LEGEND: Obtain Dimension from Bobrick Layout Sheet.
Fig. 1a: Floor-Anchored or Ceiling-Hung
Front-Entry Corner Layout.
Fig. 1b: Overhead-Braced
Alcove Closed Layout.
NOTE: The stiles are in-line with panel.
X Dim. = Stile Edge to Centerline of Mounting Hole. Y Dim. = Centerline-to-Centerline of Mounting Hole.
Fig. 1c: Floor-Anchored or Ceiling-Hung
Alcove Closed Layout. Inswing Door.
NOTE: The center stile is perpendicular to panel.
Fig. 1d: Floor-Anchored or Ceiling-Hung
Alcove Closed Layout. Outswing Door.
NOTE: The center stile is perpendicular to panel.
A. Refer to Bobrick layout sheets for component locations on your specific application.
B. From back wall, measure and mark the location of the stile centerline. Stile centerline = 1/2" (13mm) + panel length + gaps
specified on layout sheets.
C. From side wall and center of stile location, measure dimensions for floor or ceiling anchors according to layout sheet. Refer
to the drilling tables below for center-to-center distances between anchors. For example: Overhead-Braced stiles centerline
of floor anchor from edge of stile is 1" (25mm); dimension on 3" (8cm) stile is 1-1/2" (38mm).
Fig. 1e: Detail of Overhead-
Fig. 1f: Detail of Floor-Anchored or Ceiling-Hung Stile
Braced Stile
Floor Anchored Stile
NOTE: 16", 18", 20", 24" (41, 51, 46, 61cm) stiles have 2 leveling bars. Use the 2 outside slots
for the 2 anchors.
Drilling Table
Overhead-Braced Series — Standard & .64 OptionFloor-Anchored Series & Ceiling-Hung StilesCeiling-Hung Series & .63 Option
A. Based on stile size locate centerline of floor L-brackets
from Drilling Table. (See page 3).
B. Drill 5/16" (8mm) diameter hole to 1-3/4" (45mm)
minimum depth. Remove all loose material from holes.
C. Install plastic anchors into holes.
D. Place one shoe retainer bracket at each hole location.
E. Place floor L-bracket on top of and inside each shoe
retainer.
F. Install #14 x 1-3/4" (M6.4 x 45mm) floor screws to retain
bottom floor L-brackets and shoe retainers. Do NOT
tighten screws. Screws should be loose enough to adjust
the floor L-brackets.
G Using the stile as a measurement tool, adjust the floor
L-brackets to fit inside the stile brackets. Mark locations.
H. Remove stile and tighten floor screws securely.
NOTE: Wood-floor anchors are available upon request. To
install drill 3/16" pilot hole in the floor and install using #14 x
1-3/4" (M6.3 x 45mm) screws.
FLOOR ANCHORS. Standard
A. Drill 3/8" (9.5mm) diameter hole to 2" (50mm) minimum
depth. Remove all loose material from holes.
B. Insert expansion shield (threaded side down) with
threaded rod into mounting hole. Extra flat washers are
supplied. Place as many flat washers as necessary onto
rod to ensure shoe retainer is placed above finished floor
surface. Install and tighten a hex nut above washer(s) and
shoe retainer, tightening and expanding anchor to secure
to floor. Make sure when tightening bolt that shoe retainer
is positioned properly to accept shoe (see Fig. 2b for
proper shoe retainer position).
C. Add a second hex nut, then a flat washer.
D. Set aside the third hex nut, flat washer, and the lock
washer. Install when stile is placed on anchor bolts.
E. Repeat process for each floor anchor.
NOTE: Wood-floor anchors are available upon request.
Fig. 2a: Detail of Overhead-Braced
Floor Anchor.
Fig. 2b: Detail of Floor Anchor.
CEILING ANCHORS.
NOTE: Ceiling anchors are to be installed before finished
ceiling is applied. All structural framing is to be furnished by
others. For Bobrick recommendations, refer to Bobrick Form
No. TB-32.
A. Drill 7/16" (11mm) diameter hole through structural
beam. Insert threaded rod through hole in beam. Rod
is furnished standard 6" (150mm) length. Longer rods
should be purchased locally if required.
B. Drop a bevel washer and lock washer over rod. Screw on
one hex nut.
C. Install second hex nut against bottom of beam and
tighten.
D. Install spacer, shoe retainer, flat washer, and a third
hex nut. Make sure shoe retainer is in proper position
to accept shoe (see Fig. 2c for proper shoe retainer
position).
E. Install remaining flat washers (2), lock washer (1), and
hex nuts (2), as shown in Fig. 2c.
F. Repeat process for each ceiling anchor.
A. Measure and mark the locations of centerlines for all
the stiles and panels on walls.
B. Using the wall brackets as templates, measure
and mark the location of all mounting holes, plumb
according to dimensions shown in illustrations (Fig.
3a, 3b, 3c).
C. Use #19 (.166) drill bit (4.2mm) for 2" (50mm) deep
pilot holes into adequate wall backing.
D. Secure wall brackets with 1002495 screws.
These mounting points require wall backing.
Obtain Dimension from Bobrick Layout Sheet.
Fig. 3b: Overhead-Braced Alcove Closed
Layout.
Fig. 3a: Front-Entry Corner Layout with
Wall Post.
WALL POST #1002250
A. Determine the location and hole of the 1" x 1-1/2"
(25 x 40mm) stainless steel wall post being installed.
Outside edge of wall post to be in-line with outside
edge of keeping stile. The wall must have adequate
backing at mounting location to support door hung in
place.
CAUTION: Panel centerline is not
always on the stile centerline. Refer
to Bobrick Layout Sheets for panel
offsets.
A. Measure and mark the centerlines
for three (3) U- or L-brackets per
stile.
B. Using U- or L-bracket as a template,
mark the location of all mounting
holes.
C. For U- or L-brackets attached to
steel-core stiles, use a high-quality
drill bit 3/16'' (4.7mm) for 3/4"
(19mm) deep pilot holes.
D. Caution: Do not drill through the
stile. For L-brackets attached to the
edge of stile, use a #19 (.166) drill
bit (4.2mm) for 3/4" (19mm) deep
pilot holes.
E. Secure U- or L-brackets
with 1002500 screws.
Fig. 5b: Overhead-Braced
Bracket Placement.
For
Internal
Panel
(Refer to
examples
on page 5.)
For
External
Alcove
In-Line
Panel
Page 7
Page 8
Stile Bracket
Floor L-Bracket
#14 x 5/8''
(6.4 x 16mm)
St. Stl.
Sheet-Metal
Screw
#14 x 1-3/4''
(6.4 x 45mm)
St. Stl. Sheet-Metal Screw
Leveling Bolt
#14-16
Plastic Anchor
Finish Face
of Floor
#14 x 5/8''
(6.4 x 16mm)
St. Stl.
Sheet-Metal
Screw
#14 x 1-3/4''
(6.4 x 45mm)
St. Stl. Sheet-Metal
Screw
#14-16
Plastic Anchor
12''
(305mmn)
Hex Nut
Flat Washers
Lock Washer
Hex Nuts
Threaded Rod
Flat Shoe Retainer
Expansion Shield
Leveling
Bar
Step A
Flat Washer
Hex Nut
Lock Washer
Flat Washers
Hex Nut
Hex Nut
Lock Washer
Flat Washers
Hex Nut
INSTALL STILES AND SET DOOR OPENINGSSTEP 6
Floor-Anchored and Ceiling-Hung Series
A. Place the stiles onto the threaded rods of anchors. Add a flat washer, lock washer, and a third hex nut to each
threaded rod of floor anchors (these should already be in place on ceiling anchors—refer back to Fig. 2b). Do not
tighten hex nuts at this time.
B. Ensure edge of panel is touching screw heads in brackets on stiles. Using brackets as templates, drill 3/16" (.187) x
5/8" (6.4 x 16mm) pilot holes in panel.
C. Fasten brackets to panels with #14 x 5/8" (6.4 x 16mm) screws or 1002500 for stainless steel option.
D. Use level to plumb stiles. Place shims between panels and wall.
E. Set door openings to be square, plumb and true per Bobrick Layout Sheets.
F. Tighten hex nuts on stile anchoring system.
G. Secure panels to wall brackets using #14 x 5/8" screws or 1002500 for stainless steel option.
Fig. 6a: Ceiling-Hung InstallationFig. 6b: Front View Ceiling-Hung Stile
Obtain Dimension from Bobrick Layout Sheet.
Overhead-Braced Series
A. Install leveling bolt into stile.
B. While stile is laying flat, rotate leveling bolt so that overall stile dimension is 82-5/16" (209cm) from the head of the
leveling bolt to the top edge of stile.
Note all floor slopes and adjust stile heights accordingly.
C. Mount stile and install #14 x 5/8" (6.4 x 16mm) screws through the side of stile bracket into the floor L-bracket. Leave
screws loose. (Fig. 6d)
D. Level and plumb the panels. Using stile U-bracket as a template, drill 3/16" (5mm) pilot holes into the panel.
Special note: U-bracket panel hole should be a minimum of 1/2" (13mm) off edge of panel.
F. Fasten U and F-brackets to panels with #14 x 5/8" (6.4 x 16mm) screws or 1002500 for stainless steel option.
G. Level and plumb stile. Tighten stile bracket screws #14 x 5/8" into floor L-bracket.
A. Using hinge diagram at left, identify the upper and lower hinge set for right hand or left hand installation. Locate
#1002156 cam for upper hinge.
B. Separate hinge sets and fasten the 2 halves that have plastic bushings with “teeth” and cam alignment tabs onto stile
using driver and (1/4-20" x 34") screws. Refer to diagram to ensure “J” and “L” halves are located properly.
C. Fasten remaining upper hinge half to door.
D. Insert hinge pin and #1002156 plastic cam on upper stile hinge half.
E. Lift door and position onto upper stile hinge half. Door should be hanging securely on upper hinge.
F. Insert remaining hinge pin in lower door and hinge half and mount to door.
To Increase or Decrease Opening of Door.
A. Alignment tabs have been formed into the cam and plastic hinge bushing.
B. Lift door to limit of upward travel (approximately 1/2"). While door is lifted, raise cam above bottom bushing and rotate
so alignment tabs meet.
C. To set door in open position, rotate cam toward door opening direction.
D. To set door in closed position, rotate cam toward door closing direction.
E. Door may not function properly if cam and bushing tabs are not aligned properly.
F. When the cam has been set at the desired free resting position, “either closed or open” the top of the affixed
components will be aligned
Tip – Industry tolerance in the hardware will sometimes allow fine alignment to some partition components.
These fine adjustments may be performed by loosening the hardware screws and adjusting the components
A. Mount latch and keepers as shown (Fig. 9f) using
1002500 (#12 x 3/4") screws.
Perpendicular Keeping Stile: Mount latch as shown
(Fig. 9g) using 1002500 (#12 x 3/4") screws for the
latch and keeper. Using keeper as template, place
keepers as shown overhanging edge of stile, to line
up with latch slide. Mark location of mounting holes.
Secure keeper using 1002500 (#12 x 3/4").
NOTE: To ensure emergency access, locate the
keepers so that the latch slide is no more than 5/16"
(8mm) into the keeper slot as shown. (Fig. 9f).
B. Mount robe hook (Fig. 9h) using 102500 (#12 x 3/4")
screws.
C. Mount inswing door bumper (Fig. 9h) to panel or door
at location that prevents door from hitting panel on the
inswing.
Fig. 9g: Perpendicular Stile Mounting
Location of Latch Keeper.
1-1/2''
Door
C
L
2''
Stile
Panel
C
L
Fig. 9f: Mounting Location of Latch,
Keeper with Emergency Access.
C
Door
L
Door
3/4''
(19mm)
3/16''
(4mm)
7/8''
(22mm)
1-7/8''
(45mm)
28-1/6''
(710mm)
Latch
Fig. 9h: Robe Hook and Bumper.
C
Panel
L
Stile
5/16''
(8mm)
Max.
Keeper
Latch
Keeper &
Door Stop
2-1/2''
Outswing
A. Mount latches and keepers as shown (Fig. 9f, 9i) using
screws 1002500 (#12 x 3/4").
NOTE: To ensure *emergency access, locate the
keeper so the latch slide is seated no more than 5/16"
(7mm) from the top of keeper (See Fig. 9i).
B. On outswing door, install the handle on outside of
door opposite the latch. Using the door handle as a
template on the outside of door, mark location for top
hole in handle 31-5/8" (803mm) up from the bottom
edge of door. Mark location for bottom hole in handle.
Drill two (2) 3/16" (5mm) diameter holes of door
using #8-32 x 1-14" one way screws provided. For
accessible compartments, latch must also be installed
on the interior.
C. Mount robe hook 1002500 (#12 x 3/4") screws.
D. Mount outswing door bumper using 1002500 (#12 x
3/4") at location that prevents door from hitting surface
on the outswing.
Fig. 9i: Mounting Location of Latch and
Keeper with Emergency Access.
B. Confirm shoe retainer (#1002413 for Overhead-Braced Series (Fig. 10) or #1002186 for Floor-Anchored or Ceiling-
Hung Series (Fig. 10) is installed on anchor bolt next to flat washer closest to floor or ceiling. For anchor assembly
detail, reference diagram on Page 4.
C. Shoes accommodate 1" thick or 3/4" thick stiles. For 1" thick stiles, orient shoe with 3/16" wide flange return against
faces and edge of stile.
D. Standard Stile Installation - See Fig. 10
Open end of shoe and slide onto bottom of stile, trapping bottom flange under shoe retainer. Close open end of shoe,
overlapping so holes are aligned. Install flat head retaining screw through double thickness of material to close shoe.
E. Remove protective covering and wipe shoe clean.
Fig. 10: Standard Stile Installation. (Overhead-Braced Anchor Shown)
REPLACEMENT SHOE GUIDE
Stile WidthBobrick Part NumberStile WidthBobrick Part Number
3"100217510"1002179
4"100217612"1002180
5"100218416"1002181
6"100217718"1002196
7"100219720"1002182
8"100217824"1002183
STEP 11
A. Remove any exposed labels from the components of toilet compartments.
FINISH AND CLEANUP
B. Clean surfaces as needed. CAUTION: Do not use cleaners containing acid on Bobrick toilet compartments.
For example, tile cleaners containing acid may attack the stainless steel hardware.