Boneco S200 User Manual

S200
MANUAL
READ AND SAVE THESE INSTRUCTIONS
Instructions for use 3
Mode d’emploi 11
Instrucciones de uso 19
INSTRUCTIONS FOR USE
3
en
4
ITEMS INCLUDED AND TECHNICAL DATA
en
ITEMS INCLUDED
BONECO S200
TECHNICAL DATA
Mains voltage 120 V/ 60 Hz
Power consumption 145 W / 285 W
Humidity output 1.9 gal/day (300 g/h)
For rooms up to 430 sq f t (40 m
Water capacity 0.8 gal (3.0 liters)
Dimensions L×W×H 12.4 ×6.8 ×11 in. (316 ×172 × 281 mm)
Weight (empty) 5.5 lb (2.5 kg)
Operation noise level < 35 dB(A)
System Steamer
* Subject t o change
*
1 × “EZCal” descaling powder
2 × anti-mineral pad Printed quick star t guide
2
)
5
OVERVIEW AND PART NAMES
1
2
en
3
1 Water tank inspection glass 2 Output regulator 3 Steam outlet 4 Air inlet
4
6
PUTTING INTO OPERATION
en
1
Place the BONECO S200 on a stable surface.
4
2 3
Place the included anti-mineral pad on the heating plate.
5 6
Fill the water tank with cold tap water.
Plug the power cord into a power outlet.
Switch on the BONECO S200 with the output regulator.
Select level 1 or level 2 for the steam output.
7
HANDLING
SWITCHING ON AND OFF
The BONECO S200 is operated manually. The appliance will run until the control knob is moved to the “0” position.
If the water tank is empty, automatic shut-off prevents the appliance from overheating or becoming damaged.
1. Switch on the BONECO S200 by moving the control knob from the “0” position to the “I” position.
2. Increase the humidity output by moving the control knob to the “II” position.
3. Switch off the appliance once the desired humidity has been reached.
en
DISPLAY DURING OPERATION
The LED ring on the control knob indicates the operat­ing state.
Blue (constant): The appliance is functioning normally; there is water in the tank.
Red (constant): The appliance is switched on. However, the humidifying function has been switched off automati­cally because the water tank is empty.
Blue (pulsing): Cleaning mode is active.
8
CLEANING
en
SAFETY INSTRUCTIONS
Always unplug the BONECO S200 before you start
cleaning it! Failure to do so can result in electric shock and fatal injury!
Do not use alcohol or corrosive cleaning agents for
cleaning.
CLEANING THE HOUSING
In most cases, a dry cloth can be used for cleaning. If stubborn dirt is present, clean the housing using a damp cloth. Add a small amount of dishwashing detergent to the water. Household cloths and window cleaners can also be used.
REPLACING THE ANTI-MINERAL PAD
The anti-mineral pad absorbs lime in the water so that the heating plate does not become coated in limescale as quickly. This allows the BONECO S200 to function optimally at all times and descaling is required less fre­quently.
Over time, the anti-mineral pad becomes hard and less effective due to the absorbed lime.
Check the anti-mineral pad after each cleaning. Replace the anti-mineral pad if it feels hard and rigid. You can find replacements at your BONECO specialist dealer or in our online store at this address:
www.shop.boneco.us
9
CLEANING FUNCTION
SAFETY INSTRUCTIONS
Always unplug the BONECO S200 and wait one hour
so the remaining water can cool down. Failure to do so can result in severe burns!
PROCEDURE
Although the anti-mineral pad absorbs most of the lime in the water, the heating plate of the BONECO S200 ex­periences limescale build-up af ter an extended operating time.
The BONECO S200 is equipped with a cleaning function for simple and convenient descaling. This warms and cools the heating plate multiple times in order that the lime becomes crumbly and can be easily removed.
DURATION OF THE CLEANING
The cleaning usually lasts between 1 and 4 hours. How­ever, the duration can be adjusted at your discretion until the desired ef fect is achieved.
STARTING THE CLEANING
1. Switch off the BONECO S200 and let it cool down for 1 hour.
2. Remove the anti-mineral pad and empty the water tank.
3. Mix 1 bag EZCal® with 32 oz. (1 liter) of warm tap water.
4. Add the mixture to the BONECO S200.
en
5. Move the control knob to the position to start the cleaning.
6. Switch off the BONECO S200 after the desired cleaning time.
7. Unplug the BONECO S200 and rinse the water base with tap water.
8. Place the anti-mineral pad back in the water base.