Boneco 7135 Instructions For Use Manual

Page 1
PLEASE READ AND SAVE ALL INSTRUCTIONS!
LISEZ ET CONSERVEZ TOUTES LES INSTRUCTIONS!
¡POR FAVOR LEA Y GUARDE TODAS LAS INSTRUCCIONES!
7135
Page 2
5
en
Instructions for use
Page 3
6
en
Important safety instructions
• Prior to using the appliance, read through the in structions for complete use and retain in a safe place for later reference.
• WARNING – Only use the Ultrasonic indoors and within the specified technical data. Improper use can be hazardous for the health and lead to critical injury.
• Connect the unit only to alternating current (AC) with voltage according to the rating label.
• Children cannot recognize the hazards associated with the usage of electrical appliances. For this reason, always supervise children when they are near the humidifier (image 1).
• Never use the appliance if there is any damage to the appliance or cable (2), after malfunction, after the appliance has been dropped (3) or damaged in any other way.
• Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger to the user.
• Place the humidifier on a dry, level surface (5).
Do not place the appliance directly on the floor or next to a heating vent (6).
• If the mist comes in contact with the floor prior to evaporating, the floor surface can become damaged. We do not accept any liability for damages in the case of incorrect placement of the unit.
• The unit should be placed in an elevated position (7), e.g. on a table, chest of drawers, etc.
• Place appliance where it is not easily knocked over (8).
• Always unplug when not in use.
• Only operate the humidifier when it is completely assembled.
• ALWAYS unplug before removing/filling/emptying the water tank, before cleaning/maintaining, assembling/ dismantling of individual parts and before moving the appliance.
• Do not touch the water in the base during operation because of high frequency vibrations in the water.
• Do not run power cords under carpets, and do not cover with throw rugs. Arrange cord so that it will not be tripped over.
• Never pull the plug from the outlet by the cable or with wet hands.
• Do not use the appliance where combustible gases or vapors are present.
• Do not expose the appliance to rain, or use near water, in a bathroom, laundry area or other damp location.
• This unit must be used in its upright position.
• Do not allow foreign objects to enter ventilation or ex haust opening as this may cause electric shock or damage to the appliance. Do not block air outlets or intakes.
• Do not pour water into the mist outlet of the appliance.
• This appliance has a polarized plug (one blade is wider than the other). To reduce risk of shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.
• A loose fit between the plug (receptacle) and the AC outlet may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn receptacles.
• Do not sit, stand or place any heavy objects on the appliance.
• Do not submerge the main body in water or other liquids.
• Disconnect power supply before servicing.
• Persons who are not familiar with the instructions for use, as well as children and persons under the influence of medication, alcohol, or drugs are not permitted to operate the appliance, or are only per­mitted to operate it under supervision.
• To protect health safety and proper humidifier function use only clean, contamination-free, cold, fresh tap water in your humidifier. If your water source is contam­inated or if you are uncertain of its safety use distilled water. In addition, it is advised to clean and maintain
your humidifier in a timely manner as instructed in this manual.
• The use of water additives, such as ethereal/essential oils, fragrances, eucalyptus, water conditioners etc., damages the tank material and as a consequence the whole unit. Any use of such additives will void the manufacturer’s warranty.
• Remark: Neither humans nor animals can hear the high frequency vibrations.
PLEASE READ AND SAVE ALL THESE INSTRUCTIONS!
Page 4
7
en
5
1
3
1ft
4ft
3ft
7
96
2
4
8
Page 5
8
en
Foreword
Congratulations on choosing the Ultrasonic humidifier 7135!
Did you know that dry room air:
• Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging eyes?
• Encourages infections and illnesses of respiratory system?
• Causes weariness, tiredness and poor concentration?
• Stresses household pets and house plants?
• Encourages the formation of dust and the electrostatic charging of textiles made of synthetic fibers, carpets and plastic flooring?
• Damages furnishings made of wood and parquet?
• Detunes musical instruments?
General information
A comfortable atmosphere indoors is reached with a rela­tive humidity level between 40 and 60%. Your humidifier automatically controls the humidity level according to desired setting. If the air is too dry, the humidifier will auto­matically switch on. As soon as the desired humidity level is reached, it will switch off.
Unpacking
• Carefully remove the humidifier from the box. Place your hands underneath the product to pull it out of the box (10).
• Warning: Do not take the unit out of the box by pulling up on the tank handle – base may fall and will be damaged (11).
• Warning: The mist outlet is packed in a red bag inside the box insert. Make sure that you remove the mist outlet from the packaging (12).
• Remove the plastic bag from the humidifier.
• Observe the information given on the rating plate about the voltage.
• Use the original packaging for storing the appliance if you do not use the humidifier all year round.
10
11
12
Page 6
9
en
Setting up
Finding the ideal location for your unit:
• Do not place the humidifier directly next to a heating vent or on a floor with floor heating. The moisture of the mist can damage the floor surface (6) (see Safety Instructions).
• The unit should be placed in an elevated position (7), e.g. on a table, chest, etc. at least 3 ft off the floor.
• The mist outlet must not be pointed directly at plants, furniture, or other objects (13). Keep distance of at least 20 inches (50 cm).
• Please refer to the enclosed manual for putting the A250 AQUA PRO into operation.
• Read the instructions under «Filling the tank» for adding water in the humidifier (14 and 15).
• Place the water tank onto the base.
• Insert the plug into the socket and switch on the appliance using the on/off button (18).
• About 10 to 15 minutes after it is switched on the device will reach its full output level.
• Make sure that the cable is not pinched anywhere (9). Do not operate the humidifier if the cable is damaged (2).
Membrane
Control panel
Air inlet
Mist outlet (rotating)
A250 AQUA PRO
Water tank
Evaporation chamber
Brush Water base
Power plug
Water level sensor
Main body
Description of the appliance
Water tank cap
Hydro Cell
13
Page 7
10
en
16
17
15
14
Filling the tank
Always unplug the unit before removing the water tank. Do not touch the water in the base during operation!
To protect health safety and proper humidi- fier function use only clean, contamination-free,
cold, fresh tap water in your humidifier. If your water source is contaminated or if you are uncertain of its safety use distilled water.
Do not operate the humidifier when the water tank is empty! When the water reaches the minimum level, the unit switches off the nebulizer function automatically. The red light comes on indicating tank is empty.
• Remove the water tank from the base and unscrew the
water tank cap (14). Caution: the mist outlet is loose!
• Make sure that no foreign objects are in the water
tank.
• Fill the tank with clean, cold water from the tap (15).
Close the cap of the water tank securely, place the water tank onto the base (16). The water is now running from the tank into the base.
• Do not pour water into the mist outlet of the appliance
(17).
• Insert the plug into the socket and switch on the
appliance using the on/off button (18). The red empty indicator light may stay illuminated for some seconds until the base is filled with water.
Do not use additives
Water additives (ethereal/essential oils, fragrances, eucalyptus, water conditioners, etc.) must not be used! Even a small amount can cause cracks in the material. The material isn’t made for the use of such additives. One drop is enough to damage the tank and as a consequence the unit. Any use of such additives will void the manufacturer’s warranty.
18
Page 8
11
en
C) Timer
Using button C, the operation time can be set adjust­able between 1 and 9 hours or co (continious operation). Symbol G shows the operating period that has been set (1h/2h/3h/4h/5h/6h/7h/8h/9h/co). The display will automat­ically show the current value after a few seconds.
D) Mist output (regulating mist output)
The mist output can be regulated by pressing button D several times. If the red bars are displayed, you have selected the highest level of mist output (symbol H).
E) Operation with water pre-heating (warm mist)
Button E is used for switching the pre-heating on and off (symbol I lights up). As a result, the water is pre-heated to a temperature of 176 °F (80 °C) before entering the nebulizer space. It takes approx. 10 to 15 minutes for the water in the base to warm up. The mist now leaves the humidifier at a pleasant temperature of 104 °F (40 °C). The advantage of this is that the room temperature does not drop and, in addition, it significantly improves the water quality maintenance.
F) Automatic mode and Sleep mode
The automatic and sleep modes can be activated by press­ing button F. By pressing the button once, the automatic function is switched on (symbol J appears on the display), maintaining the optimum humidity subject to the tempera­ture. Control takes place by means of output quantity and pre-set target value. If the sleep function is switched on (the symbol K appears on the display), the target humidity is 60%; the operation time is automatically set at 8 hours; the heating is switched on. In addition, the output quantity is also controlled subject to the difference between the target value and the actual value. The Timer cannot be changed in either mode. If other but­tons are pressed, the unit will no longer be in auto or sleep mode.
A) On / Off button
You can switch the unit on or off by pressing button A. This button is also used to reset the cleaning indicator light (by holding down).
B) Hygrostat (setting the humidity level)
By pressing button B you can set the desired humidity level in %. A relative humidity between 40% and 60% is recommended. The accuracy of measurement is +/- 5%. The unit will switch off when the moisture level exceeds the desired setting. The device does not switch off if the dis­play is set to «Co» (continuous operation). During selection the target value is displayed. The display will automatically show the current value after a few seconds.
Operation 7135 G) Timer Indicator
H) Mist Output Indicator
I) Pre-heating Indicator
J) Automatic Mode Indicator
K) Sleep Mode Indicator
L) Empty indicator
The water level is easy to see, thanks to the transparent water tank. The appliance also alerts you when the water tank is empty. The empty indicator is illuminated (symbol L). Please read the chapter «Filling the tank» for more informa­tion. The symbol L may stay illuminated for some seconds with a refilled tank until the base is filled with water.
M) Cleaning indicator
If symbol M and «CLEAN» appear on the display, the appli­ance should be cleaned as recommended by the manufac­turer. This symbol comes on automatically every 2 weeks, depending on the level of use. The display can be reset
by holding down button A until the light disappears.
A
BC
DEF
M
LG
HIKJ
Page 9
12
en
ACID
WARM
WARM
21
2420
23
Cleaning/Maintenance
Always unplug the unit before removing the
water tank. Do not touch the water in the base
during operation!
Caution – risk of electric shock and damage of the product!
• Switch off the appliance and unplug it from the socket
before cleaning it (19).
• Clean the water tank and the base regularly. Use water
only, no detergents (20).
• Use EZCal and EZCal PRO custom cleaning and desca-
ling agents only to remove deposits from the memb­rane regularly (21 and 22). There is a sample of EZCal included in the packaging of your humidifier. Instruc­tions for using are on the packet. Only use 1 packet for 32 oz of water. Do not change the ratio. Do NOT run the unit when using EZCal and EZCal PRO. This can cause damage to the product and voids the warranty. Tho­roughly rinse the base with tap water after using EZCal and EZCal PRO and make sure no EZCal and EZCal PRO residues remains in the base.
22
19
25
Page 10
13
en
26
Water quality maintenance
The Hydro Cell keeps humidifiers operating at their highest level between recommended cleanings. Good for approxi­mately one to two months, depending on the water quality, the Hydro Cell ensures the humidifier’s functionality while providing fresh humidification performance. It starts to work as soon as it comes in to contact with water, even if the unit is turned off. The Hydro Cell should be changed every one to two months*. Look at picture 26/27 for the position of the Hydro Cell in the water tank of the unit. Switch off the unit first. Contact your local retailer or check our website www.boneco.us for reorder information.
* Depending on the water quality.
EZCal and EZCal PRO are the only recommended
cleaning and descaling solutions. Do NOT use
any other cleaning solutions since it can damage
the product. Any use of cleaning solutions apart
from EZCal and EZCal PRO will void the warranty.
• Make sure main body is never submerged in water
(23)!
• The cleaning indicator still appears on the display after
cleaning. To reset it hold down the ON/OFF button until the clean light stops flashing.
• Clean the inner parts with a soft cloth. Do not use any
solvents or aggressive cleaning agents to clean the appliance (24).
• Only use the brush to clean the membrane. This should
be done once a week. Only use the soft-bristle portion of the brush (25).
• Change the water in the tank at least once a week if
water is standing for more than a week.
27
Page 11
14
en
Technical data
Electrical voltage 120 V / 60 Hz Power consumption up to 45 W / (140W*) Humidity output up to 3.5 gallons / 24 h* Suitable for rooms up to 650 sq ft / 60 m
2
Dimensions (LxWxH) 15 x 8.7 x 13.8 in 38 x 22 x 35 cm
Weight (empty) 7.7 lbs / 3.5 kg Accessories A250 AQUA PRO
Hydro Cell A200 EZCal A7417 EZCal PRO A100
* when used with pre-heating to 176 °F (80 °C)
Storing the appliance for extended periods
Clean the appliance as described earlier and allow to dry thoroughly. Preferably store the appliance in its original box, in a dry place away from high temperatures.
Legal notice
The humidifier is cUL-listed. Subject to technical change. The instructions for use are protected by copyright © BONECO AG.
Accessories
Contact your local retailer or check our website www.boneco.us for re-order information.
Customer Service
Customer Service (USA) 1-800-336-0326 www.boneco.us
Troubleshooting
Problem Possible cause What to do
Unit does not operate Power cable not plugged in Plug in power cable No water in the tank (Empty indicator on) Fill tank with water and wait 10 min. No mist output Unit needs cleaning Descale the water base using EZCal and EZCal PRO A250 AQUA PRO exhausted Replace A250 AQUA PRO Weak mist output Water temperature too low Set mist output to maximum, after 15 min.
the humidifier will work properly again Mineral deposits on membrane Clean membrane using EZCal and EZCal PRO and brush Unit running intermittently Replace A250 AQUA PRO White dust around the humidifier A250 AQUA PRO exhausted
Page 12
15
en
General Humidifier Questions
Q. Why isn’t there enough moisture in my room? A. How often do you run the unit? If the unit is only run at
night, then during the day the moisture level will drop if moisture is not constantly added to the air.
Q. Do you leave your door open or closed when the
unit is running?
A. a) By leaving the door open, this allows moisture to
leave the room and go into other areas of the house. If you would like the moisture to stay within one specific room you should consider closing the door while the unit is running.
b) Wood, leather, carpet, curtains, and other types of
fabric soak up a lot of moisture, thus not leaving enough moisture for the air. If the window is left open, then this allows moisture to escape the room. Another factor is a lot of times the unit is placed next to a heating device. The idea is that the air blowing into the room will quickly place moisture around the room. Unfortunately, this concept does not work because the hot air coming out of a vent will soak up most of the moisture, and none of the air within the room will receive any.
Q. How much moisture do I need in my room? A. Suggested humidity levels are between 40 – 60%.
Q. What are the effects of too little or too much
humidity?
A. Dry air can cause dry skin, static electricity, out of tune
musical instruments, increased levels of dust (dry air causes dust to rise), damage to wooden objects (dry out and eventually cracks appear), discomfort, sickness, and dries out nasal membranes.
Over-humidifying the air can cause mold and wallpaper
to peel.
Q. Why do I need a humidifier when I can just open
my window?
A. The moisture level within the outside air is not high
enough to humidify a room. The colder the air the less moisture it is capable to hold, and the more the air is heated up the percentage of relative humidity is lower. Relative humidity means the amount of water vapor in the air, compared to the amount the air could hold if it was totally saturated. The difference is higher between outside and inside temperatures; more humidification is needed because of the dry air in the room.
Q. Where should I place my humidifier? A. The unit should be free-standing and not close to a
wall, window, door, or thermal bridge so that air may circulate around the unit.
Ultrasonic Frequent Questions
Q. There is no fill-line on the water tank, how far
may I fill it up?
A. There is no fill line on the water tank, and it may be
filled all the way to the top.
Q. Is it ok to use distilled water with the unit? A. For best results with your ultrasonic humidifier use
distilled or reverse-osmosis water.
Q. The directions tell me not to place the unit directly
on the floor, why do I have to elevate the unit?
A. The idea with this unit is to allow one to force humidity
into the air. Because of this, the carpeting or wood floor surrounding the unit may become damp. If the unit is placed at least 3 feet off the floor, the mist will have the opportunity to evaporate before hitting the floor.
Q. Water does not go into the tank. A. In order to fill the tank, it must be turned upside down.
The cartridge is placed on the water tank cap. Do not pour water in the tube which is the mist outlet.
Q. White dust is emitted from the unit A. White dust particles are minerals that are broken up in
tiny pieces by the ultrasonic process.
Solve the problem:
• Don’t use water from a pre-installed water softener, or sodium instead of calcium will be emitted from the unit. Use distilled water instead.
• For very hard water areas use only distilled water.
• Use Reverse-Osmosis water (R-O water) instead of distilled water.
Cleaning light is illuminated (digital models)
Switch off the unit and unplug it. Empty the water in the
base. Rinse the base with warm/clean water. Do not submerge the base! Visually inspect the base for dirt or mineral build up. If soft water is used decalcifying the unit every 4 weeks with EZCal is suggested. If hard water is used the unit should be decalcified every 2 weeks. Do not forget to reset the clean light after resetting the unit.
Q. Reset cleaning light (digital models) A. The cleaning light does not automatically reset. Hold
down the power button (button A in instruction manual) until the light stops flashing. The light automatically comes on approx. after 14 days of plugging in the unit.
Q. The hygrometer on unit reads a different humidity
level than external hygrometer.
A. Not all hygrometers are calibrated the same, and most
are off by +/- 5%. Plus the humidity level is not the same in the whole room. The air circulation is different in every corner of the room. The unit should not be placed near a heating vent or a radiator as the heat will absorb all of the moisture.
Q. Humidity level is not changing or does not reach
the desired humidity level.
A. If the water tank needs refilling more than once per
day, the unit is working properly and the climatic con­dition in the room has an influence on the humidity.
Page 13
16
en
Reasons for low humidity level:
• air circulation is very high (air is fully exchanged several times per day – the humidifier needs to starts its work from scratch)
• insulation of home (see air circulation)
• open space with high ceilings (not only the footage of the room counts but also the height) – high-rise buil­dings require more humidification.
• open windows – works similar to air circulation (if it is very cold outside don’t open the window more than 2 times per day for 3 minutes)
• big difference between outside temperature and inside temperature – the colder the air the less moisture it is capable to hold and the more the air is heated up the lower is the percentage of relative humidity (=the amount of water vapor in the air, compared to the amount the air could hold if it was totally saturated)
• position of the unit - if it is placed close to a door, window or air vent. This increases the air circulation.
Q. Tank is leaking A. Check if there are any hairline cracks. Dropped units or
water tanks that are cracked will not be covered under the warranty. Please contact the retailer the unit was purchased from in case your unit arrives damaged.
Q. Placing the face in the mist A. It is not recommended that anybody places their face
in the mist. It is an electrical product and should not be played with.
Q. No mist / unit is not working / empty indicator
keeps flashing
A. Fill up the water tank. Check if water is flowing through
the A250 AQUA PRO (attached to the water tank cap). If the water tank is full but there is only little water in the base it indicates that the water is now flowing through the A250 AQUA PRO.
• Wait for 15 minutes to allow the mist to come out of the unit.
• If the unit is not working and the empty light is not flas­hing you might have set the desired humidity too low and the current humidity level in the room is higher. That is why the unit switches off automatically.
• If the empty indicator keeps flashing and the tank is full, the water is not flowing through the cartridge. Exchange the A250 AQUA PRO after 2-6 months, in areas with hard water exchange the cartridge after 1-2 months. However, the A250 AQUA PRO must be exchanged at the latest after 6 months or the unit does not reach its full performance anymore.
Q. Water tank cap is too tight to unscrew A. This could be a cause of the air pressure within the
water tank. Depress the spring on the bottom of the water tank cap to release air from the water tank. Continue to do this until you are able to unscrew the water tank cap.
Accessories
Q. Do I need to keep any parts before I replace the
A250 AQUA PRO?
A. Yes, always keep the water tank cap (this is the piece
that attaches the A250 AQUA PRO to the water tank).
Q. What is the Hydro Cell and how long is it good for? A. The Hydro Cell keeps humidifiers operating at their
highest level between recommended cleanings*. Good for approximately one to two months, depending on the water quality, the Hydro Cell ensures the humidifier’s functionality while providing fresh humidification performance. It needs to be replaced every one to two months*.
* Depending on the water quality.
Q. Placement of the Hydro Cell A. Please see picture 26/27 for instructions.
Q. What is EZCal and EZCal PRO? A. There is a sample packet of EZCal included in the
packaging of your humidifier. EZCal and EZCal PRO are used for cleaning and descaling any of the humidifiers and cleans mineral build-up. EZCal and EZCal PRO are the only recommended cleaning and descaling solutions. Do NOT use any other cleaning solutions since it can damage the product. Any use of cleaning solutions apart from EZCal and EZCal PRO will void the warranty. Instructions for using are on the packet. Only use 1 packet for 32 oz of water. Do not change the ratio. It can also be used for other humidifier brands. Thoroughly rinse the base with tap water and make sure no EZCal and EZCal PRO residues remains in the base! EZCal and EZCal PRO are available at selected retail stores and online www.boneco.us.
Please refer to the enclosed manual for putting the A250 AQUA PRO into operation.
Page 14
Please check our website www.boneco.us
for further information.
BONECO is a registered trademark of BONECO AG, Switzerland
33557-06
Loading...