Bobrick B-700, B-708, B-770, B-778 Installation Instructions Manual

INSTALLATION INSTRUCTIONS
B-700, B-708, B-770 & B-778
SURFACE-MOUNTED
AUTOMATIC HAND DRYER
Form No. 700-69 Multi Language (Rev. 7/1/13) © 2013 Bobrick Washroom Equipment, Inc. Printed in U.S.A.
1
Finish Face of Floor
10-15/64''
260mm
S
S
33/64''
13mm
7-43/64''
195mm
Dimension
A
1-7/64''
28mm
S
9-7/16''
240mm
5/16''
8mm
3/4''
19mm
15/32''
12mm
10-3/8''
265mm
8-43/64''
220mm
3/16''
5mm
3/4''
19mm
6-1/16''
155mm
S
1''
25mm
1-3/8''
35mm
Flange Cutout for
Surface Wiring
7/8''
22mm
Dia. Hole for
Between Wall Wiring
Electrical Characteristics
Hand dryer models B-700, B-708, 115V AC, 20 Amp, 50/60 Hz, Single Phase, cULus listed; Hand dryer models B-700, B-708, 208-240V AC, 9-10 Amp, 50/60 Hz, Single Phase, cULus listed, VDE approved, CE marked.
Hand dryer models B-770, B-778, 115V AC, 12 Amp, 50/60 Hz, Single Phase, cULus listed; Hand dryer models B-770, B-778 208-240V AC, 5.5-6.3 Amp, 50/60 Hz, Single Phase; cULus listed, VDE approved, CE marked.
Recommended Mounting Heights
Distance from floor to bottom mounting screw holes of mounting base. (Dimension A)
Hand Dryer
Men's Washrooms .............................................................................................................................................................46'' (117cm)
Women's Washrooms ........................................................................................................................................................44'' (112cm)
Children's Washrooms, ages 3-9 ......................................................................................................................................32'' (81cm)
Children's Washrooms, ages 9-12 .....................................................................................................................................36'' (91cm)
Children's Washrooms, ages 12-15 ...................................................................................................................................40'' (102cm)
Children's Washrooms, ages 15-18 ...................................................................................................................................44'' (112cm)
For the Handicapped .........................................................................................................................................................38'' (97cm)
* Bobrick automatic hand dryers should be installed 15" (380mm) above any projection or horizontal surface which may interfere with
the operation of the automatic sensor.
Important
* Warm air hand dryer. Intended for use in a household environment by non-expert users. Not suitable for outdoor use. ** This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
*** If a fault develops disconnect the electrical supply, a qualified electrician should be called.
Removal of Cover
1. Start installation of dryer by removing cover. To loosen two cover bolts, insert Allen Wrench (provided with dryer) into holes located on bottom of cover on each side of air intake grille. Make sure wrench fits into head of cover bolts and turn CLOCKWISE until bolts stop turning. When cover bolts are screwed in all the way, cover can be removed.
Installation of Mounting Base
FOR PROPER ELECTRICAL CONNECTIONS, CHECK LOCAL BUILDING CODE. UNIT MUST BE INSTALLED BY A QUALIFIED LICENSED ELECTRICIAN
1. Hold the Installation Template against the wall in the desired location of the installed dryer. See recommended mounting heights above.
2. Make sure line on template representing bottom of dryer mounting base is horizontal and located at the desired height above floor.
NOTE: Surface-mounted electrical supply entry is located in the lower right corner of the mounting base. Surface-mounted supply cable should be fitted in a conduit.
3. Drill four holes for 1/4" (6.4mm) diameter mounting bolts or screws (not furnished by Bobrick).
4. Fasten mounting base securely to wall.
2
Form No. 700-69 Multi Language (Rev. 7/1/13) © 2013 Bobrick Washroom Equipment, Inc. Printed in U.S.A.
2. To remove cover, place a hand on each side of cover and push up toward top of dryer releasing cover from studs at top of
BOBRICK
mounting base. Lift cover off mounting base by
BOBRICK
pulling forward at the bottom and upward at the same time.
WARNING: TURN ELECTRICAL POWER SUPPLY OFF
MUST BE GROUNDED (EARTHED).