NQ-A4060, NQ-A4120, NQ-A4300 Audio Power Ampliers Installation and Use
The Nyquist Power
Ampliers decode audio content distributed by the Nyquist application and levels for loudspeaker drive. The ampliers act
as paging and public address endpoints for any source on the network.
Each networked audio power amplier is a 2RU high enclosure containing four Class D audio power amplier channels,
a universal switched-mode power supply, a USB port, one
RJ45 network jack, and pluggable Phoenix style terminals
for both low and high impedance loudspeakers and Line-Out connections. Optionally, the Line-Out can be connected using
the available XLR connector.
This equipment is not suitable for use in locations
where children are likely to be present.
Equipment is intended for use
only in a restricted access area.
WARNING: To reduce the risk of re or electric shock, do not expose this apparatus to rain or moisture.
Publication Number 740-00055A
1807
Page 2
Avertissement: pour réduire le risque d’incendie ou de choc électrique, ne pas exposer cet appareil sous la pluie et l’humidité.
The apparatus shall not be exposed to dripping or splashing and that no objects lled with liquids, such as vases, shall be
placed on apparatus.
L’appareil ne doit pas être exposé aux écoulements ou aux éclaboussures et aucun objet ne contenant de liquide, tel qu’un vase, ne doit être placé sur l’objet.
The mains plug is used as disconnect device. The mains plug
of apparatus should not be obstructed OR should be easily
accessed during intended use. To be completely disconnect the power input, the mains plug of apparatus shall be disconnected from the mains.
La prise du secteur est utilisé pour déconnecter le système. La prise du secteur ne doit pas être obstruée ou doit être facilement accessible pendant son utilisation. Pour être complètement déconnecté de l’alimentation d’entrée, la prise doit être débranchée du secteur.
1200 MacArthur Blvd. Suite 304, Mahwah, NJ 07430
1-800-999-2809
© Copyright 2018, Bogen Communications, Inc.
2
Page 3
When rack-mounted, allow 1RU spacing (1.75 inches) between
units for proper ventilation.
- Lorsqu’il est monté en rack, permettez l’espace de 1RU (1.75 pouces) entre les unités pour une ventilation adéquate.
The ventilation should not be impeded by covering the venti­lation openings with items, such as newspapers, table-cloths, curtains, etc.
- il convient que l'aération ne soit pas gênée par l'obstruction des ouvertures d'aéra
No naked ame sources, such as lighted candles, should be
placed on the apparatus.
- il convient de ne pas placer sur l'appareil de sources de
ammes nues, telles que des bougies allumées
The use of apparatus in moderate climates.
- si l'appareil est destiné à être utilisé sous un climat tempéré.
Important Safety Information
WARNING: To reduce the risk of re or electric shock, do not expose this apparatus to rain or moisture.
Always comply with the following basic safety precautions when installing and using the unit:
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Clean only with dry cloth.
1200 MacArthur Blvd. Suite 304, Mahwah, NJ 07430
1-800-999-2809
© Copyright 2018, Bogen Communications, Inc.
3
Page 4
6. DO NOT install near any heat sources such as radiators, heat
registers, stoves, or other apparatus (including ampliers)
that produce heat.
7. DO NOT defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade, or the third prong, are provided for your safety. If the provided
plug does not t into your outlet, consult an electrician for
replacement of the obsolete outlet.
8. Protect the power cord from being walked on and/or pinched, particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
9. Only use attachments/accessories that are specied by the ampliers) that produce heat.
10. Unplug this apparatus during lightning storms or when unused for long periods of time.
11. Refer all servicing to qualied service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has
been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not
operate normally, or has been dropped.
WARNING:
The apparatus shall be connected to a mains socket outlet witha protective earthing connection.
To reduce the risk of re or electric shock, do not
expose this apparatus to rain or moisture.
The apparatus shall not be exposed to dripping or
splashing and no objects lled with liquids, such as vases, shall be placed on the apparatus.
Where the mains plug or an appliance coupler is
used as the disconnect device, the disconnect
device shall remain readily operable.
1200 MacArthur Blvd. Suite 304, Mahwah, NJ 07430
1-800-999-2809
© Copyright 2018, Bogen Communications, Inc.
4
Page 5
Installation
To install the Power Amplier:
1. Ensure the POWER switch is in the off position.
2. Connect the universal mains power line cord into the amplier.
3. Connect a Cat5 type cable into the amplier’s Ethernet port
and ensure the other end of the cable is correctly connected to your network.
4. Set the Amplier Mode switch to either 70/25V 8Ω (Bridged),
or 25V, 8Ω or 4Ω (2 Channel mode). The default is 2 Channel
mode.
Bridged mode is typically used when higher power, single channel operation with a high impedance loudspeaker
load is desired. A typical use-case would be for 70V or 25V loudspeaker runs, where the total load is no less than 8Ω.
2 Channel mode is typically used for 8Ω or 4Ω loudspeakers or 25V loudspeaker runs. This mode allows the two amplier
channels to run independently.
5. Connect the loudspeaker wires to the Amplier Output
Terminals, which are labeled A +/-, B +/-, C+/-, and D+/-, as
appropriate for the desire mode of operation (see Figures 1 & 2.).
Bridged mode operation requires the speaker wires to be connected across a single, different terminal on each
channel (A+ and B- and/or C+ and D-). (See Figure 1.) If two
channel mode is used, then Channel A is connected to A+ and A- terminals, Channel B is connected to B+ and B- terminals, Channel C is connected to C+ and C- terminals, and Channel D is connected to D+ and D- terminals. (See Figure 2.)
1200 MacArthur Blvd. Suite 304, Mahwah, NJ 07430
1-800-999-2809
© Copyright 2018, Bogen Communications, Inc.
5
Page 6
Figure 1. Bridged Wiring
1200 MacArthur Blvd. Suite 304, Mahwah, NJ 07430
© Copyright 2018, Bogen Communications, Inc.
6
1-800-999-2809
Page 7
Figure 2. Two-Channel Wiring
1200 MacArthur Blvd. Suite 304, Mahwah, NJ 07430
© Copyright 2018, Bogen Communications, Inc.
7
1-800-999-2809
Page 8
Notice
Failure to observe minimum speaker impedance will cause
the amplier to self protect until the speaker conguration
is corrected.
6. If using the Line Input, you can route the signal to any paging zone or station.
This balanced line level input can accept analog inputs up to
2V RMS. You can use either XLR or Phoenix (but not both)
as the input.
7. Plug the power line cord into the power source.
8. Toggle the Power switch to the On position.
For information about conguring the amplier for the Nyquist
system, refer to the Nyquist Power Ampliers Conguration Manual.
Power Ratings
The NQ-A4300 can provide 300 Watts by four channels (A, B, C, and D) into 25V, 8Ω, or 4Ω loads, or 600 Watts Bridged (two channels – A+B Bridged and/or C+D Bridged) into 70V, 25V, or 8Ω load congurations.
The NQ-A4120 can provide 120 Watts by four channels (A, B, C, and D) into 25V, 8Ω, or 4Ω loads, or 120 Watts Bridged (two channels – A+B Bridged and/or C+D Bridged) into 70V, 25V, or 8Ω load congurations.
The NQ-A4060 can provide 60 Watts by four channels (A, B, C, and D) into 25V, 8Ω, or 4Ω loads, or 120 Watts Bridged (two channels – A+B Bridged and/or C+D Bridged) into 70V, 25V, or 8Ω load congurations.
1200 MacArthur Blvd. Suite 304, Mahwah, NJ 07430
1-800-999-2809
© Copyright 2018, Bogen Communications, Inc.
8
Page 9
Viewing and Understanding LEDs
Two LEDs appear on the front of the
amplier. One is labeled POWER
and appears as solid red during initial
power up, ashes green during a boot sequence, and appears solid green
when fully booted.
The STATUS LED uses the following indicators to provide information
about the appliance:
Flashing red – No network con-
nection found.
Solid blue – The ampli-
er is in an uninitialized
state and is not associated
to a server. (The server may be in a discovery mode.)
Solid green – The amplier is registered to a Nyquist server
and is in normal operation.
Flashing green – The amplier has an IP address but is not
registered with the Nyquist server.
Solid red – The amplier needs to be rebooted or reset so
that the Nyquist application can resume.
Flashing blue – The amplier is updating.
1200 MacArthur Blvd. Suite 304, Mahwah, NJ 07430
1-800-999-2809
© Copyright 2018, Bogen Communications, Inc.
9
Page 10
Clipping, Protection, and Temperature Indicators
In addition to the LEDs that appear on the actual appliance,
separate amplier module signal clipping, protection mode,
and temperature status indicators appear in the Nyquist
amplier’s web-based user interface. For more information
about these status indicators, refer to the Nyquist Audio Power
Ampliers Conguration Manual.
Using the Reset Button
The Reset button allows you to
restart the appliance or to reset
the appliance’s conguration
settings to the factory default settings. For more information
about resetting conguration
settings, refer to the Nyquist
Audio Power Ampliers Conguration Manual.
Notice
Every effort was made to ensure that the information in this manual was complete and accurate at the time of printing; how-
ever, all information is subject to change.
1200 MacArthur Blvd. Suite 304, Mahwah, NJ 07430
1-800-999-2809
© Copyright 2018, Bogen Communications, Inc.
10
Page 11
Compliance
NOTE: This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reason­able protection against harmful interference when the equip­ment is operated in a commercial environment. This equip­ment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc­tion manual, may cause harmful interference to radio commu­nications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
1200 MacArthur Blvd. Suite 304, Mahwah, NJ 07430
1-800-999-2809
© Copyright 2018, Bogen Communications, Inc.
11
Page 12
Limited Warranty, Exclusion of Certain Damages
The NQ-A4120, the NQ-4060, and the NQ-4300 are warranted to be free from
defects in materials and workmanship for ve (5) years from the date of sale
to the original purchaser. Any part of the product covered by this warranty
that, with normal installation and use, becomes defective (as conrmed by Bogen upon inspection) during the warranty period will be repaired or replaced by Bogen, at Bogen’s option, with new or refurbished product, provided the product is shipped insured and prepaid to: Bogen Factory Service Department: 4570 Shelby Air Drive, Suite 11, Memphis, TN 38118, USA. Repaired or replace­ment product(s) will be returned to you freight prepaid. This warranty does not extend to any of our products that have been subjected to abuse, misuse, im­proper storage, neglect, accident, improper installation or have been modied
or repaired or altered in any manner whatsoever, or where the serial number or date code has been removed or defaced.
THE FOREGOING LIMITED WARRANTY IS BOGEN’S SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY. BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND, EITHER EXPRESS OR IM­PLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW. Bogen’s liability arising out
of the manufacture, sale or supplying of products or their use or disposition, whether based upon warranty, contract, tort or otherwise, shall be limited to
the price of the product. IN NO EVENT SHALL BOGEN BE LIABLE FOR SPE­CIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS, LOSS OF DATA OR LOSS OF USE DAMAGES) ARISING OUT OF THE MANUFACTURE, SALE OR SUPPLYING OF PRODUCTS, EVEN IF BOGEN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAM­AGES OR LOSSES. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specic legal rights, and you
may also have other rights which vary from State to State.
Products that are out of warranty will also be repaired by Bogen Factory Ser-
vice Department -- same address as above or call 201-934-8500, at owner’s expense. Returned products which do not qualify for warranty service, may be repaired or replaced at Bogen’s option with a previously repaired or refur-
bished items. The parts and labor involved in these repairs are warranted for 90 days when repaired by the Bogen Factory Service Department. All parts
and labor charges as well as shipping charges will be at the owner’s expense.
All returns require a Return Authorization number. For most efcient warranty
or repair service, please include a description of the failure.
7/2018
1200 MacArthur Blvd. Suite 304, Mahwah, NJ 07430
1-800-999-2809
© Copyright 2018, Bogen Communications, Inc.
12
Loading...