1. SAFETY INSTRUCTIONS
1 . 1
ELECTRICAL SAFETY
WARNING! It is the responsibility of the Installer, owner and operator to read, understand and comply with the following:
1.1.1 All electrical wiring must be carried out by a fully qualified electrician in accordance with the current IEE wiring regulations.
1.1.2 The installation must be protected by a 30mA RCD for safe operation (not included).
1.1.3 The cold lead is 3m long. It can be cut / extended to suit the location of the mains power connection box.
1.1.4 Check the continuity and resistance of the floor mat cable before, during and after installation and record results on back page.
1.2 GENERAL SAFETY INSTRUCTIONS
The heating mat is intended for use under many floor coverings including: tile, natural stone, slate, porcelain, marble, limestone &
terracotta. It can be installed on top of suitably prepared suspended timber floors or solid concrete floors enabling installation in all room
types.
Always wear rubber sole boots when installing this mat and avoid unnecessary foot traffic over unprotected matting.
Ensure no sharp objects come in contact with the mat cable when installing.
All the orange heating cable must be installed in the floor and covered with adhesive and/or self-levelling compound.
A minimum clearance of 50mm should be left between the heating mat and perimeter walls.
Plan your installation carefully. Always under estimate the amount of matting required by approximately 10% as the orange heating cable
cannot be cut in length or reduced in size. Example: If area of floor to be heated is 4.05m² select a 3.5m² mat.
The thermostat floor limit sensor should be located centrally between two cable loops under the mat.
During installation, you may need to cut and turn the mat to fit the room. It is imperative that you never cut, twist or kink the orange
heating cable and that once turned two heating coils are never
closer than 50mm.
Ensure floor is clean, dry and free from sharp objects
before laying mat and insulation material.
Avoid unnecessary foot traffic over unprotected matting.
X DO NOT install the heating mat on uneven surfaces.
X DO NOT put the mat under permanent fixtures
(baths, toilets, fitted cabinets etc).
X DO NOT use screws or nails in
places where the heating mat
is installed.
X DO NOT shorten
the mat. Any attempt
to shorten the mat will
invalidate your guarantee
and put you at risk of
dangerous overheating of the
floor.
X DO NOT use thick rugs, bean bags,
exercise mats, dog beds or other similar
items on the heated floor as it may cause
localised overheating.
X DO NOT cover any heated part of the floor with walls,
solid or permanent floor fixed furniture as this can trap heat
and cause local overheating.