Boge RATIO Operating Instructions Manual

Operating instructions
RATIO compressor control for screw compressors
Before installing or starting the compressor for the first time, this manual should be studied carefully to obtain a clear knowledge of the unit and of the duties to be performed while operating and maintaining the unit.
RETAIN THIS MANUAL WITH UNIT. This technical manual contains IMPORTANT SAFETY DATA and should be kept with the air compressor at all times.
Index
BOGE – RATIO compressor control for screw compressors
Inhalt.pm6.5 - USA
Page I
Operating instructions RATIO compressor control for screw compressors
Issue: 09/2009
No. 596.0840.18
Nominal price: US $ 5.00
BOGE KOMPRESSOREN Postfach 10 07 13 D-33507 Bielefeld Germany
Otto-Boge-Straße 1–7 D-33739 Bielefeld
Phone: ++49 / 52 06 / 6 01-0 Fax: ++49 / 52 06 / 6 01-200 Mail: info@boge.com Net: www.boge.com
Page II BOGE – RATIO compressor control for screw compressors
Inhalt.pm6.5 - USA
Index
Index
BOGE – RATIO compressor control for screw compressors
Inhalt.pm6.5 - USA
Page III
Index
1.1 The BOGE control ........................................................................1.1
General .......................................................................................... 1.1
Microcontroller................................................................................ 1.1
1.2 The BOGE control concept .........................................................1.2
Operating and control panel ...........................................................1.2
1.3 Operating elements......................................................................1.3
1.4 Operation ......................................................................................1.6
Parameterization of frequency converter without running motor .. 1.11
1.5 Control Parameterization ........................................................... 1.12
Error key table .............................................................................. 1.12
General ........................................................................................ 1.13
Parameterization ..........................................................................1.13
Enter Parameterization Code .......................................................1.13
Set the compressor servicing interval and restart ........................ 1.13
Set the motor servicing interval and restart .................................. 1.14
Set load cycles dependent servicing / inspection and restart .......1.14
Change target pressure values (P
max
and P
min
) ............................. 1.14
External output enable ................................................................. 1.15
Proportional control ......................................................................1.16
Timer ............................................................................................ 1.16
Switching
Local-Remote
via key switch ........................................ 1.16
Remote On-Off control .................................................................1.17
Enable network independent ON-OFF memory (Auto-Restart) .... 1.18
Idling control for extremely short operating times
(Change after-running time) .........................................................1.18
Set continuous mode ................................................................... 1.19
Anti freeze operation (only in mode
ready for operation
) .............. 1.19
RS 485-Bus-Address ................................................................... 1.20
Parameter overview...................................................................... 1.20
1.6 Faults – General ......................................................................... 1.21
Automatic monitoring of the control systems ................................ 1.21
1.7 Fault messages of the control system ..................................... 1.22
Fault .............................................................................................1.22
Acknowledge messages............................................................... 1.22
1.8 Warning messages of the control ............................................. 1.25
Part 1: RATIO
Page IV BOGE – RATIO compressor control for screw compressors
Inhalt.pm6.5 - USA
Index
RATIO.pm6.5 - USA
Page 1.1
RATIO
BOGE – RATIO compressor control for screw compressors
These operating instructions contain a description of the RATIO con­trol system.
BOGE compressors are equipped with a modern control. RATIO, an integrated control and monitoring concept, with two objectives:
– Energy savings and thus reduction of ongoing costs. – Prolonging the service life of the compressor due to minimum wear. All programmed data is stored in a memory module (EEPROM).
Thus the stored information is even available following a power failure.
The BOGE-RATIO control adapts dynamically to the respective operating conditions. A micro-controller assumes the following three tasks:
1. Automatic selection of the most economical operating mode
The micro-controller calculates the optimum operating mode from the current operating state and a programmed ideal value, also taking into account the constant compressor system data (e.g. delivery quantity, receiver volume, motor switching cycles) as well as the current variables (e.g. compressed air consumption, supply and non-supply times, pres­sure increase and decrease speed). In order to save operating costs, it always strives for the most economical intermittent operation.
2. Automatic optimization of the motor switching cycles
The micro-controller calculates the optimum number of motor switching cycles. This protects the drive motor and prolongs the service life of the plant.
3. Automatic reminder of the maintenance intervals
The microcontroller monitors the maintenance intervals.
The BOGE control1.1
Microcontroller
General
RATIO.pm6.5 - USA
Page 1.2
RATIO
BOGE – RATIO compressor control for screw compressors
Operating and control panel
The BOGE control concept1.2
Fig. 1.1: RATIO operating panel
LC-
Display
Error:
red
Ready:
green
next information
Enter
ON
OFF
Indicator lamps
previous information
Main display
EMERGENCY OFF
RATIO.pm6.5 - USA
Page 1.3
RATIO
BOGE – RATIO compressor control for screw compressors
Operating elements1.3
Operating elements RATIO
Operating/control element Function
– Press the EMERGENCY OFF switch.
The switch engages and interrupts the control voltage. All displays are cut off from the power.
After rectifying the fault, unlock the EMERGENCY OFF switch:
– Turn the EMERGENCY OFF switch a quarter
turn clockwise. – Quit the display test by pressing OFF key . – The compressor is ready to use.
Important!
Always switch the compressor off with the OFF key. Only use EMER­GENCY OFF in an emergency!
ON key – Press the ON key:
The operating status depends on the network
pressure:
1. Network pressure greater than lower cut-in pressure. Compressor remains ready.
2. Network pressure lower than lower cut-in pressure. Compressor starts.
To switch the compressor on
OFF key If necessary, continues to run in idle until decrease
in system pressure.
To switch the compressor off
EMERGENCY OFF switch To switch off the
compressor in an emergency
Operation/Explanation
[Up] key
The key has two functions:
1. It shows the previous information, one step
backward.
2. It normally increases the parameter value.
Display selection in LC-Display
[Down] key
The key has two functions:
1. It shows the next information one step for- wards.
2. It normally reduces the parameter value.
Display selection in LC-Display
INFO key – Press the INFO key.
The display shows the main information or fault/ warning message.
Select desired main information
ENTER key – See parameterization section.For confirmation in
parameterization and acknowledge­ment of messages
RATIO.pm6.5 - USA
Page 1.4
RATIO
BOGE – RATIO compressor control for screw compressors
Operating/control element Function
The green indicator lamp indicates that the machine is ready.
Lamp = red The red indicator lamp indicates a fault.Fault
Pressure gauge or target value (network).Network pressure
display
If parameterization has been started, this symbol appears in the top left of the display.
Parameterization
Ready
Operation/Explanation
3-digit 7-segment display P:
Shown in bar with a decimal point between the second and third digit.
Displays: Pressure
Lamp = green
3-digit 7-segment display T:
In °C.Displays:
Temperature
Thermometer
Operating elements RATIO
Operating elements1.3
bar
°C
Compressed air parameterization start undergoing parameterization or frost run = blinks.
Pressure gauge system pressure (compressor).System pressure
display
RATIO.pm6.5 - USA
Page 1.5
RATIO
BOGE – RATIO compressor control for screw compressors
Operating elements1.3
Operating/control element Function
The circle stands for three functions:
1. The compressor is switched off.
2. For motor servicing period.
3. Servicing symbol (receiver inspection) (replace wearing parts).
Automatic standby.Stand by
(Automatic) idling phase.Idle
OFF or motor or receiver
Operation/Explanation
Operating elements RATIO
Output phase or output cycle.Load or load speed
Automatic mode with standby phases enabled.Automatic operating
mode selection
Automatic mode without standby phases enabled.Continuous
operation
Total motor operating hours.Total running time
Idle operating hours.Idle operation
Information on current or impending servicing.Servicing due
Energy-independent ON-OFF save function set.
Auto-Restart
(automatic restart enabled after network failure)
Remote output enable (e.g., from master control).External output
enable
Remote ON-OFF (e.g., from control panel).
Serial interface activated.
Remote On-Off Mode
Online-Mode
RATIO.pm6.5 - USA
Page 1.6
RATIO
BOGE – RATIO compressor control for screw compressors
Operating/control element Function
– After unlocking the EMERGENCY OFF switch
and turning on the supply voltage, all enablable display elements of the control appear at the same time – including the two indicator lamps.
– If standby was not saved (no Auto-Restart),
this status must first be ended by pressing the OFF switch O, before the compressor can be switched on.
– Otherwise it disappears automatically after a
set time and the compressor is on standby again without touching the controls – see also Power failure cycle protection.
Function control of display elements
Operation/Explanation
Operation RATIO
Main display RATIO
green red
green
If no fault is reported, pressing will switch on the green indicator lamp (compressor on standby) which means: the pressure control function is acti­vated – see also Remote On-Off.
Switch on the compressor
Operation1.4
– This display either appears after completion of
the network failure phase (as described under display element function control) or by pressing the i key or by scrolling via È or Ç-keys:
– The network pressure is shown at the top left
(pressure gauge 21), and at the top right the (final compression) temperature, in the centre are the two operating mode curves: the left arrow shaded (as shown here) = automatic mode selection, right = continuous operation, the circle left of this means: off here.
The symbol at the bottom left is for
setting Remote-On-Off and next to it the symbol for external output enable,
next to the right the
symbol
online
and at the extreme right at the
bottom the symbol for
cut-in-save
(Auto-Re­start). These four symbols only appear when the respective setting has been made.
RATIO.pm6.5 - USA
Page 1.7
RATIO
BOGE – RATIO compressor control for screw compressors
Operation RATIO
Operation1.4
Run-up phase
Load operation
Stand by (Ready for operation)
The run-up phase – or star phase – is automatically finished by switching the electropneumatical control into load operation and the symbol appears in the display – probably first a change to delta connection takes place 60ms after the star phase. Once the set maximum pressure is reached, the idling symbol appears. The system pressure is reduced automatically.
bar °C
!
bar °C
If required the pressure control starts the motor – if the motor spinning time is finished, the system pressure has decreased and no motor switching limitation is necessary (otherwise the idling symbol
- blinks → the idling symbol appears during the
time-controlled run-up or star phase. For a star/ delta contactor combination the following applies: the star contactor is switched on first followed by the network contactor 20ms later. The idling symbol signals the state of the electropneumatic control. Thus it also appears after reaching the set maxi­mum pressure – during the decrease phase of the system pressure.
If the network pressure (in idling mode) drops below the max. start-up back pressure and the automatic operating cycles monitoring allows it, the control unit switches the motor off and the Stand by symbol
is shown in the display. If the network pressure drops to the set minimum pressure within the idling phase, the compressor switches back to load opera­tion and the respective symbol is displayed again. If this happens shortly after having switched to stand still, it has to be waited in case of contactor connection – cf. also motor spinning time – until the compressors is switched off for 20s, to be sure that the motor stands completely still, before you may start it again. If the pressure is below the switch-on pressure this is signalled by the blinking of the Stand-by symbol until the compressor starts again.
bar °C
Operating/control element Function Operation/Explanation
RATIO.pm6.5 - USA
Page 1.8
RATIO
BOGE – RATIO compressor control for screw compressors
Operation1.4
Operation RATIO
Press -key and the segment display shows the compressor system pressure (pressure gauge 22).
Compressor system pressure
Press -key a second time and the segment display shows the total operating time in hours together with the total running time symbol: .
Total operating time
Operating times, output cycles, maintenance dead­lines, display test and Software-No.
means: 124h total running time
Press O Compressor Off and the pressure control function is deactivated and the display shows the
idling symbol.
During this time the green indicator blinks. The symbol O then appears and the green indicator lamp is extinguished.
Switch off the compressor
If the control unit detects a fault, the compressor is switched off immediately and automatically – with­out an idling phase –, the
fault
relay drops and
a digit on the right of the current pressure blinks together with the red indicator lamp.
The blinking digit indicates the detected fault (see also message key table page 1.12).
Fault messages
red
!
bar °C
Operating/control element Function Operation/Explanation
RATIO.pm6.5 - USA
Page 1.9
RATIO
BOGE – RATIO compressor control for screw compressors
Operation1.4
Operation RATIO
Press -key a fifth time and the display shows the operating time (in hours) until the compressor servicing and the Running time and Servicing sym­bols (spanner).
Press -key a sixth time and the display shows the operating time until the next Motor servicing and the symbols O (here for motor), running time and servicing (spanner).
Compressor servicing
Motor servicing
Press -key a seventh time and the display shows the 1000-output cycle servicing counter with the exponent 103 (x 1000), the Load-cycle symbol, the circle (here for receiver) and the servicing symbol (spanner), meaning the number of possible output cycles until the next receiver inspection or change of wearing parts.
Next receiver servicing/change of wearing parts depending on output cycles
means: 500hrs until the next compressor servicing
means: 1000hrs until the next motor servicing
Press -key a third time and the display shows the Idling time counter in h (hours) and the Idling symbol: .
Idling time
means: 2hrs idling time
Press -key a fourth time and the display shows the 1000-output-cycles counter with the exponent 103 (x 1000), the load cycle symbol and the circle (here: receiver).
Output-cycle­counter
means: 12 x 103 = 12000 output cycles
means: 20 x 103 = 20000 Load cycles until the next receiver servicing or change of wearing parts
Operating/control element Function Operation/Explanation
RATIO.pm6.5 - USA
Page 1.10
RATIO
BOGE – RATIO compressor control for screw compressors
Operation1.4
Operation RATIO
Press -key an eleventh time and the segment display area shows the Software-No.
Software-No.
Press -key a tenth time and the display shows all symbols and segments together with the two indicator lamps.
Display element test
red green
means Software-No. 1105
Upper target pressure (network pressure)
means: P
Max.
= 10,0 bar
(cut out pressure)
Press -key a ninth time and the segment display shows the Lower target pressure and a dash at the bottom right next to it.
Lower target pressure (network pressure)
means: P
Min.
= 9,0 bar
(cut in pressure)
Software-Version No.
0xx xxx 1xx xxx
2xx xxx
3xx xxx
Meaning
Screw compressor, all sizes Screw compressor up to 22 kW
with frequency converter Screw compressor bigger than 22 kW
with frequency converter Piston compressor
Operating/control element Function Operation/Explanation
Press -key an eighth time and the segment display shows the Upper target pressure and a dash at the top right next to it.
RATIO.pm6.5 - USA
Page 1.11
RATIO
BOGE – RATIO compressor control for screw compressors
Operation1.4
Operation RATIO
Press -key a twelfth time to return to the main display. Press -key - to watch the displays in the
reversed direction. If no key is pressed for five minutes, the main display automatically reappears.
Parameterization of frequency converter without running motor
Normally the converter is under tension as soon as the I-key (On) is pressed and the compressor motor starts. In case the frequency converter has to be parameterized during motor stand-still – you only have to press the -key – when the main display is shown – and the compressor is switched off. Then the converter supply contactor starts up and the motor remains in stand­still – the green LED is not illuminated. By pressing the O-key (Off) the converter supply contactor drops out.
Operating/control element Function Operation/Explanation
RATIO.pm6.5 - USA
Page 1.12
RATIO
BOGE – RATIO compressor control for screw compressors
Control Parameterization1.5
Error key table
Each message is automatically registered by the control, to­gether with the associated time, thus putting an overview at the disposal of BOGE-Service.
1
) adjustable
Error Meaning Compr.­No. cut-out
0 Compr. air treatment (dryer or condensate drain gives error message)
1
) 1 Final compression temperature > 110°C, 230°F X 2 Motor temperature too high X 3 Excessive current of vent. motor X 4 Incorrect direction of rotation X 5 Excessive compressor system pressure X 6 Excessive diff. pressure of intake filter 7 Excessive diff. pressure of oil filter 8 Excessive diff. pressure of oil separator 9 No output X
10 Motor servicing due 11 Compressor servicing due 12 System pressure decrease too slow 13 Frequency converter gives error message X 14 Temperature too low X
15
Suction control faulty (suction control or solenoid valve, if necessary clean proportional controller)
16 Network pressure transmitter faulty X
System pressure increases too quickly (lack of oil, oil too old or even with
17 monitoring of the rotational direction a false rotational direction cannot be X
excluded)
18 Master control tries to go below P
min
– cf parameterization "External output enable"
Previous net switch-on phase was too short (possible reasons: coil short-circuit
19 'solenoid valve', 'delta contactor' or 'ventilator contactor') automatically
increased delay time in corr. with permissible number of motor switch cycles
20 Master control tires to exceed P
max
– cf parameterization "External output enable" 21 Receiver or wearing parts inspection due 22 Not assigned here 23 Not assigned here 24 Not assigned here 25 Control unit Reconciliation error X 26 Control unit O-key does not open X 27 Control unit I-key does not open X 28 Control unit i-key does not open 29 Control unit ↵-key does not open 30 Control unit "arrow up" does not open 31 Control unit "arrow down" does not open 32 Network pressure-transmitter wire breakage X 33 Compr.system pressure-transmitter wire breakage X 34 Compr.system pressure-transmitter faulty X 35 Excessive diff. pressure return valve 36 Bus Life-Bit did not toggle 38 Current of compressor motor is too high X
RATIO.pm6.5 - USA
Page 1.13
RATIO
BOGE – RATIO compressor control for screw compressors
Control Parameterization1.5
General
The control unit calculates from the current operating data the respective best operating mode and automatically selects it. The parameters are adjustable. In order to prevent unintentional changes to pre-set parameters, these parameters are codeword-protected.
ATTENTION!
Never change the value of a parameter if you do not know what it means! This may cause incorrect behaviour of the control unit! Do not experiment with parameter settings! Always call BOGE-Service if you are unsure or have any doubts.
In general the following is applicable: If a parameterization, as described below, is started at the top right in the display the symbol appears and the set value or status blinks.
1. Display Software-No. (see Software No.).
2. Press ENTER ↵ → and the parameterization symbol is shown on the
left, followed by three zeros, the left of which blinks.
3. Press or to change the first digit.
4. Press ↵ → and now the middle zero blinks.
5. Press or to change the second digit.
6. Press ↵ → and now the right zero blinks.
7. Press or to change the third digit.
8. Press ↵ → the display will now branch off depending on the set number
– if the value is invalid the main display will reappear.
Each parameterization is automatically registered by the control, together with the associated time, thus putting an overview at the disposal of BOGE­Service.
The servicing interval memory can be set to a value between 300 and 9900 hours in one hundred hours increments as long as the interval time limit is monitored by the control – if it is not used it has to be set to 10000h, as it stops the down counter.
1. Enter Code 111 as described under coded parameterization → and the
display shows the compressor servicing interval in blinking digits (Com­pressor servicing).
2. Press the or -key to change the value in big steps.
3. Press -key to overwrite the non-volatile EEPROM with the blinking
value, and the main display reappears.
Parameterization
Enter Parameterization Code
Set the compressor servicing interval and restart
RATIO.pm6.5 - USA
Page 1.14
RATIO
BOGE – RATIO compressor control for screw compressors
Control Parameterization1.5
The motor servicing interval memory can be set to a value between 500 and 29900 hours in one hundred hours increments as long as the motor interval time limit is monitored by the control – if it is not used it has to be set to 30000 h, as it stops the down counter.
1. Enter Code 222 as described under coded parameterization → and the
display shows the compressor servicing interval in blinking digits (Motor servicing).
2. Press the or -key to change the value in big steps.
3. Press ↵-key to overwrite the non-volatile EEPROM with the blinking value,
and the main display reappears.
The output cycles servicing interval memory can be set to a value between 100,000 and 1,900,000 cycles in increments of onehundredthousand, as long as the output cycles servicing interval is monitored by the control – if it is not used it has to be set to 2,000,000 cycles as it stops the down counter.
1. Enter Code 333 as described under coded parameterization → and the
display shows the receiver inspection interval in blinking digits (receiver inspection/change of wearing parts).
2. Press the or keys to change the value in big steps.
3. Press -key to overwrite the non-volatile EEPROM with the blinking value,
and the main display reappears.
If changes are made to these target values, the value of P
min
is automatically
held or brought outside any applicable minimum hysteresis range.
1. Enter Code 360 as described under coded parameterization and the
display shows the upper target pressure value, but blinking.
2. Press or -key to change the value.
3. Press -key to overwrite the non-volatile EEPROM with the blinking value,
and the lower target pressure value apears (blinking).
4. This value can now be changed by pressing the or ↓-key.
5. Press -key to overwrite the non-volatile EEPROM with the blinking value,
and the main display reappears.
6. It is not permissible to set the bottom pressure target value below the stipulated p
min
value. In case this should be necessary please contact
BOGE-Service beforehand.
Set the motor servicing interval and restart
Set load cycles dependent servicing / inspection and restart
Change target pressure values (P
max
and P
min
)
RATIO.pm6.5 - USA
Page 1.15
RATIO
BOGE – RATIO compressor control for screw compressors
Control Parameterization1.5
If the output of a compressor is to be enabled by a higher level control unit, its parameterization must be changed as follows:
1. Enter Code 210 as described under parameterization and the display
shows from Fig. c on the left. The 'zero' at the top right blinks. This dis- play means: no additional enabling device is programmed.
2. Press ↓-key to switch to Fig. d-key to switch back. Digit One and
the bottom symbol 'external output release' are blinking. This display means: enabling device (e.g., MCS) is enabled via input 'Pressure control' (for potential-free contact) – see also 'Switching
Local/
Remote
via key switch' and 'RS485-Bus-address setting'. If the -key is
pressed during this, one of the following pictures appears e + f –: Fig. 3: The three top dashes and the 1 are blinking. The P and the three
top dashes mean, that falling below the network pressure (Manometer 21) P
min
starts a load operation, even with an open input 'Pressure control'
– number '18' is displayed and the "warning" relay is activated – thus ac­tuating the operating mode. Press ↓-key to switch to Fig. f – press to toggle back –:
Fig. 4: The falling and rising (dotted) pressure curve and digit 0 are blink­ing. This figures means that due to the open input 'Pressure control' a falling below the network pressure P
min
is possible (as e.g. at night and
over the weekend). Press -key to overwrite the non-volatile EEPROM as per the blinking
symbol, and the main display reappears. In the bottom display the symbol appears. The following applies
even with external enabling: If the upper target pressure value in the compressor is exceeded, the output will be shut off. Only when the the pressure drops to the lower target pressure value the external control resumes.
If the -key under point 2 was not pressed, press -key to change to Fig. g – press to toggle back –:
Digit Two and the two bottom symbols 'external output release' and 'on­line' are blinking. This display means: enabling device (e.g., master con­trol) is enabled via a serial interface, if the input 'external output release' is closed – see also 'Switching
Local/Remote
via key switch' and 'RS485-
Bus-address setting'.
3. Press ↓-key, if convenient (not with key switch function) to switch to Fig. h
– press to toggle back. Manometer '22' and digit 3 are blinking. This setting means that a limiting
suction pressure switch (continuous output control) is connected to the input 'Pressure control'.
4. Press -key to overwrite the non-volatile EEPROM as per the blinking
symbol, and the main display reappears. If the compressor is set for an output enabling device (e.g. mode 2), the bottom of the main display shows the appropriate Symbol . The following applies even with exter­nal enabling: If the upper target pressure value in the compressor is ex- ceeded, the output will be shut off. Only when the the pressure drops to the lower target pressure value the external control resumes.
External output enable
c
d
e
!
!
!
!
f
g
h
RATIO.pm6.5 - USA
Page 1.16
RATIO
BOGE – RATIO compressor control for screw compressors
Control Parameterization1.5
Proportional control
(not in the case of frequency regulated compressors)
Timer
The limiting suction pressure switch (min. output) of a proportional control is – in case of a single compressor (without higher-level pressure control ) – connected to the input
external output enable
– cf point 3 (external output
enable). If the proportional control is used in connection with a suitable higher- level control, the limiting suction pressure switch is connected directly to the higher-level control and this control subsequently to the input
external output
enable,
which then has to be parameterized correspondingly – cf point 2 and
3 (external output enable).
A timer can either be connected individually or in combination with a propor­tional control or a higher-level control. The parameterization has to be done according to the following table:
Timer at input 'external output enable' External output enable
alias 'Pressure control' – ...
Parameteriz. Sub-
no. parameteriz. no. single 1 0 series connection with higher-level control 1 0 and pressure control via RS485 (as e.g. Profibus DP) 2 not available series connection with limiting suction
3 not available
pressure switch for proportional control
If a key switch is switched to 'Remote' for the first time or if Code 770 was entered after the control unit was able to register a key switch, one of the figures on the left appears.
1. Number One and the symbol 'Remote On-Off' are blinking. Fig. c means, that the key switch exclusively refers to the selection of switching sources for the readiness for operation of the compressor (green LED). If this set­ting is selected, the parameterization 'Remote On-Off Switching' automati­cally appears – otherwise to be reached via Code 451.
2. Press ↓-key to switch to Fig. d-key to switch back. Number Two and the symbol 'external output release' are blinking. This figure means, that the key switch exclusively refers to the selection of control sources for the network air pressure (master control or individual pressure sensor). If this setting is selected, the parameterization 'external output release' appears automatically – otherwise to be reached via Code 210.
3. Press -key to switch to Fig. e – -key to switch back. Number Three and the symbole 'Remote On-Off' and 'external output release' are blink­ing. This figure means, hat the key switch refers either to the selection of switching sources for the readiness for operation of the compressor (green LED) or to the selection of control sources for the network air pressure (master control or individual pressure sensor). If this setting is selected, the parameterization 'external output release' appears auto­matically – otherwise to be reached via Code 210 – and 'Remote On-Off Switching' automatically appears – otherwise to be reached via Code 451.
Switching
Local-Remote
via key switch
0I
!
c
!
d
0I
!
e
RATIO.pm6.5 - USA
Page 1.17
RATIO
BOGE – RATIO compressor control for screw compressors
Control Parameterization1.5
4. Press -key to overwrite the non-volatile EEPROM as per the blinking
symbol and the corresponding additional parameterization figures, as described under the respective headlines, appear. Mode '0' does not make any sense here and is therefore not displayed.
Each time the control is activated by parameterization, afterwards a blinking time value appears, which is described under
Network independent On-Off-
memory (Auto-Restart)
. Likewise it can be changed after having selected the On-Off-memory function. This value is used as a start delay time, if the control was set to 'Remote' – via key switch or parameterization – with closed control room contact directly after a power failure. If the compressor has to be switched on and off from a control room, the parameterization has to be set to the 2nd, 3rd or 4th of the following figures:
1. Enter Code 451 as described under parameterization and the display
shows Fig. c on the left: The Zero on the top right blinks. This display means: On/off switching is only possible using the keys of the control unit.
2. Press ↓-key to switch to Fig. d –-key to switch back. Digit One and the
symbol 'Remote On-Off' are blinking. This display means: Neither the key­board of the control unit nor the serial interface but exclusively the Input for Remote On-Off switch (continuous contact) are used for cut-in and cut-out (green LED) – see also Switching
Local-Remote
via key switch.
3. Press ↓-key to switch to Fig e –↑-key to switch back. Digit Two and the
symbol ‚online‘ are blinking. This display means: the compressor is exclu­sively switched on or off via the optional serial Interface 'RS485', plug­able into the control unit – the keyboard and the input for Remote On-Off switch (continuous contact) are not considered – see also 'Switching
Local-
Remote
via key switch' and 'RS485-Bus-Address setting'.
4. Press ↓-key to switch to Fig f –↑-key to switch back. Digit Three and the
symbole 'Remote On-Off' and 'online' are blinking. This display means: The compressor is either switched on or off via the Input for Remote
On-Off switch (continuous contact) or via the optional serial Interface 'RS485', plugable into the control unit, but not by the keys of the control
unit. If the continuous contact is opened, the compressor cut out – see also Switching Local-Remote via key switch. If the continuous contact is closed, switching on/off is possible via the serial interface – see also 'Switching
Local-Remote
via key switch' and 'RS485-Bus-Address setting'.
5. Press -key to overwrite the non-volatile EEPROM as per the blinking
symbol and if the above figure is selected the main display reappears. Otherwise, the figure shown under
Network independent On-Off-Storage
(Auto-Restart)
point 3 appears.
If the compressor is set to a Remote-On-Off switch, at the bottom of the main display the corresponding symbol is shown. Then the compressor
can only be switched on/ff from Remote. The Emergency Off function is not concerned. It remains unchanged.
Remote On-Off control
c
d
e
f
!
0I
!
!
0I
!
RATIO.pm6.5 - USA
Page 1.18
RATIO
BOGE – RATIO compressor control for screw compressors
Control Parameterization1.5
Normally a compressor always assumes an OFF status directly after an electrical power failure. However, after a power failure there is an option to automatically restart the compressor with a set delay time, also acknowledged in combination with a parameterization Remote On/Off – after mains return, automatically delayed – see also power failure protection – repair. This is done as follows:
1. Enter Code 134 as described under parameterization and the display
shows Fig. c on the left: The 'line' at the top right blinks. This display means: no remembering of On-Off status (no automatic standby) after a power failure.
2. Press or -keys to switch to figure d on the left (press again to toggle
back...): The 'curve' at the top right blinks. This display means: Remember­ing of the On-Off status even after a power failure (Auto-Restart).
3. Press -key to overwrite the non-volatile EEPROM acc. to the blinking
symbol. If the top symbol was selected, the main display is shown. Other­wise figure e on the left appears: The number 120 blinks. The quotation mark symbol here stands for seconds. Press the ↑ or ↓-key to change the value.
4. Press -key to overwrite the EEPROM with the blinking value and the
main display appears with the at the bottom right.
After an output phase the compressor switches to an idling phase before decreasing the system pressure and finally switching into stand-by. For com­pressors with special ventilation an additonal after-running time is necessary to avoid the formation of condensate in the compressor. The after-running time can be adjusted as follows:
1. Enter Code 019 as described under parameterization and the display
shows Fig. c on the left: The digit (here 1) blinks. The quotation mark symbol here stands for seconds. A run-out curve is indicated on the two right positions.
2. Press the or -key to change the value. Above 119 minutes appear and
the apostrophe symbol instead of the quotation mark symbol.
3. Press -key to overwrite the non-volatile EEPROM with the blinking value,
and the main display reappears.
Enable network independent ON-OFF memory (Auto-Restart)
c
d
e
Idling control for extremely short operation times (Change after-running time)
RATIO.pm6.5 - USA
Page 1.19
RATIO
BOGE – RATIO compressor control for screw compressors
Control Parameterization1.5
If pressure drops in relatively small receiver/pneumatic network volumes must be avoided at any price, continuous operation can be set as follows – if no continuous control was parameterized in connection with a single compressor:
1. Enter Code 733 as described under parameterization and the display
shows Fig. c on the left. The shading of the left arrow blinks. This means: automatic power economy operating mode selection.
2. Press the or -key to change to Fig. d on the left. (press again to toggle
back...). The shading of the right arrow blinks. This means: continuous operation.
3. Press -key to overwrite the non-volatile EEPROM with the blinking sym-
bol, and the main display from the selected symbol appears.
The compressor is set to automatically start an idling phase – in star mode i.e. without switching on a probably existing ventilator motor – from standby when the temperature drops to below +4°C. During this phase in the main display a thermometer blinks left of the temperature display. The idling phase is finished as soon as the min. after-running time or +20°C final compression temperature are reached. This anti-freeze function can be switched off as follows:
1. Enter Code 056 as described under parameterization and the display
shows Fig. c on the left: the 'curve' left of the thermometer blinks. This display means: automatic idling phase in frost.
2. Press or -key to change to Fig. d on the left (press again to toggle
back...) The 3x dotted line left of the thermometer blinks. This display means: no automatic running phase in frost, shown by means of the right dash as to the thermometer.
3. Press -key to overwrite the non-volatile EEPROM with the blinking sym-
bol, and the main display from the selected symbol appears.
Set continuous mode
c
d
Anti freeze operation
(only in mode
ready for operation
)
c
d
RATIO.pm6.5 - USA
Page 1.20
RATIO
BOGE – RATIO compressor control for screw compressors
Control Parameterization1.5
Parameter overview
The control is already set for a bus coupler (BOGE-Bus-Address 32) for each compressor according to customer specifications – as e.g. for Profibus. If used another communication of RS485 then the following action is necesarry:
1. Enter Code 830 as described under parameterization the display shows
one of the following fig. c or d.
2. Press or -key to select the picture (bobus = BOGE-Bus, rtu = Modbus type RTU) and quit by -key. Depending upon selection one of the two following fig. appears e or f: With the BOGE-Bus only the desired address (flashing here 32) is to be selected and quit by -key, while with the Modbus-RTU after confirmation of the address (flashing here on 0 = offline) by the key ↵, if address >0, still additionally the Baud rate and the data format are adjustable as fol­lows fig. g: first the number 96 (= 9600 Baud) flashes – after confirmation by the ↵- key 8E1 flashes (8E1 = 8 data bits, parity check of Even and 1 stop bit). By means of key ↑ or ↓ then the necessary combination can be selected (n = not parity check, o = odd).
3. Press -key to overwrite the non-volatile EEPROM with the blinking value, and the main display reappears. A blinking Online symbol refers to a fault in the RS485 connection.
Code Function Page
019 Idling control for extremely short operation times 1.18 056 Anti freeze operation (only in mode
ready for operation
) 1.19 111 Set the compressor servicing interval and restart 1.13 134 Network independent ON-OFF memory (Auto-Restart) 1.18 210 External output enable 1.15 222 Set the motor servicing interval and restart 1.14
333
Set load cycles dependent servicing / inspection
1.14
and restart
360 Change target pressure values (P
max
and P
min
) 1.14 451 Remote On-Off control 1.17 733 Set continuous mode 1.19 770 Switching
Local-Remote
via key switch 1.16
830 Set RS 485-Bus-Address 1.20
RS 485-Bus-Address
!
!
c
d
!
!
!
e
f
g
RATIO.pm6.5 - USA
Page 1.21
RATIO
BOGE – RATIO compressor control for screw compressors
1.6 Faults – General
General
The tables on the following pages give information on the possible causes of operating faults and measures for their rectification.
ATTENTION!
Ensure that any work required to rectify faults is only carried out by trained personnel or specialists. Ensure that components which have a safety function are only set, repaired or exchanged by BOGE Service!
Please contact BOGE-Service at the following telephone number, if you have any questions.
770-874 -1570
All data is stored in a memory module (EEPROM). If a fault occurs while the data stored in the EEPROM is being read, the control system will react as follows:
– The compressor is switched off. – The following fault message appears in the display.
Automatic monitoring of the control systems
RATIO.pm6.5 - USA
Page 1.22
RATIO
BOGE – RATIO compressor control for screw compressors
Fault messages of the control system
The control unit registers an Error, the compressor is immediately and with­out an idling phase – automatically shutdown, the error Relay drops and on the right next to the actual pressure value there blinks a number next to the red indicator lamp:
– the blinking number indicates the registered cause (see also message
key table under error messages).
Display the message – e.g. by pressing the i-key. Press -key to cancel the display and acknowledge the message. The main display appears, if the cause for the fault was rectified.
FAULT RectificationPossible cause
Excessive final
1compression
temperature
Ambient temperature too high
Cooling unit soiled Insufficient cooling air
quantity
Insufficient oil quantity Temperature sensor defec-
tive or wire break
Employ suitable measures to improve the air inlet and ventilation in the installation room
Clean cooling unit externally Keep air inlet opening to the compressor clean;
check to ensure that any existing cooling air duct systems are adequatly dimensioned
Top up oil Replace temperature sensor or repair the wire
break
Frequency
13 converter /
motor
Motor overload! Power input too high caused by undervoltage
Insufficient cooling of motor / frequency converter
Motor soiled Excessive system pressure Network pressure P
soll
/ P
max
too high PTC resistor defective or
aged
Ensure correct voltage conditions: Constant voltage in accordance with IEC 38
Ensure better cooling of motor / frequency con­verter: improve ventilation of the installation room; Clean cooling unit and supply air filter
Clean motor cooling air supply Exchange oil separator cartridge Reduce line pressure to prevent compr. building up
a compr. load above approved max. pressure Overhaul motor
Compressed air
0pre-processing
(option)
External unit of the compressed air treatment signals malfunction
Service or repair compressed air treatment unit
Note:
This message does not lead to switch-off the com­pressor and the standard configuration
Fault
red
Acknowledge messages
RATIO
1.7
RATIO.pm6.5 - USA
Page 1.23
RATIO
BOGE – RATIO compressor control for screw compressors
Fault messages of the control system
RATIO
FAULT RectificationPossible cause
Rotational
4 direction
(option)
2 phases of power cable incorrectly poled (incorrect rotary field connected)
Change the 2 phases of the power cable
Excessive pressure due to soiled oil separator
Ball valve at compressor outlet closed
Replace oil separator cartridges
Open ball valve
Pressure limitation
5
Air relief valve does not close
Suction controller does not open
Leakage in system
Check air relief valve and replace, if necessary
Check suction controller and replace, if necessary
Check system, overcome leaks
System pressure
9 build-up
Soiled filter cartridge Defective low pressure
switch
Clean or replace cartridge Replace pressure switch
Suction filter
6 (option)
Soiled filter cartridge Defective differential
pressure switch
Replace cartridge Replace pressure switch
Oil filter
7 (option)
Soiled filter cartridge
Replace cartridge
Oil separator
8
1.7
Suction con-
15 trol defective
Vent valve / quick acting starting valve does not close
Clean valves or replace wearing parts
Ambient temperature too low
Apply anti-freeze measures
Temperature
14 too low
Network
16 pressure trans-
mitter faulty
Network pressure trans­mitter defective or wire breakage
Replace network pressure transmitter or re-establish electrical connection
RATIO.pm6.5 - USA
Page 1.24
RATIO
BOGE – RATIO compressor control for screw compressors
Fault messages of the control system1.7
Control unit
29 Key Enter
does not open
Control unit defective
Replace control unit
Control unit
25 EPROM /recon-
ciliation error
Error loading software. Control unit defective
Reload software or replace control unit
Control unit
26 Key (Off) O
does not open
Control unit defective Replace control unit
Control unit
27 Key i
does not open
Control unit defective
Replace control unit
Control unit
28 Key (ON) I
does not open
Control unit defective
Replace control unit
Control unit
30
Key does not open
Control unit defective
Replace control unit
Control unit
31
Key does not open
Control unit defective
Replace control unit
Network pressure trans­mitter defective or wire breakage
Replace network pressure transmitter or re-establish electrical connection
Network press.
32 transmitter
faulty
Master
18 control
defective
Master control defective
Check supply voltage of master control. Parameterization of external output enable
RATIO
FAULT RectificationPossible cause
System press.
33 transmitter
faulty
System pressure trans­mitter defective or wire breakage
Replace system pressure transmitter or re-establish electrical connection
System press.
34 transmitter
faulty
System pressure trans­mitter faulty
Replace system pressure transmitter
RATIO.pm6.5 - USA
Page 1.25
RATIO
BOGE – RATIO compressor control for screw compressors
Warning messages of the control1.8
WARNING RectificationPossible cause
Compressed air
0 pre-processing
(option)
Warning
Motor
10 servicing
due
Servicing intervals
See operating instructions for servicing
Compressor
11 servicing
due
Servicing intervals
See operating instructions for servicing
Receiver
21 inspection
due or replace wearing parts
Servicing intervals
Inspect receiver acc. to local rules and/or replace wearing parts
See operating instructions for compr. air pre­processing
Suction control
15 and / or
ventilation
Warning
Check suction controller Check solenoid valve Check continuous output control (option)
RATIO
RATIO.pm6.5 - USA
Page 1.26
RATIO
BOGE – RATIO compressor control for screw compressors