INSTRUCTIONS FOR CONVERTING
SureFlo® AUTOMATIC COUNTER-MOUNTED SOAP DISPENSERS
B-824 LIQUID AND B-828 FOAM FROM BATTERIES TO AC POWER
WITH 3974-57, AC ADAPTER KIT (DOES NOT INCLUDE INTERCHANGEABLE PLUGS FOR U.K., EUROPE, AND AUSTRALIA.
IF NEEDED, ORDER ASSORTMENT PLUG KIT, PART. NO. 3974-58 TO FIT CORRESPONDING PLUG)
Fig. A
Bobrick Part Number 3974-57, AC Adapter Kit includes:
• 3974-19 Expandable 1" Grommet
• 3974-20 U.S. AC Adapter Plug
This kit is supplied with a cULus, CE, GS listed, double insulated AC to DC switching power supply. The power supply is equipped with a 117" (2971.8 mm) low voltage outlet cord terminated with a barrel connector for attachment with a mating jack located in the dispenser. The power supply is equipped with an interchangeable standard 2 pole NEMA plug intended for direct mounting into a standard 120V NEMA duplex outlet. For warranty purposes, it is required that the power converter must plug into an AC outlet that is not accessible to the dispenser user. If not available, consult a licensed electrical contractor. The power supply output is to be routed through the mounting wall as a low voltage, energy limited circuit, similar to a thermostat wire, with no requirement for electrical box or attachment strain relief. Use only the power supply supplied with this unit. Any substitution could damage the unit and will void any warranty.
(not needed for soap dispenser)
Fig. B
Activation
Light Pipe
Area
Powe r Cord Jack
1. Locate or provide an AC outlet that is not accessible to the dispenser user.
2. See a quali ed, licensed electrician for the proper installation of a standard 120V NEMA duplex outlet, if one is required, and for the proper routing of the 3974-18 AC to DC Switching Power Supply. The installation must comply with local building code.
3. Plug the barel plug end of the AC to DC switch power supply into the AC to DC power jack in the B-824/B-828 Automatic Soap Dispenser (see Fig. A). Extra cord should be stored in a location inaccessible to the dispenser user.
4. Plug power supply into an outlet, and allow unit to cycle through. (LED lights will  ash through the Light Pipe (see
Fig. B) of the unit as it cycles through and primes the
dispenser).
5. If not fully primed, prime dispenser by placing hand under spout repeatedly until fully primed. Hand must be removed from activation area to reset each time.
NOTE: If solid green LED does not light when activated, loosen Fiber Optic Nut (see Fig. C) and push in Fiber Optic Cables (see Fig. D) until fully seated into PC Board (not shown) behind the Rubber Fiber Optic Connector and retighten Fiber Optic Nut. Ensure Fiber Optic Cable color coded with red band is installed in the bottom hole with the wide key portion of the Rubber Fiber Optic
Connector on top.
For Trouble shooting dispenser refer to installation instruction sheet Form No. 824-81.
Fig. C
Fig. D
Fiber Optic Cables
Wide Key on Top Rubber Fiber Optic Connector
Red Band
Fiber Optic Nut
INSTRUCTIONS FOR CONVERTING
B-3974, B-39747, B-3979, B-2974, B-29744 AND B-72974 FROM BATTERIES TO AC POWER
WITH 3974-57, AC ADAPTER KIT (DOES NOT INCLUDE INTERCHANGEABLE PLUGS FOR U.K., EUROPE, AND AUSTRALIA.
IF NEEDED, ORDER ASSORTMENT PLUG KIT, PART. NO. 3974-58 TO FIT CORRESPONDING PLUG)
Bobrick Part Number 3974-57, AC Adapter Kit includes:
• 3974-19 Expandable 1" Grommet
• 3974-20 U.S. AC Adapter Plu
(Note: Other materials may be required for proper installations such as rubber hole grommets, cable ties, conduit, etc.)
This kit is supplied with a cULus, CE, GS listed, double insulated AC to DC switching power supply. The power supply is equipped with a 117" (2971.8 mm) low voltage outlet cord terminated with a barrel connector for attachment with a mating jack located in the dispenser. The power supply is equipped with an interchangeable standard 2 pole NEMA plug intended for direct mounting into a standard 120V NEMA duplex outlet. For warranty purposes, it is required that the power converter must plug into an AC outlet that is not accessible to the dispenser user. If not available, consult a licensed electrical contractor. The power supply output is to be routed through the mounting wall as a low voltage, energy limited circuit, similar to a thermostat wire, with no requirement for electrical box or attachment strain relief. Use only the power supply supplied with this unit. Any substitution could damage the unit and will void any warranty.
1. Unlock and open the door of the Dispenser Cabinet Assembly. Remove any batteries that are in the unit.
2. Locate the 1" access hole in the back of the cabinet behind the AC to DC power jack and install the 3974-19 Expandable 1" Grommet.
3. Locate or provide an AC outlet that is not accessible to the dispenser user.
4. See a qualied, licensed electrician for the proper installation of a standard 120V NEMA duplex outlet, if one is required, and for the proper routing of the 3974-18 AC to DC Switching Power Supply. The installation must comply with local building code.
DO NOT BRING HIGH VOLTAGE POWER INTO THE
CABINET FOR ANY REASON.
5. Route the power converter cord through the hole in the 3974-19 Expandable 1" Grommet and plug the barrel plug end of the 3974-18 AC to DC Switching Power Supply into the AC to DC power jack in the 3974-56 Roll Towel Module. If necessary, the cord can be brought into the Dispenser Cabinet from the top or the side of the cabinet by drilling a 1/2" to 1" hole.
6. Take care to protect the cord from any edges of the stainless steel cabinet.
7. No extra cord length should be accessible inside the cabinet. Extra cord should be stored in a location inaccessible to the dispenser user.
8. Mount or remount the unit onto or into the wall making sure the cord is not pinched or damaged.
9. Plug 3974-18 AC to DC Switching Power Supply into an outlet and allow 30 seconds for the unit to calibrate. The indicator light will ash to show that the unit is receiving the power.
g
B-3974 Automatic Roll Towel Dispenser
(Other Models Not Shown)
3974-18 AC to DC Switching Power Supply
3974-19 Expandable 1" Grommet
3974-56 Roll Towel Module
AC to DC Power Jack
Dispenser Cabinet (3974-50, B-2974)
© 2011 by Bobrick Washroom Equipment, Inc.
Form No. 3974-68 Rev. 12/16/11 Printed in U.S.A.
In the U.S.A.: BOBRICK WASHROOM EQUIPMENT, INC.
200 Commerce Drive, Clifton Park, New York 12065-1350 • Tel: (518) 877-7444 • FAX: (518) 877-5029 11611 Hart Street, North Hollywood, California 91605-5882 • Tel: (818) 982-9600 • FAX: (818) 503-1102
In Canada: BOBRICK WASHROOM EQUIPMENT COMPANY
45 Rolark Drive, Scarborough, Ontario M1R 3B1 • Ontario East: Tel: (877) 423-6555 • FAX: (877) 423-8555
• Manitoba West: Tel: (877) 423-6444 • FAX: (877) 423-8444
Loading...