Rated Output
Program 35W RMS
Intercom 20W RMS
Frequency Response
Program +1,-3 dB from 80 Hz to 15 kHz
Intercom Shaped for maximum intelligibility
Distortion Less than 1% @ RPO and bandwidth
Inputs Two Lo-Z balanced microphones; Hi-Z unbalanced AUX;TELCO PAGE; 25V BOOSTER
Output 25V balanced line
Controls
Front Panel Program Selection: MIC 1, MIC 2, AUX
Level: MONITOR/LISTEN, PROGRAM
Distribution:ALL ROOMS, EMERGENCY PAGE, PRESS TO TALK
Indicators: PROGRAM/TALK LEVEL
Rear Panel Input Gain: MIC 1, MIC 2,AUX,TELCO PAGE, TALK, LISTEN
Internal Gain: Emergency Page, Supervisory Tone,Time Tone; Enable/Disable: MIC1/CONSOLE MIC,
MIC 2/TELCO PAGE, Phantom Power, Supervisory Tone
Tone Specifications Time Tone – 750 Hz; Supervisory Tone – Repeating, 500 Hz; Call-in Tone – Repeating, oscillates
between 500 Hz and 750 Hz (Switching Frequency, 16 Hz)
Power Requirements 120V, 60Hz AC, 100W maximum
Dimensions 19" W x 3-
1
/2" H x 10" D • 2 Rack spaces
Weight Approximately 10 lb.
Operating Temperature 0º - 130º F
Optional Equipment: Model MCP-EXP Input Expander Panel, Model TWK351 adapter
Technical
Specifications
Architect &
Engineer
Specifications
50 Spring Street, Ramsey, NJ 07446, U.S.A.
201-934-8500; FAX: 201-934-9832
www.bogen-es.com
The intercom/program distribution control panel shall be a
Bogen Model MCP35A, or approved equivalent, engineered
for optimum simplicity of operation, made possible by the
use of function-identified push buttons with associated colorcoded guidelines, and supported by step-by-step instructions
permanently printed on the front panel.
Control panels,which are complicated to operate and do not
provide push-button operation, color-coded guidelines, and
operating instructions printed on the front panel shall not be
considered. The intercom shall be designed for continuous
duty service in institutional and industrial applications on line
voltages of 120V, 60 Hz AC, over a temperature range of 0º
F to 130º F. Power consumption, at rated output, shall not
exceed 100 watts.
It shall include two separate amplifiers.The program amplifier shall be capable of producing 35 watts RMS at less than 1%
distortion at rated power and bandwidth. The frequency
response shall be within +1,-3dB from 80 Hz to 15 kHz.The
intercom amplifier shall have an output rating of 20 watts
RMS; frequency response shall be shaped for maximum intelligibility. Both amplifiers shall have a balanced 25V line output.
It shall include inputs for two Lo-Z balanced microphones,
one Hi-Z unbalanced auxiliary input, telephone paging accessories, and booster amplifier. Terminals shall be provided to
activate the time signal feature and telco page feature.
It shall provide all controls necessary for two-way intercom
communication with any classroom, distribution of general
announcements or program material to any or all classrooms, and transmission of emergency announcements to all
classrooms.Provisions shall be included to permit emergency
paging from a remote telephone, interphone or microphone,
which shall capture system priority and override all functions
except for the emergency page feature.
Screwdriver-adjustable, rear-panel mounted controls shall be
provided to adjust the input gain of the program sources,
telco page line, talk, and listen functions. Internal controls
shall be provided to adjust the emergency page volume,
supervisory tone volume, time tone volume,and to enable or
disable the supervisory tone and phantom power to microphone inputs. Facilities for aural (monitor speaker) and visual (LED) monitoring of program material shall be provided.
It shall include facilities for voice-call origination from classrooms and for selective classroom privacy; the latter shall
prevent the control center from monitoring any classroom
whose call origination switch is in the “Privacy” position.
Provisions are included for optional call-in using 2-conductor
shielded cable.
The Master Control Panel shall require 2 rack spaces, measure 19" W x 3-
1
/2" H x 10" D and weigh approximately 10 lb.
The control panel shall be finished in black.All program channel guidelines shall be amber; all communications channel
guidelines shall be green. The emergency page push button
shall be red.
The above equipment shall be the product of a United States
company of established reputation that has been regularly
engaged in the design and manufacture of School Sound and
Communications Systems for at least 30 years. The system
shall be supplied and/or installed by or under the direct
supervision of an authorized local distributor who has been
trained by the manufacturer in the proper installation, operation and service of the equipment.