Bobrick 1180 Specifications

Bobrick Washroom Equipment, Inc. 1080/1180 DuraLineSeries® Partitions Specification – 3/6/09
PRODUCT SPECIFICATION – SERIES 1080/1180
SECTION 10170
SOLID PHENOLIC PLASTIC TOILET PARTITIONS
PART 1 - GENERAL
1.02 Related Sections A. Support for ceiling-hung compartments. B. Wall backing required to secure mounting brackets. C. Support for floor-anchored compartments. D. Toilet room accessories.
1.03 References (including but not limited to) A. National Fire Protection Association 101 Life Safety Code, 2006 Edition, Chapter10 B. ANSI A117- 1986 Specifications for Making Buildings and Facilities Accessible to and Usable by
Physically Handicapped People. C. International Building Code (IBC), 2006 Edition, Chapters 8, 11, and 12. D. International Plumbing Code (IPC), 2006 Edition, Chapter 3, Section 10. E. Title 24, California Code of Regulations, Parts 2, 3, and 5. F. ADA, Accessibility Guidelines for Buildings and Facilities, Federal Register Volume 56, Number 144,
Rules and Regulations. G. Fair Housing Amendments Act of 1988, Accessibility Guidelines, Federal Register Volume 56, Number 44. H. Southern Building Code.
1.04 QUALITY ASSURANCE A. Manufacturers
1. Model numbers for compartments manufactured by Bobrick Washroom Equipment, Inc. are listed to
establish a standard of quality for design, function, materials, workmanship, and appearance. Other manufacturers may be submitted for evaluation by the architect by following the conditions of the substitutions clause. Unless approval is obtained ten days prior to the bid date, all bids shall be based on the standard of quality. The architect shall be the sole judge as to the acceptability of all products submitted for substitution.
2. Compartments shall be the product(s) of a single manufacturer.
1.05 Submittals A. Comply with requirements of Section regarding submittals. B. Manufacturer's Data
Page 1 of 5
Bobrick Washroom Equipment, Inc. 1080/1180 DuraLineSeries® Partitions Specification – 3/6/09
1. Provide required number copies of: a. Product data sheets. b. Installation instructions. c. Replacement parts information.
C. Shop Drawings
1. Provide required number of copies of all shop drawings.
2. Show fabrication and erection of compartment assemblies, to extent not fully described by
manufacturer's data sheets.
3. Show anchorage, accessory items and finishes.
4. Provide location drawings for bolt hole locations in supporting members for attachment of
compartments.
D. Samples
1. Furnish scale model of compartments, including stile, shoe, door, door hardware, divider panel, and
mounting brackets.
2. Furnish sections showing stile anchoring and leveling devices, concealed threaded inserts, panel and stile
construction and edge construction.
1.06 Product Delivery, Storage, and Handling A. Deliver items in manufacturer's original unopened protective packaging. B. Store materials in original protective packaging to prevent physical damage or wetting. C. Handle so as to prevent damage to finished surfaces.
1.07 Warranty A. Furnish ten-year limited warranty for panels, doors, and stiles against breakage, corrosion, delamination,
and defects in factory workmanship. B. Furnish one-year guarantee against defects in material and workmanship for stainless steel door hardware
and mounting brackets.
PART 2 - PRODUCTS
2.01 Configurations A. National Fire Protection Association and International Building Code Interior Wall and Ceiling Finish
Class A
1. Toilet Compartments shall be: Floor-Anchored (1181/1181.67 DuralineSeries)
- or ­ Overhead-Braced (1182/1182.67 DuralineSeries)
- or ­ Floor to Ceiling (1186/1186.67 DuralineSeries)
- or ­ Ceiling-Hung (1188/1188.67 DuralineSeries)
2. Urinal Screens shall be: Floor-Anchored (1181 DuralineSeries)
Page 2 of 5