NQ-A4060,
NQ-A4120,
NQ-A4300
Audio Power
Ampliers
Installation
and Use
The Nyquist Power
Ampliers decode audio content distributed by the Nyquist
application and levels for loudspeaker drive. The ampliers act
as paging and public address endpoints for any source on the
network.
Each networked audio power amplier is a 2RU high enclosure
containing four Class D audio power amplier channels,
a universal switched-mode power supply, a USB port, one
RJ45 network jack, and pluggable Phoenix style terminals
for both low and high impedance loudspeakers and Line-Out
connections. Optionally, the Line-Out can be connected using
the available XLR connector.
This equipment is not suitable for use in locations
where children are likely to be present.
Equipment is intended for use
only in a restricted access area.
WARNING: To reduce the risk of re or electric shock, do not
expose this apparatus to rain or moisture.
Publication Number 740-00055A
1807
Page 2
Avertissement: pour réduire le risque d’incendie ou de choc
électrique, ne pas exposer cet appareil sous la pluie et
l’humidité.
The apparatus shall not be exposed to dripping or splashing
and that no objects lled with liquids, such as vases, shall be
placed on apparatus.
L’appareil ne doit pas être exposé aux écoulements ou aux
éclaboussures et aucun objet ne contenant de liquide, tel
qu’un vase, ne doit être placé sur l’objet.
The mains plug is used as disconnect device. The mains plug
of apparatus should not be obstructed OR should be easily
accessed during intended use. To be completely disconnect
the power input, the mains plug of apparatus shall be
disconnected from the mains.
La prise du secteur est utilisé pour déconnecter le système.
La prise du secteur ne doit pas être obstruée ou doit être
facilement accessible pendant son utilisation. Pour être
complètement déconnecté de l’alimentation d’entrée, la prise
doit être débranchée du secteur.
6. DO NOT install near any heat sources such as radiators, heat
registers, stoves, or other apparatus (including ampliers)
that produce heat.
7. DO NOT defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades with
one wider than the other. A grounding-type plug has two
blades and a third grounding prong. The wide blade, or the
third prong, are provided for your safety. If the provided
plug does not t into your outlet, consult an electrician for
replacement of the obsolete outlet.
8. Protect the power cord from being walked on and/or
pinched, particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
9. Only use attachments/accessories that are specied by the
ampliers) that produce heat.
10. Unplug this apparatus during lightning storms or when
unused for long periods of time.
11. Refer all servicing to qualied service personnel. Servicing is
required when the apparatus has been damaged in any way,
such as power-supply cord or plug is damaged, liquid has
been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not
operate normally, or has been dropped.
WARNING:
The apparatus shall be connected to a mains
socket outlet witha protective earthing connection.
To reduce the risk of re or electric shock, do not
expose this apparatus to rain or moisture.
The apparatus shall not be exposed to dripping or
splashing and no objects lled with liquids, such as
vases, shall be placed on the apparatus.
1. Ensure the POWER switch is in the off position.
2. Connect the universal mains power line cord into the amplier.
3. Connect a Cat5 type cable into the amplier’s Ethernet port
and ensure the other end of the cable is correctly connected
to your network.
4. Set the Amplier Mode switch to either 70/25V 8Ω (Bridged),
or 25V, 8Ω or 4Ω (2 Channel mode). The default is 2 Channel
mode.
Bridged mode is typically used when higher power, single
channel operation with a high impedance loudspeaker
load is desired. A typical use-case would be for 70V or 25V
loudspeaker runs, where the total load is no less than 8Ω.
2 Channel mode is typically used for 8Ω or 4Ω loudspeakers
or 25V loudspeaker runs. This mode allows the two amplier
channels to run independently.
5. Connect the loudspeaker wires to the Amplier Output
Terminals, which are labeled A +/-, B +/-, C+/-, and D+/-, as
appropriate for the desire mode of operation (see Figures 1
& 2.).
Bridged mode operation requires the speaker wires to
be connected across a single, different terminal on each
channel (A+ and B- and/or C+ and D-). (See Figure 1.) If two
channel mode is used, then Channel A is connected to A+ and
A- terminals, Channel B is connected to B+ and B- terminals,
Channel C is connected to C+ and C- terminals, and Channel D
is connected to D+ and D- terminals. (See Figure 2.)
Failure to observe minimum speaker impedance will cause
the amplier to self protect until the speaker conguration
is corrected.
6. If using the Line Input, you can route the signal to any paging
zone or station.
This balanced line level input can accept analog inputs up to
2V RMS. You can use either XLR or Phoenix (but not both)
as the input.
7. Plug the power line cord into the power source.
8. Toggle the Power switch to the On position.
For information about conguring the amplier for the Nyquist
system, refer to the Nyquist Power Ampliers Conguration Manual.
Power Ratings
The NQ-A4300 can provide 300 Watts by four channels (A, B,
C, and D) into 25V, 8Ω, or 4Ω loads, or 600 Watts Bridged (two
channels – A+B Bridged and/or C+D Bridged) into 70V, 25V, or
8Ω load congurations.
The NQ-A4120 can provide 120 Watts by four channels (A, B,
C, and D) into 25V, 8Ω, or 4Ω loads, or 120 Watts Bridged (two
channels – A+B Bridged and/or C+D Bridged) into 70V, 25V, or
8Ω load congurations.
The NQ-A4060 can provide 60 Watts by four channels (A, B,
C, and D) into 25V, 8Ω, or 4Ω loads, or 120 Watts Bridged (two
channels – A+B Bridged and/or C+D Bridged) into 70V, 25V, or
8Ω load congurations.
NOTE: This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to Part 15
of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
The NQ-A4120, the NQ-4060, and the NQ-4300 are warranted to be free from
defects in materials and workmanship for ve (5) years from the date of sale
to the original purchaser. Any part of the product covered by this warranty
that, with normal installation and use, becomes defective (as conrmed by
Bogen upon inspection) during the warranty period will be repaired or replaced
by Bogen, at Bogen’s option, with new or refurbished product, provided the
product is shipped insured and prepaid to: Bogen Factory Service Department:
4570 Shelby Air Drive, Suite 11, Memphis, TN 38118, USA. Repaired or replacement product(s) will be returned to you freight prepaid. This warranty does not
extend to any of our products that have been subjected to abuse, misuse, improper storage, neglect, accident, improper installation or have been modied
or repaired or altered in any manner whatsoever, or where the serial number or
date code has been removed or defaced.
THE FOREGOING LIMITED WARRANTY IS BOGEN’S SOLE AND EXCLUSIVE
WARRANTY AND THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY. BOGEN
MAKES NO OTHER WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED
TO THE MAXIMUM EXTENT ALLOWABLE BY LAW. Bogen’s liability arising out
of the manufacture, sale or supplying of products or their use or disposition,
whether based upon warranty, contract, tort or otherwise, shall be limited to
the price of the product. IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
LIMITED TO, LOSS OF PROFITS, LOSS OF DATA OR LOSS OF USE DAMAGES)
ARISING OUT OF THE MANUFACTURE, SALE OR SUPPLYING OF PRODUCTS,
EVEN IF BOGEN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES. Some States do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation or exclusion
may not apply to you. This warranty gives you specic legal rights, and you
may also have other rights which vary from State to State.
Products that are out of warranty will also be repaired by Bogen Factory Ser-
vice Department -- same address as above or call 201-934-8500, at owner’s
expense. Returned products which do not qualify for warranty service, may be
repaired or replaced at Bogen’s option with a previously repaired or refur-
bished items. The parts and labor involved in these repairs are warranted for
90 days when repaired by the Bogen Factory Service Department. All parts
and labor charges as well as shipping charges will be at the owner’s expense.
All returns require a Return Authorization number. For most efcient warranty
or repair service, please include a description of the failure.