Bobrick B-4998 User Manual

Technical Data
SWING-UP
B-4998
GRAB BAR
Specify Finish Required:
Patented
To Centerline
of Toilet
15-3/4''
400mm
Satin-finish
Satin-finish with peened gripping surface; add suffix .99 to model number
6-1/8''
155mm
5-1/8''
Bumper
130mm
S S
Mounting
Holes (4)
13mm
S
7-3/4''
195mm
S
13mm
8-3/4''
220mm
Grab Bar Backplate
Finish Face of Wall
8-3/4''
Stud
220mm
61''
1550mm
61''
1550mm
33''
840mm
29''
735mm
Adequate Backing
(Not Furnished)
890mm
To Top
Adequate
Backing or
Anchor
Plates
S
S
35''
34''
865mm
From Top
Mfg. Screws
29''
735mm
Grab Bar Backplate
33''
840mm
Finish Face of Floor
MATERIALS:
Grab Bar — 18-8 S, type-304, 18-gauge (1.2mm) stainless steel tubing with satin-finish. 1–1/4 (32mm) outside diameter. Ends are heliarc welded to flanges.
Backplate — 18-8 S, type-304, 3/16" (5mm) thick, satin-finish stainless steel with four screw holes for attachment to wall.
OPERATION:
Swing-up grab bar is manually raised for approach or departure and lowered to horizontal position for support; once grab bar is raised to the full upright (vertical) position, counter weighted design prevents grab bar from falling back down to the full horizontal position. Meets ICC/ANSI A117.1-2003 Accessibility Standards in U. S. A.
continued . . .
The illustrations and descriptions herein are applicable to production as of the date of this Technical Data Sheet. Revised 3/09 Printed in U.S.A. The manufacturer reserves the right to, and does from time to time, make changes and improvements in designs and dimensions. © 2009 by Bobrick Washroom Equipment, Inc.
STRENGTH:
Swing-up grab bar can support loads in excess of 250 pounds (113kg) if properly installed, complying with barrier-free accessibility guidelines (including ADAAG in the U.S.A.) for structural strength.
Caution: Grabs bars are no stronger than the anchors and walls to which they are attached and, therefore, must be firmly secured in order to sustain the loads for which they are intended.
INSTALLATION:
Provide concealed anchor device or backing as specified or required in accordance with local building codes before wall is finished. Fasten grab bar to anchor device or backing. Concealed anchor devices and mounted screws are not included with Bobrick grab bars and must be specified as an optional accessory.
SPECIFICATION:
Grab bar shall be type-304 stainless steel with satin finish. Grab bar shall have 18-gauge (1.2mm) wall thickness and 1–1/4" (32mm) outside diameter. Backplate shall be 3/16" (5mm) thick stainless steel, equipped with screw holes for attachment to wall. Swing-up grab bar shall be manually raised for approach or departure and lowered to horizontal position for support; counterweighted design shall prevent grab bar from falling back down to the full horizontal position once grab bar is raised to the full upright (vertical) position. Grab bar shall comply with ICC/ANSI A117.1-2003 Accessibility Standards in U. S. A.. Manufacturer's service and parts manual shall be provided to the building owner/manager upon request.
Swing-Up Grab Bar shall be Model __________ (insert model number) of Bobrick Washroom Equipment, Inc., Clifton Park, New York; Jackson, Tennessee; Los Angeles, California; Bobrick Washroom Equipment Company, Scarborough, Ontario; Bobrick Washroom Equipment Pty. Ltd., Australia; and Bobrick Washroom Equipment Limited, United Kingdom.
The illustrations and descriptions herein are applicable to production as of the date of this Technical Data Sheet. B-4998 Revised 3/09 Printed in U.S.A. The manufacturer reserves the right to, and does from time to time, make changes and improvements in designs and dimensions. © 2009 by Bobrick Washroom Equipment, Inc.
Loading...