Instructions for use
en
en
PLEASE READ AND SAVE ALL THESE INSTRUCTIONS!
Important safety instructions
• Prior to using the appliance, read through the in­structions for complete use and retain in a safe place for later reference.
• WARNING – Only use the appliance indoors and within the specified technical data. Improper use can be hazardous for the health and lead to critical injury.
• Connect the unit only to alternating current with voltage according to the rating label.
• Children cannot recognize the hazards associated with the usage of electrical appliances. For this reason, always supervise children when they are near the humidifier (image 1).
• Never use the appliance if there is any damage to the appliance or cable (2), after malfunction, after the appliance has been dropped (3) or damaged in any other way.
• Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger to the user.
• Place the humidifier on a dry, level surface (5).
• Do not place the appliance next to heating vent.
• Place appliance where it is not easily knocked over (6).
• Always unplug when not in use.
• Only operate the humidifier when it is completely assembled.
• ALWAYS unplug before removing/filling/emptying the water tank, before cleaning/maintaining, assembling/ dismantling of individual parts and before moving the appliance.
• Do not run power cords under carpets, and do not co­ver with throw rugs. Arrange cord so that it will not be tripped over.
• Never pull the plug from the outlet by the cable or with wet hands (7).
• Do not use the appliance where combustible gases or vapors are present.
• Do not expose the appliance to rain, or use near water, in a bathroom, laundry area or other damp location.
• This unit must be used in its upright position.
• Do not allow foreign objects to enter ventilation or ex haust opening as this may cause electric shock or damage to the appliance. Do not block air outlets or intakes (8).
• This appliance has a polarized plug (one blade is wider than the other). To reduce risk of shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to alter this safety feature.
• A loose fit between the plug and the AC outlet (receptacle) may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn receptacles.
• Do not sit, stand or place any heavy objects on the appliance.
• Do not submerge the main body in water or other liquids.
• Disconnect power supply before servicing.
• Persons who are not familiar with the instructions for use, as well as children and persons under the influence of medication, alcohol, or drugs are not permitted to operate the appliance, or are only per­mitted to operate it under supervision.
• The use of water additives, such as ethereal/essential oils, fragrances, eucalyptus, water conditioners etc., damages the tank material and as a consequence the whole unit. Any use of such additives in the tank will void the manufacturer’s warranty. Please read chapter «use of fragrances».
1
4
7
en
2
3
5
8
96
Foreword
en
Congratulations on purchasing the 2055A Air Washer!
Did you know that excessively dry indoor air
• dries out mucus membranes and causes chapped lips and stinging eyes?
• promotes infections and diseases of the respiratory tract?
• leads to weariness, tiredness and poor concentration?
• is a burden on pets and house plants?
• promotes the formation of dust and increases the elec­trostatic charge of textiles made from synthetic fibers, carpets and synthetic floors?
• damages furnishings made from wood, especially par­quet floors?
• makes musical instruments go out of tune?
General
The indoor climate is generally pleasant when the relative humidity is between 40 and 60%. Air humidification is es­pecially sensible in winter, but does not replace the regular airing of living spaces.
How it works
Your appliance
• washes and humidifies the air without using filter mats
• works quietly in two operation modes
• is manufactured from high-quality, long-life components.
• has a large cleansing capacity through pre-ionization. The individual dust particles are ionized (charged) and stick to the humidifier discs.
Special humidifying discs rotate in a water bath inside the unit; this cleanses the air passing over them of impurities in a natural way – in the same way that air is washed by the rain in nature.
The air humidification takes place according to the self­regulating principle of cold evaporation. The appliance therefore generates ideal air humidity, without the need for additional control units.
Unpacking
• Remove the appliance carefully from the packaging (10 – 12). Place your hands underneath the product
to pull it out of the box. The top part of the unit is only placed on the base; it is NOT attached.
• Remove the plastic bag from the unit (13).
• Remove all cardboard pieces from the disc pack (14).
• Check the details of the electrical supply on the rating plate (15).
• Use the original packaging to store the appliance if you do not use it throughout the year.
10
11
12
13
14
Description of the appliance
Air inlet
Cover
Control panel
Air outlet
1 disc pack with 16 humidifying discs
Putting into operation
The best location for your appliance is:
• On the floor, or on a level, dry surface in the room.
• Pay proper attention to easy accessibility and sufficient space for servicing and cleaning the unit.
• Read the section «Filling the tank» on how to fill the water tank (16 – 20).
• Place the water tank on the lower part (20).
• Connect the power cable to the outlet and switch the appliance on using the On/Off switch.
• The unit will reach full humidity output about 10 – 15 minutes after you switch it on.
• Ensure that the cable is not trapped (9). Do not switch on the unit if the cable is defective (2).
Water tank
en
15
Rotary lock
Fragrance container and rotary lock opener for humidifying discs
Water base
Water tank cap
Hydro Cell
Filling the tank
en
Always unplug the unit before removing the water tank. Do not operate the appliance when the water tank is empty!
Only fill the water tank with fresh, cold tap wa­ter. Use water additives at your own risk. We do
performance or damage.
Do not put the water tank under pressure, e.g. by filling with carbonated mineral water. Do not add any essential oils or fragrances to the water; the plastic material might become discolored and damaged. Close cap tightly (19) to prevent water from leaking out of the tank.
• Remove the water tank (16).
• Ensure that there are no foreign objects in the water
• Remove the water tank cap from the tank (17). Fill the
• After filling the water tank, most of the water will
• Connect the cable to the outlet and switch the ap-
• The red empty indicator light may stay illuminated for
The unit is fitted with an automatic cut-off switch. As soon as the water tank is empty, the unit switches off automa­tically; the empty indicator illuminates (also see section «Operating 2055A»).
not accept any liability for possible reductions in
tank.
tank with fresh, cold tap water (18). Fully close the water tank cap to prevent the water tank from leaking (19). Place the water tank on the water base (20).
empty into the base. The water tank may be filled a second time (base will not overflow).
pliance on.
some seconds until the base is filled with water.
16 1817
Use of fragrances
The base contains a special fragrance container (21). A cotton ball soaked with fragrance can be placed in this container. Place fragrances only in the container provided! Do not pour fragrances in fragrance container directly! Use with cotton ball only. Water additives (e.g. essential oils, fra­grances, water conditioners) must NOT be used in the tank or anywhere else in the appliance! Even a small amount can damage the plastic or cause cracks. The material is not suitable for the use of additives. One drop is enough to damage the water tank and therefore render the unit unusable. Appliances that are damaged by additives are excluded from the warranty. The fragrance container is also used as a tool for opening the rotary locks of the humi­difying discs. To learn more about removing the discs, refer to section «Cleaning the humidifying discs».
19
21
20
10
Operating 2055A
D) Night mode
If you turn the rotary dial to position D, the appliance works in night mode and is especially quiet.
en
B
C
D
E
A
A) Rotary Dial
Connect the appliance to an outlet and turn rotary dial A from position B (off) to position C or D as required. Posi­tion D is especially quiet (night mode). Position C (normal mode) achieves maximum humidity output. The disc rota­tion speed remains constant with both mode selections. The fan rotation speed increases with level II (C).
B) Switching on/off
If the rotary dial is in position B, the appliance is switched off.
C) Normal mode
If you select position C, then normal mode is set, and the appliance reaches maximum humidity output.
E) Operating light and Automatic Shut-Off «Tank empty»
The green light (LED) (E) illuminates when the appliance is switched on. The water level is easy to see thanks to the transparent water tank. The red LED light on the appliance also shows when the unit should be refilled with water. If the water level falls below the minimum level, the appliance automatically switches off. The red symbol (E) appears on the display. When water is added, the red LED changes to green and the appliance continues operating.
Warning: When lifting the upper part off the housing, the appliance also switches off. In this case, the red light E will also appear on the display. Only when the upper part is replaced on the base does the red LED (E) disappear and the appliance resumes operation.
11
Water quality maintenance
en
The Hydro Cell keeps humidifiers operating at their highest level between recommended cleanings. Good for approxi­mately one to two months, depending on the water quality, the Hydro Cell ensures the humidifier’s functionality while providing fresh humidification performance. It starts to work as soon as it comes in to contact with water, even if the unit is turned off. The Hydro Cell should be changed every one to two months*. Look at picture 23 for the po­sition of the Hydro Cell. Switch off the unit first. Contact your local retailer or check our website www.boneco.us for reorder information.
* Depending on the water quality.
22
23
Cleaning/maintenance
Switch the appliance off and remove the power plug from the outlet before you clean the appli­ance (24).
• Regular cleaning is a pre-condition for hygienic, trouble-free operation.
• The appliance can be unassembled for cleaning in a few moves.
• Never submerge the entire unit in water (26).
• Empty and rinse the base once a week (27).
• The unit must be completely emptied and cleaned if it has been filled with water for longer than a week without being used.
Recommended cleaning intervals
The recommended cleaning intervals depend on the air and water quality, as well as operating times. A thin film of lime scale on the discs actually increases the humidity output!
• once to twice a year: upper part of housing and fan
• every 2 weeks: water tank and base
• every 4 weeks: humidifying discs
Cleaning the upper part of the housing
Remove the upper part of the unit (29) and wipe out tho­roughly once to twice a year with a damp cleaning cloth (30).
Cleaning the fan
The cover can be removed from the upper part of the unit (31). Under this cover is the fan (32), which can be cleaned with a damp cleaning cloth as required.
12
24
27
30
2825 31
en
3
1
ACID
2926
32
2
13
Cleaning the water tank and base
en
(every 2 weeks)
• Lift the water tank out of the unit, open the water tank cap and clean the tank (33 – 35).
• Lift the upper part of the unit off the base (36).
• Use EZCal and EZCal PRO custom cleaning and des­caling agents only to remove deposits from the water base regularly (37). There is a sample of EZCal included in the packaging of your humidifier. Instructions for using are on the packet. Rotate the disc assembly a few times by hand (37) to clean the mineral deposits on the humidifying discs. Only use 1 packet for 32 oz of water. Do not change the ratio. Do NOT run the unit when using EZCal and EZCal PRO. This can cause damage to the product and voids the warranty. Tho­roughly rinse the base with tap water after using EZCal and EZCal PRO and make sure no EZCal and EZCal PRO residues remains in the base.
• Empty the water base (38), remove the disc assembly (39) and rinse (40).
• Remove deposits from the base using a plastic or wooden brush (41).
Cleaning the humidifying discs (every 4 weeks)
A thin film of lime scale on the discs actually increases the humidity output! To clean, unscrew the individual humi­difying discs from each other. Rotary locks (toothed wheels) can be easily removed using the multifunctional fragrance container (42).
Next, the discs can be washed individually (43 – 44). For best results use EZCal and EZCal PRO custom cleaning agents. Refer to section «Cleaning the water tank and base» for more information of how to use EZCal and EZCal PRO.
• The toothed wheel can only be assembled in one position.
After cleaning, reassemble the appliance in the reverse se­quence. Note: rotary locks have two rest positions. Warning: Do not overtighten!
34
35
33
14
36
WARM
37
WARM
40
43
en
38
39
41
42
44
45
15
Loading...