Boneco 7147, 7145 User Manual

PLEASE READ AND SAVE ALL INSTRUCTIONS!
LISEZ ET CONSERVEZ TOUTES LES INSTRUCTIONS!
¡POR FAVOR LEA Y GUARDE TODAS LAS INSTRUCCIONES!
7145 / 7147
Instructions for use (5 – 22)
Instructions d’utilisation (23 – 40)
Instrucciones para el uso (41 – 57)
en
a
fr
a
es
Instructions for use
en
en
PLEASE READ AND SAVE ALL THESE INSTRUCTIONS!
Important safety instructions
• Prior to using the appliance, read through the in structions for complete use and retain in a safe place for later reference.
• WARNING – Only use the Ultrasonic indoors and within the specified technical data. Improper use can be hazardous for the health and lead to critical injury.
• Connect the unit only to alternating current (AC) with voltage according to the rating label.
• Children cannot recognize the hazards associated with the usage of electrical appliances. For this reason, always supervise children when they are near the humidifier (image 1).
• Never use the appliance if there is any damage to the appliance or cable (2), after malfunction, after the appliance has been dropped (3) or damaged in any other way.
• Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger to the user.
• Place the humidifier on a dry, level surface (5).
Do not place the appliance directly on the floor or next to a heating vent (6).
• If the mist comes in contact with the floor prior to evaporating, the floor surface can become damaged. We do not accept any liability for damages in the case of incorrect placement of the unit.
• The unit should be placed in an elevated position (7), e.g. on a table, chest of drawers, etc.
• Place appliance where it is not easily knocked over (8).
• Always unplug when not in use.
• Only operate the humidifier when it is completely assembled.
• ALWAYS unplug before removing/filling/emptying the water tank, before cleaning/maintaining, assembling/ dismantling of individual parts and before moving the appliance.
• Do not touch the water in the base during operation because of high frequency vibrations in the water.
• Do not run power cords under carpets, and do not cover with throw rugs. Arrange cord so that it will not be tripped over.
• Never pull the plug from the outlet by the cable or with wet hands.
• Do not use the appliance where combustible gases or vapors are present.
• Do not expose the appliance to rain, or use near water, in a bathroom, laundry area or other damp location.
• This unit must be used in its upright position.
• Do not allow foreign objects to enter ventilation or ex haust opening as this may cause electric shock or damage to the appliance. Do not block air outlets or intakes.
• Do not pour water into the mist outlet of the appliance.
• This appliance has a polarized plug (one blade is wider than the other). To reduce risk of shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.
• A loose fit between the plug (receptacle) and the AC outlet may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn receptacles.
• Do not sit, stand or place any heavy objects on the appliance.
• Do not submerge the main body in water or other liquids.
• Disconnect power supply before servicing.
• Persons who are not familiar with the instructions for use, as well as children and persons under the influence of medication, alcohol, or drugs are not permitted to operate the appliance, or are only per mitted to operate it under supervision.
• To protect health safety and proper humidifier function use only clean, contamination-free, cold, fresh tap wa­ter in your humidifier. If your water source is contam­inated or if you are uncertain of its safety use distilled water. In addition, it is advised to clean and maintain
your humidifier in a timely manner as instructed in this manual.
• The use of water additives, such as ethereal/essential oils, fragrances, eucalyptus, water conditioners etc., damages the tank material and as a consequence the whole unit. Any use of such additives will void the manufacturer’s warranty.
• Remark: Neither humans nor animals can hear the high frequency vibrations.
1
4
7
en
2
3
5
8
96
Foreword
en
Congratulations on choosing the Ultrasonic Humidifier 7145/ 7147!
Did you know that dry room air:
• Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging eyes?
• Encourages infections and illnesses of respiratory system?
• Causes weariness, tiredness and poor concentration?
• Stresses household pets and house plants?
• Encourages the formation of dust and the electrostatic charging of textiles made of synthetic fibers, carpets and plastic flooring?
• Damages furnishings made of wood and parquet?
• Detunes musical instruments?
General information
A comfortable atmosphere indoors is reached with a rela­tive humidity level between 40 and 60%. Your humidifier automatically controls the humidity level according to the desired setting. If the air is too dry, the humidifier will auto­matically switch on. As soon as the desired humidity level is reached, it will switch off.
Unpacking
• Carefully remove the humidifier from the box. Place your hands underneath the product to pull it out of the box (10).
• Warning: Do not take the unit out of the box by pulling up on the tank handle - base may fall and will be da­maged (11).
• Remove the plastic bag from the humidifier.
• Observe the information given on the rating plate about the voltage.
• Use the original packaging for storing the appliance if you do not use the humidifier all year round.
10
11
Description of the appliance
Evaporation chamber
Demineralization cartridge
Water tank cap
Mist outlet (rotating)
Water tank
Hydro Cell
en
Brush
Water level sensor
Membrane
Nebulizer space
Control panel
Main body
Power Plug
Setting up
en
Finding the ideal location for your unit:
• Do not place the humidifier directly next to a heating vent or on a floor with floor heating. The moisture of the mist can damage the floor surface (6) (see Safety Instructions).
• The unit should be placed in an elevated position (7), e.g. on a table, chest, etc. at least 3 ft off the floor.
• The mist outlet must not be pointed directly at plants, furniture, or other objects (12). Keep distance of at least 20 inches (50cm).
• Soak the demineralization cartridge in a water bath 24 hours before using it (13). The granules have to absorb water to reach maximum performance. If the cartridge is soaked in the tank, make sure to exchange the water and empty the water from the base before using the humidifier.
• On average the demineralization cartridge should be replaced every 2 – 3 months depending on your water hardness. Some areas may need to replace the cart­ridge sooner, some may last longer. The cartridge must be exchanged at the latest after 6 months or the unit does not reach its full performance anymore.
See «Replacement of the demineralization cartridge».
• Read the instructions under «Filling the Tank» for adding water in the humidifier (14 and 15).
• Place the water tank onto the base.
• Insert the plug into the socket and switch on the appliance using the on/off dial (18 and 19).
• About 10 to 15 minutes after it is switched on the de­vice will reach its full output level.
• Make sure that the cable is not pinched anywhere (9). Do not operate the humidifier if the cable is damaged (2).
12
13
10
Filling the tank
Always unplug the unit before removing the water tank. Do not touch the water in the base during operation!
To protect health safety and proper humidi- fier function use only clean, contamination-free,
cold, fresh tap water in your humidifier. If your water source is contaminated or if you are uncertain of its safety use distilled water.
Do not operate the humidifier when the water tank is empty! When the water reaches the minimum level, the unit switches off the nebulizer function automatically. The empty indicator light comes on showing tank is empty.
• Remove the water tank from the base and unscrew the
water tank cap (14).
• Make sure that no foreign objects are in the water
tank.
• Fill the tank with clean, cold water from the tap (15).
Close the cap of the water tank securely, place the wa­ter tank onto the base (16). The water is now running from the tank into the base.
• Do not pour water into the mist outlet of the appliance
(17).
• Insert the plug into the socket (18) and switch on the
appliance using the on/off dial (19). The empty indi­cator light may stay illuminated for some seconds until the base is filled with water.
Do not use additives
Water additives (ethereal/essential oils, fragrances, eucalyptus, water conditioners, etc.) must not be used! Even a small amount can cause cracks in the material. The material isn’t made for the use of such additives. One drop is enough to damage the tank and as a consequence the unit. Any use of such additives will void the manufacturer’s warranty.
14
17
15 18
16
19
en
11
Operation 7145
en
C
B
A
A) On/Off Dial and regulation of mist output
Turning the rotary dial clockwise switches the appliance on and at the same time regulates the mist output from low to high.
B) Hygrostat (setting the humidity level)
The desired humidity level can be set by turning the rotary switch clockwise. A relative humidity between 40 and 60% is recommended. You can achieve this level by rotating the switch until it is roughly in the vertical position. The accu­racy of measurement is +/- 5%. The unit will switch off when the moisture level exceeds the desired setting. The appliance does not switch off if the switch is turned all the way to the right. This activates the continuous operation function.
C) Empty indicator (red)
The water level is easy to see, thanks to the transparent water tank. The appliance also alerts you when the wa­ter tank is empty. The red empty indicator is illuminated (symbol C). Please read the chapter «Filling the tank» for more information. The red symbol C may stay illuminated for some seconds with a refilled tank until the base is filled with water.
12
Operation 7147
H
E
L
F
I
D
J
A
G
C
M
B
K
A) On/Off Button
You can switch the unit on or off by pressing button A. This button is also used to reset the cleaning indicator light (by holding down).
B) Hygrostat (setting the humidity level)
By pressing button B you can set the desired humidity level from 30% to 80% or CO (continuous operation). A relative humidity between 40 and 60% is recommended. The ac­curacy of measurement is +/- 5%. The unit will switch off when the moisture level exceeds the desired setting. During selection the target value is displayed (symbol DESIRED). The display will automatically show the current value after a few seconds (symbol CURRENT).
C) Timer
Using button C, the operation time can be set adjusta­ble between 1 and 8 hours or CO (continuous operation). Symbol G shows the operating period that has been set (1h/2h/3h/4h/5h/6h/7h/8h/CO). The display will automati­cally show the current humidity after a few seconds.
D) Mist output (regulating mist output)
By repeatedly pressing button D you can control the mist output. Symbol H shows which of the three levels (low/ medium/high) you have selected.
E) Operation with pre-heating (warm mist)
Button E is used for switching the pre-heating on and off (symbol I lights up). As a result, the water is pre-heated to a temperature of 176 °F (80 °C) before entering the nebulizer space. It takes approx. 10 to 15 minutes for the water in the base to warm up. The mist now leaves the humidifier at a pleasant temperature of 104 °F (40 °C). The advantage of this is that the room temperature does not drop and, in addition, it significantly improves the water quality maintenance.
F) Automatic mode and Sleep mode
The automatic and sleep modes can be activated by pres­sing button F. By pressing the button once, the automatic function is switched on (symbol J appears on the display), maintaining the optimum humidity subject to the tempera­ture. Control takes place by means of output quantity and pre-set target value. By pressing the button twice, the sleep function is switched on (symbol K appears on the display), the target humidity is 50 – 65%; the operation time is set at 6 hours and the heating is switched on. In addition, the output quantity is also controlled subject to the difference between the target value and the actual value. The hygrostat and mist output settings cannot be changed in either mode. If the buttons B or D are pressed, the unit will no longer be in auto or sleep mode.
G) Timer Indicator
H) Mist Output Indicator
I) Pre-heating Indicator
J) Automatic Mode Indicator
K) Sleep Mode Indicator
L) Empty indicator
The water level is easy to see, thanks to the transparent water tank. The appliance also alerts you when the water tank is empty. The empty indicator is illuminated (symbol L). Please read the chapter «Filling the tank» for more informa­tion. The symbol L may stay illuminated for some seconds with a refilled tank until the base is filled with water.
M) Cleaning indicator
If symbol M «CLEAN» appears on the display, the appliance should be cleaned as recommended by the manufacturer. This symbol comes on automatically every 2 weeks, de­pending on the level of use. The display can be reset by
holding down button A until the light disappears.
en
13
Cleaning/Maintenance
en
Always unplug the unit before removing the
water tank. Do not touch the water in the base
during operation!
Caution – risk of electric shock and damage of the product!
• Switch off the appliance (20) and unplug it from the
socket before cleaning it (21).
• Clean the water tank and the base regularly. Use water
only, no detergents (22).
• Use EZCal and EZCal PRO custom cleaning and
descaling agents only to remove deposits from the membrane regularly (23). There is a sample of EZCal included in the packaging of your humidifier. Instruc­tions for using are on the packet. Only use 1 packet for 32 oz of water. Do not change the ratio. Do NOT run the unit when using EZCal and EZCal PRO. This can cause damage to the product and voids the warranty. Tho­roughly rinse the base with tap water after using EZCal and EZCal PRO and make sure no EZCal and EZCal PRO residues remains in the base.
EZCal and EZCal PRO are the only recommended
cleaning and descaling solution. Do NOT use any
other cleaning solutions since it can damage the
product. Any use of cleaning solutions apart from
EZCal and EZCal PRO will void the warranty.
20
21
22
23
24
25
WARM
WARM
ACID
14
• Make sure main body is never submerged in water
(24)!
• 7147: The cleaning indicator still appears on the dis-
play after cleaning. To reset it hold down the ON/OFF button until the clean light disappears.
• Clean the inner parts with a soft cloth. Do not use any
solvents or aggressive cleaning agents to clean the appliance (25).
• Only use the brush to clean the membrane. This should
be done once a week. Only use the soft-bristle portion of the brush (26).
• Change the water in the tank at least once a week if
water is standing for more than a week.
• To remove the mist outlet (27): Twist the mist outlet to
either the right or the left. Align the arrow on the mist outlet with the arrow on the ring around the mist outlet. Only one set of arrows on mist outlet and ring will align. Pull up on the mist outlet once the arrows are aligned.
Water quality maintenance
The Hydro Cell keeps humidifiers operating at their highest level between recommended cleanings. Good for approxi­mately one to two months, depending on the water quality, the Hydro Cell ensures the humidifier’s functionality while providing fresh humidification performance. It starts to work as soon as it comes in to contact with water, even if the unit is turned off. The Hydro Cell should be changed every one to two months*. Look at picture 28 for the posi­tion of the Hydro Cell in the water tank of the unit. Switch off the unit first. Contact your local retailer or check our website www.boneco.us for reorder information.
* Depending on the water quality.
27
28
en
26
29
15
Replacement of the demineralization
en
cartridge
The water tank is equipped with a demineralization cartridge. This cartridge has to be replaced every 2 – 3 months. If the water is very hard, it may be necessary to replace the cartridge earlier. White dust around the device is a sure sign that the cartridge needs replacing. If white residue still forms around the device after a new cartridge has been inserted, please make sure that the water you are using is untreated. If the water flows an ion exchanger – (sodium is added to remove calcium) in the building before it is used in the humidifier, salt can pre­cipitate as white dust around the device. The demineralization cartridge or the granules must be exchanged at the latest after 6 months or the unit does not reach its full performance anymore.
Always unplug the unit before removing the water tank. Do not touch the water in the base during operation!
through a decalcification system – such as
• Turn the plastic cup and cartridge over and shake until all granules are in the cartridge (37).
• Remove the plastic cup and the pink styrofoam piece from the cartridge (38) and retain for future use (the refill granules consists of 3 refill bags) (39).
• Close the cartridge (40).
• Soak the demineralization cartridge in a water bath
24 hours before using it (43). The granules have to
absorb water to reach maximum performance. If the cartridge is soaked in the tank, make sure to exchange the water and empty the water from the base before using the humidifier.
• Screw the cartridge on the water tank cap (44).
• Screw the cartridge on the bottom side of the water tank, put the tank on the main body (45).
Placing granules in the center of the cartridge allows them to escape in the unit or to clog the unit. The unit will no longer operate properly and the granules need to be cleaned out thoroughly.
30
31
Option A: replace the granules
• Remove the water tank from the base and unscrew the water tank cap (30).
• The demineralization cartridge is attached to the tank cap. Unscrew the cartridge from the cap by turning it counter-clockwise (31). Important: do NOT dispose of the water tank cap!
• Open the cartridge (32).
• Throw the content into the waste (Attention! Disposed granules can make the floor slippery!) (33).
• Place the enclosed pink styrofoam piece in the center of the cartridge. Do not push it to the bottom as it will be difficult to remove afterwards (34).
• Pour the contents of one refill granules bag into the plastic cup that is included with the refill granules pa­ckaging (35).
• Place the empty cartridge with the plug in the center onto the plastic cup (36).
16
Option B: replace the whole cartridge
• Remove the water tank from the base and unscrew the water tank cap (30).
• The demineralization cartridge is attached to the tank cap. Unscrew the cartridge from the cap by turning it counter-clockwise (31). Important: do NOT dispose of the water tank cap!
• Throw the whole cartridge into the waste (41).
• Unpack the new cartridge (42).
• Soak the demineralization cartridge in a water bath 24 hours before using it (43). The granules have to absorb water to reach maximum performance. If the cartridge is soaked in the tank, make sure to exchange the water and empty the water from the base before using the humidifier.
• Screw the cartridge on the water tank cap (44). Close tank cap well and place the tank on the main body (45).
32 33
34 35
38
43
en
36
37
39
41
40
44
42 45
17
Storing the appliance for extended periods
en
Clean the appliance as described earlier and allow to dry thoroughly. Preferably store the appliance in its original box, in a dry place away from high temperatures.
Legal notice
The humidifier is cUL-listed. Subject to technical change. The instructions for use are protected by copyright © BONECO AG.
Accessories
Contact your local retailer or check our website www. boneco.us for re-order information.
Customer Service
Customer Service (USA) 1-800-336-0326
Technical data 7145
Electrical voltage 120 V / 60 Hz Power consumption up to 45 W Humidity output up to 2.5 gallons / 24 h Suitable for rooms up to 540 sq ft / 50 m Dimensions (LxWxH) 9.5 x 10.3 x 12.2 in
24 x 26 x 31 cm Weight (empty) 6.6 lbs / 3 kg Accessories Demineralization cartridge A7531
Hydro Cell A200 EZCal A7417 EZCal PRO A100
www.boneco.us
Troubleshooting
Problem Possible cause What to do
Unit does not operate Power cable not plugged in Plug in power cable No water in the tank (Empty indicator on) Fill tank with water and wait 10 min. No mist output Unit needs cleaning Descale the water base using EZCal and EZCal PRO Demineralization cartridge exhausted Replace cartridge or granules Demineralization cartridge overfilled Take out 2 tablespoons of granules and throw
with granules them away Weak mist output Water temperature too low Set mist output to maximum, after 15 min.
the humidifier will work properly again Mineral deposits on membrane Clean membrane using EZCal and EZCal PRO and brush Unit running intermittently Replace demineralization cartridge or granules White dust around the humidifier Demineralization cartridge exhausted Used granules must go in waste
Technical data 7147
Electrical voltage 120 V / 60 Hz Power consumption up to 40 W / (125 W*) Humidity output up to 3 gallons / 24 h*
2
Suitable for rooms up to 600 sq ft / 55 m Dimensions (LxWxH) 9.5 x 10.3 x 12.2 in
24 x 26 x 31 cm Weight (empty) 6.6 lbs / 3 kg Accessories Demineralization cartridge A7531
Hydro Cell A200 EZCal A7417 EZCal PRO A100
* when used with pre-heating to 176 °F (80 °C)
2
18
Loading...