Nozzle 3 Flue 4 Main switch / controller 5 Cleaning brush 6 A250 AQUA PRO 7 Filter 8 Fragrance container 9 Power supply
5
TABLE OF CONTENTS
Overview and part names 4
Introduction 6
Introduction 6 A250 AQUA PRO 6 Items included 6
Start-up 7
The right location 8
The right location 8
Functions and indicators 8
Water level 8 Fragrance container 8
Notes on care 9
Care instructions 9 Cleaning agent 9
Cleaning and descaling 10
Descaling 10 Removing mineral deposits 11
Replacing the A250 AQUA PRO 12
Replacing THE A250 AQUA PRO 12 Filter function 13 Cleaning the filter 13
en
Cleaning the filter 13
Technical data 14
6
INTRODUCTION
en
INTRODUCTION
Congratulations on your purchase of the BONECO U300. This high-performance humidifier keeps the humidity at a comfortable level at all times. No longer will you have to contend with itchy eyes, dry skin and dry mucous membranes. This helps make you and your family less susceptible to colds and other infectious diseases.
You will not want to give up your newly gained com­fort.
A250 AQUA PRO
Please refer to the enclosed manual for putting the A250 AQUA PRO into operation.
ITEMS INCLUDED
BONECO U300 “A7417 EZCal” cleaning and
descaling powder
A250 AQUA PRO
7
START-UP
1 2
Fill the tank with cold tap water. Warning: Do not exceed the maximum fill level.
4
5
en
3
Connect the BONECO U300 to the power outlet.
Use the control knob to switch on the BONECO U300.
Set the intensity of the mist you want.
8
THE RIGHT LOCATION
en
THE RIGHT LOCATION
The BONECO U300 releases more than half a liter of wa­ter into the air per hour. This makes it important to set up the appliance in the right location.
Do not place the BONECO U300 directly on the floor,
since the moisture from the mist can damage floor surfaces such as parquet or delicate carpeting.
• Make sure that the applia nce stands about 30 centime­ters (one foot) away from the closest wall.
• Do not direct the mist toward the wall, plants, furniture or other objects in order to prevent water condensation from damaging them. Maintain a distance of at least 50cm (20 inches).
FUNCTIONS AND INDICATORS
WATER LEVEL
The LED lighting on the switch indicates the operating status and water level.
Blue: The appliance is switched on and in operation. A sufficient amount of water is in the tank.
Red: The appliance is switched on, but the water tank is empty. Switch off the appliance or refill the tank with fresh water.
No display: The appliance is switched off or discon­nected from the power outlet.
FRAGRANCE CONTAINER
Commercially available fragrances can be inserted into the fragrance container on the rear side.
1. Press down on the fragrance container to unlock the drawer.
2. Sprinkle the cotton wadding in the drawer with the fragrance of your choice.
Never add the fragrance directly to the water tank;
doing so will damage the BONECO U300 and void the warranty!
9
NOTES ON CARE
CARE INSTRUCTIONS
With increasing time and use, the performance of the A250 AQUA PRO decreases. The inside of the BONECO U300 becomes coated with limescale. Stagnant water can also impair cleanliness and lead to unpleasant odors.
This means regular maintenance and cleaning is neces­sary to ensure clean and unimpaired operation.
Always unplug the unit from the power outlet before
cleaning. Failure to do so can result in electric shock and pose the risk of severe or fatal injury!
CLEANING AGENT
Clean the housing of the BONECO U300 with a soft cloth. Use warm tap water with a small amount of dishwashing detergent.
Interval* Task
Daily Check the water level; add water if necessary
After 1 week without operation Empty and clean the BONECO U300
Every 2 weeks Clean and descale the water tank
Every 2 to 6 months Replacing the A250 AQUA PRO
* Effective time intervals vary depending on air and water quality and the length of operation.
For this reason, the information here should be viewed as a recommendation.
en
10
CLEANING AND DESCALING
en
DESCALING
If stubborn limescale deposits form at the bottom of the BONECO U300, the appliance must also be descaled in addition to the cleaning. For this process, use the pro­vided “EZCal” descaling agent. You can get replacement parts at your BONECO specialist dealer or at the online store under shop.boneco.us
1. Disconnect the BONECO U300 from the power out­let.
The unit must always be unplugged from the power
outlet before draining it. Failure to do so can result in electric shock and pose the risk of severe or fatal injury!
2. Empty the water tank.
Tip the long side of the BONECO U300 towards the
sink (with the viewing window facing down). This prevents water from getting into the air outlet and damaging the unit.
3. Remove the A250 AQUA PRO.
4. Mix 1 bag of EZCal with 1 liter (a quarter gallon) of warm water and pour the mixture into the water tank.
5. Wait a few hours to allow the EZCal mixture to take effect.
6. Clean the BONECO U300 with a dish brush.
7. Rinse the inside of the water tank with fresh tap wa­ter.
8. Reinsert the A250 AQUA PRO.
11
CLEANING AND DESCALING
REMOVING MINERAL DEPOSITS
Mineral deposits on the membrane can be removed using the yellow cleaning brush attached to the cover of the BONECO U300.
Never clean the membrane using sharp objects or
aggressive cleaning agents; doing so can damage the BONECO U300 and voids the warranty!
en
12
REPLACING THE A250 AQUA PRO
en
REPLACING THE A250 AQUA PRO
The A250 AQUA PRO must be replaced every 2 to 6 months. In cases of very hard water, it may have to be re­placed sooner. White dust around the appliance is a sure indication that the A250 AQUA PRO has run its course.
The new A250 AQUA PRO is ready for use immediately. Please refer to the enclosed manual for putting the A250 AQUA PRO into operation.
The used A250 AQUA PRO can be disposed of with your regular household waste.