Bogen SBA225 Datasheet

Room Selector
Models SBA225 &
eatures
F
Description
Panels
SBA325
• Color-coded guidelines
• Built-in LED annunciators
• Space-saving design
• Modular versatility
The Bogen Models SBA225 and SBA325 Room Selector Panels are designed for use with Bogen Multi­Graphic® and Multicom 2000® Systems.The SBA225 is also used in Bogen’s PI35A and SI35A Power Intercom systems. These panels provide call annunciation (using LEDs) and tone signal in addition to room selection.
The panels use three position, four-pole lever-action switches with positive detents. In the SBA225, these switches are used to selectively connect up to 25 speaker-equipped locations to either a PROGRAM, OFF or INTERCOM channel. In the SBA325, switches selectively connect up to 25 speaker-equipped locations to either a PROGRAM–A, OFF, or PRO­GRAM–B channel. ed by means of separate push on/off switches.
The INTERCOM channel is select
the
SBA225
SBA325
Each selector panel also has provisions for accommo­dating the add-on Bogen Model TZMA Time Zone Module Adapter, providing up to six zones of time sig­nalling, and/or the Model SCR25A Call-In Module, pro­viding the circuits necessary when using call origination switches which do not contain silicon-controlled recti­fiers.
-
e lo
ensur reliability.
w contact r
esistance and consistent operating
e proper
Channels ar lines in accordance with the Multi-Graphic operating method.
Calls fr depr
esponding LED
corr tone signal to bring attention to the call. The LED
emains
r time it is automaticall
The room selector panels permit maximum room selection to be accommodated in a minim
e clearly identified with color-coded guide-
om staff stations are initiated by a momentary
ession of a call origination switch, which lights the
on the selector panel and sounds a
“on” until the call is acknowledged, at which
y cancelled.
um of space
Switch handles ar shafts, eliminating troublesome r Further assurance of trouble-free operation is provid­ed by the LEDs, which are designed to give years of effi­cient ser
.
vice
Specifications subject to change without notice. ©
1995 Bogen Communications, Inc.
Part No. 54-7857-02C Printed in U.S.A. 05
e permanently affixed to the switch
eplacement pr
.
11
oblems.
echnical
T
Specifications
Switches: 25 each, 3-position, four-pole lever action with positive detents, self-wiping
with precious metal contact surfaces SBA325 includes 25 push-on/off intercom switches
LEDs: 25 red LEDs provided
inish:Panels finished in black with color coded guidelines
F
Termination: Mass termination via centerline connectors
Dimensions:
SBA225 – 1 rack space; 19"W x 1-3/4"H x 2"D SBA325 – 2 rack spaces; 19"W x 3-1/2"H x 4"D
Shipping Weight:
SBA225 – 4 lbs. SBA325 – 6 lbs.
Associated Equipment: Bogen Model SCR25A Call-In Module
Bogen Model TZMA Time Zone Module Bogen 25-Series Centerline Connector Kit
Architect
and Engineer
Specifications
The Room Selector Panel shall be a Bogen Model _________ (enter SBA225 or SBA325), or approved equal.
– Use the following 2 paragraphs for SBA225 –
The panel shall be capable of connecting up to 25 speaker-equipped locations to a program, off or inter­com channel. The panel shall provide 25 lever-action three-position, four-pole selector switches with posi­tive detents and 25 red LEDs.
Switch positions shall be legibly identified as PRO­GRAM A, OFF and INTERCOM C, each with a color­coded guideline in accordance with the operating method used in Bogen Multi-Graphic Systems.
– Use the following 3 paragraphs for SBA325 –
The panel shall be capable of connecting up to 25 speaker-equipped locations to either of two program channels,
or to an inter
off,
com channel. The panel shall provide 25 lever-action three-position four-pole switches with positive detents, 25 push on/off intercom channel selector s
witches and 25 r
ed LEDs.
Switch positions shall be legibly identified as PROGRAM–A, PROGRAM–B, and OFF O. The inter­com channel switches shall be labeled I/C. Each chan­nel shall have a color-coded guideline in accordance with the operating method used in Bogen Multi­Graphic Systems.
– Use the remaining paragraphs for both panels –
The individual switches shall be designed for maximum reliability and a life expectancy of over 250,000 opera­tions. Switches which have a lower life expectancy shall not be accepted. Switch handles shall be permanently affixed to the levers. Knobs and handles held in place by friction will not be accepted. Switches shall be self­wiping with precious metal contact surfaces.
The annunciator system shall provide for automatic call cancellation, and shall operate on less than 15VDC to eliminate any shock hazard. Annunciator systems which do not provide automatic call cancellation, or which use holding relays or other mechanical devices will not be accepted.
The room selector panel shall provide for the ready accommodation of add-on TZMA Time Zone Module and/or SCR25A
Call-In Module
.
opriate
The ann
unciator system shall illuminate the a LED and sound a tone signal when a call is placed fr a staff station. The call shall be acknowledged b ing the a
opriate inter
ppr
com selector s
ppr
witch,
y pr
which
om
ess
shall cause the LED to flash to remind the operator that the channel is open.
-
50 Spring Street, Ramsey,New Jersey 07446, U.S.A. 20
1-934-8500 • Fax: 201-934-9832 • www.bogen.com
Loading...