Boca Flasher HPCCS Installation Manual

WARNING: DO NOT LIFT FIXTURE BY CABLES.
This could result in permanent damage to both the xture and the cables. Damage resulting from grasping
cables and / or putting undue pressure on the cable connections will not be covered under the warranty!
DO NOT ATTEMPT TO INSTALL OR USE THE HPCCS FIXTURE WITHOUT READING THE INSTALLATION
INSTRUCTIONS AND SAFETY LABELS COMPLETELY.
Failure to adhere to these instructions could result in serious injury or property damage.
DO NOT MODIFY, ALTER OR ATTEMPT TO SERVICE THE HPCCS. DOING SO WILL VOID THE WARRANTY.
Installation Manual
HPCCS
INSTALLATION INSTRUCTIONS
INCLUDED IN THIS PACKAGE
Turn Power Off At Circuit Breaker Before Beginning Installation!
DO NOT LIFT FIXTURE BY CABLES!
INTRODUCTION:
The Boca Flasher’s HPCCS is perfect for color washing long runs and large areas. LEDs are spaced 1.00" apart in a two rows to create an even wide wash of light. The housing is anodized aluminum and is weather and abrasion resistant. This light xture can use any standard DMX 512 controller or can incorporate Boca Flasher’s Digital Mainframe controller (Demo Version Only). The Digital Mainframe can run independently, creating many stand-alone color washing and solid color eects, as well as responding to DMX commands for total control of your lighting experience.
MAINTENANCE:
Cleaning:
− Dry and Damp (IP65) Rated Fixtures: To clean surface use a soft damp cloth.
− Wet (IP68) Rated Fixtures: To clean surface use a soft cloth with mild soap and water. Storage: Store in a dry, well-ventilated area when
product is not in use. Keep the electrical cord away from heated surfaces when in use or not in use. If cord shows signs of damage do not use, return product to manufacturer.
Fixtures must be installed by a qualied
and licensed electrician in accordance with all
national, state and local electrical codes
and regulations. If any part of this manual
does not meet the necessary codes and regulations, contact the factory for more information before attempting to install.
ELECTRICAL SPECIFICATIONS:
1. Input Voltage: 90-120VAC or 230-277VAC (See layout drawings for spec.)
2. Total linear ft per 20A breaker: 55ft
3. Total linear ft per 15A breaker: 40ft
4. Input Current: 272mA RMS per linear ft for RGB, 272mA RMS per linear foot for WM
Page 2 of 7
HPCCS Indoor/Outdoor Line Voltage
1
2
Mounting Brackets
(2 brackets per xture)
3
HPCCS
Job Specic Drawings
Max temp: 55°C
Min. temp: -40°C
DAMP LISTING
IP65
WET LISTING
IP68
model dependent
HPCCS Fixtures
(In lengths shown on job specic drawings)
or
Fixed
Hinged
DMX Cables are 5ft long
HPCCS
INSTALLATION INSTRUCTIONS
Page 3 of 7
1. Install Fixed Clips into Substrate
1b.
1a.
3. Install Hinge Clips
3a.
3b.
Installing Hinge Clips:
Hinge clips come installed on the xture. Therefore it is easy to determine where to predrill the holes into the substrate before doing so. Installing is only a matter of drilling in the proper screws, recommended.
Screw Information:
1. Screws not provided by Boca Flasher.
2. Boca Flasher recommends wide washer at head Philips #8 screw (not to exceed .418".
3. Length of screw will vary depending on mounting surface.
4. For outdoor installations, installer should use a screw with weatherproof coating.
5. One foot xtures only require one hinge bracket.
1c.
Determine layout of xture or composition of xtures and locate appropriate clip location. CLIP MUST BE A MINIMUM OF 4.5" FROM END-CAP TO ALLOW CLEARANCE OF MOLDED CORDS.
2. Install Fixture into Fixed Clips
Angle xture into opening, pushing clip wider as you push
2a. 2b.
Clip will securely snap into place
2c.
snap!
Tab on side of clip should go in notch at the top of the xture
HPCCS
INSTALLATION INSTRUCTIONS
4. Connect DMX Cables Together (as shown on job specic drawings)
Rotate xture to see bottom and note each label.
Cross-reference with Job Specic Drawing.
Note: Contractor cannot
install more than
32 xtures
per data stream.
4a.
4b.
Push together until you hear a “Click”.
Note: Outdoor version will screw together, not click.
4d.
click!
DMX In
DMX Out
DMX In
DMX Out
Connect DMX IN on a xture with DMX out separate xture.
4c.
DMX In
DMX Out
Power Feed
Page 4 of 7
Labels on xtures correspond with
nomenclatures on drawings.
HPCCS
BF-01
The HPCCS does not daisy-chain by power.
HPCCS
INSTALLATION INSTRUCTIONS
5. Connect Fixtures to Power and Controls - Single Run Installation
Power Cable is 6.5ft per UL standard
White (Neutral)
Black (Line)
White (Neutral)
Black (Line)
Green (Ground)
Green (Ground)
Note: Contractor cannot install more
than 32 xtures per data stream.
Note: More than one
connection can be made
in each connection box.
*Note: XLR 5 pin DMX
connection standard. Cable is typically 5 ft in length. Call Factory for
more information.
RJ45 (Ethernet) to an XLR
connection is available
upon request.
(5 ft) (5 ft) (5 ft) (5 ft)
Page 5 of 7
HPCCS
INSTALLATION INSTRUCTIONS
5b. Connect Fixtures to Power - Multi Run Installation
White (Neutral)
Black (Line)
Green (Ground)
Green (Ground)
White (Neutral)
Power Cable is 6.5ft
per UL standard
Note: Contractor cannot install more
than 32 xtures per data stream.
Note: More than one connection can be made in each connection box.
(5 ft) (5 ft) (5 ft) (5 ft)
(5 ft) (5 ft) (5 ft) (5 ft)
(XLR 5-pin)
(XLR 5-pin)
*Note: XLR 5 pin DMX connection
standard. Cable is typically 5ft
in length. Call Factory for more
information. RJ45 (Ethernet) to an XLR
connection is available upon request.
Page 6 of 7
HPCCS
INSTALLATION INSTRUCTIONS
Boca Flasher, Inc.
552 NW 77th Street ■ Boca Raton, Florida ■ 33487 USA
Phone: 561.989.5338 ■ Fax: 561.982.8323
www.bocaasher.com
1. DANGER: To reduce the risk electric shock, always unplug the HPCCS from electrical outlet before
cleaning. Cut breaker if outlet is not available.
2. TO REDUCE THE RISK of burns, re, electric shock, or injury to persons
• Use the HPCCS only for its intended use as described in these instructions.
• Do not use attachments not recommended by Boca Flasher.
• Never operate the HPCCS if it has a damaged cord, cable or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. If the seal appears to be damaged/broken/torn return the xture to a service center for examination or repair.
• Keep cables away from heated surfaces
• Never drop or insert any object into any opening.
• Do not operate where aerosol (spray) products are being used or where oxygen is
being administered.
3. WARNING: Do not attempt to install or use the HPCCS without reading the installation instructions
and safety labels. Failure to adhere to these instructions could result in serious injury or property damage.
4. DO NOT MODIFY, alter, or attempt to service the HPCCS Doing so will void the warranty.
5. DO NOT USE SHARP TOOLS near or on the xture lens.
Doing so will result in property damage and void the warranty.
Important Safety Reminders
We are constantly improving our fixtures and reserve the right to change options and specifications. Additional information & details at www.bocaflasher.com. For specific requirements, contact your Boca Flasher sales representative. Boca Flasher, Inc. 552 NW 77th Street Boca Raton, Florida 33487 USA Phone: 561.989.5338 Fax: 561.982.8323 © 2015 Boca Flasher, Inc. All rights reserved. All names and trademarks are property of their respective owners. REV031815_lr
DAMP LISTING
IP65
WET LISTING
IP68