Technical Data
Edge of
Flange to Wall
36''
915mm
4''
100mm
39-3/4''
1010mm
57-3/4''
1465mm
50''
1270mm
Edge of
Flange to Wall
Edge of
Flange to Wall
32''
815mm
4''
100mm
39-3/4''
1010mm
27-3/4''
705mm
24''
610mm
Edge of
Flange to Wall
1¼" (32mm) DIAMETER
STAINLESS STEEL GRAB BARS
WITH SNAP FLANGE
B-5806
SERIES
Specify Finish Required:
Satin finish
Satin finish with peened gripping surface; add suffix .99 to model number
3-1/8''
80mm
End Mounting Flange
2-1/4''
55mm
1-1/2''
38mm
2''
50mm
3-1/8''
80mm
2-1/4''
55mm
Intermediate Flange
2-5/8''
65mm
Snap Flange Cover
HORIZONTAL
VERTICAL
3-1/4''
85mm
Dia.
5/16''
8mm
3-1/8''
80mm
B-5806 x 18, 24, 30, 36, 42, 48
4''
45-3/4''
1160mm
100mm
TWO-WALL
B-5897
50''
1270mm
57-3/4''
1465mm
Flange to Wall
continued . . .
S/B
Printed in U.S.A.
42''
1065mm
Edge of
Flange to Wall
TWO-WALL
TUB / SHOWER
COMPARTMENT BAR
The illustrations and descriptions herein are applicable to production as of the date of this Technical Data Sheet. Rev. 8/10/18
The manufacturer reserves the right to, and does from time to time, make changes and improvements in designs and dimensions. © 2018 by Bobrick Washroom Equipment, Inc.
B-5837
HORIZONTAL
TUB / SHOWER
COMPARTMENT BAR 24 x 36
B-58616
TOILET COMPARTMENT BAR 42 x 54
Edge of

MATERIALS:
Grab Bar — 18-8, Type-304, 18-gauge (1.2mm) stainless steel tubing with satin-finish. 1-1/4" (32mm) outside diameter. Ends are heliarc welded to concealed
mounting flanges. Clearance between the grab bar and wall is 1-1/2" (38mm).
Concealed Mounting Flanges — 18-8, Type-304, 11-gauge (3.2mm) thick, stainless steel plate; end flanges 2" x 3-1/8" (50 x 80mm) with holes for attach
-
ment to wall. Intermediate flanges 2-5/8" x 3-1/8" (65 x 80mm) wide x 3-1/8" (80mm) diameter.
Snap Flange Covers —
18-8, Type-304, 22-gauge (0.8mm) drawn stainless steel with satin-finish. 3-1/4" (85mm) diameter x 5/8" (16mm) deep. Each cover
snaps over mounting flange to conceal mounting screws.
STRENGTH:
Bobrick grab bars that provide 1-1/2" (38mm) clearance from wall can support loads in excess of 900 pounds (408kg) if properly installed. Other grab bar
configurations can support loads in excess of 250 pounds (113kg) if properly installed, complying with accessible design (including ADAAG in the U.S.A.) for
structural strength.
Safety Warning: Grab bars are no stronger than the anchors and walls to which they are attached and, therefore, must be firmly
secured in order to support the loads for which they are intended. To avoid potential injury, the building owner or maintenance
personnel should remove the grab bar from ser vice if the grab bar is not adequately secured to wall or if there is any obser ved
damage to the welds.
INSTALLATION:
Provide concealed anchor device or backing as specified or required in accordance with local building codes before wall is finished. Fasten concealed mounting
flanges to anchor device or backing with at least two screws opposing each other in each flange. Snap flange covers over each mounting flange to conceal mount
ing screws. Concealed anchor devices and mounting screws are not included with Bobrick grab bars and must be specified as an accessory.
For Grab Bars with an Intermediate Flange(s), Pull Snap-Flange Covers away fr
om mounting flanges. Place grab bar in desired mounting location. Use
intermediate flange as a template to mark location of mounting screws at intermediate flange only. Mark screw locations at the center of the slot in the middle
of the double-keyhole shaped mounting holes (2) in the intermediate flange. Remove grab bar from wall. Drive the intermediate flange mounting screws into
wall at marked locations. Note: Make sure to leave a space of just over 1/8'' (3.17mm) between the underside of the screw head and the wall. Install grab
bar on the wall by placing the round ends of the intermediate flange double-keyhole shaped mounting holes over the mounting screws (2) are located in the
middle of the flange slots. Install the mounting screws into the wall at the end flanges and secure tightly. Tighten the mounting screws at the intermediate
flange. Press all snap-flange covers into place to conceal mounting flanges.
Note: Recommend use of 1/4'' or #14 sheet metal or wood screws to install Intermediate Flange. #12 screws may also be used.
Important Notes:
1. Mounting Kits — Bobrick offers a mounting kit for installing grab bars; one Bobrick mounting kit is required for each flange.
-
Mounting Kit No.
252-30
Consists of (3) #14 x 2½'' Type-304 stainless steel,
Description
Phillips round-head, sheet-metal screws.
2.
Grab Bar Fastener —
Bobrick offers a grab bar fastening system that secures all Bobrick grab bar series; one Bobrick fastener is required for
each flange. Install grab bar without backing in wall requires minimum 5/8" (16mm) thick painted or tiled drywall.
WingIt™ Fastener No.
251-4
3. Optional Anchor Device —
one Bobrick concealed anchor device is requir
Bobrick grab bar anchor device includes stainless steel machine screws to be used for attaching grab bars to anchors.
Optional Anchor No.
2583
Consists of 10–32 x 5/16'' round-head, Phillips 18/8 stainless steel screws.
(1) WingIt g
ed for each flange.
rab bar fastener.
Anchor for 3/4" to 1" (19-25mm) panel
Description
Description
1 anchor required for each flange.
2586
Anchor for 1/2" to 1" (13mm) panel
1 anchor required for each flange.
SPECIFICATION:
Grab bar shall be Type-304 stainless steel with satin-finish. Grab bar shall have 18-gauge (1.2mm) wall thickness and 1-1/4" (32mm) outside diameter. Clearance
between the grab bar and wall shall be 1-1/2" (38mm). Concealed mounting flanges shall be 11-gauge (3.2 mm) thick stainless steel plate, 2" x 3
80mm), and equipped with at least two scr
ew holes for attachment to wall. Flange covers shall be 22-gauge (0.8mm) stainless steel, 3-1/4" (85mm) diameter,
-1/8" (50 x
and shall snap over mounting flanges to conceal mounting screws and/or WingIt fasteners. Ends of grab bar shall pass through concealed mounting flanges
and be heliarc welded to form one structural unit. Grab bar shall comply with accessible design (including ADAAG in the U.S.A.) for structural strength.
Grab Bar shall be Model __________ (insert model number) of Bobrick Washroom Equipment, Inc., Clifton Park, New York; Jackson,
Tennessee; and Los Angeles, California; Bobrick Washroom Equipment Company, Scarborough, Ontario; Bobrick Washroom Equipment Pty.
Ltd., Australia; and Bobrick Washroom Equipment Limited, United Kingdom.
The illustrations and descriptions herein are applicable to production as of the date of this Technical Data Sheet. B-5806 r8/10/18
The manufacturer reserves the right to, and does from time to time, make changes and improvements in designs and dimensions. © 2018 by Bobrick Washroom Equipment, Inc.
S/B
Printed in U.S.A.