Bonavita BV02001MU User Manual

Rechargeable Coee Scale
Precision Brewing
Model: BV02001MU
HOUSEHOLD USE ONLY
Customer Service Line: 1-855-664-1252
1-year limited warranty
• Two modes for ease of use
• Water resistant coating to prevent water damage
• Programmableauto-osettings
• Built-in timer for brewing accuracy
• 2000 gram capacity and 0.1 gram accuracy
• Rechargeable battery
PLEASE READ THIS MANUAL BEFORE USE. SAVE FOR FUTURE REFERENCE.
Rev. 11/16
GENERAL MAINTENANCE AND CARE
Avoid exposure to extreme heat or cold.
Always allow your scale to acclimate to room temperature before use.
Keep your scale in a clean environment.
Excessive dust, dirt, vibration, or air currents, as well as close proximity to other
electronic equipment, may have an adverse eect on the accuracy and reliability of
the scale.
Handle the scale with care.
This is a precision instrument and should be handled as such.
Set all items gently on the top of the platform.
Although this scale is designed to be quite durable, make sure to avoid rough treatment as this may permanently damage the internal components.
Always avoid violent shaking and dropping.
Use of an incorrect power adapter (greater than 5V) could result in damage to battery.
Limited warranty may be void if you use an incorrect adapter.
WARNING MESSAGES
“EEEE”: Overload
Quickly remove weight from platform to protect the scale.
“UNST”: Unstable or water damage
- Scale is not steady during start-up. Turn o scale, set on a stable surface
and restart scale.
Water is inside the scale. Shake out excess water and let dry.
SAVE THESE INSTRUCTIONS
WASHING INSTRUCTIONS
This scale has been treated with a water resistant coating which will allow you to wash your scale without damaging the internal electronics.
1. Hand wash only with mild soapy water.
2. Ensure the rubber charging port cover is in place before washing.
3. Wash only the platform. Wipe down other parts with a damp cloth as needed.
4. After washing the scale, shake out excess water.
5. Dry the exterior of the scale with a soft cloth or leave it to dry on a dish rack.
6. Do not submerge scale in water.
Additional safeguards:
DO NOT use liquid bleach or other harsh chemicals.
DO NOT use steel wool or abrasive sponges, as this can scratch the surface.
Avoid pouring water directly onto your scale, as water may become trapped inside.
Waterdrops on the LCD display will not interfere with weighing items. These drops will dry and disappear.
If the scale displays “UNST” or the readings jump after washing, then water
is still inside the scale. Simply shake out the excess water and let your scale
dry longer.
By following these washing instructions, you will experience shorter drying times, and your scale will provide you with years of reliable service.
SAVE THESE INSTRUCTIONS
SCALE DIAGRAM
1
2 4
3 5
7 8 9 10 11
1. Platform
2. ON/OFF button
3. MODE button
4. TIMER button
5. TARE button
6. LCD Readout
7. Mode indicator (P/R)
8. Battery level indicator
9. Timer display
10. Weight display
11. Unit of measurement indicator (g/oz)
12. USB port
13. USB cord
12
13
6
Technical Data
Capacity: 2000g Accuracy: 0.1g Units: grams (g) and ounces (oz) Key functions: ON/OFF, MODE, TARE, TIMER
• Display: LCD with backlight
Auto-o: Auto-o time is 180 seconds by default.
Operating modes: REG mode and POUR mode
Power: Rechargeable battery - USB cord Operation temperature range: 50° to 85° Fahrenheit
(10° to 30° Celsius)
CHARGING THE SCALE
1. Lift the rubber charging port cover and plug the small
end of the USB cord into the port on the scale. (FIG A)
2. Plug the larger end of the USB cord into a computer or power adapter that is 5V 2amps or less. (FIG B)
(NOTE: Plugging the cord into an adapter greater than 5V
could cause damage to the scale or reduce battery life.)
3. When charging is complete, the battery level indicator on the display will show a full charge.
4. When the scale is nished charging, remove cord and replace charging port cover.
A
B
MODE SETTING
Press the MODE button to toggle through the dierent modes and units of measurement.
Once the mode and unit of measurement have been chosen, the scale will use the same
settings each time it is turned on/o until the settings are manually changed.
REG Mode – Taring and timing must be done manually.
Units of measurement:
oz - Select this mode for pour-over brewing measured in ounces.
The letter “R” will appear on the bottom left and “oz” will appear on the bottom right of the display.
g - Select this mode for pour-over brewing measured in grams.
The letter “R” will appear on the bottom left and “g” will appear on the top right of the display.
POUR Mode – This mode includes auto-tare and auto-timer functions.
Units of measurement:
oz - Select this mode for pour-over brewing measured in ounces.
The letter “P” will appear on the bottom left and “oz” will appear on the bottom right of the display.
g - Select this mode for pour-over brewing measured in grams.
The letter “P” will appear on the bottom left and “g” will appear on the top right of the display.
OPERATION
POUR Mode:
1. Place dripper and carafe or cup on scale. The timer on the left of the display will show 0’00” and the weight on the right side of the display will automatically tare to 0.00.
Note: This mode automatically tares the rst item set on the scale; it is necessary to
manually tare subsequent items placed on scale as indicated below.
2. Add coee grounds.
3. Tare the scale by pressing TARE once. The display will show 0.00.
4. Add water. The timer will automatically start when the scale senses the weight
beginning to change. Since the display shows the weight and time, this will allow you to customize how you brew your coee.
REG Mode:
1. Place item on scale; the weight of the item is shown on the right side of the
display.
2. Press TARE as needed for each item added to the scale.
3. Start the timer by pressing the TIMER button. The display will ash once, and
then the timer will begin. The time is shown on the left side of the display.
4. To pause the timer, press the TIMER button once.
5. To reset the timer to 0’00”, press the TIMER button twice.
NOTE: The timer will reset to 0’00” once it reaches 9’59”.
TARE FUNCTION
Press TARE to cancel out or “zero” the weight on the scale.
Loading...
+ 12 hidden pages